EATON

OXALIS
Unit B, Sutton Parkway, Oddicroft Lane
Sutton in Ashfield NG17 5FB, United Kingdom

Document Identifier: IMI-UL-XF-XC-XP-XT Issue 4

2400 & 1400 Series (XP, XT, XC & XF) Flame Proof Camera Housings & Pan Tilt Units

Classification: Class I Div 1 Group B,C,D; Class II Div 1 Groups E,F,G; Class I Zone 1 IIB +Hydrogen

File No: E477542

Installation & Maintenance Instructions

This manual should be read before attempting to connect or operate the equipment. This manual should be kept for future reference.

This equipment shall be installed in accordance with the latest local/national codes of practice, and standards e.g.: UL 1203 Edn. 5, CSA22.2 No30-M1986 Edn1 reaffirmed 2012, CSA C22.2 No25-1966 reaffirmed 2014, CSA C22.2 No 60065-03 Edn. 1, UL60065 Edn. 7.

Whilst every effort has been made to ensure that all information in this document is correct at the time of publication, due to our policy of continuous improvement, the company reserves the right to change any information contained herein without notice.

Amendment Record

Issue Date Details of Amendment
1.0 First Issue
2.0 15/11/2016 Updated drawings. Added amendment record
3.0 24/02/2017 Label type update
4.0 01/05/2025 Added passwords for cameras

Contents Overview

This document is structured into the following sections:

Before Installation of the equipment ensure that:

  1. The installation instructions are read and understood.
  2. The correct tools are available for use when installing.

General

Important Safeguards and Warnings

This symbol ⚠️ indicates that there are important operating and maintenance instructions in the literature accompanying this unit. Read, Keep and Follow all instructions.

Prior to installation and use of this product, observe the following warnings:

  1. Installation and servicing should only be carried out by qualified service personnel and in accordance with all local/national codes of practice and standards e.g. UL1203 Edn.5, NFPA 70. No modification to the certified product is allowed.
  2. It is essential that provision is made for overload, short circuit and earth fault protection for this equipment. A double pole, mains rated, miniature circuit breaker rated to the max power consumption of the unit must be incorporated in the electrical installation of the power supply.
  3. A readily accessible disconnection device shall be incorporated in the electrical installation wiring to provide all-pole isolation of the supply to the equipment.
  4. Only use tools and replacement parts supplied or recommended by EATON. This unit does not contain any user serviceable parts.
  5. Care must be taken to ensure selection of suitable cables connecting to these units when installed in operating temperatures above +70°C.
  6. The equipment is designed to satisfy the requirements of UL60065 7th Edition 2013/07/24, CSA C22.2 No. 60065-03 2012/08/01 Safety Requirements ANNEX II of ATEX directive 94/9/EC.
  7. Be aware that aggressive substances may require extra protection of the equipment to maintain its integrity and explosion protection.
  8. The equipment may need additional means of protection if it is to be installed in locations where it may be exposed to excessive external stresses e.g. vibration, heat, impact and damage.
  9. Any repairs or replacement parts must be done by the manufacturer or a suitably qualified repair agent.
  10. Due to the large weight of the units, correct planning and equipment must be used when unpacking and installing. For P&T units, the correct lifting points must be adhered to (see section 3.1.2).
  11. Systems can be fitted with integral Fibre Optic transmitters, meaning the fibre optic cabling used has additional protective measures to ensure optical radiation is confined within the cabling, by the use of a robust conduit covering externally, and Kevlar braided cable inside the conduit and the enclosure. (NFPA 70 500.8 (F))
  12. When batteries are fitted to electronic equipment, they must be removed and are not to be replaced.
  13. After installation, operatives must adhere to the following warning on the units label: WARNING: DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. CLEAN WITH DAMP CLOTH.
  14. This symbol ⚡️ indicates that dangerous voltage constituting a risk of electric shock may be present within this unit.
  15. Illuminator "CAUTION Possibly hazardous optical radiation emitted from this product."

Description

The 2400 & 1400 series camera assemblies are developed to meet the rigorous requirements of Flame proof and dust-ignition-proof electrical equipment for installation and use in hazardous locations found in the onshore and offshore, oil & gas and petro-chemical installations. The units may also be used in marine and industrial hazardous environments.

The housing body and all external parts are manufactured entirely of AISI 316L stainless steel for low maintenance and protection from corrosion. Each of the main end covers is fixed to the body by five (5), M6 x 16-mm stainless steel hex cap screws. The cable entry cover of the XP and XT systems uses five M5 x 12-mm stainless steel hex cap screws or M110x1.5 screw on cover, all conforming to the requirements of UL 1203. The weatherproof seal of the union between the body and end covers is maintained by use of O-ring seals fitted in purpose-made grooves.

The camera housings feature an internal sliding camera mounting rail fitted with an internal heating element/de-mister, thermostatically controlled, to maintain operating temperature and ensure clarity of vision through the window, together with the optional integral window wiper mechanism.

The viewing window is made with toughened glass, or in the case of the Thermal Imager and Dual Imager versions, is made from Infra-red transparent material and is factory fitted with a mechanical window guard. The mechanical thermal window guard MUST not be removed.

There are four system types made from different combinations of the 2400 and 1400 series certified units:

The XF series fixed housings comprise a single tube section with either 3 cable entries in the rear cover or 1 in the side (model dependant). The XC series comprise a camera housing fixed to a P&T unit via an integrated tilt shaft; there are 3 cable entries in the rear cover of the housing or 1 into the blank side of the T unit (model dependant). The XP and XT units have dual cable entries into the fixed base section, preventing any trailing cables.

The 2400 & 1400 series housings and integrated pan/tilt units have been designed and certified to UL1203, with the following rating:

Note: T class and ambient temperature are dependent on the assembly configuration and maximum internal power dissipation. T* = T class, ## = Ambient Temperature range.

Description (continued)

The project requirements and unit certification label must be checked by the installer before installation to confirm that the product supplied is suitable for the intended installation zone and environment. Manufactured in accordance with UL 1203 Edn. 5, CSA22.2 No30-M1986 Edn1 reaffirmed 2012, CSA C22.2 No25-1966 reaffirmed 2014, CSA C22.2 No 60065-03 Edn. 1, UL60065 Edn. 7.

Versions

There are various camera configurations available within the range, including Day/Night cameras with optional wiper, integral washer or external washer, Thermal Imager, and Dual Camera Day/Night and Thermal units. The range also includes options for Standard Analogue Video and Data, HD IP cameras, Hybrid IP encoders, Digital Fibre optic converters, and Media converters. Due to the large variations of possible configurations, this manual only covers the standard installation of the units. For detailed connection and configuration of units, the installer should refer to individual project specific drawings and information. Various addendums are available that cover specific functions of electronics included within the camera assemblies.

Supplied Equipment

Contained in the package are the following items:

Recommended Tools

For installation and maintenance purposes, the following hand tools are recommended:

Recommended Spares

For maintenance purposes, the following spares are recommended:

Installation

In order to ensure proper wiring and system operation of all components, it is recommended that all units and associated control equipment be tested at your factory before field installation is attempted.

Unpacking and Handling

Unpacking

On receipt of the units, ensure that the cartons are undamaged and that the contents are all correct and complete. After unpacking, it is recommended that the packing materials are kept safe in case they are needed for returning the unit for repair or maintenance. The protective white film should be removed from sunshields prior to fitting.

Handling

Due to the large weights of the products, correct handling is of great importance. Lifting into position of P&T units should always be completed using suitable lifting equipment capable of supporting loads in excess of 65Kg. P&T systems should only be lifted using the T-section of the P&T, with equal support on both sides; the camera housing section of the unit must not be used for lifting. To avoid causing damage to the unit, do not rotate by hand. The units should not be handled with direct contact with ferrous metal equipment (see section 4.1 for details).

Mounting

To prevent injury, ensure the mounting surface and the selected mount can support four times the combined weight of the complete unit. Do not stand or place objects directly under an installed system. Due care must be taken to ensure sufficient clearance is allowed to permit full rotation of the unit with its associated equipment mounted, and that the moving unit cannot make contact with personnel. It is strongly suggested that where possible, Eaton range of mounting brackets are used.

Mounting the XP & XT Series (Horizontal or Inverted Only)

The XP and XT pan/tilt/housing assembly may be mounted onto various structures such as bulkheads, walls, or towers. It can be mounted in the Horizontal or inverted position, but the inverted option must be specified upon order. The complete assembly is mounted to the support structure via its base mount, which has 11mm clearance holes for four (4) No. M10 fixings (Fig. 1). The type and size of these fixings are to be supplied by the user/installer and must be suitable for the specific installation requirements. An alternative is to use the BPW6800 Wall mount bracket (Fig. 2).

Mounting the XC Series

The XC pan/tilt/housing assembly may be mounted onto various structures such as bulkheads, walls, or towers. It can be mounted in the inverted position, but this must be specified upon order. The complete assembly is mounted to the support structure via its Pan shaft, which has four (4) No. M8 Threaded fixing points on an industry standard spacing PCD of 101.6mm (4") (Fig. 3). The type and size of these fixings are to be supplied by the user/installer and must be suitable for the specific installation requirements. An alternative is to use the BFW5000 Wall mount bracket (Fig. 4) or one of the BFP**00 Column Spacers (Fig. 5).

Diagrams for Mounting

Fig. 1: XP26VW Example XP Series unit showing base mount fixing points. This diagram illustrates the dimensions and M10 fixing points for mounting the XP Series unit.

Fig. 2: BPW6800 Wall Bracket. This diagram shows the dimensions and mounting hole configuration for the BPW6800 wall bracket.

Fig. 3: XC40VW Example XC Series unit showing shaft mount fixing points. This diagram details the dimensions and M8 fixing points for mounting the XC Series unit.

Fig. 4: BFW5000 Wall Bracket. This diagram shows the dimensions and mounting hole configuration for the BFW5000 wall bracket.

Fig. 5: BFP0600/900/1200 Column Spacer. This diagram illustrates the dimensions and mounting hole patterns for column spacers, with height options H= 6, 9 or 12 inch.

Mounting the XF Series

The XF Series fixed housing assemblies may be mounted onto various structures such as bulkheads, walls, or towers. The units have a mounting plate on the bottom of the housing tube with four (4) No. M6 Threaded fixing points (Fig. 6). The type and size of these fixings are to be supplied by the user/installer and must be suitable for the specific installation requirements. To gain flexibility of the camera's view direction, one of the Eaton brackets is needed, these comprise of the BFPOOSW Swivel joint (Fig. 7), the BFW32SW (Fig. 8), or a combination of the BFW5000 and BFPOOSW (Figs. 4 & 7). Depending on housing length, some wall brackets do not allow the camera to view directly away from the wall and must be rotated or tilted to allow room for gland entry.

Diagrams for XF Mounting and Accessories

Fig. 6: XF60VN Example XF Series unit showing mount plate fixing points. This diagram illustrates the M6 fixing points and NPT entries for the XF Series unit.

Fig. 7: BFPOOSW Swivel Joint & Pole Top Adaptor. This diagram shows the dimensions and fixing points for the BFPOOSW swivel joint and pole top adaptor.

Fig. 8: BFW32SW Swivel Joint & Pole Top Adaptor. This diagram shows the dimensions and fixing points for the BFW32SW swivel joint and pole top adaptor.

Accessory Installation

Sunshield Installation

Sunshields are supplied uninstalled to prevent damage during shipping and unpacking. They are supplied with a protective white film that must be removed prior to installation. The correct sunshield fixings, for each model, are supplied with the camera system and should be positioned as detailed below. To mount the sunshields, first they must be positioned correctly and fixed with a Nylon spacer between the sunshield and the camera housing. The M6 A4 Button head screws supplied must have the red fibre washer fitted before fixing the sunshield (Fig. 9 & 10). Long and Medium sunshields have four equally sized fixings for each corner, but the short sunshield has two fixing types: one for the front with shorter screws and a nylon spacer at the rear (Fig. 10).

Diagrams for Sunshield Installation

Fig. 9: Mid and Long Housing Sunshield Installation. This diagram illustrates the attachment of mid and long sunshields to the camera housing using screws and spacers.

Fig. 10: Short Housing Sunshield Installation. This diagram shows the fixing points for the short housing sunshield, indicating front and rear fixing methods.

Washer Nozzle Installation

A continuous rotation P&T system, if supplied with an external washer unit, is supplied with a suitable washer nozzle and mounting bracket. These should be fitted during installation with the supplied fixing and positioned to allow cleaning fluid to reach the camera housing window when the wash command is sent. The supplied washer nozzle brackets are specific to housing type and are delivered pre-aligned for use (Fig. 11 & 12). When a wash command is sent to the camera, the unit will move to the factory set position to allow for the screen to be washed. For non-continuous rotation P&Ts and fixed housings, the washer nozzle is installed on the front window flange (Fig. 13).

Diagrams for Washer Nozzle Installation

Fig. 11: 260mm Housing washer nozzle. Shows the placement of the washer nozzle for a 260mm housing.

Fig. 12: 400mm Housing washer nozzle. Shows the placement of the washer nozzle for a 400mm housing.

Fig. 13: Non-continuous Rotation P&Ts and Fixed housings washer nozzle. Illustrates the washer nozzle installation on the front window flange for non-continuous rotation P&Ts and fixed housings.

Electrical Installation

Electrical installation and servicing should only be carried out by qualified skilled personnel. The class of wiring shall be marked adjacent to the mains terminals and in accordance with all local/national codes of practice and standards e.g. UL 1203 Edn. 5, CSA22.2 No30-M1986 reaffirmed 2014, CSA C22.2 No25-1966 reaffirmed 2014, CSA C22.2 No 60065-03 Edn. 1, UL60065 Edn. 7.

Due to the large variations of possible configurations, this manual only covers the standard installation of the units. For detailed connection and configuration of units, the installer should refer to individual project specific drawings and information.

Units can be supplied, as required, with either 24VAC, 110VAC~ or 230VAC~ Supply; all ±10%. The units should only be powered from the specified voltage; no allowance is made for varying voltage supply.

Warning: Irreparable damage to the unit will result from the application of incorrect Power Supply Voltage.

Electrical Installation XP & XT Integrated Pan, Tilt, housing assembly

  1. Always use colour-coded conductors or other identification of conductors for ease of wiring and identification of function at a later date.
  2. Keep a wiring diagram with the system for later use and reference.
  3. Provision is made for one or two cable entries, at the base mount of the pan tilt (Fig. 14A to 14E). To maintain the certification requirements of the unit, all cables/conduits must be fitted at the entry with certified Class / Div Flameproof, compound filled barrier glands, or conduit sealing fittings within 2" or 50mm of the enclosure.
  4. The cable entry to the unit is either two or one ½” NPT thread (model dependant), or 1½" NPT using a suitably certified reducer, dependent on what was specified at order.
  5. A minimum of 5 fully engaged threads must be maintained for all glands.
  6. All unused threaded openings shall be closed by suitably approved threaded plugs, recommended EBNV/7 approved.
  7. All glands/reducers must be ingress protected to IP67 or better, to maintain the weatherproof rating of the equipment.
  8. For maintenance purposes, consult separately supplied additional wiring drawings specific to the purchase order, for as-built wiring and connection details of the unit.
  9. The Dual entry option has an accessible input fuse (f1). Check that the input fuse matches the voltage requirement: 24VAC - 6.3A; ≥110 - 2A.

Diagrams for XP & XT Electrical Installation

Fig. 14: Gaining access to the XP and XT Base junction box (single entry design). Shows cable entry and provides a caution regarding snagging cables and removing the flange when energized.

Fig. 15: Gaining access to the XP and XT Base junction box (dual entry design). Illustrates loosening an M3 grub screw and accessing M5 button head screws.

Fig. 16, 17 & 18: Unscrew entry chamber lid. These diagrams show how the two M5 button head screws and threaded holes can be used to assist in rotating the chamber lid.

Fig. 19 & 20: Remove connection cover to reveal all connections. These diagrams show the process of accessing the internal connections.

XP & XT Common Connection Examples

Always refer to project specific drawings and information.

Fig. 21: Common connection PCB for single entry design. This diagram shows the terminal layout for power, RS485, and video signals on a single entry PCB.

Fig. 22: Common connection for Dual entry design. This diagram details the terminal connections for dual entry designs, covering Analogue, IP, and Fibre Optic models with pump output, including specific terminal assignments (sk1, sk2, sk3, sk5) and fuse details.

Caution: Should be taken when connecting the supply voltage, to ensure that it matches the marked value.

Electrical Installation XF & XC Series units

  1. Cable entry type to the housing is via 1 x ½"NPT entry at the side adaptor of the housing, or for some versions via the triple ¼"NPT cable entry end cover on the rear of the housing, solely for connection of power and signal wiring. No internal user wiring is allowed in this unit (Fig. 15, 16 & 17).
  2. Keep a wiring diagram with the system for later use and reference.
  3. For maintenance purposes, consult separately supplied additional wiring drawings specific to the purchase order, for as-built wiring and connection details of the unit.

Diagrams for XF & XC Electrical Installation

Fig. 23: Removing the Wiper Arm. This diagram shows how to remove the wiper arm by loosening an M4 cap head screw, advising to keep the wiper and nylon washer safe for refitting.

Fig. 24: Removing the Front Window flange. Illustrates removing the front window flange by unscrewing 5 x M6 screws and extracting the flange, followed by sliding out the camera mounting rail.

Fig. 25: Removing the rear flange. Shows removing the rear flange by unscrewing 5 x M6 screws and extracting the flange, followed by sliding out the camera mounting rail to reveal incoming cable connection terminals.

Fig. 26 & 27: Removing the connection cover to reveal all connections for high voltage options. These diagrams show the process of accessing connections for high voltage configurations.

XC & XF Common Connection Examples

Always refer to project specific drawings and information. Also refer to figure 22 for common input examples when the input connection PCB is installed.

230VAC MODEL WITH PUMP OUTPUT: Shows wiring for EARTH, 230VAC L, 230VAC N, NC, SWITCH L 24VAC PUMP SUPPLY, N 24VAC PUMP SUPPLY, DATA B, DATA A+, and VIDEO DIRECT TO CAMERA terminals.

24VAC MODEL WITH PUMP OUTPUT: Shows wiring for EARTH, 24VAC L, 24VAC N, NC, SWITCH L 24VAC PUMP SUPPLY, N 24VAC PUMP SUPPLY, DATA B, DATA A+, and VIDEO DIRECT TO CAMERA terminals.

24VAC MODEL NO PUMP OUTPUT: Shows wiring for EARTH, 24VAC L, 24VAC N, J2, J3, J1 (HEATER 220 10W), DATA B, DATA A+, and VIDEO DIRECT TO CAMERA terminals.

24VAC IP MODEL NO PUMP OUTPUT: Shows wiring for EARTH, 24VAC L, 24VAC N, J2, J3, J1 (HEATER 220 10W), and ETHERNET DIRECTLY TO CAMERA OR ENCODER VIA CAT5E, RJ45 terminals.

Maintenance

Recommended inspection interval: 6 Months.

Inspect the unit every six months to ensure trouble-free operation and extend product life. Due to the rugged construction of the unit, little or no maintenance should be required. However, when the unit is exposed to extreme weather conditions, the O-ring weather seals may need replacement approximately every five years.

Fixings and fastenings should be checked for tightness and integrity at regular intervals. All cable entries and cables should be checked for integrity at regular intervals. Extremely Harsh Environments may require more frequent inspection and maintenance checks.

At every inspection, carry out the following:

Please read and be familiar with the instructions before servicing the Pan/Tilt or housing.

Corrosion Protection

Although all external metal components are produced from 316L Stainless Steel, if the units are not correctly maintained, handled, and cleaned, there is the possibility of mild discolouration due to Oxidation. If ferrous metal equipment is used when handling the units, small ferrous deposits could be left on the stainless steel, or if ferrous metal particles come to rest upon the units from nearby works, this can cause accelerated corrosion of the ferrous deposits and discolour the units due to oxidation. In the event of ferrous deposits, the units should be cleaned immediately following EATON guidelines.

In atmospheres that are high in corrosive particles, the units should be cleaned every 3 to 4 months using only EATON recommended cleaning products and procedures (contact EATON for details). EATON takes no responsibility for oxidisation due to failure in correctly following cleaning procedures.

Labelling

The labels are made from stainless steel and affixed to the product using rivets. The contents of the label will be in ENGLISH.

The label shows:

Camera Housing label

The camera housing label displays manufacturer (EATON, OXALIS), part number, voltage, serial number, IP rating, area classification (Class I Div 1, Class II Div 1, Class 1 Zone 1), caution and warning statements in English and French, UL listing information (E477542), and manufacturer location.

Pan Tilt unit label

The Pan Tilt unit label displays manufacturer (EATON, OXALIS), part number, serial number, voltage, IP rating, area classification (Class I Div 1, Class II Div 1, Class 1 Zone 1), caution and warning statements in English and French, UL listing information (E477542), and manufacturer location.

Illuminator unit label

The Illuminator unit label displays manufacturer (EATON, OXALIS), part number, voltage, serial number, IP rating, area classification (Class I Div 1, Class II Div 1, Class 1 Zone 1), caution and warning statements in English and French, UL listing information (E477542), and manufacturer location.

Specifications, Technical data & Special conditions for safe use

Coding: Class I Div 1 Group B,C,D; Class II Div 1 Groups E,F,G; T135°C; IP67. T Class; ## = Ambient Temperature range.

Construction: Stainless Steel AISI 316L.

Ingress Protection rating: IP 67.

Max Weight:

Mounting:

Supply voltage: 24VAC, 50/60Hz or 100 to 230VAC~ with integral transformer.

Power consumption: Max 120 Watts depending on model.

Default IP addresses and passwords

Device IP Address Username/Password
Eaton Cameras 192.168.10.10 admin/Eaton123!
Hanwha Cameras 192.168.1.100 admin/XNZ-6320
Models: XP, XT, XC, XF, 1400 Series Flame Proof Camera Housings, 1400 Series, Flame Proof Camera Housings, Proof Camera Housings, Camera Housings

File Info : application/pdf, 20 Pages, 2.44MB

PDF preview unavailable. Download the PDF instead.

tm295-en-oxalis-xf-xc-xp-xt-ex-cameras-ul Microsoft Word 2010

Related Documents

Preview EATON 2400 & 1400 Series Flame Proof Camera Housings & Pan Tilt Units Installation & Maintenance Manual
Installation and maintenance guide for EATON's 2400/1400 Series Flame Proof Camera Housings and Pan Tilt Units (XP, XT, XC, XF). Covers safety, installation, maintenance, and IECEx/ATEX certifications for hazardous environments.
Preview Eaton XF, XP & XT Series Flame Proof Camera Housings & Pan Tilt Units Installation & Maintenance Manual
Comprehensive installation and maintenance manual for Eaton's XF, XP, and XT Series Flame Proof Camera Housings and Pan Tilt Units. Covers safety, installation, electrical, and maintenance procedures for hazardous environments.
Preview EATON XP & XF Flame Proof Smart IR Camera Housings & Pan Tilt Units: Installation & Maintenance Manual
Comprehensive installation and maintenance guide for EATON XP & XF series Flame Proof Smart IR Camera Housings and Pan Tilt Units, including ATEX and IECEx certification details, specifications, and safety procedures.
Preview EATON SP, ST, SC, SF Series Camera Housings & Pan Tilt Units Installation Instructions
Comprehensive installation and maintenance guide for EATON's SP, ST, SC, and SF series camera housings and pan tilt units. Covers safety, product details, mounting, electrical connections, maintenance, and technical specifications.
Preview Eaton CROUSE-HINDS Xenon Beacon XB15 & XB15M Technical Manual
Comprehensive technical manual for Eaton CROUSE-HINDS Xenon Beacon models XB15 and XB15M, covering installation, operation, maintenance, safety, and certification details for hazardous environments.
Preview Eaton V2PCT20 Replacement Photocell: Specifications and Certifications
Detailed product specifications, certifications, and resources for the Eaton V2PCT20 replacement photocell. Includes technical data, area classification, and compatibility information for industrial lighting.
Preview Eaton VacClad-W 5/15 kV Metal-Clad Switchgear: Installation, Operation, and Maintenance Manual
Comprehensive guide for the installation, operation, and maintenance of Eaton's 5/15 kV VacClad-W metal-clad switchgear indoor housings. Covers safety, procedures, features, testing, and maintenance schedules.
Preview Eaton B-Line Series Cable Tray Systems: Product Overview and Specifications
Comprehensive guide to Eaton's B-Line series cable trays, covering materials (aluminum, steel, stainless steel), finishes (zinc coatings, paint), corrosion resistance, and fittings. Includes detailed specifications and part numbering systems for industrial and commercial applications.