Midmark® Preva Intraoral X-Ray System
Designing better care.
FLAWLESS IMAGING AND ENHANCED WORKFLOW
Preva packs many powerful features into one attractive, reliable system.
Detect dental caries and other problem areas with the razor-sharp images achieved through Midmark Preva Intraoral X-Ray systems. Preva systems are easy to operate and provide effortless movement for efficient workflows with one-handed, drift-free positioning. Designed to capture the images needed in just one shot, Preva units can help minimize patient stress.
Preva X-ray systems use a high-frequency direct current (DC) method of image capture in a range of models—Preva DC, Preva 2.0, and Preva Plus—and mounting options for your practice needs. The Preva 2.0 includes a high-speed USB connector for your digital sensors. The Preva Plus is integrated directly with the Midmark Intraoral Digital Sensor System and includes built-in sensor storage for convenience and sensor protection.
Use the Preva Intraoral X-Ray System to:
- Identify cavities and visualize tooth roots
- Examine the status of developing teeth
- Monitor the overall health of the bony area surrounding the tooth
[Image Description: A photograph shows a dental operatory with a Midmark Preva Intraoral X-Ray system mounted on an articulated arm positioned above a dental chair. The system features a sleek, modern design. Two inset images show diagnostic X-ray views of teeth (labeled 01) and a dental professional interacting with the X-ray unit (labeled 02).]
FEATURES
- The Preva system is designed for effortless movement and fast one-handed positioning.
- Auto-calibration between every capture ensures consistent image quality.
- The proprietary dual-arm braking system helps the head stay exactly where you position it without sagging or drifting.
- Preva provides a 0.4 mm focal spot for sharp, well-defined details that allow easy identification of pathology with both film and digital sensors.
- The easy-to-use LCD control panel with large icons helps to identify target tooth, receptor type, and patient size while offering pre-programmed technique settings.
- All Preva models are available in multiple mounting configurations to best suit your operatory needs: wall, cabinet, or mobile.
- The Preva Plus is configured with the additional integration of the Midmark Intraoral Digital Sensor System and built-in storage to help keep sensors from being damaged or misplaced.
- Preva units are designed and packaged for fast and easy installation.
Additional Features
01 For consistently superior diagnostic images:
Selectable options allow you to determine the techniques you prefer to control according to clinical or procedural needs.
- kV: 60, 65, and 70
- mA: 4, 5, 6, and 7
- Time: 0.02 seconds to 2 seconds
02 Grow with the Preva 2.0:
The Preva 2.0 gives you a high-speed USB connector so you can go digital when your practice is ready.
X-RAY SPECIFICATIONS
Specification | Value |
---|---|
Line voltage | 110 V to 230 V, ± 10%, 50 Hz or 60 Hz |
Tube potential | 60 kV, 65 kV, or 70 kV |
Tube current | 4 mA, 5 mA, 6 mA, or 7 mA |
Exposure time | 0.02 s to 2 s |
Cone length | 8" (20 cm) |
Focal spot | 0.4 mm (IEC 60336) |
Duty factor | 1:15 |
Shipping weight (wall mount) | 43 kg (95 lb) |
Applicable Federal regulations | 21 CFR, UL, IEC, TGA 2002 |
Warranty | 2-year, limited |
Options
- Exposure Hand Switch
- Cone Length: 8" (20 cm) or 12" (30 cm)
- Rounded Cone Opening: 2.3" (60 mm)
- Rectangular Cone Opening: 1.7" x 1.3" (45 mm × 35 mm), 1.5" x 1.1" (40 mm × 30 mm), or 1.1" x 0.7" (30 mm × 20 mm)
- Total Reach: 56", 66", 76", or 82"
- Mounting Plate: single stud, two stud, or metal stud
Minimum ceiling height
86.5" (220 cm)
Cabinet passthrough (alternate)
- Option 1: 66" Arm: 26.75" (W) x 47.5" (D) (68 cm x 121 cm)
- Option 2: 76" Arm: 36.75" (W) x 47.5" (D) (93.5 cm x 121 cm)
Mobile
- Base: 26.9" (W) x 36" (L) (68.3 cm x 91.4 cm)
- Arm reach: 56" (142 cm)
- Height: 76.9" (195.3 cm)
X-RAY PART NUMBERS
Single Stud Mount
Reach | Preva DC | Preva 2.0 | Preva Plus (with size 1 or size 2 sensor) |
---|---|---|---|
76" | PE7017 (white) P7017 (grey) | — | — |
66" | PE7016 (white) P7016 (grey) | — | — |
56" | PE7015 (white) P7015 (grey) | — | — |
Double Stud Mount
Reach | Preva DC | Preva 2.0 | Preva Plus (with size 1 or size 2 sensor) |
---|---|---|---|
82" | PE7018-P (white) P7018-P (grey) | DCD8-W2Z/H | DCD8-W2Z/H/S1 DCD8-W2Z/H/S2 |
76" | PE7017-P (white) P7017-P (grey) | DCD7-W2Z/H | DCD7-W2Z/H/S1 DCD7-W2Z/H/S2 |
66" | PE7016-P (white) P7016-P (grey) | DCD6-W2Z/H | DCD6-W2Z/H/S1 DCD6-W2Z/H/S2 |
56" | PE7015-P (white) P7015-P (grey) | DCD5-W2Z/H | DCD5-W2Z/H/S1 DCD5-W2Z/H/S2 |
Mobile
Configuration | Preva DC | Preva 2.0 | Preva Plus (with size 1 or size 2 sensor) |
---|---|---|---|
Mobile | PE7017M (white) P7017GM (grey) | DCDM-W0Z/H | DCDM-W0Z/H/S1 DCDM-W0Z/H/S2 |
SENSOR SPECIFICATIONS
Specification | Size 1 | Size 2 |
---|---|---|
Film size equivalent | 0.9" x 1" x 0.2" (24 mm x 27 mm x 5.5 mm) | 1.3" x 1.7" x 0.2" (32 mm x 43 mm x 5.5 mm) |
Dimensions | 1.2" x 0.8" (30 mm x 20 mm) | 1.4" x 1" (36 mm x 26 mm) |
Active area | 3.61 ft (1.1 m) or 9.84 ft (3 m) | 3.61 ft (1.1 m) or 9.84 ft (3 m) |
Sensor cable | 3.61 ft (1.1 m) or 9.84 ft (3 m) | 3.61 ft (1.1 m) or 9.84 ft (3 m) |
Computer interface | High-speed USB 2.0 | |
Computer requirements | Visit midmark.com for operating system and hardware requirements. |
Specifications are subject to change without notice.
SENSOR PART NUMBERS
- XSDS-05: Midmark Intraoral Digital Sensor System, Size 1 Sensor
- XSDS-06: Midmark Intraoral Digital Sensor System, Size 2 Sensor
PREVA DC (PARKED) Diagram
[Diagram Description: This diagram illustrates the physical dimensions and reach of the Preva DC Intraoral X-Ray system when parked. It shows various measurements in both imperial (feet/inches) and metric (cm) units. Key dimensions include:
- Overall height when parked: 33 7/8" (86 cm)
- Arm reach measurements for different models (P7018-P, P7017, P7016, P7015) are provided, indicating their extended positions. For example, P7017 has a reach of 34-5/8" (87.95 cm).
- Parked reach measurements are also given, such as P7017 reaching 44-5/8" (113.3 cm) when parked.
- Cone lengths are indicated as 8" (20 cm) and 12" (30 cm).
- A minimum ceiling height requirement of 86 5/8" (220.03 cm) is specified.