PV String Input Data |
|
|
|
Max. PV Input Power (W) |
210-420 (2 pcs.) |
210-560 (2 pcs.) |
210-700 (2 pcs.) |
Max. PV Input Voltage (V) |
60 |
80 |
100 |
Startup Voltage (V) |
20 |
20 |
20 |
MPPT Voltage Range (V) |
25-55 |
25-55 |
25-55 |
Nominal PV Input Voltage (V) |
42.5 |
42.5 |
42.5 |
Max. PV Input Current (A) |
13+13 |
13+13 |
13+13 |
Max. Input Short Circuit Current (A) |
19.5+19.5 |
19.5+19.5 |
19.5+19.5 |
Number of MPP Trackers / Number of Strings per MPP Tracker |
2/1 |
2/1 |
2/1 |
AC Output Side |
|
|
|
Nominal AC Output Power (W) |
600 |
800 |
1000 |
Max. AC Output Apparent Power (VA) |
600 |
800 |
1000 |
Nominal AC Output Current (A) |
2.8/2.7 |
3.7/3.5 |
4.6/4.4 |
Max. AC Output Current (A) |
2.8/2.7 |
3.7/3.5 |
4.6/4.4 |
Nominal Output Voltage / Range (V) |
220/230 0.85Un-1.1Un |
Type of AC Connection |
L/N/PE |
Nominal Output Grid Frequency / Range (Hz) |
50/45-55, 60/55-65 |
Max. Unit per Branch |
6 |
6 |
6 |
Adjustable Power Factor Range |
0.9 leading to 0.9 lagging / 0.95 leading to 0.95 lagging |
Total Harmonic Distortion THDi |
<3% |
DC Injection Current |
<0.5%In |
Efficiency |
|
|
|
Max. Efficiency |
96.5% |
96.5% |
96.5% |
Euro Efficiency |
96.0% |
96.0% |
96.0% |
MPPT Efficiency |
>99% |
>99% |
>99% |
Protection Devices |
|
|
|
DC Reverse Polarity Protection |
Yes |
Yes |
Yes |
AC Output Overcurrent Protection |
Yes |
Yes |
Yes |
AC Output Overvoltage Protection |
Yes |
Yes |
Yes |
AC Output Short Circuit Protection |
Yes |
Yes |
Yes |
Thermal Protection |
Yes |
Yes |
Yes |
Insulation Impedance Detection |
Yes |
Yes |
Yes |
Islanding Protection (Anti-Islanding) |
Yes |
Yes |
Yes |
Overvoltage Protection Level |
TYPE II (AC) |
Interface |
|
|
|
Communication Interface |
WiFi |
General Data |
|
|
|
Operating Temperature Range (°C) |
-40 to +65°C, >45°C power derating |
Allowable Ambient Humidity |
0-100% |
Allowable Altitude (m) |
2000m |
Noise (dB) |
≤25 dB(A) |
Protection Rating |
IP67 |
Inverter Topology |
Isolated |
Overvoltage Category |
OVC II (DC), OVC III (AC) |
Enclosure Dimensions (W x H x D mm) |
280.5×190×40 (Excluding connectors and brackets) |
Weight |
3 |
Warranty |
10 Years |
Cooling Mode |
Natural Cooling |
Grid Regulation |
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G98, G99, VDE-AR-N 4105 |
Safety EMC / Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |