Erden Brass EB2-U Uplight

Model: LS3320

Overview

The EB2 is a compact, factory-sealed inground luminaire designed for harsh exterior environments. It features a corrosion-resistant brass body, an IP68 rating, and MicroAntileach cable entry, ensuring long-term reliability in coastal, urban, or high-moisture settings without requiring drainage.

Available in vertical or 15° angled uplight options, the EB2 supports RGBW, RGBA, Static, and Tunable White output. It offers DMX/RDM control via PowerSync, enabling dynamic lighting scenes and remote management.

Optical accessories such as wall-wash lenses, hex-cell louvers, and glare shields are available to provide beam control and visual comfort. The luminaire lid is offered in brass, which develops an elegant natural patina over time, or cast 316 stainless steel, known for its superior corrosion resistance and durability in high-salinity, high-exposure environments.

The EB2 is drive-over rated and compact with a 4.7" (120 mm) diameter, delivering up to 810 lumens. It can be installed easily via direct burial, pre-installation kits, or a 4" conduit system, making it suitable for discreet yet powerful architectural or landscape lighting.

Performance

Static White

Color Temperature (CRI) Lumen Output (lm) Efficacy (lm/W) Peak Intensity (cd)
2,700 K (80 CRI) 730 84 10,000
3,000 K (80 CRI) 780 90 10,700
3,500 K (80 CRI) 760 87 10,400
4,000 K (80 CRI) 810 93 11,100

¹ Lumen output is based on 14° lens. ¹ Also available in 90 CRI.

Dynamic Colour

Color Type Lumen Output (lm) Efficacy (lm/W) Peak Intensity (cd)
RGBA 310 40 4,300
RGBW (4,000 K) with Royal Blue* 380 43 5,800

² Lumen output is based on 12° lens.

Tunable White

Color Temperature Range Lumen Output (lm) Efficacy (lm/W) Peak Intensity (cd)
2,700 K - 6,500 K 640 78 9,200

³ Lumen output is based on 12° lens.

Beam Angles

Available beam angles include: 12°, 14°, 20°, 25°, 35°, 45°, 50°, 55°, 10° x 40°, 40° x 10°, 20° x 60°, 60° x 20°, and Wall Wash options.

Specifications

Electrical

Power Consumption < 9 W
Lifetime 84,309 hours @ 50°C Ambient (B10, L90, TM21 Projected)
Input Voltage Low Voltage, 30 to 48 Vdc
Thermal Management CoolDrive™ onboard thermal monitoring and control

Control

Interface Lumascape PowerSync™
Protocols DMX/RDM, Artnet¹, 0-10 V (sink or source)²
PWM Frequency 2 kHz flicker-free dimming to 0.1%
RDM Functionality PowerSync enabled luminaires ship with a default RDM personality for smooth dimming. The personality can be changed via industry standard DMX/RDM for different dimming characteristics or special functionalities.
Systems Supports a range of third-party controllers.

¹ Some protocols require additional hardware. Contact Lumascape for details. ² Not available for color-changing or tunable white.

Physical

Housing Die-cast brass body with stainless-steel or brass lid
Installation Options
  • Pre-Installation blockout for concrete pour, drive-over, and general use applications.
  • Conduit Mount for mounting in 4" SCH 40 conduit (by others).
  • Direct burial for landscapes, planters, and special applications.
Adjustability Wiring: 84 (flexible cable), 82 (½" NPT) for Direct Burial and Pre-Install.
Ambient Operating Temperature -40°F to 122°F (-40°C to 50°C)
Surface Temperature < 149°F (< 65°C)
Weight 4.2 lb (1.9 kg)
Drive-Over With pre-installation kit (LS6388) installed in concrete as per instructions³.

³ With soft tires at low speed, no braking or changing direction.

Certification & Compliance

IP Rating IP68
IK Rating IK8
Static Load Rating 6,614 lb (3,000 kg)
Environment Dry, Damp, Wet Locations. Inherently protected. Suitable for use in poured concrete. No drainage required.
Certifications UL (USA & Canada), CE, RCM, FCC

Dimensions

Diagram showing dimensions for Direct Burial installation. It illustrates the luminaire's profile with angle options (0°, 15°) and key dimensions: 4.7" (120mm) diameter, 4.4" (112mm) height, and a 3.9" (100mm) internal diameter. An optional glare shield is also depicted.

Diagram illustrating dimensions for the Pre-Install (LS6388) configuration. It shows the luminaire fitting into the LS6388 blockout, with dimensions for the blockout (4.7" / 120mm diameter, 6.7" / 170mm depth) and the luminaire's overall height (11.2" / 284mm).

Diagram detailing dimensions for the Conduit Mount (LS6389). It shows the luminaire installed within a 4" (100mm) conduit, indicating conduit dimensions and the luminaire's placement within it.

Installation Methods & Accessories

Installation Types

Pre-Installation Blockout

This method requires the LS6388 Pre-Installation Kit (ordered separately). It acts as a concrete blockout installed before the luminaire, protecting it from damage during concreting or other site works. It is used for drive-over, general use, and concrete pour applications where the luminaire is installed after site work is completed. Benefits include easy removal for servicing.

Conduit Mount

This installation allows the luminaire to be locked into a standard schedule 40, 4" (100mm) conduit (supplied by others). This protects the luminaire during site works. It is used for drive-over, general use, and concrete pour applications. Benefits include easy removal for servicing. The conduit can be procured locally.

Direct Burial

The luminaire is installed directly into soil or soft landscapes. It is used for landscaping areas and applications where depth is restricted. Benefits include simple installation and easy repositioning as landscapes evolve. It is not suitable for drive-over applications and requires pre-installation. Connection Type '82' is only available for the North American market.

Connection Types

Connection type '84'

Features Flexible Cable for connections to the branch circuit via junction box (by others) or other approved method. Available in 6.5' (2 m) length, with other lengths available upon contact with Lumascape.

Connection type '82'

Features a ½" NPT Adapter. The luminaire is factory-fitted with 6.5' (2 m) hookup wire. Ensure terminations can be made within this length. For other length options, consult Lumascape. This type is North American market only.

Round Flush Cover

Flush covers are used for installation in fine finished surfaces like granite and marble, and in some suspended applications to conceal gaps between the luminaire and the surrounding surface. They ensure static loads up to 6,614 lb (3,000 kg) are properly supported, requiring OptiClear™ or GripGlass™ for drive-over rating.

Available finishes:

Accessories

PowerSync Low Voltage 30-48 Vdc Data Injector (LS6550)

Translates control signals into a digital format, delivering integral power and data to intelligent LED luminaires. It enables highly-granular addressing and high-speed digital control using three wires. The data injector is DIN rail mountable and designed for installation in a switchboard. It accepts standard protocols (0-10 V, DMX/RDM) for integration with various control systems.

Note: PowerSync Data Injector ships with three (3) hardwired terminators and one (1) hardwired DMX terminator.

Pre-Installation Kit (LS6388)

This kit acts as a concrete blockout, intended for installation before the luminaire to prevent damage during site works. It is ordered separately.

External Glare Shield (LS6265)

Integration of the LS6265 is supported only in pre-install configurations. Available in Tumbled Brass finish (TB).

Specification Matrix

The following matrix details how to configure the Erden Brass EB2-U Uplight by selecting codes for various features.

Power

CodePower
09W9 W
09D9 D

Static White

CodeColor Temperature (80 CRI)
8272,700 K
8303,000 K
8353,500 K
8404,000 K

90 CRI LEDs available on request.

Dynamic Color

CodeColor Type
4CARGBA
4BWRGBW with Royal Blue

The default RGBW colors have recently changed to RGBW with Royal Blue (4BW code). These may not match existing products with the earlier RGBW with Mid-Blue (4CW code). Contact Lumascape for custom LED Colors.

Tunable White

CodeColor Temperature Range
2WT2,700 K - 6,500 K

Lens

CodeLens Type
AOptiClear™
MGlare mask

¹ Only for Static White.

Cover

CodeCover Type
MStainless steel, electro polished, flush
KBrass, tumbled, flush
VBrass, tumbled wt. glare shield

¹ Factory fitted accessory.

Connection Type

CodeConnection Type
84Flexible cable, single entry, for hardwired installations
82Hookup wire and ½" NPT, single entry, for hard wired installations (North America).

Beam Angle (Static White)

CodeBeam Angle
NR14°
NM25°
ME35°
WD50°
NH10° x 40°
NV40° x 10°
WH20° x 60°
WV60° x 20°
WP1Wall Wash Pro
WS1Wall Wash Soft

¹ Not compatible with: Internal Accessory Louver (L). Requires: Orientation Angled 15° (W). Recommended: Lens Glare Mask (M).

Beam Angle (Dynamic Colour / Tunable White)

CodeBeam Angle
NR12°
NM20°
ME35°
WD45°
WF55°
WP2Wall Wash Pro
WS2Wall Wash Soft

² Not compatible with: Internal Accessory Louver (L), Lens Glare Mask (M). Requires: Orientation Angled 15° (W).

Internal Accessory

CodeAccessory Type
NNo Accessory
LLouver

¹ Factory fitted accessory. ² Not compatible with: RGBA (4CA), RGBW (4BW) and Tunable White (2WT).

Installation Type

CodeInstallation Type
231Preinstall Blockout¹
262Conduit Mount²

¹ Requires LS6388. Order separately. ² Locks into 4" SCH 40 conduit by others.

Cable Entry

CodeEntry Type
QBottom
NSide

Input Voltage

CodeVoltage Range
0730-48 Vdc (International)
1330-48 Vdc (North America)

Control

CodeControl System
PSPowerSync™¹

¹ Required for all dimming and color-changing applications. LS6540 Data Injector required (order separately).

Orientation

CodeOrientation Type
UVertical Upward
WAngled 15°

Beam Orientation for the NH and WH optical system.

Beam Orientation for the NV and WV optical system.

Trunk Topology

The Trunk Topology is recommended for Above Water Applications, detailing circuit limits for Dimmable and Color-Changing via PowerSync™.

System diagram illustrating the Trunk Topology. It shows a control signal (120 to 277 Vac) feeding a Power Supply (PSU), which then connects to a LV PowerSync Data Injector (LS6550). The Data Injector outputs Vdc + Data via a trunk cable (14 AWG / 2.5 mm²) to multiple luminaires. The diagram specifies maximum total trunk cable length (6' / 1.8m) and cable between luminaires (14 AWG / 2.5 mm²). A PowerSync™ Terminator (T) is shown at the end of the chain.

Important Notes:

Transformer Compatibility Table

Supply Voltage Luminaire Power Max. Leader Cable Length from Power Supply to First Luminaire Maximum Number of Luminaires per Power Supply
120 W 240 W 320 W 480 W 600 W
30 Vdc 9 W 50' (15 m) 10 12 12 12 12
98' (30 m) 10 11 11 11 11
164' (50 m) 9 9 9 9 9
48 Vdc 9 W 50' (15 m) 11 20 23 23 23
98' (30 m) 10 20 20 20 20
164' (50 m) 10 19 19 19 19

Luminaire Wire Colors & Designations

Low Voltage 30 Vdc + PowerSync™:

Designation Color
Positive Red
Negative Black
Data Orange

PDF preview unavailable. Download the PDF instead.

ls3320-2500819 Adobe PDF Library 17.0 Adobe InDesign 20.5 (Windows)

Related Documents

Preview Lumascape ERDEN E2 LS3022 Inground Lighting Installation Guide
Comprehensive installation guide for the Lumascape ERDEN E2 LS3022 inground architectural lighting fixture. Includes safety instructions, component lists, assembly steps, and wiring diagrams for various voltage and market types.
Preview Lumascape ERDEN E4 LS3040 Architectural Luminaire Installation and Safety Guide
Comprehensive guide for the Lumascape ERDEN E4 LS3040 architectural luminaire, covering safety instructions, installation procedures, components, and wiring. Suitable for professional installation.
Preview Lumascape Kololux K6 & K8 Projector & Pendant Installation Guide
Comprehensive installation guide for Lumascape's Kololux K6 and K8 projector and pendant luminaires. Includes safety instructions, tools, components, wiring designations, and installation steps for surface and suspension mounting.
Preview Lumascape pSHM Pendant Luminaire Installation Guide
Comprehensive installation guide for Lumascape pSHM pendant luminaires, covering wiring, transformer selection, and safety precautions. Includes multilingual instructions and circuiting guidelines.
Preview Lumascape UTID Underwater Luminaires: Installation, Circuiting, and Safety Guide
Comprehensive guide for Lumascape UTID underwater luminaires, covering installation, circuiting guidelines, transformer selection, and essential safety precautions for architectural and facade lighting applications.
Preview Lumascape sSHL Surface Luminaires Installation and Safety Guide
Comprehensive guide for installing and safely using Lumascape sSHL surface luminaires, including electrical connection guidelines, transformer usage, and safety precautions.
Preview Lumascape nBLZ In-Grade Luminaires Installation and Safety Guide
Comprehensive installation, circuiting, and safety guidelines for Lumascape's nBLZ In-Grade Luminaires. Learn about voltage requirements, cable management, transformer usage, and essential safety precautions for architectural and facade lighting.
Preview Lumascape FAISCA F3 LS9230 Installation and Safety Guide
Comprehensive installation instructions and safety warnings for the Lumascape FAISCA F3 LS9230 architectural lighting fixture. Covers wiring, mounting, and care for indoor and outdoor use.