ASTROAI USER MANUAL DIGITAL MULTIMETER

? NOTE: Fully read and understand this manual before using this instrument.

The meter can not be used to test AC current and can not be used to test AC voltage like the voltage of RECEPTACLE WHEN the dial is located in the DC current range.

⚠️ WARNING: To avoid possible electric shock or personal injury, and to avoid possible damage to the Meter or to the equipment being tested, adhere to the following rules:

DIGITAL MULTIMETER DIAGRAM

The multimeter features the following components:

GETTING TO KNOW YOUR DEVICE

Digital LCD Display

Displays a variety of information including results from test measurements, low battery indicator, and error display. Comes with a backlight for easier reading in dim conditions.

Data Hold Button

When taking measurements and recording results, it is often easier to use the data hold function to freeze the data being displayed on the digital display. Even when the test leads are removed from the measurement source, the results will continue to display to take easier notes. Press the Data Hold Button once to lock in the results, then press it again to reset the reading. A "1" will be displayed until the probes are used to take the next reading.

Backlight Button

Use the backlight button to make the display even easier to read. Just press the backlight button once to turn the light on; it will slowly dim until it is completely off. If you need to use the light for longer, just press the button again while the light is dimming or after it has turned off and it will brighten back up to full capacity again. If you need to turn off the backlight quickly, moving the rotary switch to the OFF position will turn off the screen and backlight.

Function and Range Switch

This device is known as a manual ranging multimeter, meaning the user must select the correct range for measurement. If you know the function and range you are measuring, turn the dial to that range. If unsure, begin at the highest range for that function and decrease it until a satisfactory reading is obtained.

COM Terminal

COM is short for "Common Terminal". This terminal is the plug on the right of the multimeter. The black lead is always plugged into this terminal.

VΩmA Terminal

This terminal is located in the middle of the multimeter and is meant for most measurements, as long as the test does not exceed 200mA. The red plug goes in this terminal.

10A Terminal

This terminal is located on the left side of the meter and is meant for measuring currents over 200mA but below 10A. The red plug goes in this terminal. Be careful when using this terminal due to the energy it handles. Limit testing to 10 seconds at a time, with at least 15 minutes between tests, to prevent overloading or overheating.

ELECTRICAL SYMBOLS

〰️ AC (Alternating Current) ? Low Battery
➖ DC (Direct Current) ➡️ Diode
〰️➖ AC and DC ? Fuse
? Earth Ground ? Continuity Test
⊓ Square Wave ?? CE Complies with EU directives
□ Double Insulated ❗ Warning

GENERAL SPECIFICATIONS

Max Display: LCD 3 ½ digits (1999 count) 0.6” high
Polarity: Automatic, indicated negative, assumed positive.
Measure Method: Double integral A/D switch implement
LCD Size: 49 x 17mm
Sampling Speed: 2 times per second
Over-Load Indication: "1" is displayed
Operating Environment: 32~104 °F; 0~40 °C, at <80%RH
Storage Environment: 14~122 °F; -10~50 °C, at <85%RH
Power: 1 x 9V Battery NEDA 1604/6F22/006P
Static Electricity: About 4mA
Product Size: 130 x 73 x 37mm
Product Net Weight: 145g (including battery)

TECHNICAL SPECIFICATIONS

Accuracies are guaranteed for 1 year, with storage conditions of 23°C±5°C, less than 80%RH.

DC VOLTAGE

Range Resolution Accuracy Overload Protection
200mV 100µV ± (0.5%+3) 220V rms AC
2000mV 1mV ± (0.8%+2) 500V DC / 500V rms
20V 10mV
200V 100mV ± (0.8%+3)
500V 1V ± (0.8%+3)

AC VOLTAGE

Range Resolution Accuracy Overload Protection
200V 100mV ± (2.0%+10) 500V DC / 500V rms
500V 1V ± (2.0%+10)

Response: Average response, calibrated in rms of a sine wave. Frequency Range: 45Hz ~ 450Hz

AUDIBLE CONTINUITY

Range Description Overload Protection
? Built-in buzzer sounds if resistance is less than 30±20Ω 15 second maximum exposure to 220V rms

DC CURRENT

Range Resolution Accuracy Overload Protection
2000µA 1 µA ± (2.0%+5) 500mA, 250V fuse
20mA 10µA
200mA 100µA ± (2.5%+5) unfused
10A 10mA ± (2.5%+5) unfused

Measured Voltage Drop: 200mV

RESISTANCE

Range Resolution Accuracy Overload Protection
200Ω 0.1Ω ± (1.5%+5) 15 seconds maximum exposure to 220Vrms
2000Ω ± (1.0%+4)
20KΩ 10Ω ± (1.0%+4)
200KΩ 100Ω ± (1.0%+10)
20MΩ 10KΩ ± (1.0%+10)
200MΩ 100KΩ ± (1.0%+10) 15 seconds maximum exposure to 220Vrms

Maximum Open Circuit Voltage: 3V

OPERATING INSTRUCTIONS

DC & AC VOLTAGE MEASUREMENT

  1. Connect the red test lead to the “VΩmA” jack (center plug). Connect the black test lead to the "COM" jack (right plug).
  2. Set the manual range switch to the desired Voltage position. The DC Voltage positions are on the left side of the range, marked with "⚡ V="; the AC Voltage positions are located on the right side of the range, marked with "〰️ V~".

    Note: If you are measuring an unknown voltage, set the range switch to the highest range and reduce it until a satisfactory reading is obtained.

  3. Turn the device or circuit's power on to measure the voltage value. It will appear on the digital display along with the voltage polarity.

DC CURRENT MEASUREMENT

  1. Connect the red test lead to “VΩmA” (center plug) and the black test lead to “COM" (right plug). For measurements between 200mA and 10A, connect the red test lead to “10A” (left plug).

    Note: For 10A measurements, only take readings for up to 10 seconds, and allow 15 minutes between tests. This prevents the device from overloading and overheating.

  2. Set the manual range switch to the desired DC Current position. The DC Current positions are located at the right side of the range, marked with a yellow "⚡ A=".

    Note: If you are measuring an unknown current, set the range switch to the highest range and reduce it until a satisfactory reading is obtained.

  3. Open the circuit being measured and connect the test leads in series with the load being measured. The results will appear on the digital display.
  4. The “10A" function is designed for intermittent use only. Maximum contact time of the test leads with the circuit is 10 seconds.

RESISTANCE MEASUREMENT

  1. Connect the red test lead to “VΩmA” (center plug) and the black test lead to “COM" (right plug).
  2. Set the manual range switch to the desired Resistance position. The Resistance positions are located at the bottom and bottom left of the range, marked with a yellow "Ω".

    Note: If you are measuring an unknown Resistance, set the range switch to the highest range and reduce it until a satisfactory reading is obtained.

  3. If the resistance being measured is connected to a circuit, turn off power and discharge all capacitors before measurement.
  4. Connect test leads to circuit being measured and the results will show on the digital display.

DIODE MEASUREMENT

  1. Connect the red test lead to “VΩmA” (center plug) and the black test lead to “COM” (right plug).
  2. Set the manual range switch to "➡️", located on the bottom right of the dial.
  3. Connect the red test lead to the anode of the diode to be measured and black test lead to cathode.
  4. The forward voltage drop in mV will be displayed. If the diode is reversed, an error will read "1" on the device screen.

AUDIBLE CONTINUITY TEST

  1. Connect the red test lead to “VΩmA” (center plug) and the black test lead to “COM” (right plug).
  2. Set the manual range switch to "?", located on the bottom right of the dial.
  3. Connect the test leads to two points on the circuit being tested. If the resistance is lower than 30Ω±20Ω, the buzzer will sound.

TEST SIGNAL USE

  1. Set the RANGE switch to "?" range.
  2. A test signal (50Hz) will appear between “VΩmA” and “COM” jacks; the output voltage is approximately 5V p-p with 50KΩ impedance.

BATTERY TEST

  1. Connect the black test lead to the "COM" jack and the red test lead to the "VΩmA" jack.
  2. According to the different type of the battery (1.5V, 9V, 12V) to be tested, set the range switch to the desired DC Voltage range.
  3. Connect the test leads to the battery to be tested. The red lead will touch the positive end of the battery, the black lead will touch the negative end.
  4. The DC Voltage measurement of the battery will be displayed.

BATTERY AND FUSE REPLACEMENT

If the low battery indicator "?" appears on the multimeter's screen, replace the battery immediately.

To replace the battery:

  1. Remove the screw at the top of the back of the multimeter. Remove the battery cover.
  2. Remove the old battery and replace it with a new 9V battery.
  3. Put the battery cover back on and put the screw securely back into place.

The fuse rarely needs to be replaced. If the fuse blows, it is almost always due to operator error. To test if the fuse needs to be replaced, use the following steps:

  1. Remove the test leads from the multimeter.
  2. Turn the rotary switch to the 200mA position.
  3. Use another multimeter to measure the resistance of the “VΩmA” terminal to the "COM" terminal.
    • If the fuse is still functional, the reading should display between 0 Ω and 10 Ω.
    • If the display indicates an overload, replace the fuse and test again.

To replace the old fuse:

  1. Remove the screw on the top of the multimeter's back. Then remove the battery from the battery terminal.
  2. Remove the two screws at the bottom of the multimeter's back.
  3. Remove the rubber bumper running along the outside of the multimeter, then separate the housing from the multimeter. Doing so should reveal the multimeter's circuit board.
  4. Find the fuse on the board. It will be located on the left side of the board. Remove the fuse and replace it with a new one rated 500mA/250V.
  5. Put the housing back together and put the rubber bumper back around the multimeter. Replace the battery and screws back into the meter.

ADDITIONAL MAINTENANCE

Beyond replacing the batteries and fuses, do not attempt to repair or service your multimeter unless you are qualified to do so and have the necessary calibration, performance testing and service instruments. The recommended calibration cycle is 12 months.

To clean the terminals:

  1. Turn the rotary dial to the OFF position and remove the test leads and battery.
  2. Shake out any dirt that may be in the terminals, soak a new swab with isopropyl alcohol and work around the inside of each input terminal.
  3. Use a new swab to apply a light coat of fine machine oil to the inside of each terminal.

INCLUDED ACCESSORIES

1 Year Warranty Limited Warranty From AstroAI

Each AstroAI Digital Multimeter will be free from defects in material and workmanship for its lifetime. This warranty does not cover fuses, disposable batteries and damage from neglect, misuse, contamination, alteration, accident, or abnormal conditions of operation or handling, including overvoltage failures caused by use outside the Multimeter's specified rating, or normal wear and tear of mechanical components. This warranty covers the original purchaser only and is not transferable.

If this product is defective, please contact AstroAI Customer Support at support@astroai.com.

PDF preview unavailable. Download the PDF instead.

81AaC7nXerL 福昕阅读器打印机版本8.3.1.0522

Related Documents

Preview AstroAI AM33D Digital Multimeter User Manual - Operation and Specifications
Comprehensive user manual for the AstroAI AM33D digital multimeter, detailing its features, safety precautions, measurement procedures for voltage, current, resistance, continuity, and diodes, along with maintenance and technical specifications.
Preview AstroAI 4000 Count Clamp Multimeter User Manual
Comprehensive user manual for the AstroAI 4000 Count Clamp Multimeter, covering safety instructions, operating procedures, specifications, and maintenance for accurate electrical measurements.
Preview AstroAI AM33B Digital Multimeter User Manual | Features & Specifications
Comprehensive user manual for the AstroAI AM33B digital multimeter. Learn about its features, safety precautions, operating instructions, and technical specifications for accurate electrical measurements.
Preview AstroAI CM2KOR Digital Clamp Meter User Manual
Comprehensive user manual for the AstroAI CM2KOR Digital Clamp Meter, covering introduction, warnings, included items, electrical symbols, meter diagram, button functions, auto power off, usage instructions, maintenance, battery replacement, specifications, disposal, and warranty.
Preview AstroAI DM130B Digital Multimeter User Manual
Comprehensive user guide for the AstroAI DM130B digital multimeter, detailing safety precautions, features, specifications, and operating instructions for accurate electrical measurements.
Preview AstroAI AM33D Digital Multimeter User Manual - 2000 Counts
Comprehensive user manual for the AstroAI AM33D Digital Multimeter (2000 Counts), providing detailed instructions, safety precautions, specifications, and maintenance guidance for electrical measurements including AC/DC voltage, current, resistance, continuity, and diode testing.
Preview AstroAI True RMS 6000 Count Digital Multimeter User Manual
User manual for the AstroAI True RMS 6000 Count Digital Multimeter (WH5000A), covering safety, operation, specifications, and maintenance for voltage, current, resistance, and more.
Preview AstroAI AM33B Digital Multimeter User Manual - Operation, Safety, and Specifications
User manual for the AstroAI AM33B 2000 Counts Digital Multimeter, detailing its features, operating instructions, safety precautions, maintenance, specifications, and warranty information.