Aiphone RY-WL/C Dual Door Release Adaptor
Instructions
Product Overview
The Aiphone RY-WL/C is a dual door release adaptor designed to work with Aiphone intercom systems. It allows for the selective release of two different doors. When a user activates the door release button on a master unit, the RY-WL/C ensures that only the door corresponding to the established communication path is released.
Note: This adaptor does not provide door release functionality for optional audio-only door stations.
Wiring Diagrams and System Compatibility
The RY-WL/C interfaces with Aiphone door stations and door strikes. It is compatible with both the IE-2AD and MY-2CD series door stations.
Wiring with IE-2AD System
In an IE-2AD system, the RY-WL/C connects to Door Station #1 and Door Station #2. Each door strike is connected to the RY-WL/C. The power supply (12-24V DC) connects to the RY-WL/C. The IE-2AD unit itself is also connected to the system. The diagram shows specific terminal connections for these components.
Important Note: The IE-2AD must be powered with DC voltage when using the RY-WL/C.
Wiring with MY-2CD System
Similarly, the RY-WL/C connects to MY-door stations and their respective door strikes in a MY-2CD system. The diagram illustrates connections between the MY-door station (terminals A1, A2), the RY-WL/C, and the door strikes. A PS-18C power supply is shown connected to the RY-WL/C. The MY-2CD unit is also part of this configuration.
Note: CN-6 is an internal connection on the XC-254. The 3-wire connector supplied with the RY-WL/C is used for these connections.
General Wiring Notes:
- The 3-wire connector supplied with the RY-WL/C is not required for connection to the IE-2AD.
- Any IE series or MY series door station can be used with this system.
- The diagrams primarily show wiring concerning the RY-WL/C. For complete installation information, refer to the respective system instructions.
RY-WL/C Terminal Definitions
The RY-WL/C features the following terminals:
- L1: Normally open contact closure for door #1.
- L2: Normally open contact closure for door #2.
- L-: Trigger control for door release.
- -: Negative (for power supply connection).
- 1: Sensing control for door #1.
- 2: Sensing control for door #2.
Converting RY-WL/C Contacts to Normally Closed
To configure the RY-WL/C contacts for normally closed operation, follow these steps:
- Locate the CP-001 circuit board inside the RY-WL/C unit.
- Carefully cut the traces on the CP-001 board that are indicated by an "X" symbol.
- Solder a jumper wire between each pair of adjacent open holes located on each side of the board.
- After these modifications, the external connection points remain unchanged.