PV String Input Data |
|
|
|
Max. PV Input Power (W) |
210-420(1 Piece) |
210-560(1 Piece) |
210-700(1 Piece) |
Max. PV Input Voltage (V) |
60 |
60 |
60 |
Start-up Voltage (V) |
20 |
20 |
20 |
MPPT Voltage Range (V) |
25-55 |
25-55 |
25-55 |
Rated PV Input Voltage (V) |
42.5 |
42.5 |
42.5 |
Max. Operating PV Input Current (A) |
13 |
13 |
13 |
Max. Input Short Circuit Current (A) |
19.5 |
19.5 |
19.5 |
No. of MPP Trackers/ |
1/1 |
1/1 |
1/1 |
No. of Strings per MPP Tracker |
1 |
1 |
1 |
AC Output Side |
|
|
|
Rated AC Output Active Power (W) |
300 |
400 |
500 |
Max. AC Output Apparent Power (VA) |
300 |
400 |
500 |
Rated AC Output Current (A) |
1.4/1.4 |
1.9/1.8 |
2.3/2.2 |
Max. AC Output Current (A) |
1.4/1.4 |
1.9/1.8 |
2.3/2.2 |
Rated Output Voltage/Range (V) |
220/230 0.85Un-1.1Un |
220/230 0.85Un-1.1Un |
220/230 0.85Un-1.1Un |
Grid Connection Form |
L/N/PE |
L/N/PE |
L/N/PE |
Rated Output Grid Frequency/Range(Hz) |
50/45-55, 60/55-65 |
50/45-55, 60/55-65 |
50/45-55, 60/55-65 |
Max. Unit per Branch |
17 |
13 |
10 |
Power Factor Adjustment Range |
0.9 leading-0.9 lagging |
0.9 leading-0.9 lagging |
0.9 leading-0.9 lagging |
Total Current Harmonic Distortion THDi |
<3% |
<3% |
<3% |
DC Injection Current |
<0.5%In |
<0.5%In |
<0.5%In |
Efficiency |
|
|
|
Max. Efficiency |
96.5% |
96.5% |
96.5% |
Euro Efficiency |
96.0% |
96.0% |
96.0% |
MPPT Efficiency |
>99% |
>99% |
>99% |
Equipment Protection |
|
|
|
DC Polarity Reverse Connection Protection |
Yes |
Yes |
Yes |
AC Output Overcurrent Protection |
Yes |
Yes |
Yes |
AC Output Overvoltage Protection |
Yes |
Yes |
Yes |
AC Output Short Circuit Protection |
Yes |
Yes |
Yes |
Thermal Protection |
Yes |
Yes |
Yes |
DC Terminal Insulation Impedance Monitoring |
Yes |
Yes |
Yes |
Power Network Monitoring |
Yes |
Yes |
Yes |
Island Protection Monitoring |
Yes |
Yes |
Yes |
Earth Fault Detection |
Yes |
Yes |
Yes |
Overvoltage Load Drop Protection |
Yes |
Yes |
Yes |
Interface |
|
|
|
Communication Interface |
WiFi |
WiFi |
WiFi |
General Data |
|
|
|
Operating Temperature Range (°C) |
-40 to +65°C, >45°C Derating |
-40 to +65°C, >45°C Derating |
-40 to +65°C, >45°C Derating |
Permissible Ambient Humidity |
0-100% |
0-100% |
0-100% |
Permissible Altitude (m) |
2000m |
2000m |
2000m |
Noise (dB) |
≤25 |
≤25 |
≤25 |
Ingress Protection(IP) Rating |
IP 67 |
IP 67 |
IP 67 |
Inverter Topology |
Isolated |
Isolated |
Isolated |
Over Voltage Category |
OVC II(DC), OVC III(AC) |
OVC II(DC), OVC III(AC) |
OVC II(DC), OVC III(AC) |
Cabinet Size (WxHxD mm) |
173×158.5×31.5 (Excluding connectors and brackets) |
173×158.5×31.5 (Excluding connectors and brackets) |
173×158.5×31.5 (Excluding connectors and brackets) |
Weight (kg) |
1.85 |
1.85 |
1.85 |
Warranty |
15 Years |
15 Years |
15 Years |
Type of Cooling |
Natural Cooling |
Natural Cooling |
Natural Cooling |
Grid Regulation |
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
Safety EMC/Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |