Major Tech LED Floodlight Instruction Manual
ALF & LFB-50NWC Series
1. Introduction
This LED floodlight range is available in various wattages, offering flexible solutions for different lighting requirements. Designed to replace traditional floodlights, the range delivers high lumen outputs across models, ensuring excellent brightness and energy efficiency. Each unit features a durable 4mm strengthened clear glass cover, making it fully weatherproof (IP65 rated) and resistant to harsh environmental conditions. The light source consists of high-power SMD LEDs, which are thermally connected to an aluminium housing to ensure low heat emissions and extended lifespan. Depending on the model, the floodlights offer different IK impact protection ratings and include features such as wide voltage input compatibility and built-in surge protection. Installation must be carried out by a qualified electrical professional.
2. Installation
If any damage is noticed upon removing the product from the packaging, please return it to Major Tech before attempting installation. These lights must be installed by a qualified electrician. If the light is incorrectly installed by an unqualified individual, Major Tech reserves the right to refuse the return of the product.
2.1. Installation Steps
- Disconnect the power supply before installation.
- Remove the bracket from the floodlight for ease of installation.
- Drill 2 holes, place the bracket over the holes and screw into the wall (refer to diagrams). Please ensure installation height is within the specified range (Refer to Specifications table).
- Reconnect the floodlight to the bracket using the same connections as provided when the light was removed from the packaging.
- Connect the brown and blue wires respectively to the mains 'Live' and ‘Neutral', and connect the yellow and green wire to earth (refer to diagram).
- Confirm connection once installed.
Diagrams:
Figure 1 & 2: Illustrates drilling holes and mounting the bracket to the wall.
Figure 3: Shows reconnecting the floodlight to the bracket.
Figure 4: Depicts wiring connections: Live (L), Neutral (N), and Earth (E).
3. Maintenance
- Ensure the power is switched off before performing any maintenance.
- Clean the glass regularly using non-abrasive cleaners such as water and mild dishwashing liquid to maintain optimal light output.
- Wipe down the housing with a dry cloth to keep it clean and free of dust.
4. Multiple Installation Options
Diagrams illustrating various mounting positions for the floodlight.
3. Specifications
Function | ALF10NW | ALF20NW | ALF30NW | LFB-50NWC | ALF100NW | ALF200NW |
---|---|---|---|---|---|---|
Model | ALF10NW | ALF20NW | ALF30NW | LFB-50NWC | ALF100NW | ALF200NW |
LED Power | 10W | 20W | 30W | 50W | 100W | 200W |
LED Lumen | 1400Lm | 2800Lm | 4500Lm | 7500Lm | 15 000Lm | 30 000Lm |
Dimensions (mm) | 92x120x34 | 120x144x34 | 176x157x40 | 181x202x40 | 282x318x50 | 314x349x50 |
Weight | 238g | 384g | 583g | 886g | 1.79kg | 3.82Kg |
Installation Height | 2m - 3m | 2m - 4m | 2m - 5m | 3m - 6m | 5m - 8m | 5m - 8m |
IK Rating | IK07 | IK07 | IK07 | IK07 | IK08 | IK08 |
Surge Protection | 2kV | 2kV | 2kV | 4kV | 4kV | 4kV |
LED Type | SMD 2835 | |||||
Colour Temperature | 4000K - Natural White | |||||
Rated Life | 50 000 Hours | |||||
Voltage | 185-265V AC | |||||
Frequency | 50/60Hz | |||||
Power Factor | >0.9 | |||||
CRI | >80 | |||||
Beam Angle | 110° | |||||
IP Rating | IP65 | |||||
Temperatures (Working) | -20°C to 45°C | |||||
Temperatures (Storage) | -20°C to 65°C |
Major Tech (PTY) LTD
South Africa: www.major-tech.com | sales@major-tech.com
Australia: www.majortech.com.au | info@majortech.com.au
Certifications: CE, Recycling Symbol [recycle], Disposal Symbol [do-not-dispose]