Goodman FTXNG-A Series Inverter Split Unit Air Conditioner Engineering Data

Brand: Goodman

Product Type: Air Conditioner

Model Series: FTXNG-A

Description: This document provides comprehensive engineering data for the Goodman FTXNG-A Series Wall Mounted Inverter Split Unit Air Conditioner Heatpump operating at 60Hz. It includes detailed specifications, functions, dimensions, wiring and piping diagrams, capacity tables, operation limits, sound level information, and electrical characteristics for various models.

Introduction

Model Name and Power Supply

Indoor UnitOutdoor UnitPower Supply
FTXNG09AXVJURXNG09AXVJU1Phase, 208/230V, 60Hz
FTXNG12AXVJURXNG12AXVJU
FTXNG18AXVJURXNG18AXVJU

Nomenclature

Indoor Unit

DefinitionDescription
Unit CategoryF : Air-Cooled Split Indoor Unit
Product TypeT : Wall Mounted
SystemX : Inverter, Heatpump
GradeN : R410A, Internet Model
BrandG : Goodman Brand
Capacity Indication*09 : 9,000 Btu/h
Major Design CategoryA : A Series
Factory OriginX : Malaysia
Power SupplyVJ : 208/230V / 1Phase / 60Hz
CountryU : United States

Remark: *Capacity value under Nomenclature is an indication. Please refer to Specifications Data for exact capacity value.

Outdoor Unit

DefinitionDescription
Unit CategoryR : Air-Cooled Split Outdoor Unit
SystemX : Inverter, Heatpump
GradeN : R410A, Internet Model
BrandG : Goodman Brand
Capacity Indication*09 : 9,000 Btu/h
Major Design CategoryA : A Series
Factory OriginX : Malaysia
Power SupplyVJ : 208/230V / 1Phase / 60Hz
CountryU : United States

Functions

CategoryFunctionsFTXNG09/12A RXNG09/12AFTXNG18A RXNG18A
Inverter Basic FunctionOperation Limit for Cooling (°CDB)(O/D)10 - 4610 - 46
Operation Limit for Cooling (°FDB)(O/D)50 - 114.850 - 114.8
Operation Limit for Heating (°CWB)(O/D)-15 - 18-15 - 18
Operation Limit for Heating (°FWB)(O/D)5 - 64.45 - 64.4
CompressorScroll Compressor
Swing Compressor--
Rotary Compressor
Comfortable AirflowPower-airflow Flap
Power-airflow Dual Flaps
Power-airflow Diffuser
Wide Angle Louvers
Vertical Auto-Swing (Up and Down)
Horizontal Auto-Swing (Right and Left)
3D Airflow
Comfort ControlBreeze Airflow
Auto Fan Speed
Indoor Unit Quiet Operation
Intelligent Eye Operation
Automatic Defrosting
OperationAutomatic Operation
Programme Dry Function
Fan Only
Powerful Operation (Non Inverter)
Inverter Powerful Operation
Lifestyle ConvenienceEnergy Saving Function
Sleep Mode
Indoor Unit ON/OFF Button
Remote ControlR/C with Backlight
Signal Receiving Sign (R/C)
Set Temperature Display (R/C)
WIFI Connectivity**
Health & CleanSaranet Filter
Anti-virus Filter / Gin-ION Filter--
Catechin Filter / Green Tea Filter
Titanium Apatite Air-Purifying Filter
PM 2.5 Filter--
Streamer
Plasma
Wipe Clean Flat Panel
TimerWeekly Timer Operation (Wired R/C)
24-hour ON/OFF Timer (R/C)
Countdown ON/OFF Timer (R/C)
Worry Free (Reliability & Durability)Auto Restart (after Power Failure)
Self-diagnosis
Anti-corrosion Treatment of Outdoor Heat ExchangerBlue FinBlue Fin
FlexibilityPre-charged Piping Length32-13/16 ft32-13/16 ft
Either Side Drain (Right or Left)
BAG Connectivity**
DIII-NET Connectivity**
Remote ControllerWirelessBRC52B67BRC52B67
Wired--

Note: •: Available, -: Not Available, *: Optional (Refer to DAMA Spare Part team for more details on optional items.)

Specifications

The following tables detail the specifications for the Goodman FTXNG-A Series Inverter Split Unit Air Conditioner models.

FTXNG09A / RXNG09A

MODELINDOOR UNIT OUTDOOR UNITCoolingHeating
kWBtu/hkWBtu/h
Rated Capacity (Min. ~ Max.)2.57 (1.30 - 3.00)8800 (4400 - 10200)2.75 (1.30 - 3.80)9400 (4400 - 13000)
Moisture Removalgal/h0.09
Rated Running CurrentA3.823.70
Rated Power ConsumptionW800774
EER2Btu/h/W11.018.0
SEER2N/AN/A
COPW/WN/A3.56
HSPF2N/A9.0
Power Factor (Rated)N/AN/A
Piping ConnectionsLiquidinch (mm)1/4" (6.35)1/4" (6.35)
Gasinch (mm)3/8" (9.52)3/8" (9.52)
Refrigerant TypeR410A
Chargelbs (kg)1.54 (0.7)1.54 (0.7)
Max. Interunit Piping Lengthft (m)65-5/8 (20)65-5/8 (20)
Max. Interunit Height Differenceft (m)32-13/16 (10)32-13/16 (10)
Chargelessft (m)32-13/16 (10)32-13/16 (10)
Amount of Additional Charge of Refrigerantoz/ft (g/m)0.21 (20)0.21 (20)
Drawing No.3D143694C
INDOOR UNIT
Front Panel ColourWHITE
Airflow RateTurboCFM466402
HighCFM431
MediumCFM322
LowCFM249
QuietCFM
Sound Pressure Level (H/M/L/Q)dBA43/36/29/1942/35/29/25
FanTypeCROSS FLOW
DriveDIRECT
Speed3 STEPS, QUIET, AUTO, TURBO
TypeDIRECT CURRENT
Fan MotorMotor OutputW22
Running Current (Rated)A0.10
Power Consumption (Rated)W29
Air Direction ControlUP, DOWN, LEFT, RIGHT
Air FilterCATECHIN
Dimensions (H x W x D)inch (mm)11-1/3 x 30-5/16 x 9-3/16 (288 x 770 x 234)
Packaged Dimensions (H x W x D)inch (mm)13-7/8 x 32-3/4 x 12-3/8 (350 x 830 x 314)
Weightlbs (kg)20.3 (9.2)
Gross Weightlbs (kg)24.7 (11.2)
Condensate Drain Sizeinch (mm)5/8 (16)
Document No.3D143550B
OUTDOOR UNIT
Casing ColourIVORY WHITE
Airflow Rate HighCFM10831103
Sound Pressure LeveldBA4648
FanTypePROPELLER
DriveDIRECT
TypeDIRECT CURRENT
Index of protection (IP)24
Insulation GradeE
Fan MotorRunning Current (Rated)A0.600.61
Power Consumption (Rated)W3246
Motor OutputW2626
Poles8
CompressorTypeHERMETIC SWING
Model1YC23AUXDA
Oil typeDAPHNE FVC50K
Oil amountoz (cm3)12.4 (375)
Heat Exchanger TypeFIN TUBE
Dimensions (H x W x D)inch (mm)21-11/16 x 26-1/2 x 11-3/16 (550 x 675 x 284)
Packaged Dimensions (H x W x D)inch (mm)24-1/64 x 31-3/8 x 15-1/8 (610 x 801 x 384)
Weightlbs (kg)55 (25)
Gross Weightlbs (kg)62 (28)
Document No.3D143595A

Note: 1) ALL UNITS ARE BEING TESTED ACCORDING TO AHRI 210/240 STANDARD. 2) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

Cooling Conditions: Indoor: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB), Outdoor: 95°FDB (35°CDB)

Heating Conditions: Indoor: 70°FDB (21.1°CDB), Outdoor: 47°FDB (8.3°CDB) / 43°FWB(6.1°CWB)

FTXNG12A / RXNG12A

MODELINDOOR UNIT OUTDOOR UNITCoolingHeating
kWBtu/hkWBtu/h
Rated Capacity (Min. ~ Max.)3.22 (1.30 - 3.90)11000 (4400 - 13300)3.31 (1.30 - 4.81)11300 (4400 - 16400)
Moisture Removalgal/h0.18
Rated Running CurrentA3.224.55
Rated Power ConsumptionW12941004
EER2Btu/h/W8.5N/A
SEER2N/AN/A
COPW/WN/A3.30
HSPF2N/A9.0
Power Factor (Rated)N/AN/A
Piping ConnectionsLiquidinch (mm)1/4" (6.35)1/4" (6.35)
Gasinch (mm)3/8" (9.52)3/8" (9.52)
Refrigerant TypeR410A
Chargelbs (kg)2.09 (0.95)2.09 (0.95)
Max. Interunit Piping Lengthft (m)65-5/8 (20)65-5/8 (20)
Max. Interunit Height Differenceft (m)32-13/16 (10)32-13/16 (10)
Chargelessft (m)32-13/16 (10)32-13/16 (10)
Amount of Additional Charge of Refrigerantoz/ft (g/m)0.21 (20)0.21 (20)
Drawing No.3D143694C
INDOOR UNIT
Front Panel ColourWHITE
Airflow RateTurboCFM473412
HighCFM436
MediumCFM316
LowCFM247
QuietCFM132210
Sound Pressure Level (H/M/L/Q)dBA45/37/31/1943/36/30/26
FanTypeCROSS FLOW
DriveDIRECT
Speed3 STEPS, QUIET, AUTO, TURBO
TypeDIRECT CURRENT
Fan MotorMotor OutputW22
Running Current (Rated)A0.10
Power Consumption (Rated)W29
Air Direction ControlUP, DOWN, LEFT, RIGHT
Air FilterCATECHIN
Dimensions (H x W x D)inch (mm)11-1/3 x 30-5/16 x 9-3/16 (288 x 770 x 234)
Packaged Dimensions (H x W x D)inch (mm)13-7/8 x 32-3/4 x 12-3/8 (350 x 830 x 314)
Weightlbs (kg)21.4 (9.7)
Gross Weightlbs (kg)25.8 (11.7)
Condensate Drain Sizeinch (mm)5/8 (16)
Document No.3D143550B
OUTDOOR UNIT
Casing ColourIVORY WHITE
Airflow Rate HighCFM1051966
Sound Pressure LeveldBA4848
FanTypePROPELLER
DriveDIRECT
TypeDIRECT CURRENT
Index of protection (IP)24
Insulation GradeE
Fan MotorRunning Current (Rated)A0.610.61
Power Consumption (Rated)W4646
Motor OutputW2626
Poles8
CompressorTypeHERMETIC SWING
Model1YC23AUXDA
Oil typeDAPHNE FVC50K
Oil amountoz (cm3)12.4 (375)
Heat Exchanger TypeFIN TUBE
Dimensions (H x W x D)inch (mm)21-11/16 x 26-1/2 x 11-3/16 (550 x 675 x 284)
Packaged Dimensions (H x W x D)inch (mm)24-1/64 x 31-3/8 x 15-1/8 (610 x 801 x 384)
Weightlbs (kg)62 (28)
Gross Weightlbs (kg)68 (31)
Document No.3D143595A

Note: 1) ALL UNITS ARE BEING TESTED ACCORDING TO AHRI 210/240 STANDARD. 2) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

Cooling Conditions: Indoor: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB), Outdoor: 95°FDB (35°CDB)

Heating Conditions: Indoor: 70°FDB (21.1°CDB), Outdoor: 47°FDB (8.3°CDB) / 43°FWB(6.1°CWB)

FTXNG18A / RXNG18A

MODELINDOOR UNIT OUTDOOR UNITCoolingHeating
kWBtu/hkWBtu/h
Rated Capacity (Min. ~ Max.)5.27 (1.96 - 5.86)18000 (6700 - 20000)5.24 (1.70 - 6.60)17900 (5800 - 22500)
Moisture Removalgal/h0.41
Rated Running CurrentA7.536.98
Rated Power ConsumptionW17141590
EER2Btu/h/W10.5N/A
SEER2N/AN/A
COPW/WN/A3.30
HSPF2N/A8.5
Power Factor (Rated)N/AN/A
Piping ConnectionsLiquidinch (mm)1/4" (6.35)1/2" (12.70)
Gasinch (mm)1/2" (12.70)1/2" (12.70)
Refrigerant TypeR410A
Chargelbs (kg)3.20 (1.45)3.20 (1.45)
Max. Interunit Piping Lengthft (m)98-1/2 (30)98-1/2 (30)
Max. Interunit Height Differenceft (m)32-13/16 (10)32-13/16 (10)
Chargelessft (m)32-13/16 (10)32-13/16 (10)
Amount of Additional Charge of Refrigerantoz/ft (g/m)0.21 (20)0.21 (20)
Drawing No.3D143694C
INDOOR UNIT
Front Panel ColourWHITE
Airflow RateTurboCFM754395
HighCFM716
MediumCFM605
LowCFM467
QuietCFM
Sound Pressure Level (H/M/L/Q)dBA48/43/37/3346/41/36/33
FanTypeCROSS FLOW
DriveDIRECT
Speed3 STEPS, QUIET, AUTO, TURBO
TypeDIRECT CURRENT
Fan MotorMotor OutputW39
Running Current (Rated)A0.17
Power Consumption (Rated)W54
Air Direction ControlUP, DOWN, LEFT, RIGHT
Air FilterCATECHIN
Dimensions (H x W x D)inch (mm)11-11/16 x 39-9/16 x 10-3/4 (297 x 990 x 273)
Packaged Dimensions (H x W x D)inch (mm)14-1/4 x 42-1/4 x 14-1/8 (362 x 1073 x 358)
Weightlbs (kg)31 (14)
Gross Weightlbs (kg)36 (16.5)
Condensate Drain Sizeinch (mm)5/8 (16)
Document No.3D143550B
OUTDOOR UNIT
Casing ColourIVORY WHITE
Airflow Rate HighCFM19871952
Sound Pressure LeveldBA5353
FanTypePROPELLER
DriveDIRECT
TypeDIRECT CURRENT
Index of protection (IP)23
Insulation GradeE
Fan MotorRunning Current (Rated)A1.301.30
Power Consumption (Rated)W8585
Motor OutputW5555
Poles8
CompressorTypeHERMETIC SWING
Model2Y147AKCX2A
Oil typeDAPHNE FVC50K
Oil amountoz (cm3)21.5 (650)
Heat Exchanger TypeFIN TUBE
Dimensions (H x W x D)inch (mm)27-13/32 x 36-5/8 x 13-13/16 (696 x 930 x 351)
Packaged Dimensions (H x W x D)inch (mm)29-7/8 x 42-3/8 x 18-7/8 (760 x 1075 x 480)
Weightlbs (kg)97 (44)
Gross Weightlbs (kg)106 (48)
Document No.3D143595A

Note: 1) ALL UNITS ARE BEING TESTED ACCORDING TO AHRI 210/240 STANDARD. 2) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

Cooling Conditions: Indoor: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB), Outdoor: 95°FDB (35°CDB)

Heating Conditions: Indoor: 70°FDB (21.1°CDB), Outdoor: 47°FDB (8.3°CDB) / 43°FWB(6.1°CWB)

Dimensions

The following sections describe the physical dimensions of the indoor and outdoor units. Detailed diagrams are provided in the original document.

Indoor Unit Dimensions

Model: FTXNG09/12A

Diagrams illustrate the front, rear, and bottom views of the indoor unit, showing dimensions for width, height, and depth. Key dimensions include:

Model: FTXNG18A

Diagrams illustrate the front, rear, and bottom views of the indoor unit, showing dimensions for width, height, and depth. Key dimensions include:

Wiring Diagrams

Wiring diagrams are provided for both indoor and outdoor units to illustrate electrical connections.

Indoor Unit Wiring Diagram (Model: FTXNG-A)

This diagram shows connections for the fan motor (MF), air swing motor (MS), indoor coil thermistor (TH1), room thermistor (TH2), and control board connections (CN_SW_LR, CN_DSP, CN_COIL, CN_SW_UD, CN S21, CN_NS). It also indicates power supply lines (LIVE, NEUTRAL) and field wiring connections. Optional WIFI ADAPTER and WIRED ACCESSORY connections are also noted.

Outdoor Unit Wiring Diagrams

Model: RXNG09/12A

The diagram illustrates connections for the four-way valve (4WV), fan motor (MF), compressor motor (MC), overload protector (OLP), fuses (FU2, FU3), electronic expansion valve (EXV), and terminal block (TB). It details power supply connections, wiring to sensors (Outdoor Air Sensor, Heat Exchanger Sensor, Discharge Sensor), and connections to the indoor unit. Notation includes wire colors (BLUE, YELLOW, RED, BLACK, ORANGE, WHITE, GREEN) and terminal designations.

Model: RXNG18A

This diagram shows similar components including the compressor motor (MC), fan motor (MF), electronic expansion valve (EXV), overload protector (OLP), fuses (FU1, FU2, FU3), and terminal block (TB). It details power supply, sensor connections, and connections to the indoor unit, using wire colors and terminal designations.

Piping Diagrams

Piping diagrams illustrate the refrigerant flow and connections for the air conditioning systems.

Indoor Unit Piping Diagrams

Model: FTXNG09A

Diagram shows the indoor unit's heat exchanger, cross flow fan, and fan motor. It indicates field piping connections (1/4" CuT and 3/8" CuT) to a single union joint, and refrigerant flow for cooling and heating.

Model: FTXNG12A

Similar to FTXNG09A, this diagram shows the indoor unit's heat exchanger, cross flow fan, and fan motor, with field piping connections (1/4" CuT and 3/8" CuT) to a single union joint, and refrigerant flow for cooling and heating.

Model: FTXNG18A

This diagram shows the indoor unit's heat exchanger, distributor, cross flow fan, and fan motor. It indicates field piping connections (1/4" CuT and 1/2" CuT) and refrigerant flow for cooling and heating.

Outdoor Unit Piping Diagrams

Model: RXNG09A

Diagram illustrates the outdoor unit's components including the heat exchanger, compressor, propeller fan, four-way valve, motor operated valve, strainers, and mufflers. It shows field piping connections (3/8" CuT, 5/16" CuT, 1/4" CuT) and refrigerant flow for cooling and heating.

Model: RXNG12A

This diagram shows the outdoor unit's heat exchanger, compressor, propeller fan, four-way valve, motor operated valve, strainers, and mufflers. It indicates field piping connections (3/8" CuT, 5/16" CuT, 1/4" CuT) and refrigerant flow for cooling and heating.

Model: RXNG18A

This diagram shows the outdoor unit's heat exchanger, compressor, propeller fan, four-way valve, electronic expansion valve, strainers, and mufflers. It indicates field piping connections (1/2" CuT, 3/8" CuT, 1/4" CuT) and refrigerant flow for cooling and heating.

Capacity Tables

The following tables provide detailed capacity information (Total Capacity - TC, Sensible Heat Capacity - SHC, Power Input - PI) for various operating conditions.

Capacity Data for FTXNG09A - RXNG09A

Tables show Cooling and Heating capacities based on Indoor and Outdoor temperatures (°C and °F). Units for TC/SHC are kBtu/h or kW, and PI is in kW.

Capacity Data for FTXNG12A - RXNG12A

Tables show Cooling and Heating capacities based on Indoor and Outdoor temperatures (°C and °F). Units for TC/SHC are kBtu/h or kW, and PI is in kW.

Capacity Data for FTXNG18A - RXNG18A

Tables show Cooling and Heating capacities based on Indoor and Outdoor temperatures (°C and °F). Units for TC/SHC are kBtu/h or kW, and PI is in kW.

Capacity Correction Factor by Length of Refrigerant Piping

Graphs illustrate the capacity correction factor as a function of refrigerant piping length (in meters and feet) for both cooling and heating operations for different model series (FTXNG09A/RXNG09A, FTXNG12A/RXNG12A, and FTXNG18A/RXNG18A). The graphs show that the correction factor decreases as piping length increases. Notes explain that the correction ratio is the same for different installation heights and that capacity is calculated as engineering data multiplied by the capacity correction factor. The actual unit piping length must not exceed the maximum shown.

Operation Limit

Graphs display the operational limits for the air conditioning units based on indoor and outdoor temperatures.

Cooling Operation Limits:

The graph plots Outdoor Temperature (°FDB) against Indoor Temperature (°FWB). It defines regions for "Continuous operation" and "Pull-down period". For example, continuous operation is possible within a range of approximately 50°F to 86°F outdoor temperature and 50°F to 86°F indoor wet-bulb temperature.

Heating Operation Limits:

The graph plots Outdoor Temperature (°FWB) against Indoor Temperature (°FDB). It indicates the range for "Continuous operation". For example, continuous operation is possible from approximately 14°F to 86°F outdoor wet-bulb temperature and 50°F to 86°F indoor dry-bulb temperature.

Sound Level

Measuring Location

A diagram shows the standard measuring location for sound level tests: 1.0 meter horizontally and 0.8 meters vertically from the unit, in an anechoic chamber.

Sound Pressure Level

Tables provide the 1/1 Octave A-weighted Sound Pressure Level (dB, ref 20µPa) for different models (FTXNG09A, FTXNG12A, FTXNG18A) at various speeds (High, Med, Low, Quiet) for both Cooling and Heating modes. The data includes levels for different frequency bands (63Hz to 8kHz) and an Overall Noise level (dBA).

NC Curve

NC (Noise Criteria) curves are presented graphically, plotting Octave Band Sound Pressure Level (dB) against Octave Band Center Frequency (Hz). The curves represent different noise criteria levels (NC-20 to NC-70) and show how the sound output of the units at different speeds (Quiet, Low, Medium, High, Turbo) compares to these criteria. The note clarifies that SILENT (SL) is equivalent to QUIET (Q).

Electric Characteristic

The table below summarizes the electrical characteristics for the unit combinations.

Unit CombinationPower SupplyCOMPOFMIFM
Voltage RangeMCAMOPRHzAkWMOCkWMOC
FTXNG09A RXNG09A60Hz-208V, 60Hz-230VMAX. 60Hz 253V MIN. 60Hz 187V12.3515884.340.0260.600.0220.35
FTXNG12A RXNG12A60Hz-208V, 60Hz-230VMAX. 60Hz 253V MIN. 60Hz 187V12.4015965.570.0260.610.0220.40
FTXNG18A RXNG18A60Hz-208V, 60Hz-230VMAX. 60Hz 253V MIN. 60Hz 187V16.5520908.170.0551.300.0390.55

Symbols:

Notes:

  1. RHz is the max frequency that occurs in cooling and heating operation.
  2. RLA is the max current that occurs in cooling and heating operation.
  3. Maximum allowable voltage unbalance between phases is 2%.
  4. Select wire size based on the larger value of MCA.
  5. Use circuit breaker instead of fuse.

PDF preview unavailable. Download the PDF instead.

ED5WM16R-NA23V2 - FTXNG A - Engineering Manual - Revised (1) Adobe PDF Library 17.0 Adobe InDesign 18.1 (Windows)

Related Documents

Preview Goodman FTXNG-A Series Inverter Split Unit Air Conditioner Engineering Data
This document provides comprehensive engineering data for the Goodman FTXNG-A Series Inverter Split Unit Air Conditioner with Heatpump functionality. It includes detailed specifications, nomenclature, functions, dimensions, wiring and piping diagrams, capacity tables, operation limits, sound level data, and electrical characteristics for models FTXNG09A, FTXNG12A, and FTXNG18A, along with their corresponding outdoor units RXNG09A, RXNG12A, and RXNG18A.
Preview Goodman FTXNG-A Series Engineering Data: Inverter Split Unit Air Conditioner
Comprehensive engineering data for the Goodman FTXNG-A Series Inverter Split Unit Air Conditioner, featuring wall-mounted heat pump models. This document includes detailed specifications, dimensions, wiring and piping diagrams, capacity tables, operation limits, sound pressure levels, and electrical characteristics for models FTXNG09A, FTXNG12A, and FTXNG18A with corresponding outdoor units RXNG09A, RXNG12A, and RXNG18A.
Preview Goodman R410A Inverter Wall Mounted Heatpump FTXNG-A Series
Comprehensive overview of the Goodman R410A Inverter Wall Mounted Heatpump, FTXNG-A Series. Features include inverter technology for energy efficiency and consistent comfort, DC Inverter motor, swing compressor for quiet operation, lifestyle convenience functions (Powerful operation, ECO+, Sleep mode), advanced cleanliness features (Catechin and Titanium Apatite filters), and detailed technical specifications.
Preview Goodman R410A Inverter Wall Mounted Heatpump FTXNG-A Series Product Brochure
Explore the features and specifications of the Goodman R410A Inverter Wall Mounted Heatpump FTXNG-A Series. This brochure details product line-up, advanced inverter technology, lifestyle convenience features, cleanliness functions, and comprehensive technical specifications for models FTXNG09AXVJU, FTXNG12AXVJU, and FTXNG18AXVJU.
Preview Goodman R410A Split Series Room Air Conditioner Installation Manual
This installation manual provides comprehensive guidance for setting up Goodman R410A Split Series room air conditioners, detailing safety protocols, site selection, unit installation, piping, wiring, and commissioning for optimal performance and safety.
Preview Goodman E Series Inverter Wall-Mounted Heat Pump System | 18 SEER2, 9.0 HSPF2
Discover the Goodman E Series Inverter Wall-Mounted Heat Pump System, offering superior comfort and energy efficiency with advanced inverter technology. This brochure details features, benefits, and technical specifications for models like the 18 SEER2 unit.
Preview Goodman Split System Air Conditioners: R-410A & R-32 Product Overview and Specifications
Explore Goodman's range of split system air conditioners, featuring R-410A and new R-32 models. This document provides an overview of key features, SEER2 ratings, compressor types, and technical specifications for models like GXV9S, GXV6S, GLXT7C, GLXS5B, GLXS4M, GLXS4B, and GLXS3B.
Preview Goodman Split System Air Conditioners with R-32 Refrigerant
Explore Goodman's range of split system air conditioners featuring new R-32 products. Learn about their heritage, commitment to comfort, quality features, and extended service plans.