ELKO Smart ZB Thermostat 16 A Installation Guide

ELKO Smart ZB Thermostat 16 A Installation Guide

About This Product

The ELKO Smart ZB Thermostat 16 A is designed primarily for electric underfloor heating or electric radiators. It can also be used to control mains-powered motorized valves or circulating pumps for water-based heating systems.

Control Options

  • Direct operation: The thermostat can always be controlled on-site.
  • Control modes:
    • a. Room air temperature sensor only
    • b. Floor sensor only
    • c. Room air temperature for control and floor sensor for limiting heating temperature
  • Note: The thermostat is compatible with multiple floor sensor types.

Functions

  • Current room temperature and setpoint.
  • Heating/cooling and connection status.
  • Presets for various heating systems.

Package Content

  • A: Insert
  • B: Frame
  • C: Control module
  • D: Gasket (for IP31 upgrade)
  • E: Sensor cable
  • F: Installation instructions

Product Details

  • A: Dot matrix display
  • B: Touch buttons

Selecting the Installation Site

To ensure reliable room temperature measurement, the internal temperature sensor must be protected from external influences and temperature fluctuations.

Insert Installation Site

  • Recommended installation height: 1 meter above the floor.
  • Avoid installation near windows, doors, or ventilation openings.
  • Do not install above heaters or other heat sources.
  • Do not cover or install behind curtains.
  • Avoid direct sunlight and lamp light.

Floor Sensor Installation Site

For reliable operation, protect the floor sensor from moisture, mechanical stress, and temperature fluctuations.

  • Install the sensor in the middle of the underfloor heating unit's loops.
  • Lay the sensor cable in a plastic tube with an inner diameter of at least 16 mm.
  • Attach tape to the end of the tube and cut a slice to allow condensation water to drain.
  • Ensure tube corners are not too tight, as they can affect sensor cable installation.

Electrical Connections

DANGER: HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

Safe electrical installation must be performed only by qualified professionals with knowledge in connecting to installation networks, multiple electrical devices, laying electric cables, and relevant safety standards and regulations. Failure to follow these instructions can result in death or serious injury.

DANGER: RISK OF FATAL INJURY FROM ELECTRIC SHOCK

The output may carry electrical current even when the load is switched off. Always disconnect the device from the power supply via the fuse in the incoming circuit before working on the unit. Failure to follow these instructions can result in death or serious injury.

DANGER: RISK OF FATAL INJURY FROM ELECTRIC SHOCK

The device is not a Safety Extra Low Voltage (SELV) device. Sensor lines are connected to the mains (AC 230 V) line. Use only sensors with mains voltage basic insulated cable. Failure to follow these instructions can result in death or serious injury.

NOTE: It is recommended to use only sensors tested as compatible. Refer to the Device User Guide for a list of compatible sensors.

A: Load connection: max. 16 A.

B: Input for floor sensor (optional).

Mounting

Optional IP31 Protection:

  • 1. Place the gasket on the fixing plate.
  • 2. Complete the device with an ELKO RS16 or ELKO Plus frame.

Module Installation:

  • 1. If not preconfigured, pull the frame over the module, minding the orientation of the module springs.
  • 2. Clip the module into the insert.

NOTICE: EQUIPMENT DAMAGE

The module is firmly connected to the insert with a cable. Do not pull hard on the module or insert. When unmounting, note the cable length. Failure to follow these instructions can result in equipment damage.

Presets

A preset must be selected after the first power-up or reset.

Preset Configuration
P1Heat Pump/Oil Boiler (Room sensor)
P2Hydronic Radiator/Gas Boiler (Room sensor)
P3Hydronic Underfloor (Room sensor)
P4Electrical Radiator (Room sensor)
P5Electrical Underfloor (Room sensor - without floor limit sensor)
P6Electrical Underfloor (Room sensor - with floor limit sensor)
P7Hydronic Underfloor (Floor sensor)
P8Electrical Underfloor (Floor sensor)
P9Regulator Mode (based on percentage)

Selecting a Preset

To switch between presets, press the '+' or '-' push-button. Use '+' to increase the preset value and '-' to decrease it.

Confirming the Preset

To confirm the selection, press and hold both the '+' and '-' buttons simultaneously for more than 1 second.

Detailed information about presets can be found in the Device User Guide.

Reading the Full Device User Guide Online

Scan the [QR code for online guide] and select your language for complete information about the device, including operation, configuration, and using the product with an ELKO Smart system.

Technical Data

Nominal voltage:AC 230 V~, 50 Hz
Maximum current rating:max. 16 A, 3520 W
Resistive load:max. 16 A, 3520 W
Inductive load:max. 4 A
Standby:max. 0.5 W
Connecting terminals:Screw terminals for max. 2.5 mm², 0.5 Nm
Neutral conductor:Required
Ambient operating temperature:0 to 40 °C
Relative humidity:max. 90% non-condensing
Temperature accuracy:max. ±0.5 °C (across the range of 4 to 30 °C)
Temperature measurement resolution:max. 0.1 °C
Display:7x5 dot matrix, 3 additional LEDs
Operating frequency:2.401 GHz to 2.483 GHz
Max. radio-frequency power transmitted:< 10 mW
Communication protocol:Zigbee 3.0 certified
Floor sensor types:10k, 12k, 15k, 33k, 47k (Thermistor resistance values in Ohm. Nominal value at 25 °C)
Protection Class:II
Working voltage:230 V
Over-voltage category:III
Rated impulse voltage:4 kV
Pollution degree:2
CTI rating of insulation components:175 V
Material group:IIIa (based on CTI value)
Disconnection type:1.B

Trademarks

Zigbee® is a registered trademark of the Connectivity Standards Alliance. Other brands and registered trademarks are properties of their relevant owners.

EU Declaration of Conformity

ELKO declares that this product complies with the essential requirements and other relevant provisions of RADIO EQUIPMENT DIRECTIVE 2014/53/EU. Declaration of conformity can be downloaded on: ELKO.no.

Contact Information

ELKO AS

Sandstuveien 68, 0680 Oslo

Pb 6598 Etterstad, 0607 Oslo

+47 67 79 39 00

support@elko.no

www.elko.no

Models: EKO07258 Plus SmartTermostat Zigbee Touch, EKO07258, Plus SmartTermostat Zigbee Touch, SmartTermostat Zigbee Touch, Zigbee Touch, Touch

File Info : application/pdf, 4 Pages, 2.33MB

PDF preview unavailable. Download the PDF instead.

EKO0725x EKO30465 HW

References

Adobe PDF Library 17.0 Adobe InDesign 18.1 (Windows)

Related Documents

Preview ELKO Smart ZB Thermostat 16 A: Device User Guide
Comprehensive guide for the ELKO Smart ZB Thermostat 16 A, covering installation, manual operation, app integration, and smart home features for efficient heating control.
Preview ELKO One – Matter Thermostat 16 A: User Guide for Smart Heating Control
Comprehensive user guide for the ELKO One Matter Thermostat 16 A, detailing features, installation, setup, user settings, and troubleshooting for smart home heating systems.
Preview Wi-Fi® Thermostat 16 A Device User Guide
This user guide provides commissioning instructions for the ELKO Smart system, devices, and app, focusing on the Wi-Fi® Thermostat 16 A. It details installation, operation, manual settings, app integration, and troubleshooting for efficient temperature control.
Preview ELKO One RJ45 CAT6 UTP Data Socket - Product Environmental Profile
Detailed environmental profile for the ELKO One RJ45 CAT6 UTP data socket, covering constituent materials, life cycle impacts, and substance assessment. Includes PEP Ecopassport certification.
Preview ELKO Smart Smoke Alarm 230 V User Guide
Comprehensive user guide for the ELKO Smart Smoke Alarm 230 V, covering installation, pairing, operation, maintenance, and troubleshooting. Learn how to set up and utilize the smart features of your smoke alarm for enhanced safety.
Preview ELKO One SSO Schuko Screwless Pure White: Product Environmental Profile & Sustainability Data
Detailed environmental product declaration (EPD) for the ELKO One SSO Schuko screwless pure white socket outlet, covering its life cycle impacts, constituent materials, and sustainability metrics as part of the PEP ecopassport® program.
Preview ELKO One Keycard Switch EKO50065/EKO50066 Installation and Operation Guide
Comprehensive guide for the ELKO One Keycard Switch (models EKO50065, EKO50066), detailing installation procedures, safety warnings, technical specifications, and various wiring configurations for commercial and hospitality applications. Includes multilingual support information.
Preview ELKO One Dimmer: Product Environmental Profile & Lifecycle Analysis
Detailed environmental profile of the ELKO One multiwire LED dimmer (370W, recycled PC). This PEP ECOPASSPORT® document outlines constituent materials, functional unit, and lifecycle impact indicators, including climate change, resource use, and waste disposal.