TEST REPORT

Report Number: N°: 145658-697108

Version: 01

Subject: Electromagnetic compatibility (EMC) : Publication CFR 47 PART 15 Subpart C (15.209 & 15.207)

Issued To

SAGEMCOM BROADBAND SAS
250 Route de l'Empereur
92848 RUEIL MALMAISON
FRANCE

Apparatus Under Test

Product:WIFI Home router
Trade mark:OPTIMUM
Manufacturer:SAGEMCOM BROADBAND SAS
Model under test:FAST 5260CV (& FAST 5260)
Serial number:253536653
FCC ID:VW3FAST5260CV (& VW3FAST5260)
Test date:December 14, 2016
Test location:LCIE, Ecuelles
Test performed by:Laurent Deneux
Composition of document:23 pages
Initial issue:December 20, 2016

Report Personnel

Written by: Laurent Deneux (Tests operator)

Approved by: Stephane Phoudiah (Technical manager)

Disclaimer

This document shall not be reproduced, except in full, without the written approval of the LCIE. This document contains results related only to the items tested. It does not imply the conformity of the whole production to the items tested. Unless otherwise specified, the decision of conformity takes into account the uncertainty of measurement. This document doesn't anticipate any certification decision. The COFRAC accreditation attests the technical capability of the testing laboratory for the only tests covered by the accreditation. If some tests mentioned in this report are carried out outside the framework of COFRAC accreditation, they are indicated by an asterisk (*).

Publication History

VersionDateAuthorModification
01December 16, 2016Laurent DeneuxCreation of the document

Summary

  1. TEST PROGRAM (Page 4)
  2. EQUIPMENT DESCRIPTION (DECLARED BY PROVIDER) (Page 5)
  3. MEASUREMENT OF RADIATED EMISSIONS (Page 8)
  4. MEASUREMENT OF CONDUCTED DISTURBANCE (Page 16)
  5. UNCERTAINTIES CHART (Page 23)

1. Test Program

References: CFR 47 Part 15 Subpart C, ANSI 63.10 of 2013

Emission tests:

Test DescriptionMain characteristicsTest result - Comments
Measurement of radiated electric field in shielded room (15.209) Class A
Class B
PASS FAIL NA ☑ NP (Limited Program)
Measurement of radiated electric field in open space (15.209) Class A
Class B
☑ PASS FAIL NA ☐ NP (Limited Program)
Measurement of conducted disturbance on the AC main power port (15.207) Class A
Class B
☑ PASS FAIL NA ☐ NP (Limited Program)

The product is compliant according to CFR 47 Part 15 Subpart C 15.209 & 15.207

Legend:
PASS: EUT complies with standard's requirement
FAIL: EUT does not comply with standard's requirement
NA: Not Applicable
NP: Test Not Performed

2. Equipment Description (declared by provider)

2.1. HARDWARE IDENTIFICATION (EUT AND AUXILIARIES)

Equipment under test (EUT): FAST 5260CV (& FAST 5260)

Serial Number: 253536653

EUT Image 1: Top view of the SAGEMCOM WIFI home router, model OPTIMUM.

EUT Image 2: Side view of the SAGEMCOM WIFI home router, showing the reset button.

EUT Image 3: Rear view of the SAGEMCOM WIFI home router, showing ports and label details (FCC ID, MAC address, Serial Number).

Power Supply Image: Power supply unit, model LPL-D030120250ZL, manufactured by DOKOCOM.

Note: All these tests have been performed on the worst model FAST 5260CV model equipped with 2 USB ports. Due to the similarity between FAST 5260CV and FAST 5260 (the only difference is that FAST 5260 is equipped with only 1 USB port), all results recorded in this test report are applicable for both models FAST 5260 CV & FAST 5260.

Inputs/outputs - Cable

AccessTypeLength used (m)ShieldedUnder testComments
Power supply AC up-1Cat. 5e UTP
WANEthernet10

Supporting Equipment Used During Test

ProductTrade markModelComments
Power supplySAGEMCOMLPL-D030120250ZL12V-DC

Auxiliary equipment (AE) used for testing

ProductTrade markModelComments
ComputerLENOVOR61No subject to the test

Equipment information: (Declared by provider)

Apparatus DescriptionWIFI home router
Type of power source:☑ AC power supply ☐ DC power supply ☐ Battery (Li-ion)
Test source voltage:Vmin-Vmax: ☐ 120V - 60Hz ☑ 7.4Vdc
Operating Modes

Mode 1: Permanent emission with modulation on a fixed channel in the data rate that produced the highest power (802.11g and 802.11ac)

Mode 2: link between WIFI home router and computer on the cable

Mode 3: Ethernet (continuous ping)

Mode 4: -

2.2. EQUIPMENT LABELLING

WIFI HOME ROUTER Label Details: Sagemcom F@st 5260CV, Sagemcom P/N: 253536653, 12VDC/2.5A, S/N: NQ1529409007017, WiFi SSID: F3D430, Password/PIN: 35229247, FCC ID: VW3FAST5260CV, WAN MAC 8C10D4F3D430. Includes UL, CULUS, FCC logos.

POWER SUPPLY Label Details: SWITCH MODE POWER SUPPLY, Sagemcom, P/N:191367698, Model:LPL-D030120250ZL, Input: 100-120V~50/60Hz 0.8A Max, Output: 12V 2.5A. Includes UL, CULUS, VI, LPS, SP, FCC logos. Made in China by DOKOCOM.

2.3. EQUIPMENT MODIFICATIONS

None.

3. Measurement of radiated emissions

3.1. ENVIRONMENTAL CONDITIONS

Test performed by: Laurent Deneux

Date of test: December 14, 2016

Ambient temperature: 18°C

Relative humidity: 47%

3.2. TEST SETUP

The product has been tested according to ANSI C63.10 (2013). The EUT is placed on an open area test site. Distance between measuring antenna and the EUT is 3m. Test is performed in horizontal (H) and vertical (V) polarization with bilog antenna below 1GHz and with a horn antenna above 1GHz. Measurement bandwidth was 120kHz below 1GHz and 1MHz above 1GHz. The level has been maximised by the turntable rotation of 360 degrees range on the 3 axis of EUT. Antenna height search was performed from 1 to 4m. The EUT is place at 1.5m high above 1GHz and at 0.8m high under 1GHz.

Operating mode: Mode 1 ☐ Mode 2 ☐ Mode 3

Image Description: Measurement of radiated disturbances below 1GHz.

Image Description: Measurement of radiated disturbances below 1GHz.

Image Description: Measurement of radiated disturbances above 1GHz.

3.3. LIMIT

at 10m Class A

Frequency Bands/frequenciesdB (µV/m) quasi-peakdB (µV/m) peakdB (µV/m) average
30-88MHz39.5-50
88-216MHz43.9--
216-960 MHz46.9--
960-1000 MHz50--
1000-6000MHz-7050

at 10m Class B

Frequency Bands/frequenciesdB (µV/m) quasi-peakdB (µV/m) peakdB (µV/m) average
30-88MHz29.5--
88-216MHz33--
216-960 MHz35.5--
960-1000 MHz43.5--
1000-6000MHz-63.543.5

3.4. TEST EQUIPMENT LIST

ApparatusTrade MarkTypeRegistration numberCal. DateCal. Due
Open test siteLCIE-F20004002016-052017-05
EMI Test ReceiverROHDE & SCHWARZESIB26A26420212015-122016-12
PreamplifierHELWETT PACKARD8449BA70800712016-012017-01
Bilog antennaCHASECBL 6112AC20400402016-012017-01
HornETS3115C20420232016-012017-01
Cable--A53295422016-032017-03
Cable--A53294492016-102017-10
Cable--A53293682016-052017-05
Cable--A53294442016-102017-10

3.5. RESULTS

FCC Part.15 class B (30 to 1000MHz)

Diagram N°1: Graph showing Quasi peak measurement for radiated emissions. The X-axis represents Frequency (MHz) from 30MHz to 1GHz. The Y-axis represents levels in dBµV/m. The graph displays measured quasi-peak levels (vertical and horizontal polarization) against the Class B limit.

The radiated measurements were performed in both vertical and horizontal polarization. The worst case has been recorded after maximization levels.

Worst frequencies for radiated emissions

Frequency (MHz)Peak Level (dBµV/m)Limit (dBµV/m)Margin
37535.1235.50.38
42533.9835.51.52
62535.2135.50.29
75034.7735.50.73
87533.6935.51.81

FCC Part.15 class B (1 to 18GHz)

Diagram N°2: Graph showing Peak measurement for radiated emissions from 1GHz to 18GHz. The X-axis represents Frequency (MHz). The Y-axis represents levels in dBµV/m. The graph displays measured peak levels (vertical and horizontal polarization) against the Class B limit.

The radiated measurements were performed in both vertical and horizontal polarization. The worst case has been recorded after maximization levels.

FCC Part.15 class B (1 to 18GHz)

Diagram N°3: Graph showing Average value measurement for radiated emissions from 1GHz to 18GHz. The X-axis represents Frequency (MHz). The Y-axis represents levels in dBµV/m. The graph displays measured average levels (vertical and horizontal polarization) against the Class B limit.

The radiated measurements were performed in both vertical and horizontal polarization. The worst case has been recorded after maximization levels.

3.6. CONCLUSION (Radiated Emissions)

Measures of Radiated Emission, performed on the sample of the product FAST 5260CV (& FAST 5260), SN: 253536653, in configuration and description presented in this test report, show levels conform to the FCC part 15.209 limits.

4. Measurement of conducted disturbance

4.1. ENVIRONMENTAL CONDITIONS

Test performed by: Laurent Deneux

Date of test: December 14, 2016

Ambient temperature: 21°C

Relative humidity: 47%

4.2. TEST SETUP

Specifications:
Frequency: 0.15 – 30 MHz
Detector: Peak, Quasi Peak and average
RBW: 9 kHz

The measurement is performed on power supply with a LISN and telecommunication lines with RSI or current clamp for shielded cables.

Operating conditions:

Deviation method: ☐ Yes ☑ No

Product installation:
☑ The EUT is installed on a wooden table 80 cm above the reference plane, at 80cm of the LISN and at 40cm of the vertical conductive wall.
☐ The EUT is installed on a wooden table 40 cm above the reference plane, at 80cm of the LISN.
☐ The EUT is installed 10 cm above the reference plane, at 80cm of the LISN..

Operating mode: Mode 1 ☐ Mode 2 ☐ Mode 3 ...

Diagram Description: Test set up of conducted emission on power supply. The setup includes a measuring receiver, pulse limiter, LISN, and the EUT. Distances are indicated: 80cm from LISN to EUT, 40cm from EUT to conductive wall, 80cm from EUT to reference plane. The setup is on a wooden table, with a ground plane and a conductive wall present.

Image Description: Test set up of conducted emission on power supply.

Image Description: Test set up of conducted emission on power supply.

4.3. LIMIT

Power supply Class A

Frequency Bands/frequenciesdB (µV/m) quasi-peakdB (µV/m) average
0.15-0.5MHz7966
0.5-30 MHz7360

Power supply Class B

Frequency Bands/frequenciesdB (µV/m) quasi-peakdB (µV/m) average
0.15-0.5MHz66-5656-46
0.5-5 MHz5646
5-30 MHz6050

4.4. TEST EQUIPMENT LIST

DescriptionManufacturerModelIdentifierCal. DateCal. Due
EMI Test ReceiverROHDE & SCHWARZESIB26A26420212015-122016-12
V ISLNROHDE & SCHWARZESH2-Z5C23220012016-052017-05
Pulse limiterROHDE & SCHWARZESH3-Z2A26490082016-032017-03
Cable--A53294172016-102017-10
Cable--A53295892016-102017-10
Ground planeLCIE----

4.5. RESULTS

Phase Line

Diagram N°1: Graph showing Phase Line conducted emissions. The X-axis represents Frequency (MHz) from 150kHz to 30MHz. The Y-axis represents levels in dBµV. The graph displays measured peak and quasi-peak levels against the Class B limits for phase line.

Frequency (MHz)Peak Level (dBµV)Quasi-Peak Level (dBµV)Quasi-Peak Limit (dBµV)Margin Quasi-peakAverage Level (dBµV)Average Limit (dBµV)Margin Average Limit
15447.5-65.718.234.455.721.3
39639.5-5818.536.54811.5
406633.8-5622.221.34624.7
673037.6-6022.426.75023.3
1169435-6025255025

Neutral Line

Diagram N°2: Graph showing Neutral Line conducted emissions. The X-axis represents Frequency (MHz) from 150kHz to 30MHz. The Y-axis represents levels in dBµV. The graph displays measured peak and quasi-peak levels against the Class B limits for neutral line.

Frequency (MHz)Peak Level (dBµV)Quasi-Peak Level (dBµV)Quasi-Peak Limit (dBµV)Margin Quasi-peakAverage Level (dBµV)Average Limit (dBµV)Margin Average Limit
15155-65.810.83455.821.8
40137-57.820.833.547.814.3
102631.7-5624.3264620
306632.5-5623.524.54621.5
1060628.8-6031.219.25030.8

4.6. CONCLUSION (Conducted Emission)

Measures of Conducted Emission, performed on the sample of the product FAST 5260CV (& FAST 5260), SN: 253536653, in configuration and description presented in this test report, show levels conform to the FCC part 15.207 limit.

5. Uncertainties Chart

Kind of measurementWide uncertainty laboratory (k=2) ±x(dB)CISPR uncertainty limit ±y(dB)
Measurement of conducted disturbances in voltage on the AC power port (9 kHz – 150 kHz)2.673.8
Measurement of conducted disturbances in voltage on the AC power port (150 kHz – 30 MHz)2.673.4
Measurement of conducted disturbances in voltage on the telecommunication port. (AAN)3.675.0
Measurement of conducted disturbances in current (current clamp)2.732.9
Measurement of disturbance power2.674.5
Measurement of radiated magnetic field from 10kHz to 30MHz in SAC V014.48/
Measurement of radiated magnetic field from 10kHz to 30MHz in SAC C014.48/
Measurement of radiated electric field from 30 to 1000MHz in horizontal position on the OATS (Ecuelles)4.886.3
Measurement of radiated electric field from 1 to 18GHz on the Ecuelles site5.16/
Measurement of radiated electric field from 30 to 1000MHz in vertical position on the OATS (Ecuelles)4.996.3
Measurement of radiated electric field from 30 to 1000MHz in horizontal position in SAC C015.086.3
Measurement of radiated electric field from 30 to 1000MHz in vertical position in SAC C015.166.3
Measurement of radiated electric field from 30 to 1000MHz in horizontal position in SAC V015.086.3
Measurement of radiated electric field from 30 to 1000MHz in vertical position in SAC V015.156.3
Measurement of radiated electric field from 1 to 6 GHz C015.15.2
Measurement of radiated electric field from 1 to 6 GHz V014.855.2
Measurement of radiated magnetic field from 10kHz to 30MHz on the OATS (Ecuelles)4.48/

End of test report

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=3237171 PDFTechLib 1.7.36.0 by PDF Technologies, Inc. PDF Technologies, Inc http://www -technologies.com

Related Documents

Preview Sagemcom FAST5260 Test Setup Photos and Configurations
Detailed visual documentation of the test setups used for regulatory compliance testing of the Sagemcom FAST5260 router, including power line conducted emissions and radiated field strength measurements.
Preview Sagemcom FAST 5285 Router: Safety, Installation, and FCC Compliance
Essential safety, installation, and FCC compliance information for the Sagemcom FAST 5285 wireless router, including usage instructions and regulatory statements.
Preview Sagemcom FAST5260 Declaration for Non-Transmission Information
Declaration from Sagemcom Broadband SAS regarding the non-transmission capabilities of the FAST5260 device in the 5GHz frequency band, submitted to the FCC.
Preview Sagemcom FAST 3896 UM Router: Safety, Installation, and FCC Compliance Guide
Comprehensive safety, installation, and regulatory compliance information for the Sagemcom FAST 3896 UM router, including FCC statements, RF interference, and wall-mounting guidance.
Preview Sagemcom F5380 WiFi 6 Router User Guide and Safety Information
Comprehensive user guide and safety instructions for the Sagemcom F5380 and FAST 5380 (CWR226e) WiFi 6 routers, covering installation, safe usage, and FCC compliance.
Preview Sagemcom FAST 5295 Router: Installation and Safety Instructions
Provides essential installation and safety guidelines for the Sagemcom FAST 5295 router, covering placement, connections, and important precautions for safe operation.
Preview Sagemcom FAST 5290 Installation and Safety Instructions
Provides essential installation and safety guidelines for the Sagemcom FAST 5290 router, including setup instructions, electrical safety precautions, and FCC compliance information.
Preview Sagemcom FAST 3896-15 EU Declaration of Conformity
EU Declaration of Conformity for the Sagemcom FAST 3896-15 Residential Gateway, confirming compliance with essential European directives and harmonized standards.