Occupancy & Vacancy Sensors & Timers Technology

Passive Infrared Sensors (PIR)

Using a patented fresnel lens that minimizes optical aberrations, each Legrand/Pass & Seymour PIR sensor divides its coverage area into zones. When an infrared energy change is detected within a zone, one element of the dual-element pyroelectric sensing device generates a positive pulse. Within milliseconds, the other element produces a negative pulse, turning the lights on. Vacancy sensors turn lights off when the room is vacant for a period or when no infrared energy is detected.

Passive infrared sensors are less effective at detecting occupancy around barriers and are more effective when sensing movement across their field of sight rather than towards or away from it.

Features:

  • Patented fresnel lenses with multi-segment design
  • Dual-element pyroelectric sensors
  • Low-profile design
  • Daylight filter systems
  • Adjustable settings for time and sensitivity
  • Custom Detection Signature Analysis for high immunity to RFI and EMI, and reliability
  • Self-adaptive technology is available on some models

Ultrasonic Sensors

Ultrasonic sensors utilize a multi-directional transmitter/receiver system to broadcast ultrasonic sound waves generated by a quartz crystal oscillator. They measure the time it takes for these waves to return. Movement within the area causes the sound waves to return at a different rate, thus detecting occupancy.

Ultrasonic sensors broadcast in three dimensions, enabling detection of smaller movements than PIR sensors. Proper placement is crucial, as sound waves can escape through open doorways, leading to false triggering. While Legrand/Pass & Seymour ultrasonic sensors include circuitry to filter out air-flow movement from HVAC equipment or fans, sensors should be kept away from breezy areas. Heavy carpeting and other sound-absorbing materials can also reduce coverage.

Features:

  • Temperature- and humidity-resistant tuned receivers
  • Signal Processing Circuitry
  • Solid-state, crystal-controlled transmitter
  • Adjustable controls for time and sensitivity

Dual Technology

Dual Technology sensors combine PIR and Ultrasonic sensing in one device to minimize false ONs and nuisance OFFs. Adjustable sensitivity and user-selectable operational characteristics make these sensors versatile for demanding applications, including odd-shaped rooms, areas with partitions, and changing floor plans.

Applications Overview

P&S ModelCatalog Page #Best Suited For:
RW500UL-5Storage rooms, walk-in closets, pantries, garage where no neutral is available
RWU600UL-5Storage rooms, walk-in closets, pantries, garage where a neutral is available
RW500BL-4Bedrooms, basements bathrooms, laundry rooms, where no neutral is available
RWU600BL-4Bedrooms, basements bathrooms, laundry rooms, where a neutral is available
RW600BTCL-4Bedrooms, basements bathrooms, laundry rooms, where no neutral is available
RW3U600L-6Any room/hall with multiple entrances -- allows manual ON/OFF control from both locations. Can be switched between occupancy and vacancy.
RW3U603L-6T24 Compliant. Any room/hall with multiple entrances -- allows manual ON/OFF control from both locations. Can be switched between occupancy and vacancy.
RWDU500L-7Any room where adjustable light level is desired
PTWSP250L-8Small offices, closets, utility rooms with no partitions or obstructions
WSP250L-8Small offices, closets, utility rooms with no partitions or obstructions
OS300SL-10Small offices, closets, small conference rooms with no partitions or obstructions
OSR300SL-11Small rooms with two individually-controlled loads or bi-level lighting with no partitions or obstructions
WDT100L-9Small offices, executive suites, conference rooms, break rooms.
WDT200L-9
CS500L-13Open offices, lunch, utility, storage, and computer rooms with no partitions or obstructions
CS1200L-13Larger rooms, up to 1200 sq. ft., with open floor plans, no partitions or obstructions
HS1001L-12Hallways, or aisles
WA1001L-12Entrances, vestibules, classrooms, for wide-angle applications
CSU600L-14Offices, computer, meeting, copy, and restrooms
CSU1100L-14Offices, lunch, break and classrooms, restrooms, and conference rooms
CSU2200L-14Offices, lunch, break and classrooms, restrooms, conference rooms, halls, storage areas
CSD1000L-15Meeting, conference and classrooms, restrooms, dressing rooms, libraries, interview rooms, testing areas, lunch and break rooms
RT1L-18Closets, bathroom fans, exhaust fans, heat lamps, bedrooms
RT12L-19Garages, basements, laundry rooms, fans, motors, landscape lights
RT24L-19Exterior lights, landscape lighting, security lighting, holiday lighting
97015, 30, 60L-20Bathroom fans, heat lamps, guest rooms
97115, 30, 60L-20Bathroom fans, heat lamps, guest rooms where a hold function is desired
97352L-20Dual control for bathroom light and fan

Residential Occupancy Sensors - Passive Infrared (PIR)

Features:

  • Replaces a standard light or fan single pole switch.
  • Lighted switch for visibility in darkened rooms.
  • Automatic-ON operation.
  • Fixed five-minute time delay.
  • Low-profile styling with uniform color-matched lens and device.
  • Coverage: 180°, max. 600 ft.² (56m²)
  • cULus listed.
  • 5-year warranty.
  • Works with most common residential lighting types (RWU600U only).
  • Load: Incandescent, fluorescent, compact fluorescent (CFL), magnetic low-voltage (MLV) and electronic low-voltage (ELV), 1/6 hp.

Single Pole Occupancy Sensors

Catalog NumberDescriptionVoltageLoadSelectable Auto ONManual ONAuto/Man ONColor
RW500UICC4No neutral required, ideal for storage and utility rooms120VAC 60 Hz25-500W IncandescentYesNoNoIvory
RW500UWCC4120VAC 60 Hz25-500W IncandescentYesNoNoWhite
RW500UBKCC4120VAC 60 Hz25-500W IncandescentYesNoNoBlack
RW500ULACC4120VAC 60 Hz25-500W IncandescentYesNoNoLt. Almond
RWU600UICC4Neutral required, controls most types of lighting, ideal for storage & utility rooms120VAC 60 Hz0-600W AllYesNoNoIvory
RWU600UWCC4120VAC 60 Hz0-600W AllYesNoNoWhite
RWU600UBKCC4120VAC 60 Hz0-600W AllYesNoNoBlack
RWU600ULACC4120VAC 60 Hz0-600W AllYesNoNoLt. Almond

Diagram Descriptions:

Coverage Diagram

Illustrates the sensor's coverage pattern, showing a 180-degree field of view with a maximum range of 25 feet (7.6m) at the widest point, and a range of 4 feet (1.2m) at the closest point. The coverage area is approximately 600 square feet (56m²).

Wiring Diagrams

RW500U Wiring: Depicts a three-wire connection: Black wire for HOT (power from circuit box), Red wire for LOAD (power to lamp or fan), and Green wire for GROUND. This model does not require a neutral wire.

RWU600U Wiring: Depicts a four-wire connection: Black wire for HOT (power from circuit box), Red wire for LOAD (power to lamp or fan), White wire for NEUTRAL, and Green wire for GROUND. This model requires a neutral wire.

All devices listed on this page conform to NEMA WD-1 and WD-6 standards.

PDF preview unavailable. Download the PDF instead.

PASSEME07915 L2 L3 L5 Adobe InDesign CS4 (6.0.5) Adobe PDF Library 9.0

Related Documents

Preview Legrand PTDSW301 Dual Technology Wall Switch Occupancy Sensor Installation and Operation Guide
This document provides installation instructions, operation details, specifications, and troubleshooting tips for the Legrand PTDSW301 PlugTail Dual Technology Wall Switch Occupancy Sensor. It covers features like PIR and ultrasonic detection, adjustable sensitivity, time delays, and light level control.
Preview Legrand Presence Sensors for Working Areas with Natural Light
Explore Legrand's advanced presence and lighting management sensors for diverse working environments. This document details ceiling-mounting PIR, ultrasonic, and dual-technology sensors designed for small spaces, large areas, and offices, offering features like DALI and 1-10V dimming. Find technical specifications, catalog numbers, and application suitability.
Preview Legrand DW-311 Dual Technology Dimming Wall Switch Sensor
The Legrand DW-311 is a dual technology dimming wall switch sensor that controls lighting loads, including LEDs, using PIR and ultrasonic detection. It offers features like adjustable time delay, multi-way control, and selectable Manual-ON operation for energy savings.
Preview Wattstopper DW-311/DW-311-347 Dual Technology Occupancy Sensor Installation Guide
Comprehensive installation guide for Wattstopper DW-311 and DW-311-347 Dual Technology 0-10 Volt Wall Switch Occupancy Sensors. Covers features, specifications, wiring, setup, multi-way functionality, advanced settings, and troubleshooting.
Preview Legrand DALI Light Up Multi-Sensor: Advanced 3-Zone Occupancy and Environmental Sensing
Comprehensive guide to the Legrand DALI Light Up multi-sensor, detailing its features, technical specifications, installation, wiring, and usage with the 'CLOSE UP' mobile app for advanced lighting control and building management.
Preview Wattstopper LMDC-100 DLM Dual Technology Occupancy Sensor | Quick Start Guide
Quick start guide for the Wattstopper LMDC-100 DLM Dual Technology Ceiling Mount Occupancy Sensor. Provides specifications, installation, connectivity, mounting, pre-set operations, and troubleshooting information.
Preview Legrand DALI Light Up Multi-Sensor Detector User Manual
Comprehensive guide to the Legrand DALI Light Up multi-sensor detector, covering its features, technical specifications, installation, wiring, and usage with the CLOSE UP app. Learn about its various sensors for presence, light, temperature, humidity, acoustics, and air quality.
Preview Wattstopper DW-311/DW-311-347 Dual Technology Wall Switch Occupancy Sensor Installation Instructions
This document provides detailed installation instructions for the Wattstopper DW-311 and DW-311-347 Dual Technology Wall Switch Occupancy Sensors. It covers wiring, setup, features, and troubleshooting for these advanced PIR and ultrasonic sensors.