Midmark Preva Intraoral X-ray System
High-Frequency DC X-ray Unit for Dental Imaging
Introduction
The Midmark Preva Intraoral DC X-ray System is designed to enhance dental practices by integrating superior technology into a common X-ray unit. It aids practitioners in identifying cavities, visualizing tooth roots, examining developing teeth, and monitoring the overall health of the bony area surrounding teeth.
PREVA – Flawless Imaging and Enhanced Workflow
The Preva system is a reliable imaging workhorse for dental offices, detecting cavities and other problem areas with exceptional image quality and proven mechanics. It offers effortless movement, drift-free positioning, and minimizes patient stress by capturing necessary images efficiently. Midmark Preva intraoral X-ray systems utilize a high-frequency direct current (DC) method for image capture.
For advanced convenience, the Preva Plus integrates with the ClearVision® digital sensor, enabling captured images to be viewed with Progeny® Imaging Software or other popular practice management programs.
Key Features
- Effortless movement and fast one-handed positioning.
- Proprietary dual-arm braking system for stable, drift-free head positioning.
- 0.4 mm focal spot for sharp, well-defined details, aiding pathology identification with film and digital sensors.
- Easy-to-use LCD control panel with large icons for target tooth, receptor type, and patient size selection, including pre-programmed technique settings.
- Preva Plus includes ClearVision digital sensor integration and built-in storage for sensor protection.
- Available in multiple mounting configurations: wall, cabinet, or mobile, to suit operatory needs.
- Designed for fast and easy installation.
- Auto-calibration during servicing ensures consistent image quality.
Additional Features
Selectable options allow control over imaging techniques for superior diagnostic results:
- kV: 60, 65, and 70
- mA: 4, 5, 6, and 7
- Time: 0.02 seconds to 2 seconds
The Preva 2.0 model offers a high-speed USB connector for easy transition to digital imaging.
Preva Specifications
Specification | Details |
---|---|
Line voltage | 110-230 VAC +/- 10% 50 or 60 Hz |
Tube potential | 60, 65 or 70 kVp |
Tube current | 4, 5, 6, or 7 mA |
Exposure time | 20 ms to 2 seconds |
Cone length | 20 cm (8") |
Focal spot | 0.4 mm (IEC 60336) |
Duty factor | 1:15 |
Shipping weight (wall mount) | 95 lb |
Applicable documents | 21 CFR, UL, IEC, CE |
Federal regulations | 21 CFR, UL, IEC, CE |
Warranty | 2-year, limited |
Options | Exposure hand switch, 12" cone, 8" rectangular cone, Choice of 56", 66", 76" or 82" (total reach), Two-stud mounting plate, Metal stud-mounting plate |
Minimum ceiling requirement | 86.5" (219.7 cm) |
Cabinet pass through (alternate) | 66" Arm: 26.75" (W) x 47.5" (D) (68 cm x 121 cm) 76" Arm: 36.75" (W) x 47.5" (D) (93.5 cm x 121 cm) |
Mobile Base | 26.9" (W) x 36" (L) (68.3 cm x 91.4 cm) Arm reach: 56" (142 cm) Height: 76.9" (195.3 cm) |
Sensor Specifications
Specification | SIZE 1 | SIZE 2 |
---|---|---|
Film size equivalent | 24 x 27 x 5.5 mm | 32 x 43 x 5.5 mm |
Active area | 30 x 20 mm | 36 x 26 mm |
Sensor cable | 90 cm, 3 m | |
Computer interface | High-speed USB 2.0 | |
Computer requirements | Refer to midmark.com for operating system and hardware requirements. |
Specifications are subject to change without notice.
ClearVision® Integrated Digital Sensor System
- XSDN-01: ClearVision® Digital Sensor System Size 1 sensor
- XSDN-02: ClearVision® Digital Sensor System Size 2 sensor
Ordering Guide
The following tables detail available configurations for the Preva Intraoral X-ray System and ClearVision Sensors.
Single Stud Mount
Reach | Sensor | PREVA DC | PREVA 2.0 | PREVA PLUS |
---|---|---|---|---|
76" Reach | #1 Sensor | P7017 | DCD7-G1N | DCD7-G1N/S1 |
#2 Sensor | DCD7-G1N/S2 | DCD7-G1N/S2 | ||
66" Reach | #1 Sensor | P7016 | DCD6-G1N | DCD6-G1N/S1 |
#2 Sensor | DCD6-G1N/S2 | DCD6-G1N/S2 | ||
56" Reach | #1 Sensor | P7015 | DCD5-G1N | DCD5-G1N/S1 |
#2 Sensor | DCD5-G1N/S2 | DCD5-G1N/S2 |
Double Stud Mount
Reach | Sensor | PREVA DC | PREVA 2.0 | PREVA PLUS |
---|---|---|---|---|
82" Reach | #1 Sensor | P7018-P | DCD8-G2N | DCD8-G2N/S1 |
#2 Sensor | DCD8-G2N/S2 | DCD8-G2N/S2 | ||
76" Reach | #1 Sensor | P7017-P | DCD7-G2N | DCD7-G2N/S1 |
#2 Sensor | DCD7-G2N/S2 | DCD7-G2N/S2 | ||
66" Reach | #1 Sensor | P7016-P | DCD6-G2N | DCD6-G2N/S1 |
#2 Sensor | DCD6-G2N/S2 | DCD6-G2N/S2 | ||
56" Reach | #1 Sensor | P7015-P | DCD5-G2N | DCD5-G2N/S1 |
#2 Sensor | DCD5-G2N/S2 | DCD5-G2N/S2 |
Mobile
Configuration | PREVA DC | PREVA 2.0 | PREVA PLUS |
---|---|---|---|
Mobile | P7017GM | DCDM-G0N/H | DCDM-G0N/H/S1 |
DCDM-G0N/H/S2 |
Diagram Descriptions
Preva DC (Parked) Configuration: A diagram illustrates the spatial requirements and reach of the Preva DC system when parked. It shows various reach options (e.g., 82" Reach Parked 50 5/8" (129 cm) for P7018-P, 76" Reach Parked 44 5/8" (113.3 cm) for P7017) and indicates the minimum ceiling requirement of 86.5" (219.7 cm).
X-ray Unit Image: A photograph depicts the Midmark Preva intraoral X-ray system, highlighting its articulated arm and tube head. The system is shown in a typical dental operatory setting.
Contact and Company Information
Midmark is an ISO 13485 and ISO 9001 Certified Company.
For more information or a demonstration, contact your Midmark dealer or call:
- 1-800-MIDMARK
- Fax: 1-877-725-6495
Outside the U.S.A. call:
- 1-937-526-3662
- Fax: 1-937-526-8214
Visit the Midmark website at midmark.com.
© 2018 Midmark Corporation, Dayton, OH. Products subject to improvement changes without notice.
For additional spec drawings, review the Preva Dental X-ray System Installation and Service Manual at midmark.com.