LOOP - S
for your home
Designed and Made in Germany
Image of the urban shell LOOP - S unit.
Parts List
Component | Quantity | Description |
---|---|---|
Deckel (Lid) | 1 pc. | Image: Lid component. |
Seitenteil (Side Panel) | 2 pcs. | Image: Side panel component. |
Vorderseite (Front Panel) | 1 pc. | Image: Front panel component. |
Rückseite (Rear Panel) | 1 pc. | Image: Rear panel component. |
Fuß links & rechts (Left & Right Feet) | 2 pcs. | Image: Left and right foot components. |
U-Profil (U-Profile) | 2 pcs. | Image: U-shaped profile component. |
Montagehilfe (Mounting Aid) | 4 pcs. | Image: Mounting aid component. |
M6 Screw / Nut | 17 pcs. | Image: M6 screws and nuts. |
M8 Nut / Screw | 4 pcs. | Image: M8 screws and nuts. |
M10 Hammer Head Screw | 4 pcs. | Image: M10 hammer head screws. |
Blocker | - | For mounting, see section Installation Air Separation. Image: Blocker component. |
Note: Screw packages are designed for the largest variant, so some screws may be left over.
Recommended Tools:
- Open-end wrench: M6 (10 mm wrench size), M8 (13 mm wrench size), M10 (17 mm wrench size).
- A ratchet wrench set with appropriate sockets is ideal, especially in tight spaces.
Additionally helpful:
- Torque wrench
- Gloves
Further information (including warranty exclusions, liability limitations, and references to General Terms and Conditions) can be found at: www.urban-shell.com/policies/terms-of-service
Installation - Soundproofing
Note: Soundproofing installation is only relevant if a BASIC or COMFORT soundproofing set was purchased as an accessory. If not, ignore this page.
For optimal adhesion of double-sided tape, proper surface preparation is crucial. Ensure the surface is clean, dry, and free from dust, oil, or grease. Contamination can significantly impair adhesion.
Temperature also plays an important role during application. Most adhesive tapes develop their full adhesive strength only at an application temperature of at least +10°C. At too low temperatures, the adhesive can harden and adhere poorly.
Tip: Press the soundproofing component firmly after application to maximize contact with the surface.
Soundproofing Set Comfort: Apply double to illustrations B & C.
Diagram A: Vorderseite + 7 Lamellen Schallschutz, Rückseite + 5 Lamellen Schallschutz
Diagram showing the attachment of soundproofing material (T01) to the lower edge of the lamellae on the front and rear panels.
Diagram B: Deckel (1x)
Diagram showing the attachment of soundproofing material (T02) to the middle of the lid.
Diagram C: Seitenteil rechts (2x) / links (2x)
Diagram showing the attachment of soundproofing material (T03) to the lower edge of the lamellae and (T04) to the middle of the side panels.
Installation - Blocker
Important Note: The blocker prevents an air short-circuit within the housing. For better illustration, the blocker is shown in yellow; in the actual version, it is black, matching the rest of the soundproofing material.
Image: Unit interior showing the blocker installed, with labels for Luft (air), Blocker, Wärmepumpenrückwand (heat pump rear wall), and Designhaubenrückwand (design hood rear wall).
Diagram (Seitenansicht): Diagram illustrating side view of the unit with blocker, showing air flow and minimum clearances.
Minimum Clearances:
- Height: Device + 80 mm clearance to the lid.
- Width: Device + 80 mm clearance to each side.
- Depth: Device + 80 mm clearance to the rear and 110 mm to the front.
Blocker Installation
Important Note: The number of blocker strips may vary depending on the manufacturer/device type/soundproofing set. The crucial factor is that the blocker fits snugly against the device, leaving no large gaps.
Diagram A: Klebeposition Blocker Seite links (Adhesive position Blocker left side)
Diagram showing the adhesive position for the blocker on the left side.
Diagram B: Klebeposition Blocker Seite rechts (Adhesive position Blocker right side)
Diagram showing the adhesive position for the blocker on the right side.
Diagram C: Klebeposition Blocker Deckel (Adhesive position Blocker lid)
Diagram showing the adhesive position for the blocker on the lid.
Diagram D: Klebeposition Blocker in Haube (Adhesive position Blocker in housing)
Diagram showing the adhesive position for the blocker inside the housing.
Installation - Compressor Housing
Accessory Note: If you have not purchased a compressor housing, please ignore this page.
Installation of the compressor housing is only relevant if one was purchased. If not, ignore this page.
For optimal adhesion of double-sided tape on the back of the insulation nails, proper surface preparation is crucial. Ensure the surface is clean, dry, and free from dust, oil, or grease. Contamination can significantly impair adhesion. Temperature also plays an important role: most adhesive tapes develop their full adhesive strength at a minimum application temperature of +10°C. At lower temperatures, the adhesive can harden and adhere poorly.
Tip: Press the insulation nails firmly after application to maximize contact with the surface.
Images: Insulation nails, insulation clips, and compressor insulation material.
Diagram A: Dämmstoffnägel aufkleben (Stick insulation nails)
Diagram showing how to peel and stick insulation nails onto the unit's front, rear, sides, and lid. Press firmly.
Diagram B: Dämmstoff aufstecken (Attach insulation material)
Diagram showing how to slide the insulation material onto the insulation nails on all four sides.
Diagram C: Clips aufstecken (Attach clips)
Diagram showing how to attach the insulation clips to the tips of the nails. Press to secure.
Diagram D: Fertig (Finished)
Image of the completed compressor housing installation.
Assembly Instructions
Step 1: Deckel + Seite rechts (Lid + Right Side)
Diagram showing the connection of the lid and right side panel using 3 x M6 screws, with an opening at the bottom.
Step 2: Vorderseite + Seite links (Front Panel + Left Side)
Diagram showing the connection of the front panel and left side panel using 3 x M6 screws, with an opening at the bottom.
Step 3: Seite rechts + Fuss rechts (Right Side + Right Foot)
Diagram showing the attachment of the right side panel and right foot. The foot tab (B) is at the bottom, and the side panel cutout (A) is at the top.
Step 4: Seite links + Fuss links (Left Side + Left Foot)
Diagram showing the attachment of the left side panel and left foot. The foot tab (B) is at the bottom, and the side panel cutout (A) is at the top.
Assembly Instructions (Continued)
Step 5: U-Profil auf Dämpfungssockel (U-Profile on Damping Base)
Diagram showing the U-profile being attached to the damping base using 4 x M10 screws.
Step 6: Fuß rechts / links auf Montageschiene stellen (Place Right/Left Feet on Mounting Rail)
Diagram showing the right/left feet being placed on the mounting rail using 4 x M10 screws.
Mounting Aid:
Image: Mounting aid component.
If necessary, mounting aids can be attached to create a support surface for the mounting rails. These are fastened using 4 x M8 screws.
Purpose: Adapter for wall console, extension of mounting rail, washer for grating.
Assembly Instructions (Continued)
Step 7: Vorderseite (Front Panel)
Diagram showing the front panel being secured by screwing nuts onto bolts, leaving a 2mm gap, using 6 x M6 screws.
Step 8: Rückseite (Rear Panel)
Diagram showing the rear panel being secured by screwing nuts onto bolts, leaving a 2mm gap, using 6 x M6 screws.
Step 9: Vorder- und Rückseite (Front and Rear Panels)
Diagram showing the front and rear panels being secured by screwing nuts onto bolts using 4 x M8 screws.
Assembly Instructions (Continued)
Step 10: Vorderseite einhängen (Hang Front Panel)
Diagram showing the front panel being hung into place.
Step 11: Rückseite einhängen (Hang Rear Panel)
Diagram showing the rear panel being hung into place.
Completion Message: You have successfully mounted your LOOP soundproofing hood! We appreciate your feedback – please rate us at: www.urban-shell.com
Accessories
Already have a LOOP soundproofing hood in use? See if practical accessories can enhance your solution!
Soundproofing Sets:
- Level 1: SOUNDPROOFING SET BASIC (up to 6.6 dB damping) - Use of damping material in a simple version for basic soundproofing.
- Level 2: SOUNDPROOFING SET COMFORT (up to 8.0 dB damping) - Increased use of damping material in a comfort version for enhanced soundproofing.
- Level 3: SOUNDPROOFING SET PREMIUM (up to 10 dB damping) - In combination with the Comfort soundproofing set and compressor housing for maximum sound dampening.
Additional Accessories:
- Dämpfungssockel (Damping Feet): 2 pieces. Images: Damping Feet.
- Sockelverkleidung (Socket Cladding). Image: Socket Cladding.
- Diebstahlschutz (Anti-theft Protection). Image: Anti-theft Protection with keys.
Found something nice? Contact us easily via info@urban-shell.com.
Technical Data
Image: Image of the urban shell LOOP unit.
LOOP
Dimensions (H x W x D):
- S: 760 x 1000 x 500 mm
- M: 787 x 1260 x 790 mm
- L: 980 x 1260 x 790 mm
- XL: 935 x 1545 x 963 mm
- M-DS: 1532 x 1260 x 790 mm
- L-DS: 1720 x 1260 x 790 mm
- L-PLUS: 1102 x 1210 x 670 mm
- L-TALL: 1422 x 1110 x 770 mm
- XXL: 1117 x 1650 x 1033 mm
- Special sizes available upon request.
Material:
Full aluminum 2.0 mm
Coating:
Structure Powder Coated
- Gray (RAL 7043) / White (RAL 9002)
- Gray (RAL 7043) / Red (RAL 3009)
- Special colors available upon request.
Sound Tests:
- DIN EN ISO 3744:2011-02
- DIN EN ISO 11546-1:2010-01
- Tested by TÜV Süd
Performance Test:
- No performance or efficiency losses.
- Tested by TÜV Süd.
- DIN EN 14511-2:2023-08