LOOP - S

for your home

Designed and Made in Germany

Image of the urban shell LOOP - S unit.

Parts List

ComponentQuantityDescription
Deckel (Lid)1 pc.Image: Lid component.
Seitenteil (Side Panel)2 pcs.Image: Side panel component.
Vorderseite (Front Panel)1 pc.Image: Front panel component.
Rückseite (Rear Panel)1 pc.Image: Rear panel component.
Fuß links & rechts (Left & Right Feet)2 pcs.Image: Left and right foot components.
U-Profil (U-Profile)2 pcs.Image: U-shaped profile component.
Montagehilfe (Mounting Aid)4 pcs.Image: Mounting aid component.
M6 Screw / Nut17 pcs.Image: M6 screws and nuts.
M8 Nut / Screw4 pcs.Image: M8 screws and nuts.
M10 Hammer Head Screw4 pcs.Image: M10 hammer head screws.
Blocker-For mounting, see section Installation Air Separation. Image: Blocker component.

Note: Screw packages are designed for the largest variant, so some screws may be left over.

Recommended Tools:

Additionally helpful:

Further information (including warranty exclusions, liability limitations, and references to General Terms and Conditions) can be found at: www.urban-shell.com/policies/terms-of-service

Installation - Soundproofing

Note: Soundproofing installation is only relevant if a BASIC or COMFORT soundproofing set was purchased as an accessory. If not, ignore this page.

For optimal adhesion of double-sided tape, proper surface preparation is crucial. Ensure the surface is clean, dry, and free from dust, oil, or grease. Contamination can significantly impair adhesion.

Temperature also plays an important role during application. Most adhesive tapes develop their full adhesive strength only at an application temperature of at least +10°C. At too low temperatures, the adhesive can harden and adhere poorly.

Tip: Press the soundproofing component firmly after application to maximize contact with the surface.

Soundproofing Set Comfort: Apply double to illustrations B & C.

Diagram A: Vorderseite + 7 Lamellen Schallschutz, Rückseite + 5 Lamellen Schallschutz

Diagram showing the attachment of soundproofing material (T01) to the lower edge of the lamellae on the front and rear panels.

Diagram B: Deckel (1x)

Diagram showing the attachment of soundproofing material (T02) to the middle of the lid.

Diagram C: Seitenteil rechts (2x) / links (2x)

Diagram showing the attachment of soundproofing material (T03) to the lower edge of the lamellae and (T04) to the middle of the side panels.

Installation - Blocker

Important Note: The blocker prevents an air short-circuit within the housing. For better illustration, the blocker is shown in yellow; in the actual version, it is black, matching the rest of the soundproofing material.

Image: Unit interior showing the blocker installed, with labels for Luft (air), Blocker, Wärmepumpenrückwand (heat pump rear wall), and Designhaubenrückwand (design hood rear wall).

Diagram (Seitenansicht): Diagram illustrating side view of the unit with blocker, showing air flow and minimum clearances.

Minimum Clearances:

Blocker Installation

Important Note: The number of blocker strips may vary depending on the manufacturer/device type/soundproofing set. The crucial factor is that the blocker fits snugly against the device, leaving no large gaps.

Diagram A: Klebeposition Blocker Seite links (Adhesive position Blocker left side)

Diagram showing the adhesive position for the blocker on the left side.

Diagram B: Klebeposition Blocker Seite rechts (Adhesive position Blocker right side)

Diagram showing the adhesive position for the blocker on the right side.

Diagram C: Klebeposition Blocker Deckel (Adhesive position Blocker lid)

Diagram showing the adhesive position for the blocker on the lid.

Diagram D: Klebeposition Blocker in Haube (Adhesive position Blocker in housing)

Diagram showing the adhesive position for the blocker inside the housing.

Installation - Compressor Housing

Accessory Note: If you have not purchased a compressor housing, please ignore this page.

Installation of the compressor housing is only relevant if one was purchased. If not, ignore this page.

For optimal adhesion of double-sided tape on the back of the insulation nails, proper surface preparation is crucial. Ensure the surface is clean, dry, and free from dust, oil, or grease. Contamination can significantly impair adhesion. Temperature also plays an important role: most adhesive tapes develop their full adhesive strength at a minimum application temperature of +10°C. At lower temperatures, the adhesive can harden and adhere poorly.

Tip: Press the insulation nails firmly after application to maximize contact with the surface.

Images: Insulation nails, insulation clips, and compressor insulation material.

Diagram A: Dämmstoffnägel aufkleben (Stick insulation nails)

Diagram showing how to peel and stick insulation nails onto the unit's front, rear, sides, and lid. Press firmly.

Diagram B: Dämmstoff aufstecken (Attach insulation material)

Diagram showing how to slide the insulation material onto the insulation nails on all four sides.

Diagram C: Clips aufstecken (Attach clips)

Diagram showing how to attach the insulation clips to the tips of the nails. Press to secure.

Diagram D: Fertig (Finished)

Image of the completed compressor housing installation.

Assembly Instructions

Step 1: Deckel + Seite rechts (Lid + Right Side)

Diagram showing the connection of the lid and right side panel using 3 x M6 screws, with an opening at the bottom.

Step 2: Vorderseite + Seite links (Front Panel + Left Side)

Diagram showing the connection of the front panel and left side panel using 3 x M6 screws, with an opening at the bottom.

Step 3: Seite rechts + Fuss rechts (Right Side + Right Foot)

Diagram showing the attachment of the right side panel and right foot. The foot tab (B) is at the bottom, and the side panel cutout (A) is at the top.

Step 4: Seite links + Fuss links (Left Side + Left Foot)

Diagram showing the attachment of the left side panel and left foot. The foot tab (B) is at the bottom, and the side panel cutout (A) is at the top.

Assembly Instructions (Continued)

Step 5: U-Profil auf Dämpfungssockel (U-Profile on Damping Base)

Diagram showing the U-profile being attached to the damping base using 4 x M10 screws.

Step 6: Fuß rechts / links auf Montageschiene stellen (Place Right/Left Feet on Mounting Rail)

Diagram showing the right/left feet being placed on the mounting rail using 4 x M10 screws.

Mounting Aid:

Image: Mounting aid component.

If necessary, mounting aids can be attached to create a support surface for the mounting rails. These are fastened using 4 x M8 screws.

Purpose: Adapter for wall console, extension of mounting rail, washer for grating.

Assembly Instructions (Continued)

Step 7: Vorderseite (Front Panel)

Diagram showing the front panel being secured by screwing nuts onto bolts, leaving a 2mm gap, using 6 x M6 screws.

Step 8: Rückseite (Rear Panel)

Diagram showing the rear panel being secured by screwing nuts onto bolts, leaving a 2mm gap, using 6 x M6 screws.

Step 9: Vorder- und Rückseite (Front and Rear Panels)

Diagram showing the front and rear panels being secured by screwing nuts onto bolts using 4 x M8 screws.

Assembly Instructions (Continued)

Step 10: Vorderseite einhängen (Hang Front Panel)

Diagram showing the front panel being hung into place.

Step 11: Rückseite einhängen (Hang Rear Panel)

Diagram showing the rear panel being hung into place.

Completion Message: You have successfully mounted your LOOP soundproofing hood! We appreciate your feedback – please rate us at: www.urban-shell.com

Accessories

Already have a LOOP soundproofing hood in use? See if practical accessories can enhance your solution!

Soundproofing Sets:

Additional Accessories:

Found something nice? Contact us easily via info@urban-shell.com.

Technical Data

Image: Image of the urban shell LOOP unit.

LOOP

Dimensions (H x W x D):

Material:

Full aluminum 2.0 mm

Coating:

Structure Powder Coated

Sound Tests:

Performance Test:

Models: LOOP S, LOOP S Sound Proofing Hood For Heat Pumps, LOOP S, Sound Proofing Hood For Heat Pumps, Proofing Hood For Heat Pumps, Heat Pumps, Pumps

File Info : application/pdf, 12 Pages, 514.17KB

PDF preview unavailable. Download the PDF instead.

Montageanleitung-LOOP-S

References

Adobe PDF Library 17.0 Adobe InDesign 20.4 (Windows)

Related Documents

Preview LOOP - M-DS Soundproofing Hood Installation and Technical Data
Comprehensive guide for installing the urban shell LOOP - M-DS soundproofing hood for heat pumps and air conditioning units. Includes parts list, assembly instructions, soundproofing and blocker installation, compressor housing, accessories, and technical specifications.