Installation Guide for zenitel models including: ZSD-1 Slim Door Intercom, ZSD-1, Slim Door Intercom, Door Intercom, Intercom

[PDF] Z SD-1 Z enitel Slim Door Intercom Mounting & Installation Manual ...

Ensure that all wires are properly arranged around the O-shape when mounting the ZSD-1 onto the back plate. Use the provided M3 x 8mm screw or a screw of.

Mounting and Installation Manual

Zenitel Slim Door intercom (ZSD-1) - Zenitel Wiki


File Info : application/pdf, 2 Pages, 1.01MB

PDF preview unavailable. Download the PDF instead.

A100K12280 ZSD-1 Mounting & Installation Manual v1.3
EN
zenitel.com

ZSD-1 Zenitel Slim Door Intercom Mounting & Installation Manual
A100K12280
v1.3

About
This document serves as a mounting and installation guide for the ZSD-1 Zenitel Slim Door Intercom. For more information and instructions on configuration of the ZSD-1 go to wiki.zenitel.com.

Item Number 1008325010

Item Name ZSD-1

Description Zenitel Slim Door Intercom

Safety Instructions

This manual contains important instructions that must be followed. These instructions are intended to ensure that the product is mounted and installed correctly to avoid equipment damage or property loss. Familiarize yourself with the components and follow the instructions step by step.
A note symbol indicates that extra care must be taken. Damage to equipment can occur, or it may not function as intended. Please read all warnings before installing this product.
Installation should only be carried out by qualified personnel with experience in low-voltage electrical systems. Ensure that the installer is familiar with local electrical codes and regulations.
Make sure that the installation complies with all applicable local, regional, and national regulations regarding electrical installations and low-voltage systems.
After installation, conduct a thorough test of the intercom to ensure proper functionality. Test communication, audio quality, and any additional features according to the provided instructions.
Zenitel takes no responsibility for damages caused by improper or inadequate installation.

ZSD-1 Mounting & Installation Manual

1

Mounting considerations

Check the specification of the product for the installation environment.
Choose a suitable location for the intercom system, try to minimize exposure to water sources, direct sunlight, extreme temperatures, and corrosive substances.

The ZSD-1 must be correctly mounted with the camera positioned on top to maintain the IP rating and ensure proper functionality of the mounting hooks.
Mount the intercom at a height and angle that provide optimal comfort for users during interaction. Consider the natural standing or sitting positions of users and adjust the mounting accordingly. It is recommended to mount the station so that the call button is positioned at a height of approximately 120 cm. This is recommended and necessary to be compliant with accessibility regulations.
Installation
Prior to commencing the installation procedure, deactivate the power supply to both the intercom system and its associated devices. This precautionary measure ensures optimal safety throughout the installation process.
Ensure that all cables are properly routed and secured to prevent tripping hazards or damage. Avoid placing cables near heat sources, sharp edges, or areas where they might be pinched or crushed.
The ZSD-1 must be powered by either PoE or PoE+. This is done by connecting an Ethernet cable to the LAN ports of the station and a PoE switch.
To comply with EMC regulations, the ZSD-1 must be installed with a shielded Ethernet cable with grounding at the switch end.

Zenitel and its subsidiaries assume no responsibility for any errors that may appear in this publication, or for damages arising from the information therein. Zenitel products are developed and marketed by Zenitel. The company's Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001. Zenitel reserves the right to modify designs and alter specifications without notice. ZENITEL PROPRIETARY. This document and its supplementing elements contain Zenitel or third-party information which is proprietary and confidential. Any disclosure, copying, distribution or use is prohibited, if not otherwise explicitly agreed in writing with Zenitel. Any authorized reproduction, in part or in whole, must include this legend: Zenitel ­ All rights reserved.

DOC.NO.: A100K12280 v1.3 customer.service@zenitel.com

ZSD-1 Mounting & Installation Manual

2

Mounting
Have the necessary cables ready before starting the mounting procedure.
1
2 3

1

1

Detach the ZSD-1 from the back plate

Ensure the provided Grommet is securely fitted

2

to the cable hole in the back plate, with the flattest

side facing inward toward the product.

To achieve the IP-66 rating, the provided grommet must be fixed in the hole

Pass the Ethernet cable through the grommet's

3

cable opening. The cable's outer diameter (OD)

should be 4-6mm.

ZSD-1 Mounting & Installation Manual

3 1

2 3

1

Insert the station at the top of the back plate

2

Swing the station into place

3

Secure the ZSD-1 to the back plate using the provided screw

Use the provided M3 x 8mm screw or a screw of the same dimensions. Avoid using screws with a countersunk head.

Nm

Apply a maximum of 0.4Nm torque when

tightening the screw

ZSD-1 Mounting & Installation Manual

2 1

175 mm
2

COM NO NC

1
29 mm

1

Securely mount the bracket at the chosen

location. Use 3-4mm screws.

2

Plug the Ethernet cable into the LAN port.

Terminate all other wires according to the planned system setup.
Ensure that all wires are properly arranged around the O-shape when mounting the ZSD-1 onto the back plate.

3
Configuration
When the ZSD-1 is connected to the network, its IP address is automatically obtained from a DHCP server or an IP adress in the range 169.254.xx will be assigned.
To prompt the station to announce its IP address, simply press the Call Button located on the station.
The ZSD-1 is capable of operating in various modes, including IC-EDGE, ICX-AlphaCom, and SIP. To register with Zenitel Connect Pro the ZSD-1 must be in factory default mode. Setup and configuration will be managed through Zenitel Connect Pro. Enter the link or scan the QR-code to go to Zenitel Wiki for configuration instructions.
Zenitel Wiki: wiki.zenitel.com
Zentel hereby declares that this product is in compliance with the essential requirements and other relevant procisions of deirective 2014/53/EU and all other applicable EU directive requirements. The complete declaration can be found at www.zenitel.com.
The WEEE Directive does not legislate that Zenitel, as a `producer', shall collect `end of life' WEEE. This `end of life' WEEE should be recycled appropriately by the owner who should use proper treatment and recycling measures. It should not be disposed to landfill. Many electrical items that we throw away can be repaired or recycled. Recycling items helps to save our natural finite resources and also reduces the environmental and health risks associated with sending electrical goods to landfill. Under the WEEE Regulations, all new electrical goods should now be marked with the crossed-out wheeled bin symbol shown. Goods are marked with this symbol to show that they were produced after 13th August 2005, and should be disposed of separately from normal household waste so that they can be recycled.
4



References

Adobe PDF Library 17.0 Adobe InDesign 20.2 (Windows)