Human Touch HT-135 Troubleshooting Guide

Human Touch, LLC

Document Date: May 26, 2009

Contact: documentation@humantouch.com

Introduction

This Troubleshooting Guide walks you step-by-step through the diagnosis of HT-135 customer issues. It is important to follow these steps carefully, to ensure that the problem is diagnosed correctly, and therefore the appropriate repair action is taken.

Getting Started

  1. Turn the power switch on the back of the chair to Off, wait approximately five seconds, then turn it back On.
  2. Wait 30 seconds while a system check is performed, then verify that the problem still exists.
  3. If the problem still exists, choose from the following issues:
To Troubleshoot This Issue:Do The Following:
There is no movement on the chair when I power it onThe backrest massage mechanism and the foot and calf massager paddles should move when you power on the chair. If they do not, see "Power" on page 2.
My remote control is not workingSee "Remote" on page 3.
My chair is not massaging properlyIf the Percussion, Compression, Kneading or Rolling massage is not working properly, replace the backrest. If the Stretch feature is not working properly, make sure you are pressing and holding the Stretch button until the chair beeps twice (it takes several seconds for the chair to prepare for the Stretch function).
My foot and calf massager is not workingSee "Foot and Calf Massager" on page 3.

Power

Step 1: Check the power cord.

Verify that the power cord connection to the power panel is secure, and that the cord is not damaged. If the power cord is damaged, replace the backrest cover.

IMPORTANT: Be sure to note the serial number on the back of the backrest cover. Once the backrest cover is replaced, the chair will no longer contain the serial number.

Step 2: Check the wall outlet.

Plug a different device into the AC outlet into which the chair is plugged. If the device does not work (is not receiving power), the AC outlet is most likely not working. Plug the chair into a different AC outlet to verify that it receives power.

Step 3: If the chair is still not receiving power, replace the backrest.

A recent electrical surge may have damaged the main circuit board. Replace the backrest.

IMPORTANT: If you replace the backrest, be sure to note the serial number on the backrest cover. Once the backrest is replaced, the chair will no longer contain the serial number.

Remote

If one or more remote control LEDs do not light when you push the corresponding button, but the function the button controls works properly:

The remote control is not working properly. Verify that the remote control cable connection to the backrest cover is secure. If that does not solve the problem, replace the remote.

If the remote control LED lights but the function it controls is not working properly:

The problem is most likely in the function controlled by the remote, not in the remote itself. If the function that is not working is in the backrest, replace the backrest. If the function that is not working is in the foot and calf massager, replace the foot and calf massager.

Foot and Calf Massager

If the foot and calf massager hesitates when changing directions:

This is due to the gears shifting, and is perfectly normal.

If the foot and calf massager will not deploy or retract:

  1. Press the foot and calf button on the remote control, then wait 30 seconds.
  2. Do one of the following:
    • If the foot and calf massager does not activate, and after 30 seconds all foot and calf massager LEDS begin to flash, replace the backrest. DEALER NOTE: You may wish to replace the choke coil instead of the complete backrest assembly.
    • If you hear a clicking sound and the foot and calf massager actuator is making a humming sound, the foot and calf massager bracket may have been pushed up into the chair seat. This can be corrected by removing the front foot and calf actuator hinge pin, allowing the bracket to swing down into the proper position, then reinstalling the hinge pin. See the Foot and Calf Massager Actuator repair instructions for details. If this procedure does not resolve the problem, replace the foot and calf massager actuator.

If the foot and calf massager massages only on one side:

Replace the foot and calf massager.

If when you press the foot and calf massager button on the remote control the foot and calf massager paddles do not move and all foot and calf massager LEDs are all flashing:

  • If the serial number is prior to A21061221, replace the backrest. DEALER NOTE: You may wish to replace the choke coil instead of the complete backrest.
  • If the serial number is after A21061221, replace the foot and calf massager.

PDF preview unavailable. Download the PDF instead.

ht-135-troubleshooting-guide Acrobat Distiller 7.0.5 (Windows) , LLC

Related Documents

Preview HT-121 Troubleshooting Guide
A step-by-step guide to diagnosing and resolving common issues with the Human Touch HT-121 massage chair, covering power, remote control, massage functions, and foot and calf massager problems.
Preview HT-5040 Troubleshooting Guide - Human Touch
Find solutions for common issues with your Human Touch HT-5040 massage chair. This guide covers troubleshooting steps for power, remote control, massage functions, and the foot and calf massager, helping you maintain and repair your chair.
Preview Human Touch HT-5320 Troubleshooting Guide
A comprehensive troubleshooting guide for the Human Touch HT-5320 massage chair, covering common issues with power, remote control, backrest, and foot/calf massagers.
Preview HT-3200 Troubleshooting Guide | Human Touch
A comprehensive troubleshooting guide for the Human Touch HT-3200 massage chair, covering common issues and solutions for power, remote control, and foot/calf massager functions.
Preview HT-100 Troubleshooting Guide | Human Touch
A comprehensive troubleshooting guide for the Human Touch HT-100 massage chair, covering common issues and solutions for power, remote control, and massage functions.
Preview HT-7120 Troubleshooting Guide
A comprehensive troubleshooting guide for the Human Touch HT-7120 massage chair, providing step-by-step solutions for common issues related to power, remote control, massage functions, and more.
Preview Human Touch HT-125 Massage Chair Troubleshooting Guide
This guide helps diagnose and resolve common issues with the Human Touch HT-125 massage chair, covering power, remote, and foot/calf massager functions.
Preview Human Touch HT-5005 Troubleshooting Guide
A comprehensive troubleshooting guide for the Human Touch HT-5005 massage chair, providing step-by-step solutions for common issues related to power, remote control, backrest, and foot/calf massagers.