Introduction

Thank you for purchasing an EyeMobile Plus device from Tobii Dynavox! To ensure the optimal performance of this product, please take the time to read this manual carefully.

1.1 Explanation of Admonitions

In this manual we use four (4) levels of admonitions:

1.2 Intended Use

The EyeMobile Plus is an integrated mobile solution featuring a built-in Eye tracker, IR, switches, microphone array, battery, great speakers, and a Windows tablet. It is designed for use as an always-connected computer access solution or as a Speech Generating solution, enabling users to interact with the world.

The EyeMobile Plus allows users to access and control their Windows Tablet using their eyes. Users can select commands by dwelling, zooming, or clicking a switch, or fully control the mouse cursor with eye movements.

It is intended for use with Windows Control for Augmentative and Alternative Communication (AAC) and for computer access purposes as an alternative input device for individuals with challenges in speaking or computer access due to injury, disability, or illness.

Beyond its primary eye-tracking function, the EyeMobile Plus includes a microphone array for speech recognition and dictation, switch ports for users with limited mobility, and infrared transmission capabilities for environmental control (e.g., controlling televisions, music devices, windows). It also supports Microsoft Windows Hello for biometric facial recognition login.

The device is primarily operated by the user's eyes after calibration to their specific eye movements. Its purpose is to enable computer control, not for the control of medical devices. The EyeMobile Plus provides a fast, accurate, and hands-free method for users to access computer-based resources, fostering personal independence, education, work, social connection, and creative expression.

Figure 1.1: The Tobii Dynavox EyeMobile Plus device, shown mounted on a stand with its screen displaying an interface. The eye-tracking module is positioned below the screen.

[Warning] Do not cover the front of the EyeMobile Plus in any way (with decorations, Post-Its, etc.) as Windows Control will be compromised.

[Note] Using an antivirus program is strongly recommended.

1.3 Package Contents

[Warning] Only use the items included in the EyeMobile Plus package, those described in the product documentation, and other approved Tobii Dynavox Accessories in conjunction with the EyeMobile Plus.

Safety

The EyeMobile Plus device has been tested and approved as compliant with relevant specifications and standards. However, to ensure safe operation, please bear the following safety warnings in mind:

2.1 Avoiding Hearing Damage

Permanent hearing loss can occur if earphones, headphones, or speakers are used at high volume. To prevent this, set the volume to a safe level. Prolonged exposure to high sound levels can desensitize hearing, making them seem acceptable while still causing damage. If you experience symptoms like ringing in your ears, lower the volume or stop using the audio devices. The louder the volume, the less time is required before hearing could be affected.

Hearing experts suggest the following measures to protect your hearing:

To establish a safe volume level:

2.2 Power Supply and Batteries

The EyeMobile Plus contains a rechargeable battery that degrades over time, potentially reducing usage time after a full charge. It uses a Li-ion Polymer battery.

[Warning] If operating in a hot environment, be aware that it can affect battery charging. The internal temperature must be between 0°C (32°F) and 45°C (113°F) for the battery to charge. If the internal battery temperature exceeds 45°C (113°F), the battery will not charge. Move the device to a cooler environment to allow proper charging.

[Warning] Avoid exposing the EyeMobile Plus to fire or temperatures above 60°C (140°F), as these conditions may cause the battery to malfunction, generate heat, ignite, or explode. Storing the device in a hot car trunk, for example, could lead to a malfunction.

[Warning] Only charge the EyeMobile Plus battery in an ambient temperature of 0°C (32°F) to 45°C (113°F).

[Warning] Use only the supplied power adapter to charge the EyeMobile Plus device. Using unauthorized power adapters may severely damage the device.

[Warning] For safe operation, use only chargers and accessories approved by Tobii Dynavox.

[Warning] Do not open or modify the casing of the EyeMobile Plus device or the power supply, as you may be exposed to hazardous electrical voltage. The device contains no user-serviceable parts. If the device or its accessories are mechanically damaged, do not use them.

[Warning] If the battery is not charged and the device is not connected to the power supply, it will shut down.

[Warning] If the Power Supply Cord is damaged, it must be replaced by Service Personnel only. Do not use the cord until replaced.

[Warning] Special regulations apply to shipping devices containing Li-ion Polymer batteries. If dropped, crushed, or short-circuited, these batteries can release dangerous amounts of heat, ignite, and are dangerous in fires. Please reference IATA regulations when shipping lithium metal or lithium ion batteries or cells: www.iata.org/whatwedo/cargo/dangerous_goods/Pages/lithium_batteries.aspx

[Warning] Power adapters shall not be used without adult or caregiver supervision.

2.3 Mounting

The EyeMobile Plus should be mounted according to the instructions of the approved mounts used. Tobii Dynavox or its agents are not liable for damage or injuries to a person or property due to the EyeMobile Plus falling from a mounted configuration. Mounting is done entirely at the user's own risk.

2.4 Epilepsy Warning

Some individuals with Photosensitive Epilepsy are susceptible to epileptic seizures or loss of consciousness when exposed to certain flashing lights or light patterns. This can occur even if they have no prior medical history of epilepsy. Such individuals may also experience issues with TV screens, arcade games, and flickering fluorescent bulbs. Seizures can be triggered by specific images or patterns on a monitor, or even by the light sources of an eye tracker. It is estimated that 3-5% of people with epilepsy have this type of Photosensitive Epilepsy. Many experience an "aura" or odd sensations before a seizure. If you feel odd during use, move your eyes away from the eye tracker.

2.5 Infrared Warning

[Warning] When activated, the EyeMobile Plus emits pulsed infrared (IR) light. Certain medical devices may be susceptible to disturbance by IR light and/or radiation. Do not use the EyeMobile Plus in the vicinity of such susceptible medical devices, as their accuracy or proper functionality could be inhibited.

2.6 Magnetic Field Warning

[Warning] The EyeMobile Plus Magnetic Mounting contains magnets. Magnetic fields may interfere with the function of cardiac pacemakers and implantable cardioverter-defibrillators. As a general rule, maintain a minimum distance of 6 inches (15 centimeters) between any item with magnets and your heart device.

2.7 Child Safety

The EyeMobile Plus is an advanced computer system. It is composed of numerous separate parts. In the hands of a child, certain parts may separate from the device, potentially constituting a choking hazard or other danger. Young children should not have access to or use the device without parental or guardian supervision.

2.8 Do not open EyeMobile Plus

[Warning] Non-compliance will result in loss of Warranty! There are no user-serviceable components inside. Contact Tobii Dynavox Support if your EyeMobile Plus is not working properly.

2.9 Emergency

[Warning] Do not rely on the device for emergency calls or banking transactions. We recommend having multiple ways to communicate in emergency situations. Banking transactions should only be carried out with a system recommended by, and approved according to the standards of, your bank.

2.10 Windows Control

Some people may experience fatigue (due to intentional eye focusing and hard concentration) or eye dryness (due to less frequent blinking) when first using Windows Control. If you experience fatigue or dry eyes, start slowly and limit your Windows Control sessions to your comfort level. Remoisturizing eye drops can be helpful.

2.11 Third Party

[Warning] Any use of the EyeMobile Plus outside its intended use, or with third-party software or hardware that changes its intended use, is a risk for which Tobii Dynavox cannot take responsibility.

2.12 Environmental Control

[Warning] The Programmable IR Remote Control (Environmental Control Unit) is not to be relied on as the sole method of interaction with IR-controlled devices.

Getting Started with EyeMobile Plus

3.1 Requirements

For EyeMobile Plus, the following minimum system requirements are recommended:

Component Requirements
Computer and processor 2.0 gigahertz (GHz) or faster, Dual-Core processor (recommended minimum).
Memory (RAM) 4 gigabyte (GB) RAM (recommended minimum).
Hard Disk 450 megabytes (MB) available
USB USB 2.0
Operating System
  • Windows 7 (64-bit)
  • Windows 8.1 (32-bit or 64-bit)
  • Windows 10 (32-bit or 64-bit)
.NET version 4.5
Tobii Eye Tracking Core Software Version 2.8 or later

[Note] To use the EyeMobile Plus, one of the following Tobii Dynavox software must be installed:

3.2 Overview

Figure 3.1: Front and back views of the EyeMobile Plus device with numbered components.

Key components of the EyeMobile Plus:

[Warning] Never force a connector into a port. If the connector and port do not join with reasonable ease, they probably do not match. Make sure that the connector matches the port and that you have positioned the connector correctly in relation to the port.

[Warning] Be extra careful with the USB connectors.

Batteries in the EyeMobile Plus

4.1 Batteries

The EyeMobile Plus has one built-in battery. Microsoft Windows provides battery warnings. If the device is not charged or powered by the power supply, it will shut down automatically. For more information, refer to Appendix C Technical Specifications, page 21.

4.2 Charging the EyeMobile Plus

  1. Connect the Power cable to the Power Connector on the device.
  2. Connect the Power adapter to an electrical outlet and charge the tablet until the battery is fully charged.

If the battery charging level drops below 5%, the EyeMobile Plus will be charged via the USB connection to the tablet until the battery reaches 10% of its charging level. This ensures the tablet and EyeMobile Plus run out of battery simultaneously.

For battery storage and charging temperatures, see Section 2 Safety, page 7.

4.2.1 Checking Charge Level

To check the battery charge level of the EyeMobile Plus, use the battery monitor within Windows 10.

4.2.2 Power LED Behavior

The Power LED indicates the charge status with multiple colors:

LED state Connection Charge status
Solid green USB & AC Fully charged
Flashing green USB & AC Charging from AC
Solid purple USB only Not charging (>10%)
Flashing purple USB only Charging from USB (<5%)
Solid Orange AC only Fully charged
Flashing Orange AC only Charging from AC
Solid red Unknown/Error Unknown/Error
Off Not connected N/A

Using EyeMobile Plus

5.1 Positioning the User

Figure 5.1: Illustration showing optimal eye-to-screen distance and alignment.

The EyeMobile Plus is designed to work optimally when it is parallel to the user's eyes at a distance of approximately 45-85 cm (18 to 33 inches), as shown in Figure 5.1 and Figure 5.2.

Figure 5.2: Illustration showing optimal eye-to-screen distance and alignment for users leaning sideways or lying down.

For users leaning sideways or lying down, the EyeMobile Plus needs to be tilted to maintain parallel alignment of the eyes with the screen and the optimal distance.

[Note] Ensure the user is comfortably positioned relative to the optimal positioning and distance. User comfort and Windows Control performance are enhanced if the sun is not shining directly on the screen or into the user's eyes.

The optimal distance from the user to the EyeMobile Plus varies depending on the screen size. Generally, larger screens require a greater distance for optimal Tobii Dynavox Windows Control usage. Monitors exceeding the maximum screen size limitation should not be used for optimal performance. For more information, see Appendix C Technical Specifications, page 21.

5.2 Infrared Remote (IR)

To use the IR functionality on the EyeMobile Plus, you will need either Tobii Dynavox Virtual Remote or Tobii Dynavox Communicator 5. For instructions on using and programming these, refer to their respective user manuals.

5.2.1 Sending IR Signals

The IR transmitter for sending signals is located on the back of the EyeMobile Plus device (position 7 in Figure 3.1). Ensure the back of the EyeMobile Plus is pointed towards the device you wish to control with the IR.

5.2.2 Programming IR Signals

The IR Receiver for programming is located on the front of the EyeMobile Plus device (position 13 in Figure 3.1). When programming, point the remote control, whose signals you want Tobii Dynavox Virtual Remote or Tobii Dynavox Communicator 5 to learn, towards the front side of the EyeMobile Plus.

Settings

6.1 Microphone Settings

The EyeMobile Plus Microphone array is set as the default microphone in Microsoft Windows during the installation of the Tobii Dynavox Windows Control Software. You can configure the microphone array using the Microsoft Windows Control Panel > Sound > Recording settings. Refer to Microsoft's documentation for detailed instructions.

6.2 Switch Settings

The built-in switch ports on the EyeMobile Plus are designed for use with 3.5 mm switches connected directly to one of the two switch ports. By default, these ports are configured as "Joystick 1" and "Joystick 2" in Windows. Switch functionality is enabled within the applicable application software.

  1. Connect the first switch to one of the switch ports on the EyeMobile Plus.
  2. If two switches are needed, connect the second switch to the second switch port.

6.3 Setup Windows Hello

[Note] This feature only works with Windows 10.

  1. Open the Windows Start menu.
  2. Select your Account.
  3. Select Change Account Settings.
  4. Select Sign-in options.
  5. To proceed, set up a PIN code.
  6. Select the Add button under PIN and follow the subsequent steps.

[Note] Once the PIN is set up, the options to configure Windows Hello will unlock.

  1. After successfully setting up a PIN, you can select Set Up under Face.
  2. For more detailed background information on Windows Hello, select Learn more. Otherwise, select Get Started to continue.
  3. The camera in the eye tracker will assist in positioning yourself in front of the screen by displaying a livestream. Once positioned correctly, face recognition setup will begin automatically.
  4. Upon successful setup, an option to Improve Recognition will be available.

[Note] This feature can be useful if you wear glasses, as it allows recording with or without them.

Applicable Application Software

The EyeMobile Plus supports various uses depending on the user's needs and the installed application software. For support and documentation for compatible software, visit www.tobiidynavox.com.

Product Care

8.1 Temperature & Humidity

8.1.1 General Use

The EyeMobile Plus is best kept in dry conditions at room temperature. The recommended ranges are:

8.1.2 Transportation and Storage

For transportation and storage, the recommended ranges are:

The EyeMobile Plus is not waterproof or water-resistant. Avoid excessively humid, damp, or wet conditions. Do not submerge the device in water or any other liquid, and be careful not to spill liquids on it.

8.2 Cleaning

Before cleaning, shut down the computer connected to the EyeMobile Plus and unplug all cables. Use a soft, slightly damp, lint-free cloth. Avoid getting moisture into openings on the device. Do not use window cleaners, household cleaners, aerosol sprays, solvents, alcohol, ammonia, or abrasives.

Regular cleaning is recommended.

8.3 Transporting the EyeMobile Plus

Disconnect the USB cable and use the carrying case accessory. The EyeMobile Plus is fragile, and the eye-tracking filter can be scratched if not properly protected. Take precautions when carrying and packing the device. For repair, shipment, or travel, use the original casing and packaging materials.

[Warning] When the EyeMobile Plus is attached to a monitor/laptop, do not carry the connected devices by gripping only the EyeMobile Plus. It cannot support the weight of the monitor/laptop, which could cause the devices to break apart, topple, and fall, resulting in permanent damage. Tobii Dynavox is not liable for resulting damage.

8.4 Disposing of the EyeMobile Plus

Do not dispose of the EyeMobile Plus in general household or office waste. Follow your local regulations for the disposal of electrical and electronic equipment.

Support and Warranty

A1 Customer Support

For support, please contact your local representative or Tobii Dynavox Support. To receive assistance quickly, ensure you have your EyeMobile Plus accessible and, if possible, an internet connection. You should also be able to provide the device's serial number, found on the back. Find support pages online at: www.tobiidynavox.com or www.myTobiiDynavox.com.

A2 Warranty

Please read the Manufacturer's Warranty paper included in the package. Read this User's Manual carefully before using the device. The warranty is only valid if the device is used according to the User's Manual. Disassembling the EyeMobile Plus device will void the warranty.

[Note] It is recommended to keep the original packaging materials for the EyeMobile Plus. If the device needs to be returned to Tobii Dynavox for warranty-related issues or repair, using the original packaging or an equal equivalent for shipping is beneficial. Most shipping carriers require at least 2 inches of packing material around the device.

[Note] Due to Joint Commission regulations, any shipping materials, including boxes, sent to Tobii Dynavox must be discarded.

Compliance Information

The EyeMobile Plus is CE-marked, indicating compliance with essential health and safety requirements set out in European Directives.

B1 FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

[Note] Modifications not expressly approved by Tobii Dynavox could void the user's authority to operate the equipment under FCC rules.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

B2 Industry Canada Statement

This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

B3 CE Statement

The EyeMobile Plus complies with the following Directives:

B4 Standards

The EyeMobile Plus complies with the following standards:

Technical Specifications

EyeMobile Plus Specifications

Technical Specifications EyeMobile Plus
Gaze Data Rate 60 Hz
Data Streams Eye tracking (gaze point, eye position, etc.)
IR image stream at 30 fps
Power Consumption (Full Operation) 1.5 W typical average
Processing Unit Tobii EyeChip™ with fully embedded processing
Interface USB 2.0¹ (power and signal)
Head Movement Box² size at distance @ 45 cm (>17.1"): >20 cm x 20 cm ellipse (>7.9" x 7.9")
@ 50 cm (>19.7"): >25 cm x 20 cm ellipse (>9.8" x 7.9")
@ 65 cm (>25.6"): >40 cm x 30 cm ellipse (>15.7" x 11.8")
@ 80 cm (>31.5"): >35 cm x 35 cm circle (>13.8" x 13.8")
Distance from user to the Eye Tracker 45 cm - 80 cm (18" - 33")
User Calibration (former tracking robustness) >99%
Detected Gaze (Interaction >30 Hz) 99% for 95% of population³
Raw data max frame rate 90% for 95% of population⁴
Gaze Accuracy Across 95% of population³: <1.9°
Across 90% of population³: <1.7°
Across 80% of population³: <1.3°
Across 65% of population³: <1.0°
Ideal⁴: <0.3°
Gaze Precision Across 95% of population³: <0.4°
Across 90% of population³: <0.3°
Across 80% of population³: <0.25°
Across 65% of population³: <0.2°
Ideal⁴: <0.1°
Max Head Movement Speed 40 cm/s (15.7 in/s)
Eye Position Gaze Data 10 cm/s (3.9 in/s)
Max Head Tilt >20°
Max Yaw, pitch 25°
Visibility Low visibility (850 nm)
Flicker no flicker (30 Hz constant)
Data Flow and Data Rate 25 ms
Gaze Latency 100 ms
Gaze Recovery 640×480 @30 Hz
Low Resolution Stream 170 mm x 172mm x 40 mm
6.7" x 6.8" x 1.6"
Unit Size (Length x Height x Depth) 670 g
23.6 oz
Unit Weight Microsoft Surface Pro 4 and Surface Pro
Tobii Certified Tablets⁵ 265-310 mm × 185-205 mm × 8-10 mm
10.4-12.2" x 7.3-8.1" x 0.3-0.4"
Supported tablet dimensions (Length x Height x Depth) Microphone array consisting of 4 microphones
Microphone 2 x 3.5 mm Switch connector interface
Ports 1 x USB 2.0
1 x micro USB 3.0
1 x 5 VDC 4.4 mm Barrel Power Connector
Speakers 2 x 3.5 W
IR Remote Control (Environmental Control Unit) Learning remote with integrated library of pre-programmed devices
Battery Run Time > 9 hours, normal usage
Battery Technology Li-ion Polymer rechargeable battery
Battery Capacity 28 Wh
Battery Charge Time < 4 hours
Power Supply 5 VDC 3A AC adapter

Footnotes:

1. USB2 requirements: USB 2.0 BC1.2 provides Tobii IS4 with sufficient power and signal bandwidth.

2. Head box describes the space in front of the eye tracker where the user must have at least one eye to get gaze data. The eye tracker is at a 20° angle looking upward from below the screen.

3. The degree-of-accuracy and precision over percentage-of-population numbers result from extensive testing across representatives of the whole population. This testing has resulted in a much more robust and high-performance eye tracking experience and a more realistic representation of true performance across the whole population, not just in a mathematically "ideal" scenario.

4. The "ideal" degree numbers are the previous standard of measuring accuracy and precision. Though "ideal" numbers are useful for comparative quality and performance, they are not applicable to real-world usage in the same way as quantitative numbers based on extensive testing.

5. Other tablets that fulfill the system requirements and supported dimensions might be compatible, as long as the USB port and charging connector is not interfering with the EyeMobile Plus bracket.

Support Information

Copyright ©Tobii AB (publ). Illustrations and specifications may not apply to products and services offered in all local markets. Technical specifications are subject to change without prior notice. All other trademarks are the property of their respective owners.

Support for Your Tobii Dynavox Device

Get Help Online

See the product-specific Support page for your Tobii Dynavox device for up-to-date information, issues, and tips & tricks. Find our Support pages online at: www.TobiiDynavox.com or www.myTobiiDynavox.com.

Contact Your Sales Representative or Reseller

For questions or problems with your product, contact your Tobii Dynavox sales representative or authorized reseller for assistance. They are most familiar with your personal setup and can best help you with tips and product training. For contact details, visit www.TobiiDynavox.com/contact.

PDF preview unavailable. Download the PDF instead.

TobiiDynavox EyeMobilePlus UserManual v1-1 en-US WEB PDFlib PDI 9.0.6 (C /Win64) PTC Arbortext Publishing Engine

Related Documents

Preview TD Pilot User's Manual - Tobii Dynavox | Assistive Communication Device
Explore the Tobii Dynavox TD Pilot user manual. This guide details the TD Pilot, an advanced eye-tracking communication device integrated with Apple iPad, designed to enhance speech and independence for users with communication challenges.
Preview Tobii Dynavox PCEye 5 Safety and Compliance Guide
Comprehensive guide detailing safety precautions, warnings, and compliance information for the Tobii Dynavox PCEye 5 eye-tracking device. Covers mounting, epilepsy, infrared, magnetic fields, child safety, emergency use, computer control, third-party use, FCC, and CE standards.
Preview Tobii Dynavox TD I-110 User Manual: Features, Safety, and Specifications
Comprehensive user manual for the Tobii Dynavox TD I-110 Speech Generating Device (SGD). Covers setup, safety guidelines, features, technical specifications, and product care.
Preview Tobii Dynavox TD Pilot with TD Talk: Getting Started Guide
A comprehensive guide to setting up and using the Tobii Dynavox TD Pilot with TD Talk for eye gaze communication, including device setup, calibration, and app usage.
Preview TD Snap® Basics Training Cards - Tobii Dynavox
A comprehensive guide to Tobii Dynavox's TD Snap® software, focusing on training cards for users and communication partners. Learn about AAC principles, personalizing communication pages, editing buttons, saving and sharing data, and accessing support.
Preview TD Snap® Core First: Karty ćwiczeń - Przewodnik Tobii Dynavox
Przewodnik po kartach ćwiczeń TD Snap® Core First od Tobii Dynavox, zawierający instrukcje, porady i przykłady aktywności wspierających komunikację dla użytkowników AAC.
Preview TD Snap User's Manual
Comprehensive user manual for TD Snap, a symbol-based communication software by Tobii Dynavox, detailing features, setup, customization, and support for augmentative and alternative communication.
Preview TD Navio User Manual
User manual for the Tobii Dynavox TD Navio, a speech-generating device designed to aid communication for individuals with speech, language, physical, and cognitive impairments. Covers setup, safety, features, maintenance, and specifications.