ComfortStar Air Conditioner Remote Control Manual

Introduction

This document provides an illustration and guide for the ComfortStar air conditioner remote controller, designed for the Alegria Gold and Platinum Series.

The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.

Thank you for purchasing a ComfortStar air conditioner. Please read this owner's manual carefully before using your air conditioner.

Manufacturer Address: 12201 NW 107 Avenue, Medley, FL 33178. Website: www.comfortstarusa.com

Handling the Remote Controller

Location of the Remote Controller

Use the remote controller within a distance of 8 meters from the appliance, pointing it towards the receiver. Reception is confirmed by a beep ?.

Cautions

  • The air conditioner will not operate if curtains, doors, or other materials block the signals from the remote controller to the indoor unit.
  • Prevent any liquid from falling into the remote controller. Do not expose the remote controller to direct sunlight or heat.
  • If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent sunlight from falling on the receiver.
  • If other electrical appliances react to the remote controller, either move these appliances or consult your local dealer.

Replacing Batteries

The remote controller is powered by two dry batteries (R03/LR03x2) housed in the rear part and protected by a cover.

  1. Remove the cover by pressing and sliding it off.
  2. Remove the old batteries and insert the new batteries, placing the (+) and (-) ends correctly.
  3. Reattach the cover by sliding it back into position.

NOTE: When batteries are removed, all programming is erased. After inserting new batteries, the remote controller must be reprogrammed.

Battery Cautions

  • Do not mix old and new batteries or batteries of different types.
  • Do not leave the batteries in the remote controller if they are not going to be used for 2 or 3 months.
  • Do not dispose of batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

Remote Controller Specifications

ModelRG36F1EU1
Rated Voltage3.0V (Dry batteries R03/LR03x2)
Signal Receiving Range8m
Environment23°F~140°F

Performance Features

  • Operating Modes: AUTO, COOL, DRY, HEAT (for compatible models), FAN.
  • Timer Setting Function: Available in 24-hour increments.
  • Indoor Setting Temperature Range: 62°F~86°F.
  • Full function of LCD (Liquid Crystal Display).

NOTE: Button designs may vary slightly between models. All functions are controlled by the indoor unit. If the indoor unit does not support a specific feature, the corresponding remote button will have no effect.

Function Buttons

The remote control features a layout of buttons numbered 1 through 15. Key buttons include: ON/OFF, TEMP UP/DOWN, MODE, SILENCE/FP, FAN SPEED, SWING (horizontal and vertical), TIMER ON, TIMER OFF, SLEEP, TURBO/SELF CLEAN, LED/FOLLOW ME, and LOCK/RESET. The LCD display area is positioned at the top.

Button Descriptions:

  • 1. ON/OFF Button: Starts and stops operation.
  • 2. TEMP UP/DOWN Buttons (+/-): Increase/decrease the indoor temperature setting in 1°F increments (62°F to 86°F). Holding both for 3 seconds alternates between °C and °F display.
  • 3. MODE Button: Selects operation mode: AUTO, COOL, DRY, HEAT (for compatible models), FAN.
  • 4. SILENCE/FP Button: Activates/deactivates SILENCE function (low-frequency operation for quietness). Pressing for over 2 seconds activates FP function (high fan speed, 46°F setting for heating mode).
  • 5. FAN SPEED Button: Selects fan speed: AUTO, LOW, MED, HIGH.
  • 6. SWING Buttons (Horizontal/Vertical): Adjusts the direction of the louvers. Pressing briefly changes angle by 6 degrees. Pressing for over 2 seconds initiates automatic swing (up/down for horizontal, left/right for vertical).
  • 7. TIMER ON Button: Sets the auto-on timer. Increments by 30 minutes (up to 10 hours), then by 1 hour (up to 24 hours).
  • 8. TIMER OFF Button: Sets the auto-off timer. Increments similarly to TIMER ON.
  • 9. SLEEP Button: Activates/deactivates the SLEEP function for comfortable temperature and energy saving.
  • 10. TURBO/SELF CLEAN Button: Press briefly (less than 2s) for TURBO function (quick cooling/heating). Press and hold (more than 2s) for SELF CLEAN function (evaporator cleaning).
  • 11. LED/FOLLOW ME Button: Toggles the indoor unit display (LED). Press and hold for over 2 seconds to activate FOLLOW ME function (remote senses ambient temperature).
  • 12. LOCK Button: Locks/unlocks all remote control settings.
  • 13. RESET Button: Cancels all current settings and returns to initial settings.

Indicators on LCD

The LCD display shows various indicators for operation status.

  • Transmission Indicator: Lights up when signals are sent to the indoor unit. [Transmission Symbol]
  • Mode Display: Shows current operation mode (AUTO, COOL, DRY, HEAT, FAN).
  • Temp./Timer Display: Shows set temperature (62°F-86°F) or timer settings.
  • Fan Speed Display: Shows selected fan speed (AUTO, LOW, MED, HIGH).
  • ON/OFF Display: Indicates if the unit is on or off.
  • Lock Display: Appears when the LOCK function is active. ?
  • FOLLOW ME Display: Appears when the FOLLOW ME function is active.
  • Sleep Display: Appears when the SLEEP function is active.
  • Silence Display: Appears when the SILENCE function is active.

Note: Only relevant indicators are shown during actual operation.

How to Use the Buttons

Auto Operation

Ensure the unit is plugged in. The OPERATION indicator on the indoor unit display will flash.

  1. Press MODE to select Auto.
  2. Press UP/DOWN to set desired temperature (62°F-86°F).
  3. Press ON/OFF to start the air conditioner.

Note: In Auto mode, the unit automatically selects Cooling, Fan, or Heating based on ambient temperature. Fan speed is also automatically controlled.

Cooling/Heating/Fan Operation

Ensure the unit is plugged in.

  1. Press MODE to select COOL, HEAT (if available), or FAN.
  2. Press UP/DOWN to set desired temperature (62°F-86°F).
  3. Press FAN SPEED to select fan speed (AUTO, LOW, MED, HIGH).
  4. Press ON/OFF to start the air conditioner.

Note: In FAN mode, temperature setting is not displayed, and room temperature cannot be controlled. Only steps 1, 3, and 4 are applicable.

Dehumidifying Operation

Ensure the unit is plugged in. The OPERATION indicator on the indoor unit display will flash.

  1. Press MODE to select DRY.
  2. Press UP/DOWN to set desired temperature (62°F-86°F).
  3. Press ON/OFF to start the air conditioner.

Note: Fan speed is automatically controlled in Dehumidifying mode.

Adjusting Air Flow Direction

Use the SWING ↔ and SWING ➡ buttons to adjust airflow direction.

  • Press SWING ↔: Horizontal louvers move 6 degrees per press. Pressing for over 2 seconds initiates automatic up/down swing.
  • Press SWING ➡: Vertical louvers move 6 degrees per press. Pressing for over 2 seconds initiates automatic left/right swing.

Note: If louver movement affects cooling/heating, the direction will automatically adjust.

Timer Operation

Use TIMER ON to set auto-on time and TIMER OFF to set auto-off time.

To Set Auto-On Time:

  1. Press TIMER ON. Display shows TIMER ON, last setting, and "h".
  2. Press TIMER ON repeatedly to set desired auto-on time (0.5-10 hours in 30-min increments, then 10-24 hours in 1-hour increments).
  3. After setting, the unit confirms the setting. The "h" indicator disappears, and the set temperature reappears.

To Set Auto-Off Time:

  1. Press TIMER OFF. Display shows TIMER OFF, last setting, and "h".
  2. Press TIMER OFF repeatedly to set desired auto-off time (0.5-10 hours in 30-min increments, then 10-24 hours in 1-hour increments).
  3. After setting, the unit confirms the setting. The "h" indicator disappears, and the set temperature reappears.

Combined Timer (Auto-On and Auto-Off Simultaneously]

TIMER OFF → TIMER ON (Stop → Start): Useful for stopping the unit at night and starting it in the morning.

TIMER ON → TIMER OFF (Start → Stop): Useful for starting the unit before waking and stopping it after leaving.

Example: To start in 2 hours and stop in 5 hours: Press TIMER ON, set 2.0h. Press TIMER OFF, set 5.0h. The "TIMER ON OFF" indicator will remain on.

Caution: Timer settings are limited to specific increments (0.5, 1.0, ..., 24 hours).

LED/FOLLOW ME Function

Press LED/FOLLOW ME button briefly to toggle the indoor unit display (LED). Press and hold for over 2 seconds to activate FOLLOW ME function.

When FOLLOW ME is active, the remote displays the ambient temperature at its location and sends this information every 3 minutes. This function is not available in DRY or FAN modes. It is cancelled by changing the mode or turning off the unit.

TURBO/SELF CLEAN Function

Press TURBO/SELF CLEAN button briefly (less than 2 seconds) to activate TURBO function for rapid cooling/heating.

Press and hold (more than 2 seconds) to activate SELF CLEAN function, which cleans and dries the evaporator.

Note: TURBO function effectiveness depends on indoor unit support.

LOCK Button

Press the LOCK button to lock all current settings. Press again to unlock.

PDF preview unavailable. Download the PDF instead.

RG36-remote-manual Corel PDF Engine Version 9.397

Related Documents

Preview ComfortStar Air Conditioner Remote Controller Manual
User manual and illustration for ComfortStar Alegria Gold and Platinum Series air conditioner remote controllers, detailing functions, operations, and specifications.
Preview ComfortStar ARC-88B Remote Controller Owner's Manual
This manual provides instructions for operating the ComfortStar ARC-88B remote controller for air conditioning units, covering basic and advanced functions, specifications, and troubleshooting.
Preview ComfortStar ARC-88B Remote Controller Owner's Manual
This manual provides detailed instructions for operating the ComfortStar ARC-88B remote controller for your air conditioner. It covers specifications, button functions, screen indicators, basic and advanced operations, and timer settings.
Preview ComfortStar FPA-24/CZP24CD(O) Submittal Data Sheet - 24,000 BTU/H Wall Mounted Heat Pump System
Comprehensive submittal data sheet for the ComfortStar FPA-24/CZP24CD(O) 24,000 BTU/H Wall Mounted Heat Pump System. Details include system performance, electrical specifications, cooling and heating capacities, refrigerant data, indoor and outdoor unit specifications, and general features.
Preview ComfortStar High Wall Heat Pump System Submittal Data Sheet
Submittal data sheet for the ComfortStar High Wall Heat Pump System, model CPP3-36CD(I) (23V) / CPP3-36CD(O) (23H). Includes specifications for cooling, heating, electrical, and piping, along with indoor and outdoor unit dimensions and installation instructions.
Preview ComfortStar CGS18CD(I)/CGS18CD(O) 18,000 BTU Wall Mounted Heat Pump Submittal Data
Detailed submittal data sheet for the ComfortStar CGS18CD(I)/CGS18CD(O) 18,000 BTU/H wall-mounted heat pump system, including performance specifications, dimensions, and features.
Preview ComfortStar Portable Air Conditioner CPU12A Specifications and Features
Detailed specifications and features of the ComfortStar Portable Air Conditioner, model CPU12A. Includes cooling capacity, energy efficiency, technical data, and operational modes like Eco Cooling and 3-in-1 functionality.
Preview ComfortStar Wi-Fi Function User Manual: Smart Control Guide
Learn how to connect and control your ComfortStar air conditioner with the SmartLife-SmartHome app. This user manual covers app installation, device setup, remote operation, and troubleshooting for enhanced home comfort.