Thank you for purchasing this network camera! This owner's manual is designed to be a reference tool for your system. Please read this manual carefully before operating the unit and retain it for future reference. Should you require any technical assistance, contact Speco Technologies Tech Support at 1-800-645-5516.
Important Safeguards and Warning
1. Electrical safety
All installation and operation here should conform to local electrical safety codes. Use a certified/listed 12VDC Class 2 power supply only. Please note: Do not connect two power supplying sources to the device at the same time; it may result in device damage! The product must be grounded to reduce the risk of electric shock. Improper handling and/or installation could run the risk of fire or electrical shock.
2. Environment
Heavy stress, violent vibration or exposure to water is not allowed during transportation, storage and installation. This product should be installed in a cool, dry place away from direct sunlight and heat sources. Do not install the product in extreme temperature conditions. Do not expose the camera to electromagnetic radiation. Otherwise it may result in CMOS sensor failure. Do not block any ventilation openings. Do not allow water and liquid intrusion into the camera.
3. Operation and Daily Maintenance
Please shut down the device and then unplug the power cable before you begin any maintenance work. Do not touch the CMOS sensor optic component. You can use a blower to clean the dust on the lens surface. Always use the dry soft cloth to clean the device. If there is too much dust, use a cloth dampened with a small quantity of neutral detergent. Finally use the dry cloth to clean the device.
Please use a professional optical cleaning method to clean the enclosure. Improper enclosure cleaning (such as using cloth) may result in poor IR functionality and/or IR reflection. The grounding holes of the product are recommended to be grounded to further enhance the reliability of the camera. Dome cover is an optical device, please don't touch or wipe cover surface directly during installation and use, please refer to the following methods if dirt is found: Stained with dirt: Use oil-free soft brush or hair dryer to remove it gently. Stained with grease or fingerprint: Use oil-free cotton cloth or paper soaked with alcohol or detergent to wipe from the lens center outward. Change the cloth and wipe several times if it is not clean enough.
Warning
This camera should be installed by qualified personnel only. All the examination and repair work should be done by qualified personnel. Any unauthorized changes or modifications could void the warranty. This device may potentially trigger seizures for people with photosensitive epilepsy. This device may emit loud audible alarms, check your local laws before enabling audio.
Statement
This guide is for reference only. Product, manuals and specifications may be modified without prior notice. Speco Technologies reserves the right to modify these without notice and without incurring any obligation. Speco Technologies is not liable for any loss caused by improper operation.
Note:
Before installation, check the package and make sure that all components are included. Contact your rep or Speco customer service department immediately if something is broken or missing in the package.
1 Package
Diagram illustrating package contents: Camera, Quick start guide, Tapping screws (x4), Drill template, CD, Screwdriver, Rubber plug, Plastic plugs (x4), Junction box.
2 Overview
Diagram of the Speco Technologies 04TDD1M camera, highlighting connection ports and features: 1. Ethernet connector, 2. Audio input connector, 3. Alarm input/output, 4. Power connector, 5. Speaker, 6. Microphone, 7. Micro SD card slot, 8. Reset button.
Wiring and Connections
Diagram showing the camera's wiring harness, including a water-proof connector and DC12V power input. Alarm connection terminals are labeled: 1--ALARM-COM, 2--ALARM_OPEN, 3--ALARM_INA, 4--ALARM_GND.
* 1 It is recommended to install the water-proof connector for outdoor installations. * 2 DC 12V power supply is not required if a PoE switch or injector is used to power the camera.
Connecting Network Cable
Diagram sequence illustrating the connection of a network cable: Step 1 shows loosening a nut. Step 2 shows threading a network cable through connector elements and crimping an RJ45 connector. Step 3 shows connecting the cable to the water-proof connector and tightening.
3 Installation
* Before you start, please make sure that the wall or ceiling is strong enough to withstand three times the weight of the camera and the junction box.
Step 1: Prepare Junction Box
Diagram showing the junction box components: Mounting base and Upper cover.
Step 2: Mount Junction Box
Diagram illustrating the installation of the junction box onto a surface using screws.
Step 3: Insert Micro SD Card
Diagram showing the camera's enclosure being opened by loosening a fixed screw to access the Micro SD card slot. The dome cover is removed to insert the card, then reattached.
Step 4: Mount Camera to Junction Box
Diagram showing the camera's mounting base being attached to the junction box, with a rubber plug securing the connection.
Step 5: Route and Connect Cables
Route the cables through the cable hole and connect the cables. Then reinstall the upper cover onto the junction box.
Step 6: Adjust Camera Angle
Diagram illustrating the final camera adjustment for optimal angle, with a fixed screw indicated for tightening.
4 Web Operation and Login
IP Scanner can search for the device on the local network.
Operation Steps:
- Make sure that the camera and the PC are connected to the same local network. The camera is set to DHCP by default.
- Install IP Scanner from the CD and run it after installation. Or download from https://www.specotech.com/ip-scanner/.
Screenshot of the Speco Technologies SecureGuard IP Scanner software, displaying a list of network devices with their IP addresses, model names (including 04TDD1), and MAC addresses.
In the device list, you can view the IP address, model number, and MAC address of each device. Select the applicable device and double click to open up the web viewer. You can also manually enter the IP address in the address bar of the web browser.
Screenshot of the Speco Technologies login page for the camera's web interface, featuring fields for Username and Password.
The login interface is shown above. Default user name is admin and password is 1234. After logging in, follow directions to install applicable plugins if prompted.