LevelPro® — ProScan®3 Series

Continuous Radar Level Sensor (80GHz)

Quick Start Manual

Programming

STEPS

Home Screen

⏎ OK

DISPLAY

192.5 IN

OPERATION

Home Screen

⌚ Approx. 30 secs for the level reading to display

Level Searching...

1

Main Menu

⏎ OK

DISPLAY

Main Menu

⏎ OK

→ User Para.

→ Factory Para.

OPERATION

STEP 1

Select User Parameter Press OK

2

User Parameters

⏎ OK

DISPLAY

User Para.

→ Basic Setup

Measure Setup

Backup Para.

OPERATION

STEP 2

Select Basic Setup Press OK

3

Range Settings

⏎ OK

DISPLAY

Basic Setup

Range: 5000 mm

Offset: 10 mm

Pos 4ma: 0 mm

OPERATION

STEP 3

Set Range Press OK

• Range: Distance from Sensor Tip to Bottom of Tank.

Note:

↗ Use ◀ to move cursor. 5000

↗ Use ▶ to change digits.

Cursor

Range

4

4-20mA Settings

ESC x 3 to go back to Home Screen

DISPLAY

Basic Setup

Pos 4ma: 0 mm

OPERATION

STEP 4

Set 4mA Press OK

• 4mA: Low Level | Default = 0

20mA (High)

Set 20mA Press OK

• Pos 20ma: 3000 mm • 20mA: High Level | Should be lower than Range

Blind: 100 mm

Note:

↗ Use ◀ to move cursor. 3000

↗ Use ▶ to change digits.

Cursor

4mA (Low)

Bluetooth Application Settings

Install RadarMe App in your Device

App Store

Google Play

Operation

Make sure your Device Bluetooth is ON

Open RadarMe App in the Device

Click Device List Menu

Select ICON12XXX from the List

ProScan3 Connected

Setting Display Unit

Home Screen

Level(m) 35.7873

Distance(m) 84.2124

Current(mA) 8.771

Percentage(%) 29.82

Running State 0

Update Time 2023/11/21 16:29:36

SET Menu

⏎ Click Set Button

System Settings Menu

⏎ Select System Settings

System Settings Menu

⏎ Click Unit Drop Down Arrow

Home Screen

Level(inch) 35.7873

Distance(inch) 84.2124

Current(mA) 8.771

Percentage(%) 29.82

Running State 0

Update Time 2023/11/21 16:29:36

⏎ Select Unit (m | inch)

Unit Changed Successfully!

Setting Range

Home Screen

Level(inch) 35.7873

Distance(inch) 84.2124

Current(mA) 8.771

Percentage(%) 29.82

Running State 0

Update Time 2023/11/21 16:29:36

Set

⏎ Click Set Button

Basic Parameters

⏎ Select Basic Parameters

Set Range Value

E.g. Range Value = 120 (inch)

Range 120 (inch)

Diagram: Tank with level indicated.

Range 120 (inch)

Setting Level

Basic Parameters

Range(inch) 120.00

Migration Amount(inch) 0.0

4mA Location(inch) 0.0

20mA Location(inch) 119.9998

Blind Area(inch) 4.0157

Damping Time 50

Device Address 1

Baud Rate 9600

⏎ READ ⏎ SET ⏎ BACKUP ⏎ RESTORE

Set 4mA Location

4mA (Low Level) = 0

4 mA

Basic Parameters

Range(inch) 120.00

Migration Amount(inch) 0.0

4mA Location(inch) 0.0

20mA Location(inch) 110.00

Blind Area(inch) 4.00

Damping Time 50

Device Address 1

Baud Rate 9600

⏎ READ ⏎ SET ⏎ BACKUP ⏎ RESTORE

Set 20mA Location

20mA (High Level) = 110(inch)

20 mA

Diagram: Tank showing 4mA and 20mA levels.

4 mA (Low Level)

20 mA (High Level)

Setting Parameters

Basic Parameters

Range(inch) 120.00

Migration Amount(inch) 0.0

4mA Location(inch) 0.0

20mA Location(inch) 110.00

Blind Area(inch) 4.00

Damping Time 50

Device Address 1

Baud Rate 9600

⏎ READ ⏎ SET ⏎ BACKUP ⏎ RESTORE

Set Blind Area

E.g. Blind Area = 4.00(Inch)

Basic Parameters

Range(inch) 120.00

Migration Amount(inch) 0.0

4mA Location(inch) 0.0

20mA Location(inch) 110.00

Blind Area(inch) 4.00

Damping Time 10

Device Address 1

Baud Rate 9600

⏎ READ ⏎ SET ⏎ BACKUP ⏎ RESTORE

Set Damping Time

E.g. Damping Time = 10(sec)

Basic Parameters

Range(inch) 120.00

Migration Amount(inch) 0.0

4mA Location(inch) 0.0

20mA Location(inch) 110.00

Blind Area(inch) 4.00

Damping Time 10

Device Address 1

Baud Rate 9600

⏎ READ ⏎ SET ⏎ BACKUP ⏎ RESTORE

Click Set Button to Save the Parameters

Diagram: Tank showing measurement location and range.

Measurement Location 100%

Range 0%

Wiring

Remove cover and display to access wiring terminals.

Diagram: Sensor unit with cover removed, showing wiring terminals.

LevelPro

192.5 IN

⏎ OPEN ⏎ LOCK ⏎ ESC ⏎ OK

Diagram: Close-up of wiring terminals.

Loop Powered Terminals

Built-in Level

RS485 Terminals

24VDC

RS485

Warranty, Returns and Limitations

Warranty

Icon Process Controls Ltd warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service in accordance with instructions furnished by Icon Process Controls Ltd for a period of one year from the date of sale of such products. Icon Process Controls Ltd obligation under this warranty is solely and exclusively limited to the repair or replacement, at Icon Process Controls Ltd option, of the products or components, which Icon Process Controls Ltd examination determines to its satisfaction to be defective in material or workmanship within the warranty period. Icon Process Controls Ltd must be notified pursuant to the instructions below of any claim under this warranty within thirty (30) days of any claimed lack of conformity of the product. Any product repaired under this warranty will be warranted only for the remainder of the original warranty period. Any product provided as a replacement under this warranty will be warranted for the one year from the date of replacement.

Returns

Products cannot be returned to Icon Process Controls Ltd without prior authorization. To return a product that is thought to be defective, go to www.iconprocon.com, and submit a customer return (MRA) request form and follow the instructions therein. All warranty and non-warranty product returns to Icon Process Controls Ltd must be shipped prepaid and insured. Icon Process Controls Ltd will not be responsible for any products lost or damaged in shipment.

Limitations

This warranty does not apply to products which: 1) are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures outlined above; 2) have been subjected to electrical, mechanical or chemical damage due to improper, accidental or negligent use; 3) have been modified or altered; 4) anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repair; 5) have been involved in accidents or natural disasters; or 6) are damaged during return shipment to Icon Process Controls Ltd reserves the right to unilaterally waive this warranty and dispose of any product returned to Icon Process Controls Ltd where: 1) there is evidence of a potentially hazardous material present with the product; or 2) the product has remained unclaimed at Icon Process Controls Ltd for more than 30 days after Icon Process Controls Ltd has dutifully requested disposition. This warranty contains the sole express warranty made by Icon Process Controls Ltd in connection with its products. ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL Icon Process Controls Ltd BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon Process Controls Ltd. This warranty will be interpreted pursuant to the laws of the province of Ontario, Canada.

If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other provision of this warranty.

For additional product documentation and technical support visit: www.iconprocon.com | e-mail: sales@iconprocon.com or support@iconprocon.com | Ph: 905.469.9283

Models: ProScan 3 Series Continuous Radar Level Sensor, ProScan 3 Series, Continuous Radar Level Sensor, Radar Level Sensor, Level Sensor

File Info : application/pdf, 6 Pages, 1.43MB

PDF preview unavailable. Download the PDF instead.

24-231 ps3 quickstartmanual1

References

Adobe PDF Library 17.0 Adobe InDesign 19.5 (Windows)

Related Documents

Preview LevelPro® ProScan®3 Series Continuous Radar Level Sensor (80GHz) Quick Start Manual
Quick start guide for the ICON Process Controls LevelPro® ProScan®3 Series 80GHz continuous radar level sensor, covering programming, Bluetooth setup, display unit settings, wiring, and warranty information.
Preview LevelPro® - TankPro® Series Submersible Level Sensor Transmitter Manual
User manual for the ICON Process Controls LevelPro® - TankPro® Series submersible level sensor transmitter, detailing specifications, installation, operation, and troubleshooting for accurate liquid level measurement in various industrial applications.
Preview ICON Process Controls Product Catalogue
A comprehensive product catalogue from ICON Process Controls, featuring a wide range of instrumentation equipment for flow, liquid level, analytical, pressure, and leak detection applications. Includes detailed product specifications, features, and applications for various series like Truflo, LevelPro, IZON, ProCon, and more.
Preview LevelPro PLF Magnetic Float Level Switch Assembly Datasheet
Datasheet for the LevelPro PLF Magnetic Float Level Switch Assembly by ICON Process Controls. Features include a 6"-72" range, up to 8 relay contacts, NEMA 4X enclosure, and superior chemical resistance. Suitable for various industrial applications.
Preview Icon Process Controls Specification Guide
A comprehensive specification guide for Icon Process Controls' corrosion-free process instrumentation equipment, detailing various flow meters, level sensors, and pressure gauges.
Preview LevelPro ShoPro SP100 Level Display Controller Manual
User manual for the LevelPro ShoPro SP100 Level Display Controller, detailing features, specifications, installation, wiring, and programming.
Preview ProCon C750 Series Toroidal Conductivity Sensor Quick Start Manual
Quick start guide for the ProCon C750 Series Toroidal Conductivity Sensor by Icon Process Controls, detailing safety information, introduction, technical specifications, wiring, installation methods (flange, tee, immersion), model selection, and warranty details.
Preview LevelPro® TVF Series Quick Start Manual - Flow Display, Controller, Batcher
Comprehensive quick start guide for the ICON LevelPro® TVF Series, detailing its functions as a flow display, controller, and batcher. Covers specifications, front panel layout, wiring diagrams, various flow meter connections, and step-by-step programming instructions for key features.