Von Duprin 94/9547/47-F Concealed Vertical Rod Device
Specifications for Door Openings 2' 6" up to 2' 9¾" Wide
General Information & Notes
Product: 94/9547/47-F Concealed Vertical Rod Device
Application: Designed for door openings ranging from 2 feet 6 inches (2' 6") up to 2 feet 9 ¾ inches (2' 9¾") wide.
References:
- See Master Sheet #10001 for Suggested Reinforcing.
- For door opening widths of 2 feet 10 inches (2' 10") and larger, refer to template #10324.
Template Details:
- Template Number: 10375_d Sht 1
- Date: 08-07-19
Installation Dimensions and Preparations (Sheet 1)
This section details the critical dimensions and hole preparations required for installing the concealed vertical rod device onto a door stile.
Latch Case and Device Mounting
- Minimum Latch Case Width: 1 3/8 inches
- Latch Case Width: 11/16 inches
- Distance from Stile Edge to Latch Case Center: 7/8 inches
- Distance from Top/Bottom of Latch Case to Stile Edge: 2 inches
- Vertical Positioning (Latch Case Application): 39 5/8 inches from the finished floor.
- Stop Height: 7/16 inches from the stile edge.
Hole Preparations
- #10-24 TAP, 4 HOLES: Located 7/8 inches from the edge, 7/16 inches from the top/bottom.
- 1/2" DIA. HOLE: For ratchet release, to be prepared at installation.
- #10-24 TAP THRU REINFORCING ONLY: 8 places, positioned 33 inches from the finished floor.
- #10-24 TAP, 2 HOLES: For frame at the top.
Reinforcing and Door Edge
- 8 GAGE REINFORCING: Two places, 1 1/16 inches from the stile edge. Reinforcing is noted as required.
- Front Panel Cutout Edges: Edges must be rolled over all around four sides and corners to prevent sharp edges.
Spacers and Undercuts
- Spacer Requirement: A 1/2 inch spacer is required full width under the mounting pads for doors that are 2 1/4 inches thick.
- Undercut Requirement: A 1/4 inch undercut is required for this device.
Strike Application
- Refer to 385-A or 304-L strike application details.
Orientation Note
The diagram shows the Left Hand Reverse (LHR) configuration; the Right Hand Reverse (RHR) configuration is opposite.
Clearance and Side View (Sheet 2)
This section provides a cross-sectional view of the door stile, illustrating clearance requirements.
- Clearance Requirement: Provide opening clearance at the hinge side for a 1" x 2" x 2 1/2" control box for the "EL" device.
Key dimensions shown in this view include door thickness references: (4"), (1"), 5/8", 5/32", and (1/4").
The diagram labels indicate the "FRONT OF DOOR" and a "SEAT" for the device.