ROVSUN

USE & CARE GUIDE

Product: 6,000 BTU Window Air Conditioner

Introduction

Thank you for purchasing the ROVSUN 6,000 BTU Window Air Conditioner. This guide provides essential information for the safe installation, operation, and maintenance of your new appliance. Please read this manual carefully and store it in a safe place for future reference.

For any questions or assistance, please do not hesitate to contact us. Your feedback is vital to us, and we are committed to providing the best possible service. For more details, please contact us via email at support@rovsun.com. Please include your seller's Order # in the subject line so we can find your order and better assist you.

Important Safety Instructions

Before installing and using your air conditioner, please read this owner's manual carefully. Your safety and the safety of others is very important.

⚠️ WARNING: To reduce the risk of fire, electrical shock, or injury, follow the basic precautions below:
  • ✔️ Plug into a grounded 3-prong outlet.
  • Do not remove the ground prong.
  • Do not use a plug adapter.
  • Do not use an extension cord.
  • ? Unplug the air conditioner before servicing.
  • ?‍?‍? Use two or more people to move and install the air conditioner.

⚠️ This is a safety alert symbol. It alerts you to potential hazards that can harm you or others or even cause death. All safety messages will directly follow the safety alert symbol and/or the words "DANGER" or "WARNING".

? DANGER

⚠️ WARNING: Failure to immediately follow these instructions may cause serious injury or even death.

All safety messages alert you of potential hazards, how to reduce the chance of injury, and what can happen if instructions are not followed correctly.

Introduction to Refrigerants R32

The refrigerants used for air conditioners are environmentally friendly hydrocarbons R32. This refrigerant is combustible and odorless. Moreover, it can burn and explode under certain conditions. However, there will be no risk of burning and explosion if you comply with the following guidelines to install your air conditioner in a room with an appropriate area and use it correctly. Compared with ordinary refrigerants, Refrigerant R32 is environmentally friendly and does not destroy the ozone layer, and its value of greenhouse effect is also very low.

Room Area Requirements for Air Conditioner with Refrigerant R32

Refrigerant Capacity (Btu) Room Area
R32 <9K Above 4m²
<12K Above 4m²
<18K Above 15m²
<24K Above 25m²
⚠️ Warnings:
  • Please read the manual before installation, using, and maintenance.
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • Do not pierce or burn the appliance.
  • The appliance shall be stored in a room without continuously operating sources (for example: open flames, an operating ignition gas appliance, or an operating electric heater).
  • Please contact the nearest after-sale service center when maintenance is necessary. At the time of maintenance, the maintenance personnel must strictly comply with the Operation Manual provided by the corresponding manufacturer, and any non-professional is prohibited from maintaining the air conditioner.
  • The handling, installation, storage, servicing, and disposal must comply with the provisions of gas-related national laws and regulations, and also national wiring regulations.
  • It is necessary to clear away the refrigerant in the system when maintaining or scrapping an air conditioner. Be aware that refrigerants may not contain an odor.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • Unit operation limits: Outdoor side 61~110°F, 80%RH; indoor side 61~90°F, 80%RH.

Electrical Requirements

⚠️

The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit (when facing the front). Specific electrical requirements are listed in the chart below. Follow the requirements below for the type of plug on the power supply cord.

Wiring Requirements

Power Supply Cord: [Image description: A three-prong power plug.]

Recommended Ground Method

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3-prong power supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3-prong outlet and grounded in accordance with all local codes and ordinances. If a 3-prong outlet is not available, it is the customer's responsibility to have a properly grounded 3-prong outlet installed by a qualified electrician.

It is the customer's responsibility:

Copies of the standards listed may be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, Massachusetts 02269.

LCDI Power Cord and Plug

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.

The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-energized until the device has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazard if exposed. The cord shield must not be connected to ground or to any exposed metal.

The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test the plug:

  1. Plug power cord into a wall outlet.
  2. Press the [Test Button]. The circuit should trip and cut all power to the air conditioner.
  3. Press the [Reset Button] for use.

If a test is performed and the indicator light remains ON, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Customer Service for troubleshooting recommendations.

Packing List

(Appearance may vary)

Image Description Part Quantity
[Image: Window Air Conditioner] Window Air Conditioner 1
[Image: Remote Control] Remote Control 1
[Image: Top Mounting Rail] Top Mounting Rail (Putting on the top of package foam with sponge) 1
[Image: Lock Frame] Lock Frame 2
[Image: Filler Panels] Filler Panels (With "Left" & "Right" on the front face) 2
[Image: Sash Lock (Two holes)] Sash Lock (Two holes) 1
[Image: Window Sash Seal (Sponge)] Window Sash Seal (Sponge) 1
[Image: 3/8" Screw] 3/8" Screws 4
[Image: 1/2" Screw] 1/2" Screws 3
[Image: 3/4" Screw] 3/4" Screws 4
[Image: Foam Top Window Gasket] Foam Top Window Gasket (Thin sponge for backup using) 1
[Image: Battery] Battery 2

Installation & Assembly Instructions

Some assembly is required for your new air conditioner. Please read and follow these instructions carefully.

  1. This air conditioner is designed to be installed in a standard double-hung window with a window width between 23" and 36" (584 mm - 914 mm).
  2. The air conditioner can be installed without the accordion panels to fit in a narrow window opening. See the window dimensions.
  3. The Lower Sash (the lower part of the window that moves up and down) must allow for 14.5" of vertical clearance when open.
  4. All supporting parts must be secured to firm wood, masonry, or metal.
  5. The electrical outlet must be within reach of the power cord.

FIG. 1: Diagram illustrating window dimensions for installation, showing a width requirement between 23" and 36" (584 mm - 914 mm) and a minimum vertical clearance of 14.5" (368mm). It shows the interior wall, exterior wall, and window sill.

NOTE: Save the product packaging and installation instructions for future reference. Store the air conditioner in the product box when not in use for an extended period of time.

Top Rail Assembly

The top rail must be assembled prior to installing the air conditioner in the window.

Tools Needed: Phillips Head Screw Driver

Top Rail Hardware QTY
3/8" Screw 4
Top Rail 1

FIG. A: Diagram showing the Top Rail and Box.

FIG. B: Diagram showing alignment of the Top Rail with the unit.

Attaching the Top Rail to the Air Conditioner

  1. Remove the air conditioner from the box and place on a hard and flat surface.
  2. Remove top rail from the top of the packaging material as shown in FIG. A.
  3. Align the hole in the top rail with those in the top of the unit as shown in FIG. B.
  4. Secure the top rail to the unit with the 3/8" screws as shown in FIG. C.

FIG. C: Diagram showing the Top Rail secured to the unit with screws.

CAUTION: When handling the unit, be careful to avoid cuts from the sharp metal edges and aluminum fins on the front and rear coils.

NOTE: For safety reasons, all 4 screws must be used to attach the top rail.

Accordion Panel Installation

Now that you have installed the top rail, you can now install the accordion panels on each side.

  1. Place the air conditioner on a hard flat surface.
  2. Locate the accordion panels in the box.
  3. Gently pull the free end of the accordion panel (See FIG. 2). Do this for both panels.

FIG. 2: Illustration of pulling the accordion panel.

  1. Slide the free end of the accordion panel into the side panel of the air conditioner (See FIG. 3). Do this for each side.

FIG. 3: Illustration of sliding the accordion panel into the side panel.

  1. Once the accordion panels are slid into place, adjust the top and bottom rails of the accordion panels into the top and bottom rails of the air conditioner (See FIG. 4).

FIG. 4: Illustration showing adjustment of accordion panel rails.

Storm Window Requirements

A storm window frame will not allow the air conditioner to tilt properly, which in turn will keep it from draining properly. To adjust for this, attach a board or piece of wood to the sill. The board or wood piece should have a depth of at least 1 1/2". Make sure the board or piece of wood is approximately 1/2" higher than the storm window frame. This will allow the air conditioner to tilt enough for proper drainage. (See FIG. 5).

FIG. 5: Diagram showing a storm window frame, sash, and a board attached to the sill, indicating the required height difference for drainage.

Placing the Unit Inside a Window

  1. Place the air conditioner on the sill with the bottom mounting rail against its back edge. Center the air conditioner and close the window securely behind the top mounting rail. The air conditioner should be slightly tilted to the outside area. Use a level; about a 1/3 bubble will be the correct case slant to the outside. (See FIG. 6 & FIG. 7) (It is suggested to keep a downward angle to let accumulated rain water drain out from the back side of the unit bottom.)

FIG. 6: Diagram showing the bottom rail and window sill.

FIG. 7: Diagram illustrating the correct tilt angle for drainage.

  1. Once the air conditioner is placed, extend both the left and right accordion panels to the width of the window.

FIG. 8: Illustration of extending accordion panels to the window width.

Frame Lock, Sash Lock, and Foam Seal Installation

MOUNTING HARDWARE

Hardware Qty
3/4" Screws 4
1/2" Screws 3
Frame Lock 2
Sash Lock 1

Tools Needed: Phillips Head Screw Driver, Drill (if pilot holes are needed)

  1. Place the frame lock between the extended accordion panels and the window sill as shown in FIG. 9. Screw a 3/4" (19 mm) locking screw through the frame lock and into the window sill. (FIG. 10)

FIG. 9: Illustration showing placement of the frame lock.

FIG. 10: Illustration showing screwing the frame lock into the window sill.

  1. Drive 1/2" screws into the top of the accordion panel frame and the top rail to securely attach the window air conditioner to the lower sash. (See FIG. 11/12)

FIG. 11 & FIG. 12: Illustrations showing screws attaching the accordion panel frame and top rail to the lower sash.

  1. To secure the lower sash into place, use the sash lock and a 3/4" screw as shown below. (See FIG. 13)

FIG. 13: Illustration showing the sash lock securing the lower sash.

  1. For added insulation, cut the supplied insulation foam to the width of the window. Insert the foam between the window sashes to prevent air and objects from getting into the room. (See FIG. 14)

FIG. 14: Illustration showing insulation foam inserted between window sashes.

Removing the Air Conditioner from the Window

  1. Turn the air conditioner off and unplug the power cord.
  2. Remove the sash seal from between windows, and unscrew sash lock.
  3. Remove the screws installed through the frame and frame lock.
  4. Close (slide) the side panels into frame.
  5. Keeping a firm grip on the air conditioner, raise the sash and carefully "rock" air conditioner backward to drain any condensate water in the base of the unit. Be careful not to spill any remaining water while lifting the unit from the window.
  6. Store parts WITH the air conditioner in the box.

Installation & Assembly Instructions - Introduction to Refrigerants R32

Before installing the appliance, you must read the manual carefully to get the safety information and notes.

Requirements for the total weight of filled refrigerant and the area of a room to be equipped with an air conditioner are shown in the following Tables GG.1 and GG.2.

The maximum charge and the required minimum floor area

m₁ = (4 m³) x LFL, m₂ = (26 m³) x LFL, m₃ = (130 m³) x LFL

Where LFL is the lower flammable limit in kg/m³, R32 LFL is 0.306 kg/m³.

For the appliances with a charge amount m₁ < M < m₂:

The maximum charge in a room shall be in accordance with the following: mmax = 2.5 x (LFL)(5/4) x h0 x (A)1/2

The required minimum floor area Amin to install an appliance with refrigerant charge M (kg) shall be in accordance with the following: Amin = (M / (2.5 x (LFL)(5/4) x h0))²

Where:

Table GG.1 Maximum charge (kg)

Category LFL (kg/m³) h0 (m) Floor area(m²)
7 10 15 20 30 50
R32 0.306 0.6 0.68 0.9 1.08 1.32 1.53 1.87 2.41
1 1.14 1.51 1.8 2.2 2.54 3.12 4.02
1.8 2.05 2.71 3.24 3.97 4.58 5.61 7.254
2.2 2.5 3.31 3.96 4.85 5.6 6.86 8.85

Table GG.2 Minimum room area (m²)

Category LFL (kg/m³) h0 (m) Charge amount (M) ( kg)
1.224 kg 1.836 kg 2.448 kg 3.672 kg 4.896 kg 6.12 kg 7.956 kg
R32 0.306 0.6 29 51 116 206 321 543
1 10 19 42 74 116 196
1.8 3 6 13 23 36 60
2.2 2 4 9 15 24 40

Site Safety

Operation Safety

Installation Safety

The left picture is the schematic diagram of a refrigerant leak detector.

Please note that:

  1. The installation site should be in a well-ventilated condition.
  2. The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire or welding, smoking, drying oven, or any other heat source higher than 548°C which easily produces open fire.
  3. When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wearing anti-static clothing and/or gloves.
  4. It is necessary to choose the site convenient for installation or maintenance wherein the air inlets and outlets of the indoor and outdoor units should not be surrounded by obstacles or close to any heat source or combustible and/or explosive environment.
  5. If the indoor unit suffers refrigerant leak during the installation, all personnel should leave until the refrigerant leaks completely for 15 minutes. If the product is damaged, it is a must to carry such damaged product back to the maintenance station, and it is prohibited to weld the refrigerant pipe or conduct other operations on the user's site.
  6. It is necessary to choose the place where the inlet and outlet air of the indoor unit is even.
  7. It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets, kitchen cabinet, bed, sofa, and other valuables right under the lines on two sides of the indoor unit, and also prevent mechanical damage from occurring.

Using Your Air Conditioner

Manual Control Panel

[Image description: Diagram of the air conditioner control panel with numbered buttons.]

  1. Digital Display: When the timer is not in use, the operation mode and the set temperature will be displayed. Time will be displayed under the timer setting.
  2. Mode Button: Press the mode button to cycle through the various modes: Cool, Dry, Fan, and Auto.
    • Cool Mode: The cooling function allows the air conditioner to cool the room and at the same time reduces humidity. Press the MODE button to activate the cooling function. To optimize this function, adjust the temperature by pressing the up and down arrows and the speed by pressing the Fan Speed button.
    • Dry Mode: This function reduces the humidity of the air to make the room more comfortable. Press the MODE button to set the DRY mode. An automatic function of alternating cooling cycles and air fan is activated.
    • Fan Mode: This function only works when the air conditioner is vented. Press the MODE button to set the FAN mode. With pressing the FAN SPEED button, the speed changes in the following sequence: Hi, Med, and Lo in FAN mode.
    • Auto Mode: In AUTO mode, the unit automatically chooses the mode of operation (COOL, DRY, or FAN). In this mode, the temperature is set automatically according to the room temperature (Room temperature is determined by the temperature sensor located in the indoor unit).
  3. and Buttons: Use these buttons on the control panel and remote to increase or decrease the Set Temperature or Timer. Temperature range: 61°F ~ 88°F or 16°C ~ 31°C.
  4. ? Sleep Button: Press the SLEEP button; all of the display lights will turn off after a while, but the Sleep light is always on. In SLEEP mode, the air conditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. The set temperature will automatically raise every 30-60 minutes, and at most change six times until the set temperature is 81°F or 82°F.

Normal Operating Sounds

Control Panel Buttons

  1. ? Eco Button: When the unit is in ECO mode, the light will turn on. In ECO mode, the unit will turn off once the room is cooled to the user-set temperature. The unit will turn back on when the room temperature rises above the user-set temperature. Before the compressor starts, the fan motor will run for a while, then it will stop for a while, and will repeat to provide a much more comfortable feeling and save energy.
  2. Power Button: Turn the air conditioner on and off.
  3. ? Filter Button: When the Filter Check light is off, it is not necessary to press the Filter Check button. When the Filter Check light is on, you can turn off the light by pressing the Filter Check button. After the fan motor works for 500 total hours, the Filter Check light will turn on to remind the user to clean the filter.
  4. Timer Button: Use these buttons on the control panel and remote to set the Timer.
    • Timer Off: The timed stop is programmed by pressing TIMER button. Set the rest time by pressing the button or until the rest time displayed is to your demand, then press TIMER button again.
    • Timer On: When the unit is off, press TIMER button at the first time, set the temperature with pressing the button or . Press TIMER button at the second time, set the rest time with pressing the button or . Press TIMER button at the third time, confirm the setting, then it will show on the display.
    Note: It can be set to automatically turn off or on in 0.5-24 hours. Each press of the buttons will increase or decrease the timer. The Timer can be set in 0.5 hours increment below 10 hours and 1 hour increment for 10 hours or above. The SET light will turn on while setting. To cancel the set function, press the TIMER button again.
  5. ? Fan Speed Button: Press the FAN SPEED button to select the fan speed. In COOL MODE you can choose the following settings: HI, MED, LO, or AUTO. In FAN MODE you can choose from HI, MED, and LO.
  6. Directional Louvers: Use the horizontal wheels to control horizontal airflow and the air deflectors to control vertical airflow.

[Image description: Diagram showing directional louvers with labels for air deflector and horizontal wheel.]

Operating Your Air Conditioner - Remote Control

[Image description: Diagram of the remote control with numbered buttons.]

  1. Power: Turn the air conditioner on and off.
  2. Cool: Press the COOL button to COOL mode.
  3. and : Use these buttons on the control panel and remote to increase or decrease the Set Temperature or Timer. Temperature range: 61°F ~ 88°F or 16°C ~ 31°C.
  4. Sleep: Press the SLEEP button; all of the display lights will turn off after a while, but the Sleep light is always on. In SLEEP mode, the air conditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. The set temperature will automatically raise every 30-60 minutes and at most change six times until the set temperature is 81°F or 82°F.
  5. Timer: Use these buttons on the control panel and remote to set the Timer.
    • Timer Off: The timed stop is programmed by pressing TIMER button. Set the rest time by pressing the button or until the rest time displayed is to your demand, then press TIMER button again.
    • Timer On: When the unit is off, press TIMER button at the first time, set the temperature with pressing the button or . Press TIMER button at the second time, set the rest time with pressing the button or . Press TIMER button at the third time, confirm the setting, then the rest time to next automatical switching-on could be read on the display of the machine.
    Note: It can be set to automatically turn off or on in 0.5-24 hours. Each press of the buttons will increase or decrease the timer. The Timer can be set in 0.5 hours increment below 10 hours and 1 hour increment for 10 hours or above. The SET light will turn on while setting. To cancel the set function, press the TIMER button again.
  6. Auto Mode: In AUTO mode, the unit automatically chooses the mode of operation (COOL, DRY, or FAN). In this mode, the temperature will be set automatically according to the room temperature (tested by the temperature sensor which is incorporated in the indoor unit).
  7. Fan Speed: Press the FAN SPEED button to choose the fan speed options. You can choose Hi, Med, Lo, or auto speed in COOL mode and choose Hi, Med, Lo in FAN mode.
  8. Display: To press the DISPLAY button, it can switch off/on all lights or LED display.
  9. Eco: When the unit is in ECO mode, the light will turn on. In ECO mode, the unit will turn off once the room is cooled to the user-set temperature. The unit will turn back on when the room temperature rises above the user-set temperature. Before the compressor starts, the fan motor will run for a while, then it will stop for a while, and will repeat to provide a much more comfortable feeling and save energy.
  10. Fan Only: Press the Fan Only button to FAN ONLY mode.

Battery Size: AAA - NOTE: Do not mix old and new batteries or different types of AAA batteries.

Care and Cleaning

Clean your air conditioner to keep it looking new and to minimize dust build up.

Air Filter Cleaning

The air filter should be checked at least once every month to see if it needs cleaning. Trapped particles and dust can build up in the filter and may decrease airflow, as well as cause the cooling coils to accumulate frost. To clean the air filter:

  1. Remove the filter by sliding it out from the front right side of the air conditioner. (See FIG. 15)
  2. Wash the filter using liquid dish soap and warm water. Rinse the filter thoroughly. Gently shake the filter to remove excess water.
  3. Let the filter dry completely before placing it into the air conditioner.
  4. If you do not wish to wash the filter, you may vacuum the filter to remove the dust and other particles.

FIG. 15: Illustration of air filter removal.

Cabinet Cleaning

To clean the air conditioner cabinet:

Winter Storage

To store the air conditioner when it is not in use for an extended period of time, remove it carefully from the window according to the installation instructions and cover it with plastic or place it in the original box.

Troubleshooting

PROBLEM POSSIBLE CAUSES SOLUTIONS
The Air Conditioner will not start The air conditioner is unplugged Make sure the air conditioner plug is pushed completely into the outlet.
The fuse is blown/circuit breaker is tripped Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.
Power failure The unit will automatically re-start when power is restored. There is a protective time delay (approx. 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on.
The current interrupter device is tripped Press the RESET button located on the power cord plug. If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
The Air Conditioner does not cool as it should Airflow is restricted Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner.
The temperature control may not be set correctly Lower the set thermostat temperature.
The air filter is dirty Clean the filter. See the Cleaning and Care Section of the manual.
The room may be too warm Please allow time for the room to cool down after turning on the air conditioner.
Cold air is escaping Check for open furnace registers and cold air returns.
The cooling coils are frozen See "Air Conditioner Freezing Up" below.
The Air Conditioner is freezing up Ice blocks the air flow and stops the air conditioner from cooling the room Set the MODE dial to HIGH FAN or HIGH COOL and set the thermostat to a higher temperature.
The Remote Control is not working The batteries are inserted incorrectly Check the position of the batteries.
The batteries may be dead Replace the batteries.

Troubleshooting (Cont.)

PROBLEM POSSIBLE CAUSES SOLUTIONS
Water is dripping outside Hot and humid weather This is normal.
Water is dripping inside the room The air conditioner is not correctly tilted outside For proper water drainage, make sure the air conditioner is slightly tilted downward from the front of the unit to the rear.
Water collects in the base pan Moisture removed from the air is draining into the base pan This is normal for a short period in areas with low humidity and normal for a longer period in areas with high humidity.

PDF preview unavailable. Download the PDF instead.

G27000707 Corel PDF Engine Version 9.397

Related Documents

Preview Rovsun Window Air Conditioner Use & Care Guide
Comprehensive guide for Rovsun window air conditioners (8,000-12,000 BTU), covering installation, operation, maintenance, and troubleshooting.
Preview ROVSUN Window Air Conditioner User Manual: Installation, Operation, and Troubleshooting
Comprehensive user manual for ROVSUN Window Air Conditioners (8000, 10000, 12000 BTU). Includes installation guides, operating instructions, safety precautions, and troubleshooting tips.
Preview ROVSUN YPS5-14H Portable Air Conditioner User's Manual
Comprehensive user's manual for the ROVSUN YPS5-14H Portable Air Conditioner, detailing installation, operation, maintenance, safety precautions, troubleshooting, and technical specifications.
Preview ROVSUN Wi-Fi Function User Manual for Smart Air Conditioners
Comprehensive user manual for ROVSUN smart air conditioners, detailing Wi-Fi setup, app control via SmartLife-SmartHome, device management, and troubleshooting.
Preview ROVSUN Split Type Air Conditioner: Installation, Operation, and Service Manual
Comprehensive instruction manual for the ROVSUN Split Type Air Conditioner. Covers safety precautions, parts identification, remote control operation, installation, servicing, testing, maintenance, and troubleshooting for R32 refrigerant models.
Preview ROVSUN Split Type Air Conditioner Instruction Manual
Comprehensive instruction manual for the ROVSUN Split Type Air Conditioner, covering safety precautions, parts identification, operation, installation, maintenance, and troubleshooting.
Preview ROVSUN Mini Split Air Conditioner Installation and Service Manual (R454B)
Comprehensive guide for ROVSUN multi-zone mini-split air conditioners, covering installation, servicing, safety precautions, troubleshooting, and disposal. Features R454B refrigerant and multi-zone systems.
Preview ROVSUN Split Type Air Conditioner Instruction Manual
This manual provides comprehensive instructions for the installation, operation, and maintenance of ROVSUN Split Type Air Conditioners. It includes safety precautions, parts identification, remote control functions, operational guidelines, installation procedures, test operations, maintenance tips, and troubleshooting guidance.