Manrose Weatherproof Louvre Grilles

Installation Instructions

Diagram Description

The diagram illustrates the installation of a Manrose Weatherproof Louvre Grille. It shows a cross-section of the grille frame fixed to a building substrate, such as concrete, timber, or brick, using appropriate fixings. A bead of silicone sealant is applied around the perimeter of the frame to ensure weathertightness. The diagram indicates the use of fixing screws to secure the grille to the substrate and highlights the importance of suitable fixings and sealant application.

Key components shown:

  • Substrate: Labeled "CONCRETE/TIMBER/BRICK USE APPROPRIATE FIXING"
  • Grille Frame
  • Fixing Screw: Labeled "FIXING SCREW" and "USE APPROPRIATE FIXING SCREW"
  • Silicone Sealant: Labeled "SILICONE SEALANT"

Applicable Products

  • DCT3709
  • DCT4069
  • DCT4070

Installation Steps

  1. This weatherproof louvre grille is supplied complete with perimeter frame and four fixing screws.
  2. Ensure that the supplied fixing screws are suitable for the application and for the substrate that the grille is being affixed to. Alternative fixings should be manufactured from stainless steel.
  3. The external frame surrounding the grille must be waterproof with a suitable silicone sealant to ensure weathertightness.
  4. Once all four corners to the substrate are fixed using the supplied screws or suitable alternative fixings and the appropriate silicone sealant has been applied around all 4 sides of the perimeter frame, a visual inspection must be made to confirm weathertightness.

Important Note

Due to the many building variables and different available cladding systems, it is recommended that this product be installed by a licensed building practitioner. The information contained herein should be used strictly as a guideline only.

Models: DCT3709 Weatherproof Louvre Grilles, DCT3709, Weatherproof Louvre Grilles, Louvre Grilles, Grilles

File Info : application/pdf, 1 Pages, 126.29KB

PDF preview unavailable. Download the PDF instead.

PUB1814 2311 Manrose Weatherproof Louvre Grilles IM

References

Adobe PDF Library 17.0 Adobe InDesign 19.0 (Windows)

Related Documents

Preview Manrose Continuous Extract Fans: Selection Guide for Hyper150 EC, Blue Jet, Intelligent, Genius, and MultiVent
Explore Manrose's range of continuous extract ventilation fans, including Hyper150 EC, Blue Jet, Intelligent, Genius, and Vent-Axia MultiVent. Features include EC technology, manual boost, humidity control, and app connectivity for improved indoor air quality.
Preview Manrose Through Roof Fan Cowls & Fan Kits Installation Guide
Comprehensive installation guide and technical specifications for Manrose through roof fan cowls and fan kits. Covers electrical connections, wiring diagrams, safety precautions, and compliance with NZ Building Code and Healthy Homes standards. Includes model details for axial EC and centrifugal fans.
Preview MANROSE Through Roof Fans Installation Guide
Installation instructions for MANROSE Through Roof Fans, detailing electrical connections, wiring, mounting, and safety precautions for models FAN0530, FAN0532, FAN0534, FAN0535, DCT0189, FAN0740, FAN0967, FAN1009, FAN0529, FAN1002.
Preview MANROSE Jestream Hand Dryer Installation, Specifications, and Warranty Guide
Official installation instructions, technical specifications, maintenance advice, and warranty details for the MANROSE Jestream Hand Dryer models FAN7427 and FAN7428.
Preview Manrose Extraction Fan Selection Guide: NZ G4 Building Code & Healthy Homes Compliance
Manrose presents a comprehensive guide for selecting extraction fans, ensuring compliance with New Zealand's G4 Building Code and Healthy Homes Standards. This document details fan selection criteria, ventilation requirements for bathrooms and kitchens, and showcases Manrose's extensive range of fans, including Contour, Hyper150 EC, Mixflo, and more. Essential for installers and homeowners seeking optimal indoor air quality and regulatory adherence.
Preview Manrose 125mm Low Profile Inline Extraction Fan Kit Installation and Warranty
Comprehensive guide for installing and understanding the warranty for the Manrose 125mm Low Profile Inline Extraction Fan Kit, including technical specifications, safety precautions, and regulatory compliance information.
Preview Manrose Continuous Extract Selection: Ventilation Fans for Healthy Homes
Manrose offers a comprehensive range of continuous extract ventilation solutions for modern, well-sealed homes, promoting fresh air and healthy indoor environments. This selection guide details products like the dMEV-C 125, MultiVent, AIRBUS DC, EC CONTOUR, Heatforce DC, INTELLIVENT, HYPER150 EC, BLUE JET, and Genius. Featuring ECO, EC/DC, and low energy motors, these fans are designed for efficient humidity and temperature management, meeting G4 Building Code and Healthy Homes Standards.
Preview Manrose Conceal Silent Fans 100mm Installation Guide: Standard & Timer Models
Comprehensive installation guide for Manrose Conceal Silent Fans (100mm Standard and Timer models, including CSF100T). Covers essential safety, location suitability, detailed wiring instructions for standard and timer models, panel/ceiling and wall mounting procedures, speed setting adjustments, and timer configuration. Ensures safe and correct installation of ventilation fans.