Resideo Residential Combustion Gas Controls Quick Reference Guide

Resideo AquaReset™

The Resideo AquaReset™ system offers enhanced control for residential heating systems. Below is a product selection guide:

Product Name Part Number Includes Typical Applications
Resideo R7284 Oil Primary Control W8735ER1000 Module and Wireless Sensor Upsell as an add-on when installing a new boiler that comes from the OEM with an enabled L7224U or L7248 Aquastat.
Resideo Wireless AquaReset Kit W8735Y1000 Module and Wireless Sensor Upsell as an add-on when installing a new boiler that comes from the OEM with an enabled L7224U or L7248 Aquastat.
Resideo AquaReset Kit W8735S1000 AquaReset Module and Wired Sensor Indirect domestic hot water tank applications may require additional kit W8735S1008.
Resideo Domestic Hot Water Kit W8735S1008 DHW Module and Wired Pipe Temperature Sensor Required to enable domestic hot water override on some applications. 1

1 Required for use when domestic hot water override is needed and a Z terminal is not present on the Aquastat.

See technical literature 67-7286 for complete application details.

R7284U Universal Electronic Oil Primary Selection Guide

This guide provides selection details for the R7284U Universal Electronic Oil Primary control.

Ignition Type R7284 Direct Service Part Universal Service Part Lockout Time (sec.) Valve On Delay (sec.) Blower Off Delay (min.) Alarm Contacts* w/ LED Indicator Resideo Beckett Carlin Cross-Reference
Interrupted R7284U1004 R7184U1004 15 0/15 0/2/4/6 Yes Yes 7505P125M R7184A1026, R7184A1075, R7184A1000 50200-02S, 602000-02S, 6020002S015120, 6020002S030015, 6020002S030015, 6020002S030030, 6020002S030120, 6020002S030300, 6020002S030010
Interrupted R7284B1024 R7184B1024 15 15 0.25 Yes Yes 7505B1500 R7184B1024, R7184B1032, R7184B1016 40200-02S
Interrupted R7284U1004 R7184U1012 30 0/15 0/2/4/6 Yes No 7505P1515 R7184P1080, R7184P1098
Interrupted R7284U1004 R7184U1020 45 0/15 0/2/4/6 Yes No R7184A1018, R7184A1034 42230-02S
Intermittent R7284U1004 R7184U1004 15 Yes Yes Yes 7505A0000 R8184G1294, R8184G1302, R818464066, R8184G4074, R8184G4033, R8184G4090, R8184G1427, R8184G4058
Intermittent R7284U1004 R7184U1012 30 Yes Yes No R8184G1393, R8184G1302, R8184G4074, R8184G4033
Intermittent R7284U1004 R7184U1020 45 Yes Yes No R8184G1286, R8184G1427, R8184G1458, R8184G4009, R184G4025, R8184G4082, R8184G4108 48245-S
Intermittent R8184M1051 45 Yes Yes Yes R8184M1051

* R7284 models require an alarm contact accessory module.

L7224U Universal Electronic Aquastat® Selection Guide

This guide provides selection details for the L7224U Universal Electronic Aquastat®.

Specifications

Fuel Low Limit High Limit Product Number Operating Range, Low Limit Differential Temperature, Low Limit Operating Range, High Limit Differential Temperature, High Limit
Gas 110° to 220° F 130° to 240° F L7224U1002 110° to 220° F 10° to 25° F adj. 130° to 240° F 5° to 20° F adj.
Oil 110° to 220° F 130° to 240° F L7224U1002 110° to 220° F 10° to 25° F adj. 130° to 240° F 5° to 20° F adj.

Replacement Sensor

Part Number Length (in.)
50001464-001 12
50001464-004 36
50001464-005 48

Cross-Reference Guide

Product Number Replaces Mounting Orientation Features and Functions Switching Action Anticipator Setting Mounting White-Rodgers
L7224U1002 L7224U Universal Electronic Aquastat® Well Mounted - Horizontal 3 SPST: High and Low Limit, Circulator 0.1 A 669-640, 669-670
Well Mounted - Horizontal 669-440, 669-445, 669-470, 669-540
Well Mounted - Horizontal 668-601, 668-670
Well Mounted - Vertical 668-501
Flush Mounted - Vertical 668-401, 668-0415, 668-430, 668-515
Well Mounted - Vertical 668-430
Well Mounted - Vertical 668-441, 668-451, 668-454
L7124A1017, L7124A1025, L7224A1008, L7224A1016, L8124A1007, L8124A1015, L8124A1049, L8124A1098, L8124A1106, L8124A1114, L8124A1122, L8124A1130, L8124A1155 Well Mounted - Vertical High Limit: 130° to 240° F
High Limit Difference: 10° F
Low Limit: 110° to 220° F
Low Limit Difference: 10° to 25° F
L7124C1005, L7224C1004, L8124C1003, L8124C1011, L8124C1029, L8124C1094, L8124C1102 Well Mounted - Vertical High Limit: 180° to 220° F
High Limit Difference: 15° F
Low Limit: 110° to 220° F
Low Limit Difference: 10° to 25° F
L7148A1019, L7248C1014, L8148A1009, L8148A1025, L8148A1033, L8148A1058, L8148A1066, L8148A1074, L8148A1082, L8148A1090, L8148A1116, L8148A1157 Well Mounted - Vertical High Limit: 140° to 240° F
High Limit Difference: 10° F
Low Limit: 110° to 220° F
Low Limit Difference: 10° to 25° F
L7148A1035, L7248C1006, L8148A1017, L8148A1065, L8148A1124, L8148A1140 Flush Mounted - Vertical High Limit: 180° to 220° F
High Limit Difference: 15° F
Low Limit: 110° to 220° F
Low Limit Difference: 10° to 25° F
L7148A1050, L7248A1000, L8148A1157 Well Mounted - Vertical High Limit: 140° to 240° F
High Limit Difference: 10° F
Low Limit: 110° to 220° F
Low Limit Difference: 10° to 25° F
L7248C1022 Well Mounted - Vertical High Limit: 180° to 220° F
High Limit Difference: 15° F
Low Limit: 110° to 220° F
Low Limit Difference: 10° to 25° F

CAD Cells

Product Number CAD Cells (1) Lead Length (in.) Wire Termination Mounting Bracket Includes Tradeline Value Replaces White-Rodgers Westwood
C554A1315 120320 30 Stripped Type B Tradeline C554A1307, C554A1315, C554A1398, C554A1133, C554A1174, C554A1372, C554C1570, C554A1216, C554A1927, C554A1794 956-154 TMK-60
C554A1463 130367 60 2 Flag 1/4" QC Type R A, B, E, J and P Mounting Brackets and Fuel Line Adaptor Super Tradeline C554A1307, C554A1927 956-11, 956-154 TMK-60
C554A1794 130367 60 Stripped Type R E Mounting Bracket and Fuel Line Adaptor Tradeline

Notes:
*120320 replacement CAD cell 7.5 MA minimum sensitivity at 2' candles.
*130367 high-sensitivity CAD cell 12 MA minimum sensitivity at 2' candles.
1 48 inch lead wire

Models: R7284U, Multisystem Electronic Oil Primary

File Info : application/pdf, 2 Pages, 707.06KB

PDF preview unavailable. Download the PDF instead.

63-9581O

References

Adobe PDF Library 15.0 Adobe InDesign 15.0 (Macintosh)

Related Documents

Preview Resideo L7224 Series Oil Electronic Aquastat Controller Guide
A technician's quick reference guide for the Resideo L7224 Series Oil Electronic Aquastat Controller, covering installation, operation, and troubleshooting.
Preview Resideo R8182D,E,F,H,J Combination Protectorelay™ Primary Control and Aquastat® Controller Installation and Operation
This document provides installation and operation instructions for the Resideo R8182 series combination Protectorelay™ primary control and Aquastat® controller. It details the product's application in oil-fired, hydronic heating systems, model specifications, mounting, wiring, operational modes, and startup procedures.
Preview V8205, VR8205 Direct Ignition Combination Gas Controls Installation Guide
Comprehensive installation instructions for Resideo's V8205 and VR8205 Direct Ignition Combination Gas Controls, detailing application, safety precautions, conversion procedures, installation steps, wiring, startup, and troubleshooting.
Preview ST9120U Universal Electronic Fan Timers Installation Guide
Detailed installation and wiring instructions for the Resideo ST9120U Universal Electronic Fan Timers, covering application, specifications, and troubleshooting for HVAC systems.
Preview Resideo V400 & V800 Combination Gas Controls Installation Guide
Comprehensive installation and operation manual for Resideo V400 and V800 Combination Gas Controls, detailing application, installation, wiring, safety checks, and troubleshooting for gas-fired appliances.
Preview Resideo L6006A Aquastat Controller Installation and Operation Guide
Comprehensive guide for installing and operating the Resideo L6006A Aquastat Controller, detailing its application, electrical ratings, installation procedures, wiring diagrams, operation, adjustment, and checkout.
Preview Resideo VS820 and VS821 Millivoltage Combination Gas Controls Installation Guide
This document provides detailed installation, operation, and safety instructions for the Resideo VS820 and VS821 millivoltage combination gas controls. It covers application, installation procedures, wiring, startup, checkout, and troubleshooting for these gas controls used in gas-fired appliances with 750 mV self-powered control systems.
Preview Resideo S8610U Universal Intermittent Pilot Gas Ignition Control Quick Reference Guide
A technician's quick reference guide for the Resideo S8610U Universal Intermittent Pilot Gas Ignition Control, covering wiring, settings, adjustments, and troubleshooting.