Bromic Refrigeration

Confidence and control.

INSTRUCTION MANUAL

VERTICAL DISPLAY FRIDGES

3736234, 3736235, 3736236, 3736237

1. PREFIX

This manual contains important information about the installation, operation, and maintenance of Bromic display chillers. Please pay close attention to the important safety information shown throughout this instruction manual. Any safety information will be accompanied by the following safety alert symbols:

DANGER, WARNING, IMPORTANT

2. IMPORTANT NOTES AND WARNINGS

Warning: Risk of fire / Flammable materials

3. PRODUCT OVERVIEW

Part Number GM1100LS-NR GM1100LB-NR GM1100S-NR GM1100B-NR
Height, mm 2054 2054 2095 2095
External Dimension Width, mm 1200 1200 1200 1200
Depth, mm 775 775 775 775
Capacity Litres 1065 1065 1097 1097
Weight Kg 195 195 195 195
Display lightbox Type Yes Yes No No
Temp. Range Degree Celsius -1 to +5°C -1 to +5°C -1 to +5°C -1 to +5°C
Climate Class* Class 3M1 3M1 3M1 3M1
Max Ambient Degree Celsius 43°C 43°C 43°C 43°C
Internal Light Type LED LED LED LED
Shape Flat Flat Flat Flat
Door Safety Glass Yes Yes Yes Yes
Self-Closing Yes Yes Yes Yes
Shelves Qty 5 plus base 5 plus base 5 plus base 5 plus base
Castor Type Yes Yes Yes Yes
Refrigerant R290 R290 R290 R290
Refrigeration Charge, g 145 145 145 145
Controller Type Digital Digital Digital Digital
Plug Rating 10A 10A 10A 10A
Colour Silver Black Silver Black
Extra Care Warranty Years 5 5 5 5

4. INSTALLATION

Locating the Cabinet

Ensure the following instructions are observed as this is vital for proper and trouble-free operation.

Ventilation

Power Supply

Before Operating

5. OPERATION

Start-up

Using the Controller

For Danfoss controller (as shown below), adjusting the temperature set point following below process:

The display shows the current temperature.

Press 'up/down' to access set point.

Press 'up/down' to adjust set point.

After 30 seconds, the display automatically reverts to showing the current temperature.

Press the 'light' button to turn on/off the internal light.

6. PRODUCT LOADING AND STORAGE

IMPORTANT: Run the refrigerator for at least 24 hours before loading.

WARNING: Do not store explosive substances such as aerosol cans with a flammable propellant inside the appliance.

Start-up

NOTE: Bromic cannot be responsible for loss of stock or damage to stock.

7. MAINTENANCE

WARNING: Disconnect the appliance from the power supply before performing any maintenance. Never unplug the appliance by pulling on the cord. Always grasp the plug firmly and pull straight out of the outlet.

WARNING: Exposure to significant water ingress will void warranty and cause potential safety issues. If the unit should be exposed to water, please contact the manufacturer immediately.

IMPORTANT: Warranty may be void if there is no evidence of preventative maintenance is performed on the appliance.

Cleaning the Cabinet

Defrosting

Defrosting is carried out automatically, there is no need for manual defrost.

8. TROUBLESHOOTING

IMPORTANT: Repairs on the unit must be carried out by an authorised and licensed person only. Contact the manufacturer or an approved service agent for any repairs needed.

Symptom Possible Cause(s) Solution
Unit does not work A. No power supply A. Check power supply and green indicator
Internal Temperature Too High A. Ambient temperature too high
B. Inadequate ventilation
C. Wall clearances below minimum distance
D. Incorrect dial position
E. Door not closed properly
F. Dirty condenser
A. Relocate unit
B. Keep ventilation slots free
C. Adjust to minimum clearance
D. Adjust controller set point
E. Ensure door is closed properly
F. Clean condenser
Internal Temperature Too Low A. Set temperature too low A. Adjust temperature set point
Odour inside cabinet A. Cabinet dirty A. Clean
Lid difficult to open A. Normal
B. Hinge damage
A. It is normal for the lid to be difficult to open just after you closed it
B. Inspect hinge and call service hotline
Noisy A. Unlevel surface A. Relocate unit

9. ENVIRONMENTAL AND DISPOSAL NOTES

These refrigerated cabinets are designed to high standards of environmental protection and recycling convenience. Cyclopentane, an environmentally friendly foaming agent, has been used. Cyclopentane is distinguished by zero ozone depletion potential (ODP) and zero global warming potential (GWP). The refrigerant used and contained within a hermetically tight circuit is environmentally friendly and does not contain chlorine and zero ODP.

The device must be disposed of in accordance with applicable regulations. The WEEE regulations must be observed.

In the interest of preventing environmental nuisance and promoting re-use of the high quality materials employed, used refrigeration equipment must be collected for expert disposal and recycling. Therefore, observe the following disposal regulations:

Warning: Risk of fire / Flammable materials

10. WARRANTY

All Bromic products are manufactured to the highest quality standard and are supported by our Extra Care Service Warranty, including guarantees against any material or workmanship defects; guarantees that cannot be excluded under Australian Consumer Law.

Warranty Terms vary across the range. Please ensure you are familiar with the Terms and Conditions that apply to the purchase of your Bromic product by referring to the Warranty Policy included with your purchased product.

Alternatively, you can also download the Warranty Policy at www.bromicgroup.com/warranty-information

HOW TO PLACE A SERVICE REQUEST

SERVICE REQUEST PRIORITY

PRIORITY A SERVICE
When the unit is NOT performing its primary function such as cooling or heating, or presents an OH&S or food safety risk.

PRIORITY B SERVICE
When the unit is performing its primary function, and presents no OH&S or food safety risk. i.e. lights, gaskets. locks, door adjustment.

SERVICE CALL PLACED BEFORE MIDDAY
Priority A - Technician to attend site within 4 hours
Priority B - Technician to attend site within 8 business hours

SERVICE CALL PLACED AFTER MIDDAY
Priority A - Technician attends site before midday on the following business day
Priority B - Technician attends site before 4pm on the following business day

Models: 3736234, 3736235, 3736236, 3736237, 3736234 Vertical Display Fridges, 3736234, Vertical Display Fridges, Display Fridges, Fridges

File Info : application/pdf, 16 Pages, 1.08MB

PDF preview unavailable. Download the PDF instead.

User-Manual D-Class-Premium-Uprights 0725 WIP GM1100s

References

GPL Ghostscript 9.55.0 Adobe InDesign 20.5 (Windows)

Related Documents

Preview Bromic Refrigeration Pizza Prep Fridges Instruction Manual (Models 3735801 & 3735802)
Comprehensive instruction manual for Bromic Refrigeration Pizza Prep Fridges, covering installation, operation, maintenance, troubleshooting, and warranty information for models 3735801 and 3735802.
Preview Bromic Refrigeration BB0200GD-NR-1 Back Bar Glass Door Display Fridge 190L (Hinged) Specifications
Detailed specifications and dimensions for the Bromic Refrigeration BB0200GD-NR-1 Back Bar Glass Door Display Fridge 190L (Hinged). Features include double-glazed safety glass, precise digital temperature control, and high-impact LED lighting.
Preview Bromic Deli Displays Instruction Manual
Comprehensive instruction manual for Bromic Deli Displays, covering installation, operation, maintenance, and troubleshooting for models DD1250SG-NR, DD1250CG-NR, DD1875SG-NR, DD1875CG-NR, DD2500SG-NR, and DD2500CG-NR.
Preview Bromic Refrigeration FD4T1200C-NR 4-Tier Cake Display - Product Overview and Specifications
Detailed information on the Bromic Refrigeration FD4T1200C-NR, a 1200mm wide, 4-tier cake display unit. Features include toughened safety glass, adjustable shelves, sliding rear doors, LED lighting, and soft-cool refrigeration technology. Compliant with Australian safety standards.
Preview Bromic IM0084HSC-HE Self-Contained Hollow Cube Ice Machine - 63kg/24h
Detailed specifications and features for the Bromic IM0084HSC-HE self-contained hollow cube ice machine. This unit produces 63kg of ice per 24 hours with a 20kg storage capacity, featuring stainless steel construction, Agion antimicrobial treatment, and a 3-year parts warranty.
Preview Bromic GM1000LBCAS Upright Display Fridge - 960L, 2 Doors, Flat Glass
Detailed specifications and features of the Bromic GM1000LBCAS upright display fridge, a 960L, 2-door unit with flat glass and a cassette system for easy maintenance. Includes information on energy efficiency, internal lighting, and temperature control.
Preview Bromic MED0140GD-NR Medical and Vaccine Fridges Instruction Manual
Comprehensive instruction manual for the Bromic MED0140GD-NR Medical and Vaccine Fridge, covering installation, operation, maintenance, troubleshooting, and warranty.
Preview Bromic Refrigeration: Instruction Manual for Semi Verticals and Full Height Multidecks
Comprehensive instruction manual from Bromic Refrigeration covering installation, operation, maintenance, and troubleshooting for their Semi Vertical and Full Height Multideck refrigerated display units. Includes product specifications and warranty information.