CONTENTS
* The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.
* The shape and position of buttons and indicators may vary according to the model, but their function are the same.
SAFETY PRECAUTIONS
SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER
- Read this guide before installing and using the appliance.
- During the installation of the indoor and outdoor units, access to the working area should be forbidden to children. Unforeseeable accidents could happen.
- Make sure that the base of the outdoor unit is firmly fixed.
- Check that air cannot enter the refrigerant system and check for refrigerant leaks when moving the air conditioner.
- Carry out a test cycle after installing the air conditioner and record the operating data.
- Protect the indoor unit with a fuse of suitable capacity for the maximum input current or with another overload protection device.
- Ensure that the mains voltage corresponds to that stamped on the rating plate. Keep the switch or power plug clean. Insert the power plug correctly and firmly into the socket, thereby avoiding the risk of electric shock or fire due to insufficient contact.
- Check that the socket is suitable for the plug, otherwise have the socket changed.
- The appliance must be fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under "over voltage category III conditions" and these means must be incorporated in the fixed wiring in accordance with the wiring rules.
- The air conditioner must be installed by professional or qualified persons.
- Do not install the appliance at a distance of less than 50 cm from inflammable substances (alcohol, etc.) Or from pressurized containers (e.g. spray cans).
- If the appliance is used in areas without the possibility of ventilation, precautions must be taken to prevent any leaks of refrigerant gas from remaining in the environment and creating a danger of fire.
- The packaging materials are recyclable and should be disposed of in the separate waste bins. Take the air conditioner at the end of its useful life to a special waste collection center for disposal.
- Only use the air conditioner as instructed in this booklet. These instructions are not intended to cover every possible condition and situation. As with any electrical household appliance, common sense and caution are therefore always recommended for installation, operation and maintenance.
- The appliance must be installed in accordance with applicable national regulations.
- Before accessing the terminals, all the power circuits must be disconnected from the power supply.
- The appliance shall be installed in accordance with national wiring regulations.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
SAFETY RULES AND PROHIBITIONS
- Do not bend, tug or compress the power cord since this could damage it. Electrical shocks or fire are probably due to a damaged power cord. Specialized technical personnel only must replace a damaged power cord.
- Do not use extensions or gang modules.
- Do not touch the appliance when barefoot or parts of the body are wet or damp.
- Do not obstruct the air inlet or outlet of the indoor or the outdoor unit. The obstruction of these openings causes a reduction in the operative efficiency of the conditioner with possible consequent failures or damages.
- In no way alter the characteristics of the appliance.
- Do not install the appliance in environments where the air could contain gas, oil or sulphur or near sources of heat.
- This appliance is not intended for use by persons (including children ) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Do not climb onto or place any heavy or hot objects on top of the appliance.
- Do not leave windows or doors open for long when the air conditioner is operating.
- Do not direct the airflow onto plants or animals.
- A long direct exposition to the flow of cold air of the conditioner could have negative effects on plants and animals.
- Do not put the conditioner in contact with water. The electrical insulation could be damaged and thus causing electrocution.
- Do not climb onto or place any objects on the outdoor unit.
- Never insert a stick or similar object into the appliance. It could cause injury.
- Children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
NAME OF PARTS
Indoor Unit
Diagram showing the indoor unit with labels pointing to: Mounting plate, Front panel, Emergency button, Air filter, Air outlet, Air deflector and flap, Refrigerant connecting pipe.
Outdoor Unit
Diagram showing the outdoor unit with labels pointing to: Air outlet, Air inlet, Wiring cover, Drainage pipe, Connection wiring, Valve protective cover, Gas valve (Low pressure valve), Liquid valve (High pressure valve).
Indoor Display
Diagram of the indoor unit display panel showing numbered indicators: 1 (88 symbol), 2 (clock symbol), 3 (moon symbol), 4 (power symbol), 5 (power symbol).
No. | LED | Function |
---|---|---|
1 | 88 | Indicator for Timer, temperature and Error codes. |
2 | ⏰ | Lights up during Timer operation. |
3 | 🌙 | SLEEP mode |
4 | The symbol appears when the unit is turned on, and disappear when the unit is turned off. | |
5 | ⚡ | The symbol appears when power on. |
Note: The shape and position of switches and indicators may be different according to the model, but their function is the same.
REMOTE CONTROL
Remote control DISPLAY
No. | Symbols | Meaning |
---|---|---|
1 | 🔋 | Battery indicator |
2 | ☁️ | Auto Mode |
3 | 🌡️ | Cooling Mode |
4 | 🌊 | Dry Mode |
5 | ☁️ | Fan only Mode |
6 | 🔥 | Heating Mode |
7 | 💰 | ECO Mode |
8 | ⏲ | Timer |
9 | 8.8°E | Temperature indicator |
10 | ☁️ | Fan speed: Auto/ low/ low-mid/ mid/ mid-high/ high |
11 | 🔇 | Mute function |
12 | ✈ | TURBO function |
13 | ↕ | Up-down auto swing |
14 | ↔ | Left-right auto swing |
15 | 🌙 | SLEEP function |
16 | 💖 | Health function |
17 | 💧 | I FEEL function |
18 | 📡 | Signal indicator |
19 | 🌼 | Gentle wind |
20 | 🔒 | Child-Lock |
21 | 📱 | Display ON/OFF |
22 | 🦢 | Anti-Mildew |
Note: The display and some functions of the remote control may vary according to the model.
Remote control Buttons
No. | Button | Function |
---|---|---|
1 | ⚡ | To turn on/off the air conditioner. |
2 | ▲ | To increase temperature, or Timer setting hours. |
3 | ▼ | To decrease temperature, or Timer setting hours. |
4 | MODE | To select the mode of operation (AUTO, COOL, DRY, FAN, HEAT). |
5 | ECO | To activate/deactivate the ECO function. |
Long press to activate/deactivate the 8°C heating function (depending on models). | ||
6 | TURBO | To activate/deactivate the TURBO function. |
7 | FAN | To select the fan speed of auto/low/mid/high. |
8 | TIMER | To set the time for timer on/off. |
9 | SLEEP | To switch-on/off the function SLEEP. |
10 | DISPLAY | To switch-on/off the LED display. |
11 | SWING ↕ | To stop or start horizontal flaps louver movement or set the desired up/down air flow direction. |
12 | SWING ↔ | To stop or start vertical deflectors louver movement or set the desired left/right air flow direction. |
13 | I FEEL | To switch-on/off the I FEEL function. |
14 | MUTE | To switch-on/off the MUTE function. Long press to activate/deactivate the GEN function (depending on models). |
15 | ANTI-MILDEW | To switch-on/off the ANTI-MILDEW function. |
16 | MODE + TIMER | To activate/deactivate the CHILD-LOCK function. |
17 | SWING ↕ + SWING ↔ | To activate/deactivate the SELF-CLEAN function (depending on models). |
18 | FAN + MUTE | To activate/deactivate the GENTLE WIND function (depending on models). |
19 | SLEEP + DISPLAY | To activate/deactivate the HEALTH function (depending on models). |
Note: The display and some functions of the remote control may vary according to the model. The shape and position of buttons and indicators may vary according to the model, but their function is the same. The unit confirms the correct reception of each button with the beep.
Replacement of Batteries
Remove the battery cover plate from the rear of the remote control, by sliding it in direction as the arrow. Install the batteries according the direction (+ and -) shown on the Remote Control. Reinstall the battery cover by sliding it into place.
Use 2 pieces LRO3 AAA (1.5V) batteries. Do not use rechargeable batteries. Replace the old batteries with new ones of the same type when the display is no longer legible. Do not dispose batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
Temperature Display Unit (°C / °F)
For some models of the remote controller, you can program the temperature display between °C and °F.
- Press and hold the TURBO button over 5 seconds to get into the change mode;
- Press and hold the TURBO button, until it switches to °C and °F;
- Then release the pressing and wait for 5 seconds, the function will be selected.
Remote Control Usage Guidelines
- Direct the remote control toward the Air conditioner.
- Check that there are no objects between the remote control and the Signal receptor in the indoor unit.
- Never leave the remote control exposed to the rays of the sun.
- Keep the remote control at a distance of at least 1m from the television or other electrical appliances.
Operation Modes
COOLING MODE
The cooling function allows the air conditioner to cool the room and reduce Air humidity at the same time.
To activate the cooling function (COOL), press the MODE button until the 🌡️ symbol appears on the display. With the button ▼ or ▲ set a temperature lower than that of the room.
FAN MODE (Not FAN button)
Fan mode, air ventilation only.
To set the FAN mode, press MODE until ☁️ appears on the display.
HEATING MODE
The heating function allows the air conditioner to heat the room.
To activate the heating function (HEAT), press the MODE button until the 🔥 symbol appears on the display. With the button ▼ or ▲ set a temperature higher than that of the room.
In HEATING operation, the appliance can automatically activate a defrost cycle, which is essential to clean the frost on the condenser so as to recover its heat exchange function. This procedure usually lasts for 2-10 minutes. During defrosting, indoor unit fan stop operation. After defrosting, it resumes to HEATING mode automatically.
(For North American market) If necessary, you can press ECO button 10 times within 8 seconds under heating mode to start the forced defrosting. It will defrost the outdoor ice much faster.
DRY MODE
This function reduces the humidity of the air to make the room more comfortable.
To set the DRY mode, Press MODE until 🌊 appears in the display. An automatic function of pre-setting is activated.
FAN SPEED function (FAN button)
Change the operating fan speed.
Press FAN button to set the running fan speed, it can be set to AUTO/ MUTE/ LOW/ LOW-MID / MID/ MID-HIGH/ HIGH/ TURBO speed circularly.
AUTO MODE
Automatic mode.
To set the AUTO mode, press MODE until ☁️ appears on the display. In AUTO mode the run mode will be set automatically according to the room temperature.
Special Functions
Child-Lock function
- Long press MODE and TIMER buttons together to activate this function, and do it again to deactivate this function.
- Under this function, no single button will active.
TIMER function ---- TIMER ON
To automatically switch on the appliance.
When the unit is switch-off, you can set the TIMER ON.
To set the time of automatic switch-on as below:
- Press TIMER button first time to set the switch-on, and ⏲ will appear on the remote display and flashes.
- Press ▲ or ▼ button to set desired Timer-on time. Each time you press the button, the time increases/decreases by half an hour between 0 and 10 hours and by one between 10 and 24 hours.
- Press TIMER button second time to confirm.
- After Timer-on setting, set the needed mode (Cool/ Heat/ Auto/ Fan/ Dry), by press the MODE button. And set the needed fan speed, by press FAN button. And press ▲ or ▼ to set the needed operation temperature.
CANCEL it by press TIMER button.
TIMER function ---- TIMER OFF
To automatically switch off the appliance.
When the unit is switch-on, you can set the TIMER OFF.
To set the time of automatic switch-off, as below:
- Confirm the appliance is ON.
- Press the TIMER button at first time to set the switch-off. Press ▲ or ▼ to set the needed timer.
- Press TIMER button at the second time to confirm.
CANCEL it by press TIMER button.
Note: All programming should be operated within 5 seconds, otherwise the setting will be cancelled.
SWING function
- Press the button SWING ↕ to activate the louver.
- Press SWING ↕ to activate the horizontal flaps to swing from up to down, the ↕ will appear on the remote display. Press again to stop the swing movement at the current angle.
- Press SWING ↔ to active the vertical deflectors to swing from left to right, the ↔ will appear on the remote display. Press again to stop the swing movement at the current angle.
- If the vertical deflectors are positioned manually which placed under the flaps, they allow to move the air flow direct to rightward or leftward.
- For some inverter heating models, press horizontal SWING and vertical SWING together button at the same time, it will activate the Self-Clean function.
Caution: This adjustment must be done while the appliance is switched off. Never position "Flaps" manually, the delicate mechanism might get seriously damaged! Never put fingers, sticks or other objects into the air inlet or outlet vents. Such accidental contact with live parts might cause unforeseeable damage or injury.
TURBO function
To activate turbo function, press the TURBO button, and ✈ will appear on the display. Press again to cancel this function.
In COOL/HEAT mode, when you select TURBO feature, the appliance will turn to quick COOL or quick HEAT mode, and operate the highest fan speed to blow strong airflow.
MUTE function
1. Press MUTE button to active this function, and 🔇 will appears on the remote display. Do it again to deactivate this function.
2. When the MUTE function runs, the remote controller will display the auto fan speed, and the indoor unit will operate at lowest fan speed to help experience a quiet feeling.
3. When press FAN/ TURBO button, the MUTE function will be cancel. MUTE function can not be activated under dry mode.
ECO function
In this mode the appliance automatically sets the operation to save energy.
Press the ECO button, the 💰 appears on the display, and the appliance will run in ECO mode. Press again to cancel it.
Note: The ECO function is available in both COOLING and HEATING modes.
SLEEP function
Pre-setting automatic operating program.
Press SLEEP button to activate the SLEEP function, and 🌙 appears on the display. Press again to cancel this function.
After 10 hours running in sleep mode, the air conditioner will change to the previously set mode.
DISPLAY function (Indoor display)
Switch ON/OFF the LED display on panel.
Press DISPLAY button to switch off the LED display on the panel. Press again to switch on the LED display.
I FEEL function (Optional)
Press I FEEL button to active the function, the 💧 will appear on the remote display. Do it again to deactivate this function.
This function enables the remote control to measure the temperature at its current location, and send this signal to the air conditioner to optimize the temperature around you and ensure the comfort. It will automatically deactivate 8 hours later. (2 hours for some models).
ANTI-MILDEW function (Optional)
Press ANTI-MILDEW button to activate the ANTI-MILDEW function, 🦢 will appear on the display. Do it again to deactivate this function. After running COOL/ DRY for more than 30 minutes, you can operate this function, the unit will blow airflow for about 15 minutes to dry the inner parts to avoid mildew, then shuts off the unit.
Note: ANTI-MILDEW function only available in DRY/COOLING mode.
SELF-CLEAN function (Optional)
Only optional for some heating pump inverter appliance. To active this function, turn off the indoor unit at first, then press SWING ↕ and SWING ↔ button at the same time toward the indoor unit, until hear a beep, and AC will appear on the remote controller display and the indoor LED display.
- This function helps carry away the accumulated dirt, bacteria, etc from the indoor evaporator.
- This function will run about 30 minutes, and it will return to the pre-setting mode. You can press ⚡ button to cancel this function during the process. You will hear 2 beeps when it's finished or cancelled.
Note: It's normal if there is some noise during this function process, as plastic materials expand with heat and contract with cold.
We suggest operating this function at the following ambient conditions to avoid certain safety protection features:
- Indoor unit Temp < 86°F (30°C)
- Outdoor unit 41°F (5°C) < Temp < 86°F(30°C)°
Note: It's suggested to utilize this function every 3 months.
Gentle Wind function (Optional)
- Turn on the indoor unit, and change to COOL mode, then long press FAN and MUTE button together 3 seconds to active this function, 🌼 will appear on the display. Do it again to deactivate it.
- This function will auto close the vertical flaps, and give you the comfortable gentle wind feeling.
Health function (Optional)
- Turn on the indoor unit at first, and long press SLEEP and DISPLAY button together 3 seconds to active this function, 💖 will appear on the display. Do it again to deactivate it.
- When the HEALTH function is initiated, the Ionizer/ Plasma/ Bipolar Ionizer/ UVC Lights (depending on models) will be energized and running.
8°C heating function (Optional)
- Long press ECO button over 3 seconds to active this function, and 8°C (46°F) will appear on the remote display. Do it again to deactivate this function.
- This function will auto start the heating mode when the room temperature is lower than 8°C (46°F), and it will return to standby if the temperature reaches 9°C (48°F).
- If the room temperature is higher than 18°C (64°F), the appliance will cancel this function automatically.
GEN function (Optional)
- Turn on the indoor unit at first, and long press MUTE button 3 seconds to activate, and do it again to deactivate this function.
- Under this function, short press MUTE button to select the General type L3 - L2 - L1 - OF.
- Select OF and wait 2 seconds to exit it.
- * If the indoor unit displays "OA", please use the remote to raise the operating gear of the GEN mode, and the compressor will restart after stopping for 3 minutes.
Note: These instructions are for reference only. Due to different models, the actual display and functions may differ from the instructions. Please refer to the actual product.
OPERATION INSTRUCTIONS
Attempt to use the air conditioner under the temperature beyond the specified range may cause the air conditioner protection device to start and the air conditioner may fail to operate. Therefore, try to use the air conditioner in the following temperature conditions.
Fixed air conditioner:
MODE | Heating | Cooling | Dry |
---|---|---|---|
Room temperature | 0°C~27°C(32°F~80°F) | 17°C~32°C(63°F~90°F) | T1 climate: 15°C~43°C(59°F~109°F) T3 climate: 15°C~52°C(59°F~125°F) |
Outdoor temperature | -7°C~24°C(19°F~75°F) |
Inverter air conditioner:
MODE | Heating | Cooling | Dry |
---|---|---|---|
Room temperature | 0°C~27°C (32°F~80°F) | 17°C~32°C(63°F~90°F) | T1 climate: 15°C~50°C(59°F~122°F) (Low temperature cooling: -15°C~50°C(5°F~122°F)) T3 climate: 15°C~55°C(59°F~131°F) |
Outdoor temperature | -15°C~24°C(5°F~75°F) (Low temperature heating: -20°C~24°C (-4°F~75°F)) |
With the power supply connected, restart the air conditioner after shutdown, or switch it to other mode during operation, and the air conditioner protection device will start. The compressor will resume operation after 3 minutes.
Characteristics of heating operation (applicable to Heat pump models)
Preheating:
When the heating function is enabled, the indoor unit will take 2~5 minutes for preheating, after that the air conditioner will start heating and blows warm air.
Defrosting:
During heating, when the outdoor unit frosted, the air conditioner will enable the automatic defrosting function to improve the heating effect. During defrosting, the indoor and outdoor fans stop running. The air conditioner will resume heating automatically after defrosting finish.
Emergency button:
Open the panel and find the emergency button on the electronic control box when the remote controller fails. (Always press the emergency button with insulation material.)
Current status | Operation | Respond | Enter mode |
---|---|---|---|
Standby | Press the emergency button once | It beeps briefly once. | Cooling mode |
Standby (Only for Heat pump models) | Press the emergency button twice in 3 seconds | It beeps briefly twice. | Heating mode |
Running | Press the emergency button once | It keeps beeping for a while | Off mode |
Diagram showing the indoor unit's control box cover with an emergency button. Text describes its operation for different current statuses (Standby, Running) to enter Cooling mode, Heating mode, or Off mode.
INSTRUCTIONS FOR SERVICING(R32)
1. Check the information in this manual to find out the dimensions of space needed for proper installation of the device, including the minimum distances allowed compared to adjacent structures.
2. Appliance shall be installed, operated and stored in a room with a floor area larger than 4m².
3. The installation of pipe-work shall be kept to a minimum.
4. The pipe-work shall be protected from physical damage, and shall not be installed in an unventilated space if the space is smaller than 4m².
5. The compliance with national gas regulations shall be observed.
6. The mechanical connections shall be accessible for maintenance purposes.
7. Follow the instructions given in this manual for handling, installing, cleaning, maintaining and disposing of the refrigerant.
8. Make sure ventilation openings are clear of any obstruction.
9. Notice: The servicing shall be performed only as recommended by the manufacturer.
10. Warning: The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
11. Warning: The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance) and ignition sources (for example an operating electric heater).
12. The appliance shall be stored so as to prevent mechanical damage from occurring.
13. It is appropriate that anyone who is called upon to work on a refrigerant circuit should hold a valid and up-to-date certificate from an assessment authority accredited by the industry and recognizing their competence to handle refrigerants, in accordance with the assessment specification recognized in the industrial sector concerned. Service operations should only be carried out in accordance with the recommendations of the equipment manufacturer. Maintenance and repair operations that require the assistance of other qualified persons must be conducted under the supervision of the person competent for the use of flammable refrigerants.
14. Every working procedure that affects safety means shall only be carried out by competent persons.
15. Warning:
- Do not use any means to accelerate the defrosting process or clean the frost on your own. Follow the recommended guidelines from the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Do not pierce or burn.
- Be aware that refrigerants may not contain an odor.
Diagrams showing the A2L symbol with "Caution: Risk of fire". Associated text indicates "Read operator's manual", "Operating instructions", and "Read technical manual".
Information on servicing:
- Checks to the area: Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
- Work procedure: Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed.
- General work area: All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
- Checking for presence of refrigerant: The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
- Presence of fire extinguisher: If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO₂ fire extinguisher adjacent to the charging area.
- No ignition sources: No person carrying out work in relation to a refrigeration system which involves exposing any pipe work shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. "No Smoking" signs shall be displayed.
- Ventilated area: Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any work that will produce heat. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
- Checks to the refrigeration equipment: Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer's maintenance and service guidelines shall be followed. If in doubt consult the manufacturer's technical department for assistance.
Checks for installations using flammable refrigerants:
- The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
- The ventilation machinery and outlets are operating adequately and are not obstructed;
- If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
- Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
- Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include:
- That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
- That no live electrical components and wiring are exposed while charging, recovering or purging the system;
- That there is continuity of earth bonding.
17. Repairs to sealed components
Sealed electrical components shall be replaced.
18. Repair to intrinsically safe components
Intrinsically safe components must be replaced.
19. Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
20. Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.
21. Leak detection methods
The following leak detection methods are deemed acceptable for systems containing flammable refrigerants.
Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area). Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25% maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/ extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.
22. Removal and evacuation
When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, it is important that best practice is followed since inflammability is a consideration. The following procedure shall be adhered to:
- Remove refrigerant;
- Purge the circuit with inert gas;
- Evacuate;
- Purge again with inert gas;
- Open the circuit by cutting or brazing.
The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task.
Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to take place.
Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
23. Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
a) Become familiar with the equipment and its operation.
b) Isolate system electrically.
c) Before attempting the procedure, ensure that:
- mechanical handling equipment is available, if required, for handling refrigerant cylinders;
- all personal protective equipment is available and being used correctly;
- the recovery process is supervised at all times by a competent person;
- recovery equipment and cylinders conform to the appropriate standards.
d) Pump down refrigerant system, if possible.
e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
f) Make sure that the cylinder is situated on the scales before recovery takes place.
g) Start the recovery machine and operate in accordance with manufacturer's instructions.
h) Do not overfill cylinders. (No more than 80 % volume liquid charge).
i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
j) When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
k) Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
24. Labeling
Equipment shall be labeled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.
25. Recovery
When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designated for the recovered refrigerant and labeled for that refrigerant (i.e. Special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure-relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of all appropriate refrigerants including, when applicable, flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recover cylinder, and the relevant waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.
26. Warning
- Minimum installation height, minimum room area (operating or storage) refer to installation manual.
- Risk Of Fire-Auxiliary devices which may be ignition sources shall not be installed in the ductwork, other than auxiliary devices listed for use with the specific appliance. See instructions.
- Mount with the lowest moving parts at least 2.5m (8ft) above floor or grade level.
- Risk of electric shock. Can cause injury or death. Disconnect all remote electric power supplies before servicing.
- Risk Of Fire. Flammable Refrigerant Used. To Be Repaired Only By Trained Service Personnel. Do Not Puncture Refrigerant Tubing.
- Risk Of Fire. Dispose Of Properly In Accordance With Federal Or Local Regulations. Flammable Refrigerant Used.
- Risk Of Fire. Flammable Refrigerant Used. Consult Repair Manual/Owner's Guide Before Attempting To Service This Product. All Safety Precautions Must Be Followed.
- Risk Of Fire. Due to Flammable Refrigerant Used. Follow Handling Instructions Carefully in Compliance with National Regulations.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer;
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater.
- Do not pierce or burn.
- Be aware that refrigerants may not contain an odour.
27. Statement
- Please use the flammable gas detector to check before unload and open the container.
- No fire source and smoking.
- That pipe-work shall be protected from physical damage and, in the case of FLAMMABLE REFRIGERANTS, shall not be installed in an unventilated space, if that space is smaller than Amin in Annex GG, except for A2L REFRIGERANTS where the installed pipes comply with 22.116. In case of field charge, the effect on REFRIGERANT CHARGE caused by the different pipe length has to be quantified;
- That compliance with national gas regulations shall be observed;
- that mechanical connections made in accordance with 22.118 shall be accessible for maintenance purposes;
- That pipe-work including piping material, pipe routing, and installation shall include protection from physical damage in operation and service, and be in compliance with national and local codes and standards, such as ASHRAE 15, ASHRAE 15.2, IAPMO Uniform Mechanical Code, ICC International Mechanical Code, or CSA B52. All field joints shall be accessible for inspection prior to being covered or enclosed;
- That after completion of field piping for split systems, the field pipework shall be pressure tested with an inert gas and then vacuum tested prior to refrigerant charging, according to the following requirements;
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- Working personnel for maintenance, service and repair operations. Every working procedure that affects safety means shall only be carried out by competent persons according to Annex HH. Examples for such working procedures are: breaking into the refrigerating circuit; opening of sealed components; opening of ventilated enclosures.
Important Considerations
- The air conditioner must be installed by professional personnel and the Installation manual is used only for the professional installation personnel! The installation specifications should be subject to our after-sale service regulations.
- When filling the combustible refrigerant, any of your rude operations may cause serious injury or injuries to human body and objects.
- A leak test must be done after the installation completed.
- It is a must to do the safety inspection before maintaining or repairing an air conditioner using combustible refrigerant in order to ensure that the fire risk is reduced to minimum.
- It is necessary to operate the machine under a controlled procedure in order to ensure that any risk arising from the combustible gas or vapor during the operation is reduced to minimum.
- Requirements for the total weight of filled refrigerant and the area of a room to be equipped with an air conditioner (are shown as in the following Tables GG.1 and GG.2)
The maximum charge and the required minimum floor area
m₁ = (6 m³) x LFL, m₂ = (52 m³)) x LFL, m₃ = (260 m³ )x LFL
Where LFL is the lower flammable limit in kg/ m³, R32 LFL is 0.306 Kg/ m³.
For the appliances with a charge amount m₁ < M = m₂:
The maximum charge in a room shall be in accordance with the following:
Mmax = 2.5 x (LFL)5/4 x h₀ x A1/2 not to exceed Mmax = SF x LFL x h₀ x A (GG.3DV)
The required minimum floor area Amin to install an appliance with refrigerant charge M (kg) Shall be in accordance with following: AMin = (M/ (2.5 x (LFL)5/4 x h₀))² not less than Amin = M/ (SF x LFL x h₀) (GG.4DV)
Where:
Category | LFL (kg/m³) | h₀(m) | Floor area (m²) | ||||||
---|---|---|---|---|---|---|---|---|---|
4 | 7 | 10 | 15 | 20 | 30 | 50 | |||
R32 | 0.306 | 1 | 0.61 | 1.07 | 1.53 | 2.20 | 2.54 | 3.12 | 4.02 |
1.8 | 1.10 | 1.93 | 2.75 | 3.97 | 4.58 | 5.61 | 7.24 | ||
2.2 | 1.35 | 2.36 | 3.37 | 4.85 | 5.60 | 6.86 | 8.85 |
Category | LFL (kg/m³) | h₀(m) | Charge amount (M) (kg) Minimum room area (m²) | ||||||
---|---|---|---|---|---|---|---|---|---|
1.836kg | 2.448kg | 3.672kg | 4.896kg | 6.12kg | 7.956kg | 10.34kg | |||
R32 | 0.306 | 1 | 18.51 | 41.65 | 74.05 | 115.70 | 195.53 | 330.26 | |
1.8 | 8.89 | 13.33 | 22.85 | 35.71 | 60.35 | 101.93 | |||
2.2 | 7.27 | 10.91 | 15.30 | 23.90 | 40.40 | 68.24 |
Installation Safety Principles
1. Site Safety
Diagram showing "Open Flames Prohibited" with a red circle and slash over a flame icon. Next to it, "Ventilation Necessary" with an icon representing airflow. Below, "Must wear protective clothing and anti-static gloves" with icons for gloves and clothing. Finally, "Don't use mobile phone" with a crossed-out mobile phone icon.
2. Operation Safety
INDOOR UNIT INSTALLATION
Step1: Select Installation location
1.1 Ensure the installation complies with the installation minimum dimensions (defined below) and meets the minimum and maximum connecting piping length and maximum change in elevation as defined in the System Requirements section.
1.2 Air inlet and outlet will be clear of obstructions, ensuring proper airflow throughout the room.
1.3 Condensate can be easily and safely drained.
1.4 All connections can be easily made to outdoor unit.
1.5 Indoor unit is out of reach of children.
1.6 A mounting wall strong enough to withstand four times the full weight and vibration of the unit.
1.7 Filter can be easily accessed for cleaning.
1.8 Leave enough free space to allow access for routine maintenance.
1.9 Install at least 10 ft. (3 m) away from the antenna of TV set or radio. Operation of the air conditioner may interfere with radio or TV reception in areas where reception is weak. An amplifier may be required for the affected device.
1.10 Do not install in a laundry room or by a swimming pool due to the corrosive environment.
1.11 For ETL certification area, Caution: Mount with the lowest moving parts at least 8 ft. (2.4 m) above Floor or grade level.
Minimum Indoor Clearances
Diagram showing minimum clearance requirements around the indoor unit: ≥13cm/5in from sides, ≥20cm/8in from ceiling, ≥250cm/8ft from floor.
Step2: Install Mounting Plate
2.1 Take the mounting plate from the back of indoor unit.
2.2 Ensure to meet the minimum installation dimension requirements as step 1, according to the size of mounting plate, determine the position and stick the mounting plate close to the wall.
2.3 Adjust the mounting plate to a horizontal state with a spirit level, then mark out the screw hole positions on the wall.
2.4 Put down the mounting plate and drill holes in the marked positions with drill.
2.5 Insert expansion rubber plugs into the holes, then hang the mounting plate and fix it with screws.
Diagram showing the mounting plate with screw hole positions and dimensions (Φ 2.8" (70mm)).
Note: (I) Make sure the mounting plate is firm enough and flat against the wall after installation. (II) This figure shown may be different from the actual object, please take the latter as the standard.
Step3: Drill Wall Hole
A hole in the wall should be drilled for refrigerant piping, the drainage pipe, and connecting cables.
3.1 Determine the location of wall hole base on the position of mounting plate.
3.2 The hole should be have a 70mm diameter at least and a small oblique angle to facilitate drainage.
3.3 Drill the wall hole with 70mm core drill and with small oblique angle lower than the indoor end about 5mm to 10mm.
3.4 Place the wall sleeve and wall sleeve cover (both are optional parts) to protect the connection parts.
Caution: When drill the wall hole, make sure to avoid wires, plumbing and other sensitive components.
Diagram showing the wall hole drilling process, indicating a 70mm diameter and a small oblique angle. Shows optional wall sleeve and cover.
Step4: Connecting Refrigerant Pipe
4.1 According to the wall hole position, select the appropriate piping mode. There are three optional piping modes for indoor units as shown in the figure below: In Piping Mode 1 or Piping Mode 3, a notch should be made by using scissors to cut the plastic sheet of piping outlet and cable outlet on the corresponding side of the indoor unit.
Note: When cutting off the plastic sheet at the outlet, the cut should be trimmed to smooth.
Diagrams illustrating three optional piping modes for indoor units. Shows how to make a notch in the plastic sheet for piping and cable outlets. Shows bending connecting pipes (YES/NO).
4.2 Bending the connecting pipes with the port facing up as shown in the figure.
4.3 Take off the plastic cover in the pipe ports and take off the protective cover on the end of piping connectors.
4.4 Check whether there is any sundry on the port of the connecting pipe and make sure the port is clean.
4.5 After aligning the center, rotate the nut of the connecting pipe to tighten the nut as tightly as possible by hand.
4.6 Use a torque wrench to tighten it according to the torque values in the torque requirements table; (Refer to the torque requirements table on section INSTALLATION PRECAUTIONS)
4.7 Wrap the joint with the insulation pipe.
Note: When flared joints are reused indoors, the flare part shall be re-fabricated.
Step5: Connect Drainage Hose
5.1 Adjust the drainage hose (if applicable). In some models, both sides of the indoor unit are provided with drainage ports, you can choose one of them to attach the drainage hose. And plug the unused drain port with the rubber attached in one of the ports.
5.2 Connect the drainage hose to the drainage port, ensure the joint is firm and the sealing effect is good.
5.3 Wrap the joint firmly with teflon tape to ensure no leaks.
Note: Make sure there is no twists or dents, and the pipes should be placed obliquely downward to avoid blockage, to ensure proper drainage.
Step6: Connect Wiring
6.1 Choose the right cables size determined by the maximum operating current on the nameplate. (Check the cables size refer to section INSTALLATION PRECAUTIONS)
6.2 Open the front panel of indoor unit.
6.3 Use a screwdriver, open the electric control box cover, to reveal the terminal block.
6.4 Unscrew the cable clamp.
6.5 Insert one end of the cable into the position of control box from the back of the right end of the indoor unit.
6.6 Connect the wires to corresponding terminal according to the wiring diagram on the electric control box cover. And make sure that they are well connected.
6.7 Screw the cable clamp to fasten the cables.
6.8 Reinstall the electric control box cover and front panel.
Step7: Wrap Piping and Cable
After the refrigerant pipes, drainage hose are installed, in order to save space, protect and insulate them, it must be bundled with insulating tape before passing them through the wall hole.
7.1 Arrange the pipes, cables and drainage hose well as the following picture.
Diagram showing refrigerant piping, insulation tape, and drainage hose bundled together. Note: (I) Make sure the drainage hose is at the bottom. (II) Avoid crossing and bending of parts.
7.2 Using the insulating tape wrap the refrigerant pipes, connecting wires and drainage hose together tightly.
Step8: Mount Indoor Unit
8.1 Slowly pass the refrigerant pipes, connecting wires and drainage hose wrapped bundle through the wall hole.
8.2 Hook the top of indoor unit on the mounting plate.
8.3 Apply slight pressure to the left and right sides of the indoor unit, make sure the indoor unit is hooked firmly.
8.4 Push down the bottom of indoor unit to let the snaps onto the hooks of the mounting plate, and make sure it is hooked firmly.
Sometimes, if the refrigerant pipes were already embedded in the wall, or if you want to connect the pipes and wires on the wall, do as below:
- Hook the top of the indoor unit on the mounting plate without piping and wiring.
- Lift the indoor unit opposite the wall, unfold the bracket on the mounting plate, and use this bracket to prop up the indoor unit, there will be a big space for operation.
- Do the refrigerant piping, wiring, connect drainage hose, and wrap them as Step 4 to 7.
OUTDOOR UNIT INSTALLATION
Step1: Select Installation Location
Select a site that allows for the following:
- Do not install the outdoor unit near sources of heat, steam or flammable gas.
- Do not install the unit in too windy or dusty places.
- Do not install the unit where people often pass. Select a place where the air discharge and operating sound will not disturb the neighbors.
- Avoid installing the unit where it will be exposed to direct sunlight (otherwise use a protection, if necessary, that should not interfere with the air flow).
- Reserve the spaces as shown in the picture for the air to circulate freely.
- Install the outdoor unit in a safe and solid place.
- If the outdoor unit is subject to vibration, place rubber blankets onto the feet of the unit.
Diagram showing recommended clearances around the outdoor unit: Over 30cm/12in from sides, Over 50cm/20in from front/back, Over 200cm/79in from discharge.
Step2: Install Drainage Hose
2.1 This step only for heat pump models or RCACs.
2.2 Insert the drainage joint to the hole at the bottom of the outdoor unit.
2.3 Connect the drainage hose to the joint and make the connection well enough.
Diagram showing the drainage joint and hose connection at the bottom of the outdoor unit.
Step3: Fix Outdoor Unit
- According to the outdoor unit installation dimensions to mark the installation position for expansion bolts.
- Drill holes and clean the concrete dust and place the bolts.
- If applicable, install 4 rubber blankets on the hole before placing the outdoor unit (Optional). This will reduce vibrations and noise.
- Place the outdoor unit base on the bolts and pre-drilled holes.
- Use wrench to fix the outdoor unit firmly with bolts.
Note: The outdoor unit can be fixed on a wall-mounting bracket. Follow the instruction of the wall-mounting bracket to fix the wall-mounting bracket on the wall, and then fasten the outdoor unit on it and keep it horizontal. The wall-mounting bracket must be able to support at least 4 times of the weight of outdoor unit.
Illustration showing the outdoor unit being fixed with bolts, and an optional diagram showing 4 rubber blankets for vibration reduction.
Step4: Install Wiring
4.1 Use a phillips screwdriver to unscrew wiring cover, grasp and press it down gently to take it down.
4.2 Unscrew the cable clamp and take it down.
4.3 According to the wiring diagram pasted inside the wiring cover, connect the connecting wires to the corresponding terminals, and ensure all connections are firmly and securely.
4.4 Reinstall the cable clamp and wiring cover.
Note: When connecting the wires of indoor and outdoor units, the power should be cut off.
Diagram showing the outdoor unit's terminal block, cable clamp, wiring cover, and wiring diagram.
Step5: Connecting Refrigerant Pipe
5.1 Unscrew the valve cover, grasp and press it down gently to take it down (if the valve cover is applicable).
5.2 Remove the protective caps from the end of valves.
5.3 Take off the plastic cover in the pipe ports and check whether there is any sundry on the port of the connecting pipe and make sure the port is clean.
5.4 After aligning the center, rotate the flare nut of the connecting pipe to tighten the nut as tightly as possible by hand.
5.5 Use a spanner to hold the body of the valve and use a torque wrench to tighten the flare nut according to the torque values in the torque requirements table. (Refer to the torque requirements table on section INSTALLATION PRECAUTIONS)
Diagrams showing the outdoor unit's valve cover, connection pipes, and flare nuts. Shows taking down the valve cover and connecting pipes.
Step6: Vacuum Pumping
- Use a spanner to take down the protective caps from the service port, low pressure valve and high pressure valve of the outdoor unit.
- Connect the pressure hose of manifold gauge to the service port on the outdoor unit low pressure valve.
- Connect the charge hose from the manifold gauge to the vacuum pump.
- Open the low pressure valve of the manifold gauge and close the high pressure valve.
- Turn on the vacuum pump to vacuum the system.
- The vacuum time should not be less than 15 minutes, or make sure the compound gauge indicates -0.1 MPa (-76 cmHg).
- Close the low pressure valve of the manifold gauge and turn off the vacuum.
- Hold the pressure for 5 minutes, make sure that the rebound of compound gauge pointer does not exceed 0.005 MPa.
- Open the low pressure valve counterclockwise for 1/4 turn with hexagonal wrench to let a little refrigerant fill in the system, and close the low pressure valve after 5 seconds and quickly remove the pressure hose.
- Check all indoor and outdoor joints for leakage with soapy water or leak detector.
- Fully open the low pressure valve and high pressure valve of the outdoor unit with hexagonal wrench.
- Reinstall the protective caps of the service port, low pressure valve and high pressure valve of the outdoor unit.
- Reinstall the valve cover.
Diagram showing the manifold gauge connected to the outdoor unit's service port, low pressure valve, and high pressure valve, and connected to a vacuum pump via a charge hose. Labels include compound gauge, pressure gauge, etc.
TEST OPERATION
Inspections Before Test Run
Do the following checks before test run.
Description | Inspection method |
---|---|
Electrical safety inspection |
|
Installation safety inspection |
|
Refrigerant leakage detection | The piping joint, the connector of the two valves of the outdoor unit, the valve spool, the welding port, etc., where leakage may occur. Foam detection method: Apply soapy water or foam evenly on the parts where leakage may occur, and observe whether bubbles appear or not, if not, it indicates that the leakage detection result is safe. Leak detector method: Use a professional leak detector and read the instruction of operation, detect at the position where leakage may occur. The duration of leak detection for each position should last for 3 minutes or more; If the test result shows that there is leakage, the nut should be tightened and tested again until there is no leakage; After the leak detection is completed, wrap the exposed pipe connector of indoor unit with thermal insulation material and wrap with insulation tape. |
Test Run Instruction
- Turn on the power supply.
- Press the ON/OFF button on the remote controller to turn on the air conditioner.
- Press the Mode button to switch the mode COOLING and HEATING. In each mode set as below: COOLING - Set the lowest temperature; HEATING - Set the highest temperature.
- Run about 8 minutes in each mode and check all functions are properly run and respond the remote controller. Functions check as recommended: 4.1 If the outlet air temperature responds to the cooling and heating modes. 4.2 If the water drains properly from the drainage hose. 4.3 If the Louver and deflectors (optional) rotate properly.
- Observe the test run state of the air conditioner at least 30 minutes.
- After the successfully test run, return the normal setting and press ON/OFF button on the remote controller to turn off the unit.
- Inform the user to read this manual carefully before use, and demonstrate to the user how to use the air conditioner, the necessary knowledge for service and maintenance, and the reminder for storage of accessories.
Note: If the ambient temperature exceeds the range mentioned in the section OPERATION INSTRUCTIONS, and it can not run COOLING or HEATING mode, lift the front panel and refer to the emergency button operation to run the COOLING and HEATING mode.
MAINTENANCE
Warning
When cleaning, you must shut down the machine and cut off the power supply for more than 5 minutes. Under no circumstances should the air conditioner be flushed with water. Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner, so only use a soft dry cloth or wet cloth dipped with neutral detergent to clean the air conditioner. Pay attention to cleaning the filter screen regularly to avoid dust covering which will affect the filter screen effect. When the operating environment is dusty, the cleaning frequency should be increased appropriately. After removing the filter screen, do not touch the fins of the indoor unit to avoid scratching.
Clean the unit
Diagram showing a unit being wiped with a damp cloth, with a temperature indicator "<40°C (104°F)".
Wring it dry and gently wipe the surface of the unit.
Tip: Wipe frequently to keep air conditioner clean and good appearance.
Clean the filter
Diagram showing how to take out the filter, clean it with soapy water, and replace it. Includes temperature indicator "<40°C (104°F)" and an arrow indicating the direction of filter removal/replacement.
Tip: When you find accumulated dust in the filter, please clean the filter in time to ensure the clean, healthy and efficient operation inside the air conditioner.
Service and maintenance
When the air conditioner is not in use for a long time, do the following work:
- Take out the batteries of the remote controller and disconnect the power supply of the air conditioner.
When starting to use after long-term shutdown:
- Clean the unit and filter screen;
- Check whether there are obstacles at the air inlet and outlet of indoor and outdoor units;
- Check whether the drain pipe is unobstructed;
- Install the batteries of the remote controller and check whether the power is on.
TROUBLESHOOTING
MALFUNCTION
The appliance does not operate
Strange odor
Noise of running water
A fine mist comes from the air outlet
A strange noise can be heard
Insufficient airflow, either hot or cold
The appliance does not respond to commands
The display is off
Switch off the air conditioner immediately and cut off the power supply in the event of:
POSSIBLE CAUSES
Power failure/plug pulled out.
Damaged indoor/outdoor unit fan motor.
Faulty compressor thermomagnetic circuit breaker.
Faulty protective device or fuses.
Loose connections or plug pulled out.
It sometimes stops operating to protect the appliance.
Voltage higher or lower than the voltage range.
Active TIMER-ON function.
Damaged electronic control board.
Dirty air filter.
Back flow of liquid in the refrigerant circulation.
This occurs when the air in the room becomes very cold, for example in the "COOLING" or "DEHUMIDIFYING/DRY" modes.
This noise is made by the expansion or contraction of the front panel due to variations in temperature and does not indicate a problem.
Unsuitable temperature setting.
Obstructed air conditioner intakes and outlets.
Dirty air filter.
Fan speed set at minimum.
Other sources of heat in the room.
No refrigerant.
Remote control is not close enough to indoor unit.
The batteries of remote control need to be replaced.
Obstacles between remote control and signal receiver in indoor unit.
Active DISPLAY function.
Power failure.
Strange noises during operation.
Faulty electronic control board.
Faulty fuses or switches.
Spraying water or objects inside the appliance.
Overheated cables or plugs.
Very strong smells coming from the appliance.
ERROR CODE ON THE DISPLAY
In case of error, the display on the indoor unit shows the following error codes:
Display | Description of the trouble |
---|---|
E1 | Indoor room temperature sensor fault |
E2 | Indoor pipe temperature sensor fault |
E3 | Outdoor pipe temperature sensor fault |
E4 | Refrigerant system leakage or fault |
E6 | Malfunction of indoor fan motor |
E7 | Outdoor ambient temperature sensor fault |
E0 | Indoor and outdoor communication fault |
E8 | Outdoor discharge temperature sensor fault |
E9 | Outdoor IPM module fault |
EA | Outdoor current detect fault |
EE | Outdoor PCB EEPROM fault |
EF | Outdoor fan motor fault |
EH | Outdoor suction temperature sensor fault |
DISPOSAL GUIDELINE
This appliance contains refrigerant and other potentially hazardous materials. When disposing of this appliance, the law requires special collection and treatment. DO NOT dispose of this product as household waste or unsorted municipal waste.
When disposing of this appliance, you have the following options:
- Dispose of the appliance at a designated municipal electronic waste collection facility.
- When buying a new appliance, the retailer will take back the old appliance free of charge.
- The manufacturer will also take back the old appliance free of charge.
- Sell the appliance to certified scrap metal dealers.
- Disposing of this appliance in the forest or other natural surroundings endangers your health and is bad for the environment. Hazardous substances may leak into the ground water and enter the food chain.
Illustration of a waste bin with recycling symbols, representing proper disposal.