Raychem T2Blue - 20 W/m

Floor Heating Cable

Description

[12 Year Total Care Warranty]

Raychem T2Blue 20 W/m is a floor heating cable with constant power output of 20 W/m. It is a pre-terminated, dual conductor heater with a 2.5 m cold lead attached at one end. The heating cable should be embedded in screed (typically 50 mm).

T2Blue is the ideal floor heating system for installation in newly constructed buildings or renovation. This floor heating cable is typically applied in new construction applications and building extensions, for example in conservatories or cold rooms (refrigeration rooms).

The T2Blue range exists in a variant without thermostat and in an EcoDesign compliant variant containing a programmable electronic timer thermostat. The T2Blue comes in a handy installer friendly box containing glue sticks for easy fixing to the subfloor and a conduit in which to install the sensor.

An image shows a person installing a floor heating cable. The cable is being laid out on a tiled subfloor, with a portion embedded in screed. Another part of the cable is shown with its cold lead connection.

Advantages

The design phase

Compatible with all non-combustible and stable subfloors, e.g., concrete, anhydrite, plaster, ceramic underfloor. Following floorings can be applied: Tiles, Marble, Stones with max. 30 mm thickness and min. thermal conductivity of 1.0 W/(mK).

The installation phase

Due to the dual conductor cable, T2Blue has only one cold lead connection, which enables easy lay-out and installation. Easy to adapt to special room shapes or obstacles. Spacing can be varied to a minimum of 50 mm.

The application

Technical Data

Nominal power
20 W/m
Voltage
230 Vac
Max. Exposure Temperature
+90°C
Min. Installation Temperature
+5°C
Length of cold lead cable
2.5 m
Dimensions
Approx 5.5 mm diameter
Min. cable spacing
50 mm
Min. bending radius
30 mm
RCD
30 mA
Construction
PVC-free
Certificates
SEMKO, VDE, CE-mark

Design Table

T2Blue 20 W/m products are available in heating cable lengths from 11 m till 115 m.

Product Output (W) Length (m) Heating cable resistance range @ 20°C Area (m²)
80 W/m² 100 W/m² 125 W/m² 150 W/m²
T2Blue-20-11 m20511246.6 - 285.6 Ω2.62.01.61.4
T2Blue-20-14 m28514176.9 - 204.8 Ω3.62.92.31.9
T2Blue-20-18 m35518145.4 - 168.3 Ω4.43.62.82.4
T2Blue-20-21 m43521115.7 - 134.0 Ω5.44.43.52.9
T2Blue-20-28 m5752887.8 - 101.6 Ω7.25.84.63.8
T2Blue-20-35 m7203569.8 - 80.9 Ω9.07.25.84.8
T2Blue-20-43 m8454359.6 - 69.1 Ω10.68.56.85.6
T2Blue-20-50 m9805051.3 - 59.4 Ω12.39.87.86.5
T2Blue-20-57 m11305744.4 - 51.4 Ω14.111.39.07.5
T2Blue-20-63 m12706339.5 - 45.7 Ω15.912.710.28.5
T2Blue-20-71 m14357135.1 - 40.6 Ω17.914.411.59.6
T2Blue-20-86 m17108629.4 - 34.1 Ω21.417.113.711.4
T2Blue-20-101 m201510124.9 - 28.9 Ω25.220.216.113.4
T2Blue-20-115 m230011521.9 - 25.3 Ω28.823.018.415.3

Cable spacing (mm) = x = [area (m²) / length (m)] x 1000

Cable spacing values for reference: 250 mm, 200 mm, 160 mm, 135 mm

Underfloor Preparation and Installation Instruction

The subfloor should be clean, stable and rigid, without cracks or adhesion-reducing substances. Cracks are to be filled.

Ensure subfloor is level. When using cement plaster and anhydrite plaster, ensure that the floor has dried sufficiently according to the applicable norms. Anhydrite plaster should be smoothened and dust-free. With quickly solidifying plaster, please follow the manufacturer's instructions.

The heating cable should not be installed under bath tubs, shower cabins, surface covering furniture, etc.

The heating cable should not be installed where holes will be drilled in the floor.

T2Blue heating cable needs to be installed in a screed (typically 50 mm). It should not be installed directly in the tile adhesive. The heating cable should not be embedded in EPS cement screed.

A cross-section diagram illustrates the layers of an underfloor heating installation. From bottom to top, it shows: Insulated subflooring (concrete, wood), a layer of filler, the T2Blue heating cable, tile adhesive, and finally, tiles. Metal mesh is also depicted, likely for support or installation aid.

Applicable norms, rules, and data sheets, as well as instructions and manuals, are to be followed! For detailed installation instructions, reference is INST279.

Contact Information

Europe, Middle East, Africa, India

Tel: +32 16 213 511

Fax: +32 16 213 604

Email: info@chemelex.com

Website: chemelex.com

PDF preview unavailable. Download the PDF instead.

RAYCHEM-DS-EU1691-T2Blue20-EN Adobe PDF Library 17.0 Adobe InDesign 20.4 (Macintosh)

Related Documents

Preview Raychem Self-Regulating Heating Cable: The Original and Reliable Solution
Explore Raychem's original self-regulating heating cable, detailing its performance characteristics based on ambient temperature (cold, warm, hot). Learn about its user-friendly and reliable features, historical significance, and industry certifications. Includes contact information for Chemelex, a leading manufacturer.
Preview Raychem XPI-S Polymer Insulated Resistance Heating Cable Datasheet
Comprehensive datasheet for the Raychem XPI-S Polymer Insulated (PI) series resistance heating cable. Details product overview, technical specifications, hazardous area approvals, and ordering information for industrial heating applications.
Preview Raychem MI Heating Cable System Installation and Operation Manual
Comprehensive guide for the installation, operation, and maintenance of Raychem MI heating cable systems for various applications including heat loss replacement, freezer frost heave prevention, comfort floor heating, and radiant space heating. Covers safety guidelines, electrical codes, component installation, power supply, commissioning, and troubleshooting.
Preview Raychem GM-2X-KIT: Installation Guide for Gutter and Downpipe Frost Protection
Installation instructions and technical data for the Raychem GM-2X self-regulating heating cable kit, designed for frost protection of gutters and downpipes. Includes kit contents, installation steps, and specifications.
Preview Raychem WinterGard Cable: Installation Guide for Ramp and Accessway Heating
Comprehensive installation guide for Raychem WinterGard Cable systems, designed for reliable snow and ice melting on ramps and accessways. Covers 230V and 400V models, detailing layout, installation, testing, and troubleshooting.
Preview Raychem Mineral Insulated Cable Repair Guide: Procedures and Safety
Comprehensive guide for repairing and modifying Raychem Mineral Insulated (MI) heating cables by Chemelex. Covers safety, tools, repair kits, joining, end caps, and testing for copper and Alloy 825 sheath cables.
Preview Raychem SC Series Resistance Heat-Tracing: Installation & Maintenance Manual
Comprehensive guide for installing and maintaining Raychem SC Series Resistance heat-tracing systems on industrial pipes. Covers safety, installation procedures, testing, and troubleshooting.
Preview Raychem XTVR Self-Regulating Heating Cable | Technical Specifications & Application
Detailed information on the Raychem XTVR self-regulating heating cable, including technical specifications, application guidelines, thermal output ratings, circuit length calculations, and product certifications for freeze protection and process temperature maintenance.