EcoFlow PowerOcean Datasheet

EcoFlow PowerOcean (Three-Phase)

Home Solar Battery Solution

The innovative 3-phase solar battery solution starting from 5kWh, expandable at all times. EcoFlow PowerOcean is a premium 3-phase modular home solar solution. With a flexible upfront investment, outstanding safety features, outage backup and super smart control, PowerOcean is designed to achieve power independence for the whole house.

For Installers and Users

For Installers:

For Users:

EcoFlow PowerOcean LFP Battery

Number of Battery Packs EF BD-JC-S1 x 1
EF BD-5.1-S1 x 1
EF BD-B-S1 x 1
EF BD-JC-S1 x 1
EF BD-5.1-S1 x 2
EF BD-B-S1 x 1
EF BD-JC-S1 x 1
EF BD-5.1-S1 x 3
EF BD-B-S1 x 1
Battery Nominal Capacity (kWh) 5.1 10.2 15.3
Battery Usable Capacity (95% Depth of Discharge)* (kWh) 4.8 9.7 14.5
Max. Output Power (W) 3300 6600 9900
Performance Max. Input Power (W) 2500 5000 7500
Nominal Voltage (V) 800
Operating Voltage Range (V) 720-960
Battery Cell Type LFP
Certificates CE MARK
Safety Standard EN62619, EN62040-1, EN62477-1, ISO13849, VDE-AR-E-2510-50
Compliance Delivery Standard UN38.3
EMC EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4
Dimension (W×D×H) (Without Adjustable Feet) (mm) 680×183×612 (±1)
680×183×424 (±1) (EF BD-5.1-S1 x 1)
680×183×1009 (±1) 680×183×1406 (±1)
General Weight (kg) 65.6 120.9 176.2
Installation Floor stand
Operating Temperature (°C) -20 to 50
Max. Operating Altitude (m) 3000
Cooling Method Natural convection
Noise Level (dB) <35
Relative Humidity 0%-100% (Condensing)
Active Aerosol Fire Prevention Module Integrated
Protection Level IP65
Protective Class I

* To maintain optimal battery performance in low-temperature environments, the depth of discharge (DoD) may vary with actual temperature. This is a normal fluctuation.

EcoFlow PowerOcean Hybrid Inverter

Technical parameters EF HD-P3-6K0-S1 EF HD-P3-8K0-S1 EF HD-P3-10K-S1 EF HD-P3-12K-S1
DC Input (PV)
Maximum PV Power (W) 10000 12000 14000 16000
Maximum Input Voltage (V) 1000
MPPT Operating Voltage Range (V) 200-850
Start-Up Voltage (V) 160
Nominal Input Voltage (V) 600
Maximum Power per MPPT (W) 5000 6000 7000 8000
Maximum Input Current per MPPT (A) 16 16 24 24
Maximum Short Circuit Current per MPPT (A) 1 1 2 2
Number of Strings per MPPT 1
Number of MPPTs 2
Overvoltage Category II
DC Input (Battery)
Maximum Charging Power (W) 6000 8000 10000 12000
Maximum Discharging Power (W) 6000 8000 10000 12000
Maximum Continuous Charging Current (A) 12.5 12.5 12.5 15
Maximum Continuous Discharging Current (A) 12.5 12.5 12.5 15
Rated Voltage (V) 800
Maximum Battery Capacity (kWh) 45.9
Connection
Connection 3L+N+PE
Overvoltage Category III
AC Input
Nominal Apparent Power from Utility Grid (VA) 12000 16000 16000 16000
Maximum Apparent Power from Utility Grid (VA) 12000 16000 16000 16000
Rated Input Voltage (V) 230/400, 3L+N+PE
Maximum AC Current from Utility Grid (A) 17.4 23.1 23.1 23.1
Nominal Frequency (Hz) 50/60
Grid Connection 3L+N+PE
AC Output (On-Grid)
Overvoltage Category III
Nominal Apparent Power Output to Utility Grid (VA) 6000 8000 10000 12000
Maximum Apparent Power Output to Utility Grid (VA) 6000 8000 10000 12000
Nominal Output Voltage (V) 230/400, 3L+N+PE
Nominal Frequency (Hz) 50/60
Maximum AC Current Output to Utility Grid (A) 8.7 11.5 14.4 17.4
Nominal Output Current (A) 8.7 11.5 14.4 17.4
Current Total Harmonic Distortion (At Rated Power) <3%
Power Factor 0.8...1...+0.8
AC Output (Parcial Backup)
Nominal Apparent Power (VA) 6000 8000 10000 12000
Maximum Apparent Power (VA) 7200 for 1 sec. 9600 for 1 sec. 12000 for 1 sec. 14400 for 1 sec.
Nominal Output Voltage (V) 230/400, 3L+N+PE
Nominal Frequency (Hz) 50/60
Nominal Output Current (A) 8.7 11.5 14.4 17.4
Maximum Output Current (A) 10.4 for 1 sec. 13.9 for 1 sec. 17.4 for 1 sec. 20.9 for 1 sec.
Voltage Total Harmonic Distortion (At Linear Load & Rated Power) <3%
Protection
Residual Current Monitoring Integrated
PV Insulation Resistance Detection Integrated
Anti-Islanding Protection Integrated
PV Reverse Polarity Protection Integrated
AC Overcurrent Protection Integrated
Backup Load Short-Circuit Protection Integrated
AC Overvoltage Protection Integrated
DC Switch Integrated
Remote Shutdown Integrated
Protective Class I
Efficiency
Maximum Efficiency 97.6%
Maximum MPPT Efficiency 99.9%
Certificates CE/CB/TUV MARK
Safety Standards IEC/EN62109-1, IEC/EN62109-2
Compliance Grid-tied Standards EN 50549, EN50438, TOR Erzeuger Type A, EEA-NE7- CH, PTPiREE, UTE C 15-712-1, ANRE, O3E-323, G99, G98, CEI0-21, C10/11, VDE-AR-N-4105
EMC EN 62311, EN 301 489-1, EN 301 489-17, EN IEC 61000-6-3, EN IEC 61000-3-2, EN 61000-3-3, EN IEC 61000-6-1, EN 300 328
General Data
Topology Non-isolated
Operating Temperature Range (°C) -20 to 50
Storage Temperature (°C) -30 to 60
Operating Relative Humidity 0%-100% (Condensing)
Noise Emission (dB) <35
Maximum Operating Altitude (m) 3000
Weight (kg) Approximately 29.6
Dimensions (W×D×H) (mm) 588×175×380 (±1) (without trim cover), 588×175×455 (±1) (with trim cover)
Protection Level IP65
Self-Consumption at night (W) <25
Cooling Method Natural convection
Communication Method RS485 (for Meter) & CAN (for BMS) & Wi-Fi & Bluetooth & WAN & 4G
Wi-Fi Frequency Range (MHz) 2412-2472 (20) / 2422-2462 (40), 18.54
Maximum Output Power (dBm)
Bluetooth Frequency Range (MHz) 2402-2480, 7.19
Maximum Output Power (dBm)
Pollution Degree PD3
Environmental Category Outdoor/Indoor

Please be advised that EcoFlow reserves the right to modify the design, components, and specifications of its products at any time without prior notice or obligation. The actual product details and final design may vary from those shown or described in this brochure.

PDF preview unavailable. Download the PDF instead.

ecoflow-powerocean-three-phase-datasheet Adobe PDF Library 17.0 Adobe InDesign 18.1 (Windows)

Related Documents

Preview EcoFlow PowerOcean Hybrid Inverter Manufacturer's Declaration for Grid Connection
Manufacturer's declaration from EcoFlow Inc. confirming compliance of the EcoFlow PowerOcean Hybrid Inverter series with the FNN document 'Connection and Operation of Storage Systems to the Low Voltage Grid' (7.1 Juli 2024). Details specific requirements and product model compliance.
Preview EcoFlow PowerOcean Hybrid Inverter User Manual
This user manual provides comprehensive information on the EcoFlow PowerOcean Hybrid Inverter, covering safety instructions, installation, operation, maintenance, technical specifications, and compliance details.
Preview EcoFlow PowerOcean Hybrid Inverter User Manual
Comprehensive user manual for the EcoFlow PowerOcean Hybrid Inverter, covering safety instructions, installation, operation, maintenance, and troubleshooting.
Preview EcoFlow PowerBox (Three-Phase) - Whole-Home Power Backup Solution
Discover the EcoFlow PowerBox (Three-Phase), a manual transfer switch designed for PowerOcean solar battery storage systems, ensuring whole-home power backup and uninterrupted power supply during outages and system maintenance.
Preview EcoFlow PowerBox (3-phasig): Zuverlässige Stromversorgung und Systemintegration
Erfahren Sie mehr über die EcoFlow PowerBox (3-phasig), eine Lösung zur einfachen Hausintegration mit PowerOcean und PowerOcean Plus Systemen für unterbrechungsfreie Stromversorgung.
Preview EcoFlow PowerOcean Hybrid Inverter Manufacturer's Declaration for German Low Voltage Grid Connection
Manufacturer's declaration from EcoFlow Inc. confirming compliance of the PowerOcean Plus Hybrid Inverter series with the FNN document 'Connection and Operation of Storage Systems on the Low Voltage Grid' (July 2024 version). Details requirements for grid connection, energy flow monitoring, and power injection limits.
Preview EcoFlow PowerOcean Plus Hybrid Inverter User Manual | Installation & Operation Guide
Comprehensive user manual for the EcoFlow PowerOcean Plus Hybrid Inverter. Learn about installation, operation, safety, maintenance, troubleshooting, and technical specifications.
Preview EcoFlow PowerOcean Plus Hybrid Inverter User Manual
User manual for the EcoFlow PowerOcean Plus Hybrid Inverter, detailing installation, operation, safety, and maintenance procedures. Covers system overview, LED indicators, network types, and troubleshooting.