User Guide for ICON PROCESS CONTROLS models including: ProScan 3 Series Continuous Radar Level Sensor, ProScan 3 Series, Continuous Radar Level Sensor, Radar Level Sensor, Level Sensor
ProScan 3 Continuous Radar Level Sensor/Transmitter | ICON Process Controls
File Info : application/pdf, 6 Pages, 1.00MB
DocumentDocumentLevelPro® -- ProScan®3 Series Continuous Radar Level Sensor (80GHz) Quick Start Manual Read the user's manual carefully before starting to use the unit. Producer reserves the right to implement changes without prior notice. 24-0231 © Icon Process Controls Ltd. 1 LevelPro® -- ProScan®3 Series Continuous Radar Level Sensor (80GHz) Programming STEPS 1 Home Screen OK DISPLAY 192.5 IN Home Screen Use to move to next selection OPERATION 2 Main Menu Main Menu User Para. Select User Parameter & Press OK OK Factory Para. 3 User Parameters User Para. Basic Setup Measure Setup OK Backup Para. Select Basic Setup & Press OK 4 Range Settings Basic Setup Range : 5000 Offset : 10 mm mm Set Range using OK Pos 4ma: 0 mm & Press OK 5 4-20mA Settings Basic Setup Pos 4ma: 0 mm Set 4mA (Low Level) & 20mA (High Level) values. Pos 20ma: 3000 mm Use to change values & Press OK OK Blind: 100 mm Basic Setup 6 Measurement Type Blind: 150 mm Set Measurement Type : Level | Display ESC x 3 ShowType: Level Damping Time: 10 Use to change & Press OK Distance Sensor to Top of Liquid Level Height of Liquid 24-0231 © Icon Process Controls Ltd. Range 20 mA 4 mA Measurement Location 100% Range 0% 2 LevelPro® -- ProScan®3 Series Continuous Radar Level Sensor (80GHz) Bluetooth Applicatio®n Settings Install RadarMe App in your Device RadarMe RadarMe Make sure your Device Bluetooth is ON Home RadarMe RadarMe Open RadarMe App in the Device Level(m) 0 Distance(m) 0 Current(mA) 0 Percentage(%) 0 Running State 0 Update Time 2023/11/21 16:29:36 Home Curve Set Click Device List Menu Home Level(m) Distance(m) Current(mA) Percentage(%) Running State UPDATE DEVICE LIST ICON12XXX 35.7873 84.2124 8.771 29.82 0 Update Time 2023/11/21 16:29:36 Home Curve Set Select ICON12XXX from the List Home ICON12XXX Level(m) Distance(m) Current(mA) Percentage(%) Running State 35.7873 84.2124 8.771 29.82 0 Update Time 2023/11/21 16:29:36 Home Curve Set ProScan3 Connected Setting Display Unit Home Screen Home ICON12XXX Level(m) Distance(m) Current(mA) Percentage(%) Running State 35.7873 84.2124 8.771 29.82 0 Update Time 2023/11/21 16:29:36 SET Menu Set ICON12XXX Basic Parameters Advanced Parameters System Settings System Settings Menu System Settings ICON12XXX Privacy Policy use unit m Home Curve Set Click Set Button Home Curve Set Select System Settings RESTORE FACTORY MODE Click Unit Drop Down Arrow System Settings Menu System Settings ICON12XXX Privacy Policy use unit inmch inch RESTORE FACTORY MODE Select Unit (m | inch) Home Screen Home ICON12XXX Level(inch) Distance(inch) Current(mA) Percentage(%) Running State 35.7873 84.2124 8.771 29.82 0 Update Time 2023/11/21 16:29:36 Home Curve Set Unit Changed Successfully! 24-0231 © Icon Process Controls Ltd. 3 LevelPro® -- ProScan®3 Series Continuous Radar Level Sensor (80GHz) Setting Range Home ICON12XXX Level(inch) Distance(inch) Current(mA) Percentage(%) Running State 35.7873 84.2124 8.771 29.82 0 Update Time 2023/11/21 16:29:36 Set ICON12XXX Basic Parameters Advanced Parameters System Settings Home Curve Set Click Set Button Home Curve Set Select Basic Parameters Setting Level Basic Parameters ICON12XXX Range(inch) Migration Amount(inch) 4mA Location(inch) 20mA Location(inch) Blind Area(inch) Damping Time Device Address Baud Rate READ SET 120.00 0.0 0.0 119.9998 4.0157 50 1 9600 BACKUP RESTORE Set 4mA Location 4mA (Low Level) = 0 4 mA Setting Parameters Basic Parameters ICON12XXX Range(inch) Migration Amount(inch) 4mA Location(inch) 20mA Location(inch) Blind Area(inch) Damping Time Device Address Baud Rate READ SET 120.00 0.0 0.0 110.00 4.00 50 1 9600 BACKUP RESTORE Basic Parameters ICON12XXX Range(inch) Migration Amount(inch) 4mA Location(inch) 20mA Location(inch) Blind Area(inch) Damping Time Device Address Baud Rate READ SET 120.00 0.0 0.0 110.00 4.00 10 1 9600 BACKUP RESTORE Set Blind Area E.g. Blind Area = 4.00(Inch) Set Damping Time E.g. Damping Time = 10(sec) 24-0231 © Icon Process Controls Ltd. Basic Parameters ICON12XXX Range(inch) Migration Amount(inch) 4mA Location(inch) 20mA Location(inch) Blind Area(inch) Damping Time Device Address Baud Rate READ SET 120.00 0.0 0.0 119.9998 4.0157 50 1 9600 BACKUP RESTORE Set Range Value E.g. Range Value = 120 (inch) Range 120 (inch) Basic Parameters ICON12XXX Range(inch) Migration Amount(inch) 4mA Location(inch) 20mA Location(inch) Blind Area(inch) Damping Time Device Address Baud Rate 120.00 0.0 0.0 110.00 4.0157 50 1 9600 20 mA READ SET BACKUP RESTORE 4 mA Set 20mA Location 20mA (High Level) = 110(inch) Level Basic Parameters ICON12XXX Range(inch) Migration Amount(inch) 4mA Location(inch) 20mA Location(inch) Blind Area(inch) Damping Time Device Address Baud Rate READ SET 120.00 0.0 0.0 110.00 4.00 10 1 9600 BACKUP RESTORE Click Set Button to Save the Parameters 20 mA 4 mA Measurement Location Max Config 100% Range 0% 4 LOCK LOCK LOCK LevelPro® -- ProScan®3 Series Continuous Radar Level Sensor (80GHz) Basic Parameters ICON12XXX Range(inch) Migration Amount(inch) 4mA Location(inch) 20mA Location(inch) Blind Area(inch) Damping Time Device Address Baud Rate READ SET 120.00 0.0 0.0 110.00 4.00 10 1 9600 BACKUP RESTORE Back to Setting Menu Wiring 01 Set ICON12XXX Basic Parameters Advanced Parameters System Settings Home Curve Set Click Home Button to Show Home Screen Home ICON12XXX Level(inch) Distance(inch) Current(mA) Percentage(%) Running State 35.7873 84.2124 8.771 29.82 0 Update Time 2023/11/21 16:29:36 Home Curve Set 02 03 R OPEN ProScan® 3 Series 24VDC RS485 10.562m ESC OOKK ESC OPEN ProScan ®3 Series R OK Bluetooth Settings Video Tutorial ESC OPEN ProScan ®3 Series R OK 24VDC RS48 Rotate Lid Anti-clockwise to Open and Clockwise to Close 04 05 Built-in Level 24VDC RS485 Open Lid Rotate Display Anti-clockwise to Open and Clockwise to Close. 06 24VDC Positive (+) Negative (-) 24VDC RS485 Remove Cord Grip 24-0231 © Icon Process Controls Ltd. Insert Cable into Cord Grip Positive (+) and Negative (-) Terminals are for connection to a 24 VDC power supply 5 LevelPro® -- ProScan®3 Series Continuous Radar Level Sensor (80GHz) Warranty, Returns and Limitations Warranty Icon Process Controls Ltd warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service in accordance with instructions furnished by Icon Process Controls Ltd for a period of one year from the date of sale of such products. Icon Process Controls Ltd obligation under this warranty is solely and exclusively limited to the repair or replacement, at Icon Process Controls Ltd option, of the products or components, which Icon Process Controls Ltd examination determines to its satisfaction to be defective in material or workmanship within the warranty period. Icon Process Controls Ltd must be notified pursuant to the instructions below of any claim under this warranty within thirty (30) days of any claimed lack of conformity of the product. Any product repaired under this warranty will be warranted only for the remainder of the original warranty period. Any product provided as a replacement under this warranty will be warranted for the one year from the date of replacement. Returns Products cannot be returned to Icon Process Controls Ltd without prior authorization. To return a product that is thought to be defective, go to www.iconprocon.com, and submit a customer return (MRA) request form and follow the instructions therein. All warranty and non-warranty product returns to Icon Process Controls Ltd must be shipped prepaid and insured. Icon Process Controls Ltd will not be responsible for any products lost or damaged in shipment. Limitations This warranty does not apply to products which: 1) are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures outlined above; 2) have been subjected to electrical, mechanical or chemical damage due to improper, accidental or negligent use; 3) have been modified or altered; 4) anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repair; 5) have been involved in accidents or natural disasters; or 6) are damaged during return shipment to Icon Process Controls Ltd reserves the right to unilaterally waive this warranty and dispose of any product returned to Icon Process Controls Ltd where: 1) there is evidence of a potentially hazardous material present with the product; or 2) the product has remained unclaimed at Icon Process Controls Ltd for more than 30 days after Icon Process Controls Ltd has dutifully requested disposition. This warranty contains the sole express warranty made by Icon Process Controls Ltd in connection with its products. ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL Icon Process Controls Ltd BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon Process Controls Ltd. This warranty will be interpreted pursuant to the laws of the province of Ontario, Canada. If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other provision of this warranty. For additional product documentation and technical support visit: www.iconprocon.com | e-mail: sales@iconprocon.com or support@iconprocon.com | Ph: 905.469.9283 24-0231 © Icon Process Controls Ltd. 6