LG KSSAL121A R32 Art Cool Deluxe Single-Zone Heat Pump System Specifications

LG KSSAL121A R32 Art Cool™ Deluxe Single-Zone Heat Pump System

Outdoor Unit (ODU): KUSAL121A

Indoor Unit (IDU): KNSAL121A

Performance

Cooling

CharacteristicValue
Cooling Capacity (Min~Rated~Max) (Btu/h)3,070~12,000~14,100
SEER225.5
EER213.8

SEER - Seasonal Energy Efficiency Ratio, EER - Energy Efficiency Ratio

Heating

CharacteristicValue
Heating Capacity (Min~Rated~Max) (Btu/h)3,070~13,000~20,000
HSPF211.2
Max. Heating @ Indoor 70°F DB
Outdoor 19°F DB / 17°F WB16,820 (129%)
Outdoor 6°F DB / 5°F WB14,700 (113%)
Outdoor -3°F DB / -4°F WB14,000 (108%)
Outdoor -12°F DB / -13°F WB13,000 (100%)
Outdoor -30°F DB / -31°F WB9,100 (70%)

HSPF - Heating Seasonal Performance Factor

Nominal Test Conditions
Cooling: Indoor: 80°F DB / 67°F WB, Outdoor: 95°F DB / 75°F WBHeating: Indoor: 70°F DB / 60°F WB, Outdoor: 47°F DB / 43°F WB

Electrical

CharacteristicValue
Power Supply (V/Hz/Ø)208-230/60/1
MOP (A)20.0
MCA (A)15.0
Cooling Rated Amps (A)10.4
Heating Rated Amps (A)10.4
Compressor (A)10.0
Fan Motor (IDU + ODU) (A)0.4 + 0.4
Cooling Power Input (kW) (Min~Rated~Max @95°F) (kW)0.200~0.870~1.600
Heating Power Input (kW) (Min~Rated~Max @47°F) (kW)0.190~0.934~2.000

MOP - Maximum Overcurrent Protection, MCA - Minimum Circuit Ampacity

Piping

CharacteristicValue
Liquid Line (in., O.D.)1/4 Flare
Vapor Line (in., O.D.)3/8 Flare
Additional Refrigerant (oz./ft.)0.16
Min. / Max. Pipe Length (ft.)²9.8 / 65.6
Piping Length (no add'l refrig., ft.)24.6
Max. Elevation (ft.)39.4

Operating Range

Outdoor Unit

CharacteristicValue
Cooling (°F DB)14 ~ 118
Heating (°F WB)-31 ~ +65

Indoor Unit

CharacteristicValue
Cooling (°F WB)53 ~ 75
Heating (°F DB)60 ~ 86

System Data

CharacteristicValue
Refrigerant TypeR32
Refrigerant ControlEEV
Refrigerant Charge (lbs.)2.54
ODU Sound Pressure (Cooling / Heating) (±1 dB[A])³48 / 50
IDU Sound Pressure Cooling (H/M/L/SL) (±1 dB[A])³42 / 35 / 27 / 21
Heating (H/M/L) (±1 dB[A])³42 / 35 / 27
ODU Net / Shipping Weight (lbs.)99.2 / 109.1
IDU Net / Shipping Weight (lbs.)24.3 / 28.7
Heat Exchanger CoatingGold Fin™

Fan

CharacteristicValue
ODU TypePropeller
IDU TypeCross Flow
Fan Speeds (Fan/Cool/Heat)6 / 6 / 6
Quantity (ODU + IDU)1 + 1
Motor/DriveBrushless Digitally Controlled/Direct
ODU Max. Air Flow Rate (CFM)1,730
IDU Air Flow Cooling, Max/H/M/L (CFM)494 / 424 / 318 / 219
Heating, Max/H/M/L (CFM)515 / 424 / 318 / 219
Dehumidification (pts./hr.)3.59

Notes

  1. Acceptable operating voltage: 187V-253V.
  2. Piping lengths are equivalent.
  3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
  4. All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied and must be a minimum of four-conductor, 14 AWG, stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes.
  5. See Engineering Manual for sensible and latent capacities.
  6. Power wiring cable size must comply with the applicable local and national code.
  7. The indoor unit comes with a dry helium charge.
  8. This data is rated 0 ft. above sea level, with 24.6 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor units.
  9. Installation instructions in the applicable LG installation manual must be followed.

Features

Included Accessories

Optional Accessories

Controller Options

BACnet® is a registered trademark of ASHRAE. LonWorks® is a registered trademark of Echelon Corp.

ENERGY STAR®

Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps (excluding ductless systems) must be matched with appropriate coil components to meet ENERGY STAR® criteria. For details, visit www.energystar.gov.

(ENERGY STAR and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency.)

AHRI CERTIFIED®

www.ahridirectory.org

Unitary Small HP, AHRI Standard 210/240

Certification applies only when the complete system is listed with AHRI.

Dimensional Diagrams

Outdoor Unit (ODU) - KUSAL121A Chassis (U24A)

This section describes the physical dimensions and key components of the outdoor unit, with measurements provided in inches (mm).

  • Overall Dimensions: The unit has a rectangular footprint, with various protrusions for connections and airflow.
  • Sump Heater: Located at the base of the unit.
  • Drain Hole: Approximately 6-025/32 inches (20 mm) in diameter.
  • Control Box: Positioned on one side, approximately 3-1/16 inches (78 mm) from the top edge.
  • Service Valve Cover: Located near the control box.
  • Piping Connections:
    • Liquid Pipe Connection (Flare): Located on the side, approximately 6-17/32 inches (166 mm) from the bottom.
    • Vapor Pipe Connection (Flare): Located adjacent to the liquid pipe connection, approximately 7-9/16 inches (192 mm) from the bottom.
  • Power and Communication Cable Access: Located on the side, approximately 4-19/32 inches (117 mm) from the bottom.
  • Air Outlet: A large circular opening on the top of the unit, approximately 20-9/32 inches (515 mm) in diameter, for air discharge.
  • General Views: Diagrams show the unit from multiple perspectives, including top, side, and front views, illustrating the placement of the fan, grilles, and connection points. The unit's height is approximately 23-1/16 inches (586 mm), width approximately 34-1/4 inches (870 mm), and depth approximately 15-3/16 inches (386 mm).

Indoor Unit (IDU) - KNSAL121A Chassis (S1)

This section details the physical dimensions and key components of the indoor unit, with measurements provided in inches (mm).

  • Overall Dimensions: The unit is designed for wall mounting, with a sleek, rectangular profile.
  • Air Intake Hole: Located on the top surface, approximately 32-11/16 inches (830.4 mm) long.
  • Air Outlet Hole: Located on the bottom surface, approximately 30-41/64 inches (778.3 mm) long.
  • Display & Remote Controller Signal Receiver: Positioned on the front face of the unit.
  • Drain Hose Connection: Located on the right side of the unit, approximately 5-17/64 inches (133.8 mm) from the bottom.
  • Terminal Block for Power Supply and Communication: Located on the right side, accessible for wiring.
  • Installation Plate: The unit mounts to an installation plate, with specific drilling hole dimensions provided (e.g., 10-5/32 inches (257.9 mm) between mounting points).
  • Refrigerant, Drain Pipe and Cable Routing Knock-Out Hole: Located on the back of the unit for routing connections.
  • Airflow Direction Indicators: Diagrams indicate airflow directions for both intake and outlet.
  • General Views: Diagrams provide front, side, and top views, showing the unit's slim profile and the location of various access points and connections. The unit's width is approximately 35-15/64 inches (894.9 mm), height approximately 12-1/8 inches (308.1 mm), and depth approximately 8-9/32 inches (210.3 mm).
Models: KSSAL121A, KUSAL121A, KNSAL121A, KNSAL121A Art Cool Deluxe Ductless Mini Split Heat Pump System, Art Cool Deluxe Ductless Mini Split Heat Pump System, Deluxe Ductless Mini Split Heat Pump System, Mini Split Heat Pump System, Heat Pump System, Pump System

File Info : application/pdf, 3 Pages, 2.26MB

PDF preview unavailable. Download the PDF instead.

9224a88529f73f67b26300b6aa4bb254

References

Adobe InDesign 20.0 (Windows) Adobe PDF Library 17.0; modified using iTextSharp 4.1.6 by 1T3XT

Related Documents

Preview LG KSSMA36CA R32 Single-Zone System: Technical Specifications
Detailed technical specifications, performance data, and features for the LG KSSMA36CA R32 Single-Zone System with LGRED® A-Coil, including outdoor and indoor unit details, operating ranges, and electrical requirements.
Preview LG KSSAP241A R32 Single-Zone Extended Piping Wall Mount - Technical Specifications
Detailed technical specifications and performance data for the LG KSSAP241A R32 Single-Zone Extended Piping Wall Mount ductless mini-split air conditioning system, including cooling and heating capacities, electrical requirements, and dimensions.
Preview LG KSUAB121A R32 Single Zone High Efficiency Wall Mounted Air Conditioner Specifications
Detailed specifications, performance data, system information, and dimensional diagrams for the LG KSUAB121A R32 Single Zone High Efficiency Wall Mounted Air Conditioner. Includes electrical requirements, piping, features, and accessories.
Preview LG LA181HSV5 Single Zone Art Cool Mirror Wall Mounted Air Conditioner Specifications
Detailed specifications for the LG LA181HSV5 Single Zone Art Cool Mirror Wall Mounted Air Conditioner, including performance data, operating ranges, system details, electrical requirements, and control features.
Preview LG KSUJB181A Single Zone Mid Static Ducted HVAC System Specifications
Detailed technical specifications for the LG KSUJB181A Single Zone Mid Static Ducted HVAC system, including performance data, electrical requirements, piping information, and operating ranges. Features Smart Inverter technology and GoldFin™ heat exchanger coating.
Preview LG KSUQB091A R32 Single Zone Low Wall Console Technical Specifications
Detailed technical specifications and performance data for the LG KSUQB091A R32 Single Zone Low Wall Console air conditioning system, including cooling and heating capacities, operating ranges, electrical requirements, and physical dimensions.
Preview LG KSSAE091A R32 Single Zone Standard Efficiency Wall Mounted Air Conditioner Specifications
Detailed technical specifications for the LG KSSAE091A R32 Single Zone Standard Efficiency Wall Mounted Air Conditioner, including performance, electrical, piping, features, operating ranges, system data, and dimensions for both indoor and outdoor units.
Preview LG KSSAC241A R32 Single Zone Mega Wall Mount Air Conditioner Specifications
Detailed specifications for the LG KSSAC241A R32 Single Zone Mega Wall Mount Air Conditioner, including performance, operating range, electrical, piping, system data, features, and dimensions.