Bromic Refrigeration Instruction Manual

Model: MED0140GD-NR

1. Prefix

This manual contains important information regarding the installation, operation, and maintenance of Bromic MediFridge™. Please pay close attention to the safety information provided throughout this manual. Safety information is accompanied by the following alert symbols:

DANGER, WARNING, IMPORTANT

2. Important Notes and Warnings

Caution: Risk of fire ⚠️

3. Product Overview

SpecificationValue
Part NumberMED0140GD-NR (3736257)
External Dimensions (H x W x D)820 mm x 595 mm x 643 mm
Capacity225 Litres
Weight40 Kg
Temperature Range+2°C to +8°C
Temperature TypeDigital
Ambient Temperature Type32°C
Climate Class4M2
Energy Consumption1.396 kWh/24h
RefrigerantR600a
Refrigerant Charge100W
Air CirculationFan Forced
Current1.2A
Electrical Voltage220-240V
Frequency50 Hz
Plug LocationRear, bottom right
ColourWhite
Internal Light TypeLED
Number of Doors1
Glass TypeDouble glazed Low-E Glass + Argon Gas
Door StyleHinged
Door LockYes
Door Self ClosingYes
Door ShapeFlat
Door Swing Dimensions (H)590 mm
Total Depth of Door Open1990 mm
Number of Shelves incl. base per Door4
Shelf Dimensions (W x D)500(w) x 355(d) mm
Temp, Door, Audible & Visual Alarm (Y/N)Yes

4. Installation

Note: The maximum ambient temperature for the refrigerator is 30°C. Conditions outside this temperature will result in cabinet temperatures outside the required 2 to 8°C range. Bromic recommends that the refrigerator is installed at an ambient temperature of 20 to 25°C.

Locating the Cabinet

Ensure the following instructions are observed for proper and trouble-free operation:

Diagrams showing airflow around the unit and clearance requirements:

Ventilation

Ensure the following instructions are observed for proper and trouble-free operation:

Diagrams showing required clearances:

Power Supply

Diagrams showing correct and incorrect power connections:

Before Operating

5. Operation

Start-up

Setting the Temperature

Note: The controller is factory set at 4°C. The controller is programmed to control cabinet temperatures between 2 to 8°C.

Control Panel Diagram:

To set the temperature:

  1. Press the SET button.
  2. The set temperature will be displayed.
  3. Press ▲ or ▼ to adjust the temperature.
  4. Press the SET button to exit. If no further buttons are pressed within 6 seconds, the cabinet temperature will be displayed.

Display the Product Sensor Temperature

  1. Press the ❄️ button.
  2. The product temperature will flash and display.
  3. After 6 seconds, the cabinet temperature will be displayed.

Operating the Light

  1. Press the ? button to turn internal LED lights ON or OFF.

MAX / MIN Temperature Recording

IMPORTANT: Record the maximum and minimum temperatures two (2) times a day. Recordings should be taken before the first door opening of the day.

  1. Press the HI/LO button once.
  2. The highest temperature recording will be displayed.
  3. Press the HI/LO button again while the highest temperature recording is displayed.
  4. The lowest temperature recording will be displayed.
  5. To clear the MAX/MIN recording - Hold the HI/LO button for 6 seconds.
  6. The display will flash for 3 seconds and the buzzer will sound, clearing the previous highest and lowest temperature recordings.
  7. The current cabinet temperature will be recorded.

Controller Alarms

If alarms persist, contact the manufacturer or an approved service agent.

CodeAlarm TypeCorrective Action
HICabinet high temperature alarm
  • Check if there is adequate ventilation.
  • Check if there is free circulation of air inside the cabinet.
  • Check and clean condenser coil and fan.
  • Check if door is shut.
LOCabinet low temperature alarm
  • Check if door is shut.
1HCabinet temperature sensor short circuit
  • Unplug the unit for 1 minute then reconnect to power.
1LCabinet temperature sensor open circuit
2HProduct temperature sensor short circuit
  • Check if there is adequate ventilation.
  • Check if there is free circulation of air inside the cabinet.
  • Check and clean condenser coil and fan.
  • Check if door is shut.
2LProduct temperature open circuit
H2Product high temperature alarm
  • Check if there is adequate ventilation.
  • Check if there is free circulation of air inside the cabinet.
  • Check and clean condenser coil and fan.
  • Check if door is shut.
dRDoor open alarm
  • Close the door.

6. Product Loading and Storage

WARNING: Failure to follow the guidelines below will result in cabinet temperatures above 8°C.

IMPORTANT: Run the refrigerator for at least 2 hours before loading.

Start-up

Note: Bromic cannot be responsible for loss of stock or damage to stock.

Please refer to the 'National Vaccine Storage Guidelines: Strive for 5' for more information on vaccine storage and handling or contact your local state or territory health department. (https://www.health.gov.au/internet/immunise/publishing.nsf/content/IMM77-cnt)

7. Maintenance

WARNING: Disconnect the appliance from the power supply before performing any maintenance. Never unplug the appliance by pulling on the cord. Always grasp the plug firmly and pull straight out of the outlet.

WARNING: Exposure to significant water ingress will void warranty and cause potential safety issues. If the unit is exposed to water, please contact the manufacturer immediately.

IMPORTANT: Warranty may be void if there is no evidence of preventative maintenance performed on the appliance.

Cleaning the Cabinet

Condenser Coil

IMPORTANT: The condenser coil must be cleaned with a vacuum or brush once a month. The condenser coil must be cleaned regularly to maintain performance and minimize power consumption. A poorly maintained condenser coil can lead to unit failure and cabinet temperatures above 8°C.

Extended Defrosting

The evaporator (cooling) coil of the refrigerator may build up a layer of ice over time, reducing performance. Inspect the evaporator coil for ice build-up regularly. For extended defrosting, turn off the unit with the door opened for a period of 24 hours.

8. Troubleshooting

IMPORTANT: Repairs on the unit must be carried out by an authorized and licensed person only. Contact the manufacturer or an approved service agent for any repairs needed.

SymptomPossible Cause(s)Corrective Action
Unit does not workA. No power supplyA. Check power supply
Cabinet Temperature Too HighA. Ambient temperature too highA. Relocate unit
B. Inadequate ventilationB. Keep ventilation slots free
C. Wall clearances below minimum distanceC. Adjust to minimum clearance
D. Dirty condenser coilD. Clean
E. Ice build-up on evaporator coilE. Perform extended defrosting
Cabinet Temperature Too LowA. Set temperature too lowA. Adjust set temperature
Cabinet lights not workingA. Light not switched on
B. Light is faulty
A. Switch on
B. Replace light
Drip tray overflowingA. Extreme operating conditionA. Relocate unit
Odour inside cabinetA. Cabinet dirtyA. Clean

9. Schematic Diagram

Diagram showing the electrical components of the refrigerator, including:

10. Environmental and Disposal Notes

These refrigerated cabinets are designed to high standards of environmental protection and recycling convenience. Cyclopentane, an environmentally friendly foaming agent, has been used. Cyclopentane has zero ozone depletion potential (ODP) and zero global warming potential (GWP). The refrigerant used in the hermetically sealed circuit is environmentally friendly, contains no chlorine, and has zero ODP.

The device must be disposed of in accordance with applicable regulations. WEEE regulations must be observed.

To prevent environmental nuisance and promote the reuse of high-quality materials, used commercial refrigeration equipment must be collected for expert disposal and recycling. Observe the following disposal regulations:

Children are often unable to recognize the dangers associated with commercial refrigeration equipment. Proper supervision must be maintained, and children must be prevented from playing with discarded refrigerated cabinets.

11. Warranty

All Bromic products are manufactured to the highest quality standards and are supported by our Extra Care Service Warranty, including guarantees against material or workmanship defects that cannot be excluded under Australian Consumer Law.

Warranty terms vary across the range. Please ensure you are familiar with the Terms and Conditions applicable to your Bromic product purchase by referring to the Warranty Policy included with your product.

Alternatively, you can download the Warranty Policy at: https://bromicrefrigeration.com.au/extra-care-warranty

How to Place a Service Request

Compliance Plate Example:

P/N#: 3735161-NR

Serial number: ST21113A01GH65T004

Description: CHILLER UC0650SD-NR, UPRIGHT 1DR 650L S/S

Model: UC0650SD-NR

Description: Ventilated

Electrical: AC220-240V 50Hz 1Ph

Made in China

Bromic Model: UC0650SD-NR

Bromic Part no.: 3735161-NR

Refrigerant type: R290

Rated Voltage: AC220~240V

Frequency: 50 Hz

Power: 120 W

Rated current: 3.0A

Net Weight: 135Kg

Rated Wattage: 305W

Max Lamp Wattage: 1.5W

Made in China

Service Request Priority

Priority A Service: When the unit is NOT performing its primary function (e.g., cooling or heating), or presents an OH&S or food safety risk.

Priority B Service: When the unit is performing its primary function and presents no OH&S or food safety risk (e.g., lights, gaskets, locks, door adjustment).

Service Call Placement Times:

Models: MED0140GD-NR Bromic Medi Fridge, MED0140GD-NR, Bromic Medi Fridge, Medi Fridge, Fridge

File Info : application/pdf, 18 Pages, 1.02MB

PDF preview unavailable. Download the PDF instead.

User-Manual MED0140GD-NR 0725 Final web

References

GPL Ghostscript 9.55.0 Adobe InDesign 20.4 (Windows)

Related Documents

PreviewBromic MediFridge Vaccine Fridge MED0140GD-NR: Features & Specifications
Detailed overview of the Bromic MediFridge 145L vaccine refrigerator (MED0140GD-NR), highlighting features like digital temperature control, fan-forced cooling, natural refrigerant, QCPP compliance, and specifications.
PreviewBromic Refrigeration Underbench Fridges and Freezers Instruction Manual
Comprehensive instruction manual for Bromic Refrigeration's underbench fridges and freezers, covering installation, operation, maintenance, troubleshooting, and warranty information for models like UBC and UBF series.
PreviewBromic Refrigeration Chest Freezer Instruction Manual
Comprehensive instruction manual for Bromic Refrigeration chest freezers, covering installation, operation, maintenance, and troubleshooting. Includes product specifications and warranty information.
PreviewBromic Refrigeration Pizza Prep Fridges Instruction Manual (Models 3735801 & 3735802)
Comprehensive instruction manual for Bromic Refrigeration Pizza Prep Fridges, covering installation, operation, maintenance, troubleshooting, and warranty information for models 3735801 and 3735802.
PreviewBromic Refrigeration BB0200GD-NR-1 Back Bar Glass Door Display Fridge 190L (Hinged) Specifications
Detailed specifications and dimensions for the Bromic Refrigeration BB0200GD-NR-1 Back Bar Glass Door Display Fridge 190L (Hinged). Features include double-glazed safety glass, precise digital temperature control, and high-impact LED lighting.
PreviewBromic Deli Displays Instruction Manual
Comprehensive instruction manual for Bromic Deli Displays, covering installation, operation, maintenance, and troubleshooting for models DD1250SG-NR, DD1250CG-NR, DD1875SG-NR, DD1875CG-NR, DD2500SG-NR, and DD2500CG-NR.
PreviewBromic Refrigeration Semi Verticals and Full Height Multidecks Instruction Manual
Comprehensive instruction manual for Bromic Refrigeration's Semi Verticals and Full Height Multidecks, covering installation, operation, maintenance, and troubleshooting.
PreviewBromic Refrigeration: Instruction Manual for Semi Verticals and Full Height Multidecks
Comprehensive instruction manual from Bromic Refrigeration covering installation, operation, maintenance, and troubleshooting for their Semi Vertical and Full Height Multideck refrigerated display units. Includes product specifications and warranty information.