Hyundai Premium 100W Flexible Cordless Vacuum
User Manual
Model: HHA322418
Safety Instructions
For your own safety when using an electrical appliance, please follow basic safety precautions:
- Follow all instructions carefully when assembling and using this product.
- Never leave the charger on or plugged in for prolonged periods of time when not in use. Always unplug before servicing.
- For indoor use only.
- Do not use the 3-in-1 Handheld Cordless Vacuum if the charger or battery are damaged.
- Do not use this product without the dust container and filter in place.
- Do not handle the plug, charger or appliance with wet hands.
- Do not operate this vacuum for extended periods of time near heat sources such as fires, radiators, heaters, lit cigarettes etc.
- This product features a thermal safety cut-out device. Should the vacuum overheat, power will instantly be stopped. In this event, the device should be switched off, and left to cool completely before attempting to use again.
- Ensure the appliance is completely switched OFF via the main body and at the socket before removing from the battery charger. Do not overstretch the charging cable.
- Do not submerge any part of the appliance in water.
- When removing the charger plug from the mains supply, do so from the plug itself and not by the means of the cord.
- Ensure that all vents and openings are kept clear of dust, lint, hair and anything that may reduce airflow. A clogged vent may cause the product to overheat.
- Ensure that hair, loose clothing, fingers and all parts of body are kept away from the openings and moving parts of the vacuum.
- This product uses a lithium-ion battery. Waste batteries should be safely recycled where possible.
- The appliance is only to be used with the battery provided in conjunction with the supplied charger.
- Store battery away from high temperatures.
- Do not pierce, or attempt to open the battery under any circumstances.
- In the event of a leaking battery, ensure that acid stays away from skin and eyes. If acid comes into contact with skin, rinse with clean, fresh water and seek medical advice. If acid comes into contact with eyes, rinse with clean fresh water and seek medical attention immediately.
- Extra care must be taken when cleaning on the stairs.
- Ensure the appliance is turned off before connecting any accessories.
- Not suitable for use on liquids or wet surfaces.
- Not suitable for vacuuming burning or smoking items, such as cigarettes, matches or hot ashes.
- Do not leave this product for extended periods of time in direct sunlight.
- Any person using this product should be fully aware of the hazards involved. A responsible adult should always ensure the product is used under supervision or that adequate instruction has been given to adults with reduced physical, mental or sensory capabilities, or anyone with a lack of experience using a similar product. This product is not a toy. Children under 16 should be supervised to ensure that they do not play with this vacuum cleaner.
- If appliance needs repairing, this must be done by a qualified professional or electrician to avoid injury or further damage to the product.
- Return to retailer if defects are found before use.
Part Description
The vacuum cleaner includes the following parts:
- 1. Floor head
- 2. Floor head release button
- 3. Crevice nozzle
- 4. Dusting nozzle
- 5. Extension tube release button
- 6. Dust container release button
- 7. Power adjustment key
- 8. Power maintenance lights
- 9. ON/OFF button
- 19. Floor brush roller
- 10. Battery release button
- 11. Dust release button
- 12. Accessory hook
- 13. Foldable tube
- 14. Battery
- 15. Wall mount
- 16. Screws
- 17. Charger
- 18. Filter
Precautions
Important: If the suction opening in the unit or the hose is blocked, switch off the vacuum cleaner and remove the blocking substance before you start the unit again.
- Do not operate the vacuum cleaner too close to heaters, radiators or cigarette butts.
- Before inserting the power plug into the wall outlet, make sure that your hands are dry.
- Before you start vacuuming, make sure to remove large or sharp objects that might damage the dust cup filter.
- When pulling out the power plug from the wall outlet, pull the plug, not the power cord.
- Do not pick up anything that is burning or smoking such as cigarettes, matches or hot ashes.
- Do not use without dust cup filter in place.
Assembly Instructions
NOTE: Before assembling the appliance, fix the included mount to the wall. Ensure it is placed high enough for the vacuum to be securely mounted.
Assembling the Main Body:
1. Install the battery into the housing by sliding it into the appropriate slot. It will 'click' into place.
2. Install the dust container by inserting the clip into the main body, then twisting into place. It will 'click' to secure.
3. This completes the main body assembly.
4. Attach the dusting nozzle to the extension tube or the main body, similar to attaching the crevice nozzle.
Assembling with the Motor-Driven Floor Head:
1. Insert the connector of the motor-driven floor head into the base of the extension tube by clicking it into place.
2. Attach the floor head and tube to the main body by slotting them into place via the air duct connector.
3. If using the floor head without the tube, simply attach it to the main body via the air duct connector. It will 'click' when secure.
Assembling with an Accessory:
1. Attach the extension tube to the main body by slotting it into place via the duct connector.
2. Attach the crevice nozzle to the base of the extension tube via the connector. It will 'click' into place.
3. If using accessories without the tube, simply attach them to the main body via the air duct connector. It will 'click' when secure.
Before First Use
- Mount the unit to the wall bracket.
- Ensure that the air vent and suction pipe are free from blockages and dust. Should they suddenly become clogged, switch off the appliance immediately and clear the blockage before attempting to use the vacuum again.
- Remove any sharp or large objects from the path of the vacuum before using, as these may irreparably damage the appliance.
NOTE: In the event of a maintenance issue with the product, such as a jammed brush roll, all three BLUE indicator lights will flash on and off until the issue is resolved. In this case, turn the cleaner off until the issue is rectified.
Battery Charging
A. Push the release button and take the battery module out.
Plug the cable into the power inlet located on the side of the battery. When charging, the energy indicator light will be illuminated RED. Once fully charged, this indicator light will change to GREEN. Indicator lights may turn off when fully charged. Once fully charged, unplug the charger from the power socket.
B. You can also change the battery in the main body directly. The three lights in the top of the body will indicate the state of the battery. When the battery is fully charged, all three lights will keep bright in green.
Operating the Vacuum
CAUTION: The vacuum must be fully charged before using for the first time.
- Remove the vacuum cleaner from the wall mount. If using as a handheld unit, disassemble the tube and attach the desired accessory.
- Use the Power ON/OFF button to turn on the appliance.
- For stronger suction, press the Power adjustment key to increase the strength. This is ideal for cleaning carpets with a high pile.
- To turn off the vacuum, press the Power ON/OFF button again.
Maintaining the Vacuum
Cleaning the Dust Container:
1. Press the dust container release button and disassemble the unit so only the main body remains.
2. Unclip the dust container from the main body.
3. Over a waste bin, press the dust release button to open the bottom cover and expel any dust, dirt, and debris. Wipe clean only; do not submerge in water.
Cleaning the Filter:
1. Remove the dust container from the main body.
2. Twist the lid of the dust container anti-clockwise to open.
3. Remove the sponge inlet filter from the top of the dust container.
4. Rinse thoroughly under clean, fresh water. Do not use soap or other cleaning agents.
5. Allow the filter to dry naturally before placing it back into the vacuum. Do not place on radiators or use additional appliances, such as a hair dryer, to dry the filter, as this may cause the filter to warp or suffer other irreparable damage.
Cleaning the Brush Roll:
1. Slide the brush roll securing catch "A" away from the brush as indicated in the illustration.
2. Remove the brush roll from the brush housing.
3. Carefully clean and remove any hairs and fibres from the brush roll. Wipe clean only; do not use any soap or harsh cleaning agents.
4. If the brush roll becomes damp during cleaning, allow it to dry naturally before replacing the brush roll back into the housing.
5. Slide securing catch "A" back into its original position to secure the brush roll.
Troubleshooting
The appliance will not power on: This may be caused by a flat battery. This can occur if the appliance has been used or stored for an extended period of time. Connect the vacuum to the charger and allow for a full charging cycle to complete.
The vacuum stopped suddenly: This will occur if the safety cut-out device has been activated. This device is designed to prevent your appliance from overheating. Ensure the vacuum is turned off, disconnect all accessories, and leave to cool down for at least half an hour before attempting to operate again. Try to identify the source of the overheat by checking for blockages in the extension tube, motor-driven floor head, and accessories. Empty the dust container and clean or replace the filter.
The suction of the vacuum has reduced: Turn the vacuum off. Disconnect the floor head, extension tube, and any accessories. Check for and remove any blockages from the dustbin filter, air duct, extension tube, floor head, and accessories.
Motorised floor head is not rotating: This tends to occur when there are too many fibres wrapped around the brush roll, restricting movement. Consult the maintenance section of this manual for instructions on how to appropriately clean the brush roll.
The charging indicator light does not flash red: There may be no power reaching the vacuum from the charger. Ensure that power is being supplied to the mains socket and that the charger is turned on. Ensure the charging cable is securely connected to the vacuum. Ensure the mains socket is switched off before checking the charging cable itself. Do not attempt to use if the cable is split, frayed, or otherwise damaged. Instead, seek a replacement charger.
The application time of the vacuum is less than it used to be: Ensure the battery has completed a full charging cycle. An insufficient charging cycle will result in reduced application time. There may be reduced energy discharge in the battery. This is normal and gradually occurs in all batteries over time.
Technical Specifications
Specification | Details |
---|---|
Power | 100 Watt (Brush motor) |
Battery Type | 2200mAh Lithium Ion |
Battery Voltage | 22.2V |
Detachable battery | Yes |
Output | 26.5VDC 0.75A |
Approximate charge time | 3 hours |
2 suction speeds | 4000Pa (40 minutes running time) 7500Pa (25 minutes running time) |
Tube | Aluminium tube (Foldable) |
Filtration | Microfiber filter |
Dust capacity | 0.5 Liter |
Brush | Motorized brush with LED lights |
Suction Accessories | 2-in-1 upholstery nozzle, crevice nozzle & accessory holder |
Wall Mount design | Yes |