Casio Watch Module 950 User Manual
Model: Module 950
Brand: CASIO
Introduction
This manual guides you through the functions and operation of your Casio watch, module 950.
Water Resistance:
- 50M WATER RESISTANT
- 100M WATER RESISTANT
- 200M WATER RESISTANT
- 300M WATER RESISTANT
Note: Regular maintenance (every 2-3 years) is recommended to ensure water resistance.
Basic Operations and Buttons
The watch features several buttons, typically labeled:
- Button D: Often used for starting/stopping or confirming selections.
- Button B: Typically used for mode switching or scrolling through options.
- Button C: Often used for reset or lap/split functions.
- Button A: Usually for setting adjustments or toggling functions (e.g., ON/OFF).
- Button L: May have specific functions depending on the mode.
Screen Indicators:
- "D" indicator: May appear when the "D" button is active or for specific functions.
- "B" indicator: May appear when the "B" button is active or for specific functions.
- "A", "C", "L" indicators: Similar to "D" and "B".
- "ALTI": Indicates Altimeter mode.
- "AUTO": Indicates automatic function.
- "MANUAL": Indicates manual function.
- "FIN": May indicate completion of a process.
- "ERROR": Indicates an error condition.
- "BATTERY": Indicates low battery.
- "HELP": May access help information.
- "----": Placeholder for data or inactive state.
Timekeeping Mode
Setting the Time and Date:
- Press Button D to enter setting mode.
- Use Button B to cycle through the items to be set (e.g., seconds, hours, minutes, year, month, day).
- Use Button A to adjust the selected value.
- Press Button D to exit setting mode.
DST (Daylight Saving Time):
Toggle DST ON/OFF using Button A when the DST indicator is displayed.
12/24 Hour Format:
Select between 12-hour (P for PM) and 24-hour format using Button A.
Alarm Mode
This watch typically supports multiple alarms (e.g., Alarm 1 to Alarm 5) and a daily alarm.
Setting an Alarm:
- Select the desired alarm number using Button B.
- Press Button D to enter setting mode for the selected alarm.
- Set the hour and minute using Button A.
- Press Button D to confirm.
Turning Alarms ON/OFF:
In the alarm mode, use Button A to cycle through alarm ON/OFF settings for each alarm.
Hourly Chime:
Toggle the hourly chime ON/OFF using Button A.
Stopwatch Mode
Measures elapsed time, split times, and lap times.
Operation:
- Press Button D to start the stopwatch.
- Press Button D again to stop.
- Press Button C to reset the stopwatch to zero.
- Press Button B to record lap times or split times while running.
Lap/Split Time Display:
The display may show lap times, split times, and total elapsed time. Use Button B to cycle through these displays.
Lap Memory:
The watch can store a certain number of lap times (e.g., up to 1990 or 2029 records).
Countdown Timer Mode
Sets a time period for automatic countdown.
Setting the Timer:
- Enter Timer mode.
- Press Button D to enter setting mode.
- Set the start time (hours, minutes) using Button A.
- Press Button D to confirm.
Starting/Stopping the Timer:
- Press Button D to start the countdown.
- Press Button D to pause.
- Press Button D to resume.
- Press Button C to stop and reset the timer to its set time.
Auto-repeat:
The timer can be set to automatically repeat the countdown after it finishes.
Altimeter Mode
Measures and displays altitude.
Entering Altimeter Mode:
Press Button B until "ALTI" is displayed.
Measurement Range:
- Altitude: -6000 to 6000 meters (-19680 to 19680 feet).
- Altitude difference: 0 to 6000 meters (0 to 19680 feet).
Units:
Select between meters (m) and feet (ft) using Button A.
Altitude Reference Point:
Set a reference altitude (e.g., sea level) for accurate relative measurements.
Measurement Modes:
- AUTO Mode: The watch automatically measures and updates altitude.
- MANUAL Mode: You manually initiate altitude measurements.
Altitude Difference Measurement:
Measure the difference in altitude between two points.
Altitude Graph:
The watch may display a graph of altitude changes over time.
Other Functions
World Time: Displays time in major cities around the world.
Illumination: Activate the backlight for low-light conditions.
Battery Replacement:
When the "BATTERY" indicator appears, the battery needs replacement. This should be done by a qualified technician to maintain water resistance.
Error Indicators:
If "ERROR" is displayed, refer to troubleshooting steps.
Specifications
Feature | Specification |
---|---|
Module | 950 |
Water Resistance | 50M, 100M, 200M, 300M (depending on model variant) |
Battery Type | Lithium battery (e.g., R2025) |
Accuracy | ±15 seconds per month |
Operating Temperature | -20°C to 60°C (-4°F to 140°F) |
Altitude Measurement Range | -6000 to 6000 m (-19680 to 19680 ft) |
Altitude Measurement Unit | 1 m (or 5 ft) |
Altitude Difference Measurement Unit | 1 m (or 5 ft) |
Barometric Pressure Measurement Range | 460 to 1100 hPa/mbar (13.55 to 32.45 inHg) |
Barometric Pressure Measurement Unit | 1 hPa/mbar (0.05 inHg) |
Stopwatch | 1/100 second; Measuring capacity: 23:59'59.99" |
Alarm | Daily alarm, Hourly chime |
Countdown Timer | Preset times up to 24 hours; Auto-repeat |
Year Range | 1990 to 2029 |
Troubleshooting
- "ERROR" Display: May indicate a sensor issue or incorrect operation. Consult the manual or service center.
- "BATTERY" Display: Battery is low and needs replacement.
- Inaccurate Readings: Ensure the watch is calibrated correctly, especially for altitude and temperature.