Kenwood NX-1700H/1800H VHF/UHF Transceivers
One Radio with Multi-Protocol Support
Sound Performance, Smooth Operation
Emulating the distinguished NX-3000 and NX-5000 series, the NX-1700H/1800H mobile radio supports multiple protocols including NXDN™ and DMR as well as mixed digital & FM analog operation. It is packed with features essential for numerous enterprise and operation-critical applications. The radio is equipped with optimizable TX/RX audio quality and a customizable front panel that prioritizes simple convenience. Operational status is clear at a glance from the white backlit LCD display and the 7-color LED indicator.
A front view of the Kenwood NX-1700H/1800H transceiver, showing its compact design, microphone, LCD display, and control buttons.
Features
- "One Radio" with Multi-protocol Support: Designed to operate under NXDN or DMR digital, and FM analog protocols.
- Upgradable Digital/Analog mode by software option (no firmware upgrade required).
- Easy visible, white backlit LCD display: Alphanumeric, 10-digit, 13-character frame (aliases and icons).
- 7-color LED indicator used to display various radio status.
- Renowned KENWOOD Audio Quality: 6 W (max) loud audio and optimizable TX/RX audio profile, including Audio Equalizer, Auto Gain Control (TX/RX), and Microphone type settings.
- Max. 260 Channels per radio, 128 Zones per radio, and 250 Channels per zone.
- Various scan functions: Dual/Single Priority scan, Multi/Single Zone scan, and more.
- Orange-colored Emergency button & Customizable Emergency functions.
- Lone Worker mode.
- Remote Stun, Kill, Check capabilities.
- Dual Priority Scan.
- Max/Min Volume setting.
- Voice Announcement feature.
- Electronic Serial Number (ESN) display.
- Display Customization options.
- D-sub, 15-pin GPIO and audio connector.
- GPS connectivity (requires additional module).
- Horn Alert and Public Address functionality.
- Ignition Sense feature.
- 3.5 mm audio jack for external speaker.
- IP54 and MIL-STD 810C/D/E/F/G/H compliance.
Digital Modes
Digital – NXDN™ Mode
- FDMA: Very Narrow 6.25 kHz and Narrow 12.5 kHz Bandwidths.
- NXDN Conventional: Voice and Data Services.
- NXDN Type-D Trunking (Optional).
- Site Roaming.
- Digital / Analog Mixed Mode.
- Group / Individual Call support.
- Status / Short Data, Paging Call.
- Remote Stun Kill, Monitor, Check & Control.
- GPS Combination with additional module.
- Mixed mode operation.
- Late Entry feature.
- Digital Bit Scrambler.
- Over-the-Air Alias (OAA).
- Transparent Data support.
Digital – DMR Mode
- TDMA: 2-slot 12.5 KHz Bandwidth, equivalent to 6.25 KHz Very Narrow Bandwidths.
- DMR Tier II Conventional: Voice and Data services.
- Site Roaming.
- DMR Auto Slot Select.
- Dual-slot Direct Mode.
- Call Interruption.
- Group / Individual Call support.
- Status / Short Data, Paging Call.
- Remote Stun Kill, Monitor, Check & Control.
- GPS Combination with additional module.
- Digital / Analog Mixed Mode.
- Digital bit Scrambler.
- ARC4 Enhanced Encryption (Optional).
- Late Entry feature.
- Over-the-Air Alias (OAA).
FM Modes – General
- FM Conventional: QT/DQT, DTMF, 2-Tone.
- FleetSync®/II: PTT ID, Stun/Revive, Mute hold, Built-in Voice Inversion Scrambler, Talk back, Selcall per channel.
- MDC-1200: PTT ID ANI / Radio Inhibit / Uninhibit, Radio Check, Emergency, Compander Function per channel.
Accessories
All accessories may not be available in all markets. Contact an authorized KENWOOD dealer for details and complete list of all accessories.
- KMC-9C Desktop Microphone (non TDMA)
- KMC-59C Desktop Microphone
- KMC-65M Microphone [IP54/55]
- KMC-66M 12-Keypad Microphone [IP54/55]
- KES-5A External Speaker (Requires KCT-60)
- KES-8K External Speaker
- KCT-60 Connection cable (D-sub 15 to Molex 15 pin connector)
- KLF-2 Line Filter
- KCT-18 Ignition Sense Cable (Requires KCT-60)
- KCT-23 DC Power Cable
- KMB-10 Key Lock Adapter
- KPS-15 DC Power Supply (23A max)
- KMB-34 Mounting Case for KPS-15
- GPS15XL-W GPS Receiver Board
- GA25MCX GPS Antenna for GPS15XL-W
Specifications
General
Feature | NX-1700H | NX-1800H |
---|---|---|
Frequency Range | 136-174 MHz | 400-470 MHz |
Max. Channels Per Radio | 260 | 260 |
Number of Zones | 128 | 128 |
Number of Channels per Zone | 250 | 250 |
Channel Spacing | 12.5/25* kHz (Analog) 6.25/12.5 kHz (Digital) | 12.5/25* kHz (Analog) 6.25/12.5 kHz (Digital) |
Power Supply | 13.6 V DC ±15% | |
Current Drain (Standby) | 0.45 A | 0.45 A |
Current Drain (RX) | 2.4 A | 2.4 A |
Current Drain (TX) | 13 A | 13 A |
Operating Temperature | -22°F to +140°F (-30°C to +60°C) | |
Frequency Stability | ± 0.5 ppm | |
Dimensions (W x H x D) | 6.34 x 1.69 x 6.62 in. (161 x 43 x 168.2 mm.) (Projections Not Included) | |
Weight Radio | 2.67 lbs (1.21 kg) | |
FCC ID Type 1 | K44517000 | K44517100 |
FCC ID Type 2 | 282F-517000 | 282F-517100 |
ISED Certification Type 1 | ||
ISED Certification Type 2 |
*25/30 kHz in VHF/UHF Bands are not included in the models sold in the USA or US territories. Analog measurements made per TIA603. Specifications are measured according to applicable standards. Specifications shown are typical and subject to change without notice, due to advancements in technology.
Receiver
Feature | NX-1700H | NX-1800H |
---|---|---|
Sensitivity NXDN 6.25 kHz Digital (3% BER) | 0.18 μV | 0.18 μV |
Sensitivity NXDN 12.5 kHz Digital (3% BER) | 0.22 μV | 0.22 μV |
Sensitivity DMR 12 kHz Digital (5% BER) | 0.18 μV | 0.18 μV |
Sensitivity Analog 12 kHz (12dB SINAD) | 0.20 μV | 0.20 μV |
Sensitivity Analog 25 kHz (12dB SINAD) | 0.24 μV | 0.24 μV |
Selectivity Analog @ 12.5kHz | 65 dB | 65 dB |
Selectivity Analog @ 25kHz | 81 dB | 81 dB |
Intermodulation | 73 dB | 73 dB |
Spurious Rejection | 75 dB | 75 dB |
Audio Distortion | 3% | 3% |
Audio Output Power | 6 W / 4 Ω | 6 W / 4 Ω |
Transmitter
Feature | NX-1700H | NX-1800H |
---|---|---|
RF Power Output | 50 W / 25 W / 5 W | 45 W / 25 W / 5 W |
Spurious Emission | -73 dB | -75 dB |
FM Hum & Noise Analog @ 12.5kHz | 40 dB | 40 dB |
FM Hum & Noise Analog @ 25kHz | 50 dB | 50 dB |
Audio Distortion | 3% | 3% |
Emission Designator | 16K0F3E, 11K0F3E, 8K30F1E, 8K30F1D, 8K30F7W, 4K00F1E, 4K00F1D, 4K00F7W, 4K00F2D, 7K60FXD, 7K60FXW, 7K60FXE, 7K60F1E, 7K60F1D, 7K60F1W |
MIL-STD & IP
MIL Standard
MIL Standard | MIL 810C Methods/Procedures | MIL 810D Methods/Procedures | MIL 810E Methods/Procedures | MIL 810F Methods/Procedures | MIL 810G Methods/Procedures | MIL 810H Methods/Procedures |
---|---|---|---|---|---|---|
Low Pressure | 500.1/Procedure I | 500.2/Procedure I, II | 500.3/Procedure I, II | 500.4/Procedure I, II | 500.5/Procedure I, II | 500.6/Procedure I, II |
High Temperature | 501.1/Procedure I, II | 501.2/Procedure I, II | 501.3/Procedure I, II | 501.4/Procedure I, II | 501.5/Procedure I, II | 501.7/Procedure I, II |
Low Temperature | 502.1/Procedure I | 502.2/Procedure I, II | 502.3/Procedure I, II | 502.4/Procedure I, II | 502.5/Procedure I, II | 502.7/Procedure I, II |
Temperature Shock | 503.1/Procedure I | 503.2/Procedure I | 503.3/Procedure I | 503.4/Procedure I, II | 503.5/Procedure I | 503.7/Procedure I |
Solar Radiation | 505.1/Procedure I | 505.2/Procedure I | 505.3/Procedure I | 505.4/Procedure I | 505.5/Procedure I | 505.7/Procedure I |
Rain | 506.1/Procedure I, II | 506.2/Procedure I, II | 506.3/Procedure I, II | 506.4/Procedure I, III | 506.5/Procedure I, III | 506.6/Procedure I, III |
Humidity | 507.1/Procedure I, II | 507.2/Procedure II, III | 507.3/Procedure II, III | 507.4 | 507.5/Prcedure II | 507.6/Prcedure II |
Salt Fog | 509.1/Procedure I | 509.2/Procedure I | 509.3/Procedure I | 509.4 | 509.5 | 509.7 |
Dust | 510.1/Procedure I | 510.2/Procedure I | 510.3/Procedure I | 510.4/Procedure I, III | 510.5/Procedure I | 510.7/Procedure I |
Vibration | 514.2/Procedure VIII, X | 514.3/Procedure I | 514.4/Procedure I | 514.5/Procedure I | 514.6/Procedure I | 514.8/Procedure I |
Shock | 516.2/Procedure I, II, III, V | 516.3/Procedure I, IV, V | 516.4/Procedure I, IV, V | 516.5/Procedure I, IV, V | 516.6/Procedure I, IV, V | 516.8/Procedure I, IV, V, VI |
International Protection Standard
Standard | Rating |
---|---|
Dust & Water Protection*1 | IP54 (per IEC60529) |
*1 All interfaces must be fully sealed with appropriate covers or by designated genuine accessories.