DEPSTECH WF020-025-028 FHD Inspection Camera User Manual
Model Numbers: WF020-025-028
Product Structure
The DEPSTECH inspection camera consists of the following components:
- 1. Power ON/OFF Button: Used to turn the device on and off.
- 2. Camera LED Dimmer: A dial to adjust the brightness of the camera's LED lights.
- 3. WiFi Signal Indicator:
- Blue LED Flashing: Ready for pairing.
- Blue LED Solid: Connection successful.
- 4. Power Indicator:
- Red LED Solid: Power system operating normally.
- Red LED Flashing: Low battery.
- Green LED Solid: Charging status.
- 5. Reset Button: Press and hold for 7 seconds to restore the product to factory settings.
- 6. Micro-USB Charging Port: Port for charging the device.
Step 1 - Download the App
To use the inspection camera, you need to download the "DEPSTECH-View" application.
For iOS users (iOS 9+): Search for and download the "DEPSTECH-View" app from the App Store.
For Android users (Android 7.0+): Search for and download the "DEPSTECH-View" app from the Google Play Store.
Scan the QR code below to download the app for both iOS and Android:
[QR Code for App Download]
Registration
After downloading the app, you need to register a personal account before use. Fill in your email, create a password, agree to the terms, and click the register button. Log in after successful registration. Ensure your mobile device is connected to the network during registration.
Step 2 - Power On
Press the power button to the "ON" position to turn on the endoscope. It is recommended to fully charge the product before the first use.
Step 3 - WiFi Connection
A. Go to the WiFi settings on your smart device (Android/iOS phone).
B. Search for the factory default WiFi SSID: DEPSTECH_****** or Jetion_*******. (Note: "******" represents a series of random numbers and letters.)
C. Select the network and enter the factory-set WiFi password: 12345678.
Please be patient, as it may take a few seconds for the WiFi signal to appear and connect.
Step 4 - Return to the APP
Once the endoscope and your smart device are successfully connected via WiFi, you can view the real-time image from the endoscope in the DEPSTECH-View APP. The blue Wi-Fi LED indicator on the endoscope will remain solid.
In the app, you will be prompted to select the connection type. Choose "WIFI" and click "OK".
APP Introduction
The DEPSTECH-View app provides the following functions:
- Rotate Button: Click to rotate the image by 90°.
- Take Photo Button: Click to capture a photo.
- Record Button: Click to start/stop video recording.
- Gallery Button: Click to view captured photos and videos.
- Settings Button: Click to access settings.
- Camera Switch Button: Click to switch between the main and side cameras.
Hidden Buttons: Tapping the screen will hide or show the control buttons.
Zoom In/Out Function: Use two fingers to pinch outwards to zoom in on the real-time image, and pinch inwards to zoom out.
APP Introduction (For WiFi SSID: DEPSTECH_******)
Within the app settings for this connection type, you can:
- Resolution: Click to select a different video resolution.
- WiFi Settings: Click "Reset" to modify the WiFi SSID and password. After changing, remember to click the reset button again.
- Channel Switch: Click "Switch" to toggle between 2.4G & 5G WiFi signals.
Privacy Policy and User Agreement | FAQ & Help
Modify WiFi name and password: Enter your desired WiFi name and password, then click "RESET".
APP Introduction (For WiFi SSID: Jetion_******)
For this connection type, you can:
- Modify WiFi name: Enter a new WiFi name.
- Modify password: Enter a new WiFi password.
- Modify Resolution: Click to change the video resolution (e.g., 640*480).
- Reboot device: Turn the device off and on again.
- Clear password: Clears the saved password.
After making any changes to WiFi name, password, or resolution, remember to click the "Modify WiFi name / password / resolution" button.
It is generally not recommended to change the default WiFi SSID/password as it may cause inconvenience for future use. If you must change it, please record the new WiFi SSID and password.
Charging Guide
- Connect the device to a DC 5V USB charging adapter.
- The green LED indicator will remain solid during charging.
- The green LED indicator will turn off once the device is fully charged.
Accessory Installation Guide
The accessories can be attached or detached by rotating them. Turn clockwise to attach and counter-clockwise to detach.
[Diagram showing how to attach and detach accessories by rotation]
SAFETY AND MAINTENANCE INFORMATION
Please read the manual carefully before use for your safety and a better user experience.
- After each use, turn off the endoscope and store it in a dry environment.
- Clean the camera lens with a soft cotton cloth and a small amount of alcohol for optimal image quality.
- Charge the device every three months to prolong battery life.
- Storage Temperature: 32-158 °F (0-70 °C).
- Working Temperature: 32-113 °F (0-45 °C).
- Children should only operate this device under adult supervision.
- Keep the device away from fire sources, liquids, and acids to prevent electric shock and damage.
- The device is not shockproof. Avoid high impacts, such as dropping the device from a height.
- The lens and tube are waterproof after assembly, but the WiFi box is not. The IP67 waterproof rating applies only to the camera probe, which can be submerged in water up to 3.33 ft (1 meter) for 30 minutes. Do not immerse the WiFi box in water.
- Dispose of batteries according to WEEE directives for environmental protection.
- It is normal for the camera to get warm, especially with the LED lights at maximum brightness, but this does not affect normal use or the lifespan of the endoscope.
- The WiFi transmission distance is approximately 16.5 feet (5 meters) without obstructions. Keep the WiFi box within this range of your phone/tablet.
- Avoid using the device in areas with strong WiFi interference, as this may affect the WiFi connection.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.
EU Declaration of Conformity
This product and any supplied accessories are marked with "CE", conforming to applicable harmonized European standards under Directive 2004/108/EC (Electromagnetic Compatibility) and Directive 2011/65/EU (Restriction of Hazardous Substances, amended by (EU) 2015/863).
2012/19/EU (WEEE Directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the EU. For proper recycling, return this product to your local supplier when purchasing equivalent new equipment or take it to designated collection points. More information: www.recyclethis.info.
2013/56/EU (Battery Directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the EU. Refer to product documentation for specific battery information. The battery is marked with this symbol, which may include inscriptions for Cadmium (Cd), Lead (Pb), or Mercury (Hg). For proper recycling, return the battery to your supplier or a designated collection point. More information: www.recyclethis.info.