Dometic Penguin II Low Profile Air Conditioner/Heat Pump
The nature of climate.™
Introduction
Continuous product improvement! That best describes what Dometic engineers have done with the Penguin II. RVers will appreciate new features and outstanding performance as only Dometic can deliver. The Penguin II creates the perfect comfort zone.
- Low profile, under 10-inches high – the lowest in the industry
- Sleek, contemporary shroud design reduces drag for improved mileage
- R410A refrigerant is eco-friendly and releases heat more efficiently
- Redesigned base pan with ribs is engineered for strength and durability
- Air conditioning or heat pump models available
- Perfect for ducted or non-ducted cooling systems
- Perfectly matched for Dometic's exclusive QuietZone system
Design and Performance
The Penguin II has a sleek, futuristic look with incredible performance. Choose an air conditioner or heat pump for comfort and durability.
Full automation means freedom from worry. The heat pump is thermostatically controlled (CCCII Thermostat) and automatically activates the LP gas furnace at 30 degrees Fahrenheit for continuous relaxation.
Dometic Penguin II - Low Profile Air Conditioner Components
Dometic does cool with style. Our air conditioners are versatile performers with a low profile. Fully automated and worry free.
Air Distribution Box
- Five multi-directional air slots
- Ratcheting side vents
- Washable Hepa-style filters
Single Zone LCD Thermostat
- Simple, three-button operation
- Easy control for cool/furnace, heat pump or heat strips
- Low profile
- Manual or automatic control
- Large display screen
Comfort Control Center II
- Fully digital operation
- Large, low profile SMX bluelight display
- Industry first, real time-of-day, area independent programming
- Easily controls rooftop AC, heat pump, furnace, heat strip, Aquaheat floor system or Automatic Generator Start (AGS)
Return Air Grill
- Washable filter
- Quick cool air discharge
- Low profile
The Penguin Advantage: Engineering and Innovation
Beautiful on the outside – genius on the inside. What you don't see makes the Penguin the industry leader in low profile RV air conditioners.
Internal Component Benefits
- Copper Tubing: Features lower heat factor for superior heating and cooling.
- Rubber Damper: Shown positioned to reduce vibration and noise while adding support to copper tubing.
- Ribbed Fan Housing: Designed to add strength for reduced vibration.
- Dynamic Shroud Design: Reduces airflow resistance while providing maximum cooling.
- Radius Corners: Create strength, quiet operation, and smooth air flow.
- Convex Basepan Pattern: Distributes the weight of the AC unit for stability.
- Foam Seals: Prevent unwanted heat transfer and loss of performance.
- Unique Foam Collar: Located around the motor shaft to prevent noise transfer during operation.
- Insulated Evaporator Housing: Prevents solar heat build-up.
- Close Tolerances: Between the base pan and shroud to reduce vibration and noise.
- Raised Ring: Around screw and drain holes to prevent moisture from entering the RV interior.
- High Density Foam Blocks: Positioned to prevent vibration from being felt inside the RV.
Technical Specifications
Dometic Penguin II – Low Profile Air Conditioner
Features | 60312C | 60315C | 641935C | 641915C | 641815C | 641835C | 641816C | 641916C |
---|---|---|---|---|---|---|---|---|
Nominal capacity, BTU/hr | 11,000 | 13,500 | 13,500 | 13,500 | 13,500 | 13,500 | High Capacity | High Capacity |
Installation type | Non-ducted | Non-ducted | Non-ducted | Non-ducted | Non-ducted or Ducted | Non-ducted or Ducted | Non-ducted or Ducted | Non-ducted or Ducted |
Electrical rating | 120V AC, 60 Hz, 1Ph | |||||||
Compressor-rated load amps | 10.5 | 12.7 | 12.7 | 12.7 | 12.7 | 13.4 | 13.4 | |
Fan motor-rated load amps | 2.6 | 2.6 | 2.6 | 2.6 | 2.6 | 2.6 | 2.6 | |
Compressor-locked rotor amps | 53 | 63 | 63 | 63 | 63 | 63 | 63 | |
Fan motor-locked rotor amps | 8.5 | 8.5 | 8.5 | 8.5 | 8.5 | 8.5 | 8.5 | |
SCFM, high-speed max./min. | 320/250 | 320/250 | 320/250 | 320/250 | 320/250 | 310/230 | 310/230 | |
Heater amps/watts @ 120VAC | - | 13.7/1,530 | 13.7/1,530 | - | - | - | - | - |
Refrigerant 410A (oz.) | 19.0 | 18.0 | 18.0 | 18.0 | 18.0 | 25.0 | 25.0 | |
Minimum wire size | 12 AWG copper up to 24 feet. For distances over 24 feet consult the National Electrical Code. | |||||||
AC circuit protection | (User Supplied) 20 amp time delay fuse or 20 HCAR circuit breaker | |||||||
DC circuit protection | (User Supplied) Installation must comply with national, state, provincial and/or local electrical codes | |||||||
Installed weight, lbs. | 99 | 99 | 99 | 99 | 99 | 99 | 110 | 110 |
Minimum generator size - 1 unit | 2.5 KW | 3.5 KW | 3.5 KW | 3.5 KW | 3.5 KW | 3.5 KW | 3.5 KW | 3.5 KW |
Minimum generator size - 2 units | 4.0 KW | 5.0 KW | 5.0 KW | 5.0 KW | 5.0 KW | 5.0 KW | 5.0 KW | 5.0 KW |
Thermostat/Control options | ADB or Control Kit | ADB or Control Kit | Single zone LCD | Multi zone CCC 2 | Multi zone CCC 2 | Multi zone CCC 2 | Single zone LCD |
Dometic Penguin II – Low Profile Heat Pump
Features | 650015C | 651815C | 651816C | 651916 |
---|---|---|---|---|
Nominal capacity, BTU/hr. | 13,500 | 13,500 | High Capacity | High Capacity |
Installation type | Non-ducted | Non-ducted or Ducted | Non-ducted or Ducted | Non-ducted or Ducted |
Electrical rating | 120VAC, 60 Hz, 1Ph | |||
Compressor-rated load amps | 13.1 | 13.1 | 13.4 | 13.4 |
Fan motor-rated load amps | 2.6 | 2.6 | 2.6 | 2.6 |
Compressor-locked rotor amps | 63 | 63 | 63 | 63 |
Fan motor-locked rotor amps | 8.5 | 8.5 | 8.5 | 8.5 |
SCFM, high-speed max./min. | 320/250 | 320/250 | 310/230 | 310/230 |
Refrigerant 410A (oz.) | 24 | 24 | 27 | 27 |
Minimum wire size | 2 AWG copper up to 24 feet. For distances over 24 feet consult the National Electrical Code. | |||
AC circuit protection | (User Supplied) 20 amp time delay fuse or 20 HCAR circuit breaker | |||
DC circuit protection | (User Supplied) Installation must comply with national, state, provincial and/or local electrical codes | |||
Installed weight, lbs. | 99 | 99 | 99 | 99 |
Minimum generator size - 1 unit | 3.5 KW | 3.5 KW | 3.5 KW | 3.5 KW |
Minimum generator size - 2 units | 5.0 KW | 5.0 KW | 5.0 KW | 5.0 KW |
Thermostat/Control options | ADB | Multi zone CCCII | Multi zone | Single Zone LCD |
Warranty and Contact
Outstanding Warranty
Dometic's 2-Year Protection Plus warranty.
For more information visit www.Dometic.com/USA
Dometic reserves the right to make improvements or modifications without notice.
Printed on recycled paper with 25% post consumer content with environmentally safe ink. Printed in U.S.A. ©2011 Dometic Corporation OS2136 DRV-729/TM/11-11/1.5M