BEGA B28RFTS1 Round Fixed Tapered Aluminum Pole
Product Specifications
Application
A round, tapered, aluminum pole with a fixed base. Useful for mounting pole-top luminaires, floodlights, banners, or other accessories. Consultation with a licensed structural engineer is recommended when specifying. Poles must be unwrapped upon delivery and should not remain in their packaging. Poles specified without pole tops require internal approval before release.
Materials & Specifications
- Extruded aluminum pole shaft
- Covered handhole with hardware and grounding provisions
- Factory-installed vibration dampener
- 3" welded tenon
- A356 aluminum alloy anchor base, heat-treated to T6 temper
- Anchor bolts conform to ASTM F1554 Grade 55 with L bend on one end and galvanized minimum 12" on threaded end
- Anchor bolts include (2) hex nuts and (2) flat washers
- Aluminum nut covers
Wall thickness: 0.156"
Structural weight: 92.0 lbs
Maximum Luminaire Weight: 62 lbs
Finish
All BEGA standard finishes are matte, textured powder coat with a minimum 3 mil thickness. The BEGA Unidure® finish offers superior fade protection in Black, Bronze, and Silver. BEGA standard White is a super durable polyester powder. RAL, custom, and premium colors are optionally available in polyester powder and/or liquid paint.
Available Colors:
- Black (BLK)
- Silver (SLV)
- Bronze (BRZ)
- White (WHT)
- RAL: (Custom RAL colors)
- CUS: (Custom finishes)
Product Details
Type: BEGA Pole
Location: [Not Specified]
Quote or Sales Order: [Not Specified]
Date: [Not Specified]
Specifier: [Not Specified]
Representative: [Not Specified]
BEGA Luminaire: [Not Specified]
Total Mounted EPA: [Not Specified]
Total Mounted Weight: [Not Specified]
Available Options
- CUS: Custom finish
- GFCI: GFCI with standard cover (Orientation: 180°; Height: 36" A.F.G)
- MGU: Marine grade undercoat
- RAL: RAL finish
Dimensions
Textual Description of Diagram: A diagram illustrates the tapered profile of the aluminum pole. Dimension A represents the top shaft diameter. Dimension B indicates the pole length. Dimensions C and D denote intermediate diameters along the pole shaft. Dimension E signifies the base diameter.
Model | A | B* | C | D | E |
---|---|---|---|---|---|
B28RFTS1 | 3" | 28' | 11¼" | 7" | 4" |
*Height is rounded to the nearest foot; for precise measurements, refer to the submittal drawing.
Pole Wind Load Rating
**Data assumes grade level installation and a maximum luminaire weight of 62 lbs.
MPH | 70 | 80 | 90 | 100 | 110 |
---|---|---|---|---|---|
EPA** | 10.5 | 7.1 | 5.0 | 3.7 | 2.8 |
Available Accessories
- B19606: Round base cover
- B19607: Square base cover
Refer to the individual accessory spec sheet for detailed information.
Included (Available for Pre-shipment)
- B28RFTS1-AB Anchorage kit
Page 2: Accessories, Options, and Modifications
Accessory Visuals
Textual Description of Diagram: Visual representations show various accessory types. One section displays "Nut Covers". Another section illustrates "Round (optional)" and "Square (optional)" pole bases, each associated with specific part numbers (e.g., B19602, B19609, B19612 for round; B19604, B19606, B19610, B19603, B19608, B19613, B19605, B19607, B19611 for square).
Location Diagram
Textual Description of Diagram: A circular diagram indicates pole orientation. Key points are marked at 0°, 90°, 180°, and 270°. The "Handhole" is positioned at the 0° mark.
Options
Power Receptacle
GFCI covers are designed for portable tools or other portable equipment connected to the outlet when attended. The outlet is wet location listed when the cover is closed.
- GFCI at default location: Orientation: 180°; Height: 36" A.F.G.
- In-user cover
Modifications
Any changes or additions to BEGA North America's standard pole offerings not listed as accessories or options are considered modifications. All modification requests must be quoted and approved by BEGA North America prior to order placement.
Modified Pole Height:
[Not Specified]
Power Receptacle - Nonstandard Location
- GFCI at custom location
- Orientation: [Not Specified]
- Height (minimum 18" A.F.G): [Not Specified]
- In-user cover
Handhole
- Handhole must be positioned 18" from the GFCI
- Unless otherwise specified, the handhole will be at the default location
- Default Orientation: 0°; Default Height: 18" A.F.G
- Handhole at custom location
- Orientation: [Not Specified]
- Height: [Not Specified]
Additional Information
Still not finding what you need? Additional modifications may be available. Please contact your local BEGA representative to learn more about BEGA's modification capabilities.
Note: Accessories, options, and modifications may require additional lead-time and incur increased costs. All details must be quoted and approved by BEGA North America prior to order placement.
Disclaimer
BEGA North America warrants the specific anchor bolts and pole combination as indicated on the submittal sheet. Structural changes to the pole requested by the customer, including changes to pole length, may affect the compatibility of the anchor bolts and corresponding poles. BEGA North America is not liable for incompatibility of anchor bolts and poles resulting from such structural changes without review by the BEGA North America engineering department. This includes, but is not limited to, labor charges, replacement material costs, and shipping. For safety reasons, do not mount more than 50 lbs. to hinged poles and more than 62 lbs. to fixed poles. Pole capacities are based on AASHTO 2013 (LTS-6) provisions and assume a maximum vertical eccentricity of 2'-0" above the pole top. Adequate drainage must be provided in the concrete foundation or grout. Do not seal the base of the pole. Due to structural reasons, do not install the pole without a fixture or other appropriate weight on top. BEGA North America is not responsible for ensuring local code compliance of anchor bolts, poles, or pole tops, including wind speed or ice loading calculations.