Exhibit N: User Manual

FCC ID: CGGAA2

Sentrol RCR

Range-Controlled Radar Detector

Model: RCR-50

Installation Instructions

Description

The RCR detector combines range-controlled radar (RCR) technology with a passive infrared (PIR) system to increase false alarm immunity by allowing it to sense human-sized objects within a specified range. Both the RCR and PIR systems must be triggered to set off an alarm, unless in radar only mode.

The detector is designed to use a 12VDC power supply provided by a UL Listed alarm control panel.

Features

  • High-security mode: Internal jumper allows you to disable the PIR, and use the radar only mode to detect intruders faster. This mode can be used for covert installations (mounted behind ceiling panels or walls).
  • Selectable range up to 50 feet (15.2m): Internal jumper allows radar range selection to optimize coverage.
  • LED indicator: A multi-color LED provides detector status.
  • Tamper switch: Activated when the pins on the circuit board are removed from the terminal sockets on the base.

Coverage Patterns

Figure 1 illustrates the coverage patterns for the detector. It shows polar coordinate diagrams representing the detection areas. The top view displays a circular pattern for radar and a fan-shaped pattern for PIR. The side view shows the vertical detection angle. Labels indicate "Radar Viewing Area" and "PIR Viewing Area" at various distances (e.g., 20 ft, 30 ft, 40 ft, 50 ft).

Parts

The following parts are included with the detector:

  • RCR detector
  • 1 screw to join the case halves
  • 3 factory-installed jumpers

Selecting a Location for the Detector

The detector can be mounted in a corner or on a flat wall. Use the following guidelines to determine the best location to install the detector:

  • Mount the detector so the expected movement of an intruder is across the detection pattern. See Figure 1.
  • Mount the detector on a stable surface 7 to 9 feet (2.1 to 2.7m) high.
  • DO NOT mount the detector within 2 feet (0.6m) of metallic objects or within 5 feet (1.5m) of fluorescent lights.
  • DO NOT place objects in front of the detector that may prevent a clear line of sight. (Not applicable in radar only mode.)
  • Avoid locations that expose the detector to possible false alarm sources such as:
    • Moving or vibrating objects (fans, pulleys, conveyor belts)
    • Electronic fields (electric motors, high voltage equipment)
    • Water spray or corrosive environments
    • Heat sources in the field of view (heaters, radiators)
    • Windows in the field of view
    • Strong air drafts on the detector (fans, air conditioners)
  • When installing multiple detectors:
    • DO NOT mount detectors facing each other.
    • Mount them at least 20 feet (6.1m) apart.
    • Use shorter range settings to avoid overlapping radar coverage.

Mounting detectors back to back is not recommended, but if an application requires such mounting, use the 20-foot (6.1m) range and walk test the installation to ensure proper operation.

Installing the Detector

All wiring must conform to the National Electric Code (NEC) and/or local codes having jurisdiction.

Important: DO NOT use this device for safety interlock applications.

To install the detector:

  1. Run the security system wiring to the detector location.
  2. To remove the front cover/electronic module, remove the nameplate and loosen the screw if necessary. To remove the nameplate, insert a small screwdriver into one of the nameplate side slots and gently push in and pry up with the screwdriver. Then press down on the top of the front cover with one hand, while holding the sides at the top of the back cover and squeezing in and pulling back with the other hand.
  3. CAUTION: You must be free of all static electricity before handling sensor circuit boards. Touch a grounded, bare metal surface before touching circuit boards or wear a grounding strap.
  4. If necessary, set the jumpers on the circuit board. See Setting the Jumpers.
  5. Remove the appropriate wiring and mounting knockouts from the back cover. The detector can be mounted on a flat wall or in a corner. See Figure 3.
  6. Pull the wires through the knockout holes and use screws to attach the base to the wall. Use screw anchors if necessary.
  7. Strip 1/4 inch (6.4mm) of insulation from each wire.
  8. Run each wire through the strain relief and under the appropriate screw terminals on the base and tighten the screws. See Figure 3.
  9. Line up the tabs on the bottom of the cover/electronic module with the corresponding tabs on bottom of the base and snap the cover/electronic module firmly down onto the base.
  10. Tighten the screw and replace the nameplate. See Figure 2.
  11. Apply power. The green LED should light for approximately 25 seconds and then go out.
  12. Walk test the coverage pattern as follows:
    • Walk throughout the intended coverage area.
    • Verify the detector alarms. See Understanding the LED.

Note: Most units walk test more accurately if the person testing waits 10 seconds between tripping the unit and walking again. This allows the detector to stabilize between trips.

Figure 3 shows the detector base, illustrating terminal sockets (SPR, TMPR, TMPR, NO, COM, NC, +12V, GND), knockouts for wiring (wiring knockout, flat-wall mount knockout, corner-mount knockouts), and a strain relief.

Figure 4 shows the main circuit board with jumpers labeled J2 (Range), J3 (LED Disable), and J4 (PIR). It indicates jumper positions for different settings.

Setting the Jumpers

The detector provides jumpers to select the detection range and PIR and LED operation. See Figure 4.

J2 Range

Use the jumper to cover the center pin and the pin indicating the desired range. No jumper = 50 feet (15.2m) and under.

50 feet (15.2m) and under (factory default): No jumper on J2.

40 feet (12.2m) and under: Jumper connects pins 1 and 2 on J2.

30 feet (9.1m) and under: Jumper connects pins 2 and 3 on J2.

20 feet (6.1m) and under: Jumper connects pins 3 and 4 on J2.

Note: You need to set J2 as close to the intended coverage range as possible. Overshooting the coverage area may cause false alarms.

J3 LED

  • ON = LED enabled (factory default)
  • OFF = LED disabled

J4 PIR

  • ON = Radar only enabled
  • OFF = PIR and Radar enabled (factory default)

SB01 Swivel-Mount Bracket

For ceiling-mount applications that require 90 degree coverage, an optional swivel-mount bracket (SB01) is available from GE Interlogix. See Figure 5.

Figure 5 shows the SB01 Swivel-Mount Bracket, designed for ceiling installations to achieve 90-degree coverage.

Maintaining the Detector

When installed and used properly, the detector provides years of service with minimal maintenance. You should walk test the detector annually to ensure proper operation.

When the cover is removed, power is interrupted to the sensor. Once the cover has been replaced, the green LED will illuminate for 25 seconds while the sensor warms up. After the green LED goes off, wait one minute and walk test the sensor.

Understanding the LED

The multi-color LED located on the bottom of the detector indicates the status of the unit as described in the following table.

LEDStatus
RedPIR and Radar detection. The detector is in alarm and the relay has switched.
GreenPIR detection only (no alarm).
YellowRadar detection only (no alarm).

In Radar only mode:

LEDStatus
RedRadar detection.

Specifications

Input voltage8.5 to 18VDC (UL: 10 to 16VDC)
Typical current20mA
Maximum current27mA
Electrical configurationForm C
Relay rating28VDC, 100mA max.
Tamper100ma, 40VDC
Detection range50' (15.2m) x 90°
Target velocity0.5 ft/sec to 5 ft/sec
Alarm duration5 sec
Mounting height7' to 9' (2.1m to 2.7m)
Operating temperature32° F to 122° F (0° C to 50° C)
Relative humidity5 to 93% non-condensing
Dimensions:2.8" (7.1cm) W
5.1" (13cm) H
2.3" (5.7cm) D
Weight6 oz (170g)
Colorwhite
Field wiring size12-24 AWG
Microwave frequency5.8GHz
ListingC-UL US

FCC Compliance

This device complies with Part 15 of the FCC rules. Operation is subject to the following three conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.
  3. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

FCC ID: CGGAA2

Product Ordering

Model NumberDescription
RCR-50Range-controlled radar, passive infrared detector with form C relay, stealth mode, tamper contacts, 50 foot (15.2m) maximum range
SB01Swivel-mount bracket

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=246884 Acrobat Distiller 5.0 (Windows)

Related Documents

Preview Sentrol RCR Range-Controlled Radar Detector Installation and User Manual
Comprehensive installation and user guide for the Sentrol RCR detector, featuring range-controlled radar (RCR) and passive infrared (PIR) technology for enhanced false alarm immunity. Includes setup, maintenance, specifications, and FCC compliance information.
Preview Sentrol Advisor X DV1201/DV1221 Structural Vibration Detection System Installation Guide
Installation instructions and technical data for the Sentrol Advisor X Structural Vibration Detection System, models DV1201 and DV1221, designed for detecting break-in attempts on vaults, safes, night deposit units, and other secure physical areas.
Preview Sentrol Advisor X DV1200 Series Structural Vibration Detection System Installation Guide
Comprehensive installation instructions for the Sentrol Advisor X DV1200 Series Structural Vibration Detection System (Models DV1201, DV1221). Learn about planning, mounting, wiring, and testing for enhanced security in vaults, safes, ATMs, and more.
Preview Sentrol Security System ZXLCD/ZXVFD Control Station User Manual
Comprehensive guide on operating and understanding Sentrol ZX200, ZX210, ZX400, ZX410, and ZX440F security systems with ZXLCD/ZXVFD control stations. Covers arming, disarming, features, testing, and troubleshooting.
Preview Sentrol 1078CT Series Magnetic Contacts: Installation and Specifications
Detailed installation instructions, specifications, and gap distances for Sentrol 1078CT, 1078CTW, and R1078CT series magnetic contacts for steel doors.
Preview Sentrol 1082 Series Magnetic Contacts: Installation and Specifications
Comprehensive guide to Sentrol 1082 Series screw mount magnetic contacts, detailing installation, UL/ULC specifications, gap distances, and electrical configurations for models 1082, 1083W, 1084D, and 1084W.
Preview Sentrol ZXLCD Control Station User Manual - ZX440F Security System
Comprehensive user manual for the Sentrol ZXLCD Control Station and ZX440F Security Control. Covers system operation, programming, testing, fire detection, and safety precautions.
Preview Sentrol R1078 Magnetic Contacts: Installation Guide and Specifications
Installation guide and technical specifications for the Sentrol R1078 1" Diameter Steel Door Magnetic Contacts, covering installation steps, UL/ULC ratings, and gap distance details.