User Guide for ELKO models including: 16 A, EKO07258 16A Smart ZB Thermostat, EKO07258, 16A Smart ZB Thermostat, Smart ZB Thermostat, ZB Thermostat, Thermostat
Smart ZB Thermostat 16 A - ELKO Smart Technical Guides
File Info : application/pdf, 46 Pages, 7.21MB
DocumentDocumentSmart ZB Thermostat 16 A Device User Guide Commissioning instructions for the ELKO Smart system, devices and app. 02/2023 www.elko.no Legal Information The ELKO brand and any trademarks of ELKO AS and its subsidiaries referred to in this guide are the property of ELKO AS or its subsidiaries. All other brands may be trademarks of their respective owners. This guide and its content are protected under applicable copyright laws and furnished for informational use only. No part of this guide may be reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), for any purpose, without the prior written permission of ELKO. ELKO does not grant any right or license for commercial use of the guide or its content, except for a non-exclusive and personal license to consult it on an "as is" basis. ELKO products and equipment should be installed, operated, serviced, and maintained only by qualified personnel. As standards, specifications, and designs change from time to time, information contained in this guide may be subject to change without notice. To the extent permitted by applicable law, no responsibility or liability is assumed by ELKO and its subsidiaries for any errors or omissions in the informational content of this material or consequences arising out of or resulting from the use of the information contained herein. Table of Contents Safety information.......................................................................................4 Smart ZB Thermostat 16 A ........................................................................5 For your safety ...........................................................................................5 About the device.........................................................................................6 Installing the device ....................................................................................6 Setting and operating the device manually....................................................7 Device presetting ..................................................................................7 Manual sensor settings .......................................................................10 Setting boost mode manually ...............................................................12 Turning on/off the device manually .......................................................13 Pairing the device .....................................................................................14 Pairing device manually.......................................................................14 Pairing device with auto scan...............................................................16 Configuring the device ..............................................................................17 Changing the device icon ....................................................................17 Renaming the device ..........................................................................18 Changing the device location ...............................................................18 Managing device settings using ELKO Smart app..................................19 Using the device.......................................................................................25 Individual thermostat visibility on home page.........................................27 Setting the room temperature manually ................................................27 Setting the room temperature using app ...............................................28 Using the boost mode .........................................................................29 Checking the device history .................................................................30 Creating a schedule ............................................................................31 Creating a moment .............................................................................32 Creating an automation .......................................................................34 Removing the device from ELKO system....................................................38 Resetting the device .................................................................................39 LED Indications ........................................................................................41 Troubleshooting .......................................................................................43 Technical Data .........................................................................................44 DUG_ZB Thermostat 16 A_ELKO-00 3 Safety information Safety information Important information Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service, or maintain it. The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of either symbol to a "Danger" or "Warning" safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that accompany this symbol to avoid possible injury or death. DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. Failure to follow these instructions will result in death or serious injury. WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE NOTICE is used to address practices not related to physical injury. 4 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A Smart ZB Thermostat 16 A EKO07254 EKO07257 EKO07258 EKO07259 EKO30465 For your safety DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Safe electrical installation must be carried out only by skilled professionals. Skilled professionals must prove profound knowledge in the following areas: · Connecting to installation networks. · Connecting several electrical devices. · Laying electric cables. · Safety standards, local wiring rules and regulations. Failure to follow these instructions will result in death or serious injury. DANGER RISK OF FATAL INJURY FROM ELECTRIC SHOCK The output may carry electric current even when the load is switched off. · Disconnect the device from the supply by means of the fuse in the incoming circuit before working on the device. Failure to follow these instructions will result in death or serious injury. DANGER RISK OF FATAL INJURY FROM ELECTRIC SHOCK The device is not a Safety Extra Low Voltage (SELV) device.The sensor lines are on mains (AC 230 V) line. · Only use sensors with mains voltage basic insulated cable. Failure to follow these instructions will result in death or serious injury. DUG_ZB Thermostat 16 A_ELKO-00 5 About the device Smart ZB Thermostat 16 A The Smart ZB Thermostat 16 A (hereinafter referred to as cFMT / thermostat) is mainly used for electrical heating applications like electrical underfloor heating and electrical radiators / heating panels. Thermostat features: · Dot-matrix displays (current room and set temperature) · Control the room temperature setpoint. · Boost mode for ease and comfort · Child lock · Valve protection · Measure energy consumption and monitor temperature in the room · Smart schedule through ELKO Smart app Operating elements A. Dot-matrix display · Wireless connectivity LED ( ) · Heat demand LED ( ) TIP: All LED indications are explained in the LED behavior, page 41 chapter. B. Touch buttons · +/: to increase / decrease the value. · O: function button A B Installing the device Refer to the installation instruction supplied with this product. See Smart ZB Thermostat 16 A. 6 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A Setting and operating the device manually As a standalone thermostat, you can set the following settings and operating parameters. Preset Sensor type selection Floor calibration setting Max guard temp. setting Boost mode Standalone schedule P1 x x x P2 x x x P3 x x x P4 x x x P5 x x x P6 P7 P8 P9 x x x Sensor type selection, page 10 Floor calibration setting, page 10 Max guard temp. setting, page 10 Boost mode, page 12 Device presetting You can preset the thermostat on the first power-on or immediately after a factory reset. The thermostat will require the selection of a preset to pre-configure settings depending on what the thermostat is directly controlling, which allows the thermostat to function correctly for the intended use case. Preset selection is a manual process and all preset uses a PI control algorithm which provides highly stable results. You can choose one preset configuration: Preset P1 P2 P3 P4 P5 P6 P7 P8 P9 Configuration Heat Pump/Oil Boiler Hydronic Radiator/Gas Boiler Hydronic Underfloor Electrical Radiator Electrical Underfloor (Without floor limits) Electrical Underfloor (With floor limits) Hydronic Underfloor Electrical Underfloor Regulator Mode (output displayed is based on percentage) Control type / Set point range Room Control 4°C ~ 30°C Floor Control 10°C ~ 40°C Floor Control 0 ~ 10 (0% ~ 100%) Cycle time* (min) 20 10 10 10 10 10 10 10 30 *Cycle time: This setting determines the length of each on/off cycle of the output relay. The percentage of time within that cycle time that the relay is on is varied based on demand. A longer cycle time may be more appropriate for slow heating DUG_ZB Thermostat 16 A_ELKO-00 7 Smart ZB Thermostat 16 A surfaces, such as a concrete floor. A short cycle time is more appropriate for faster heating surfaces, such as an electric panel heater. Initial preset configuration (by default) When the thermostat is first powered on or immediately after a factory reset, by default "P5" flashes on the matrix LED's if there is no external sensor connected, or "P8" if there is any external sensor connected. Modifying the preset value To modify the preset from default value, simultaneously press "O" and "+" for 10 s to enter advanced settings menu. Then press + button on the thermostat, it increases the preset value by 1 and when button is pressed, it decreases the preset value by 1. For example, when + button is pressed, preset P1 becomes P2, continue to press the + button, and the preset changes to P3, P4...P9. Similarly, when button is pressed, preset P9 changes to P8, continue to press the button, preset changes to P7, P6...P1. 8 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A Confirming the preset Select the preset that meets your needs using the +/- buttons, and then hold the O for > 1 s to confirm the selection. For example, P1 is confirmed. > 1 s · Cycle Time : 20 mins · Valve Protection : Off If the preset value of P6, P7 or P8 is set and the thermostat is connected with an external floor sensor then you need to set the sensor type. Refer manual sensor settings, page 10. NOTE: After configuring the thermostat, if you want to change or modify the preset or sensor setting, press O and + button simultaneously to enter preset selection and continue the process. DUG_ZB Thermostat 16 A_ELKO-00 9 Smart ZB Thermostat 16 A Manual sensor settings A thermostat with a preset value of P6 to P8 can be connected with an external floor sensor to increase the user's experience in regulating the temperature. NOTE: Once the preset is chosen, press O button for 1 second to confirm. Then the device continues to the sensor setting in the below sequence. For more info on preset, refer device presetting, page 7 Selecting floor sensor type After preset, you will enter floor sensor selection menu where you can manually select the sensor type connected to the thermostat after setting the preset; this allows the thermostat to convert and display the temperature accurately. To select the floor sensor type: 1. Once you enter the selection menu, "10" will be displayed on the thermostat dot matrix. Press + or touch button on the device to switch between the sensor types. Following are the available sensor type: · 10 kOhm · 12 kOhm · 15 kOhm · 33 kOhm · 47 kOhm TIP: When + button is pressed, sensor type 10 becomes 12, continue to press the + button, and the type changes to 15, 33, and 47. When button is pressed, sensor type 47 becomes 33, continue to press the button, and the type changes to 15, 12, and 10. 2. Select the sensor type which is installed and then press the O touch button for > 1 s to confirm the selection. The thermostat dot-matrix display the sensor type and LED flashes blue. 10 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A Setting temperature calibration After selecting the floor sensor type, you must set the calibration value (offset value) of the sensor in order to minimize any variation in temperature measurement. To set temperature calibration: 1. Press + or touch button on the device to set the calibration value between. NOTE: The temperature calibration ranges from -9°C to +9°C and can be adjusted in 0.5°C increments. 2. Set the calibration value, press the O touch button for > 1 s to confirm the selection. The thermostat dot-matrix display calibration value and LED flashes purple. Setting maximum guard temperature After setting temperature calibration, you must set the maximum guard temperature. It is upper limit of the floor sensor. Minimum guard temperature can only be set through ELKO Smart app. To set maximum guard temperature: 1. Press + or touch button on the device to set the maximum limit. NOTE: The temperature limit ranges from 11°C to 40°C. 2. Set the value, press the O touch button for > 1 s to confirm the selection. The thermostat dot-matrix display calibration value and LED flashes red. IMPORTANT: · If you want to update the sensor settings manually after setting up the device, Press O and + button simultaneously to enter preset selection and press O to confirm preset and enter sensor setting. · You can also perform a factory reset to remove all settings and configure the thermostat newly. Refer resetting the device, page 39. · It is possible to modify or update sensor settings without resetting the thermostat with the ELKO Smart app. Refer app settings, page 19 DUG_ZB Thermostat 16 A_ELKO-00 11 Smart ZB Thermostat 16 A Setting boost mode manually You can enable and disable boost mode manually. When enabled the temperature increases by 2° C for temperature control modes (P1 to P8) and by +2 for regulator mode (P9) over the setpoint. To enable boost mode: 1. Press O button once to enter boost menu. +1 flashes on thermostat matrix. NOTE: The thermostat will exit boost mode if there is no interaction within 5 seconds after pressing O button. 2. Use +/- button to navigate between the boost hours from +1 to +3 3. Select boost hour and press O button to confirm selection. For example: If current setpoint is 12° C and you enable boost mode by selecting +3. The boost mode will set the setpoint temperature to 14° C for next 3 hour. After 3 hour setpoint will return to 12° C. 12 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A To disable boost mode: 1. Press O button once. +1 flashes on thermostat matrix. 2. Press + button for thermostat to display (boost cancel). 3. Confirm by pressing O button. Boost mode is cancelled. Turning on/off the device manually When thermostat is not in use, you can turn on/off the device manually NOTE: Make sure to disable childlock before turning off the device. Press for > 10 s to turn off. > 10 s When thermostat is fully off: · LED displays no room temperature · Does not control room temperature · Outputs remain off · On initial interaction, the device shows an "X" on the display to show that it is off. Wake the thermostat by pressing /O/+ once, thermostat matrix display X and then press /O/+ button for > 5 s to turn. OR OR > 5 s > 5 s > 5 s When the thermostat is turned on, it returns to its last state. DUG_ZB Thermostat 16 A_ELKO-00 13 Pairing the device Smart ZB Thermostat 16 A Using the ELKO Smart app, pair your device with the ELKO SmartHub to access and control the device. You can either add the device manually or do an auto-scan to pair it. Pairing device manually To pair the device manually: 1. On the Home page, tap +. 2. Tap and select the required ELKO SmartHUB on the slide-up menu. 3. Select an option to add the device (A): Add Device with Install Code Add Device without Install Code Add Device Install Code is Recommended Add Device without Install Code A TIP: It is highly recommended to add the device with Install code. 4. To pair the device with an install code, tap Add Device with Install Code to display the slide-up menu. Select any one of the options (B): Scan Install Code - you can scan the device for the install code. Enter Install Code Manually - you can manually enter the install code from the device. After pairing the device with install code, proceed to Step 6. Add Device Install Code is Recommended Add Device without Install Code B 5. To pair the device without install code, tap Add Device without Install Code. 14 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A 6. Long press the O button until Jn is displayed and then release the button to initiate joining. NOTE: If you have already paired your thermostat, and want to change the preset mode during the current pairing process, you will need to perform a factory reset. Otherwise, the thermostat will be paired with the previous preset mode. Refer resetting the device, page 39. "Jn" will flash on the matrix. 7. In the app, tap Confirm device display Jn and than tap Start Configuration (C). Cancel How to pair device For commissioning, long press the O button > 3s until "Jn" is displayed on the matrix. Note: To change the preset mode, user need to do factory reset on device. C 8. Wait for a few seconds until the wireless green. LED on the thermostat turns 9. After the device is added in the app, assign a room to enable settings and than tap Done. NOTE: · Assigning a room, creates a group to control the thermostats, refer using the device, page 25. · Refer changing the device location, page 18 to assign a room to the thermostat, if you did not assign the room at Step 9. DUG_ZB Thermostat 16 A_ELKO-00 15 Smart ZB Thermostat 16 A Pairing device with auto scan Pairing the device with auto scan automatically discovers the device when it is powered on. 1. On the Home page, tap +. 2. Tap Auto scan > Confirm. 3. Enable permissions to Access location and Wi-Fi for scanning device and tap Start scanning. NOTE: If you have multiple hubs, do Step 4 or proceed to Step 5. 4. Tap Select hub and select the ELKO SmartHUB from the slide-up menu. 5. Long press the O button until 'Jn' is displayed and then release the button to initiate joining. NOTE: If you have already paired your thermostat, and want to change the preset mode during the current pairing process, you will need to perform a factory reset. Otherwise, the thermostat will be paired with the previous preset mode. Refer resetting the device, page 39. TIP: If you want to pair multiple devices at once, perform step 5 on each device and wait for a few seconds. 6. Wait for a few seconds until the device search is complete, than tap Next (A) and select Smart ZB Thermostat 16 A. Auto Scan Available devices found Smart ZB Thermostat 16A Next A 7. Once the device is paired successfully, assign a room to enable settings and than tap Done. NOTE: · Assigning a room, creates a group to control the thermostats, refer using the device, page 25. · Refer changing the device location, page 18 to assign a room to the thermostat, if you did not assign the room at Step 7. 16 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A Configuring the device Changing the device icon You can change the device icon using the ELKO Smart app. 1. On the Home page, select the device for which you wish to change the icon. 2. At the top-right corner of the screen, tap . 3. Tap edit next to the device name. 4. Tap Icon to view the menu. 5. In the slide-up menu, select any one of the following (A) to change the device icon: Take photo - allows you to click a photo from the mobile camera. Select from Icon Library - allows you to select an icon from the app library. Select from Album - allows you to select a photo from the mobile gallery. DUG_ZB Thermostat 16 A_ELKO-00 17 Smart ZB Thermostat 16 A Renaming the device You can rename the device using the ELKO Smart app. 1. On the Home page, select the device for which you wish to rename. 2. At the top-right corner of the screen, tap . 3. Tap edit next to the device name. 4. Tap Name, enter the new name (A) and then tap Save. Name Rename Save A Changing the device location You can change the device location using the ELKO Smart app. 1. On the Home page, select the device for which you wish to change the location. 2. At the top-right corner of the screen, tap . 3. Tap edit next to the device name. 4. Tap Location. 5. Select the desired location from the list (A) and then tap Save. Device location Save Living Room Master Bedroom Dining Room Study Room Kids Room A 18 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A Managing device settings using ELKO Smart app Using the ELKO Smart app, you can manage the thermostat settings. To access the settings: 1. On the Home page, tap All devices > Thermostat. 2. On the device control panel page, tap Settings. All setting option in the ELKO Smart app is based on the preset value set during paring process. Preset Valve protec- tion P1 P2 P3 P4 x P5 x P6 x P7 P8 x P9 x Air calibra- tion setting x x x Sensor type selection x x x x Floor calibra- tion setting x x x x Max/ Min guard temp. setting x x x x Child lock Rated power value x x x x Screen brightness settings Valve protection, page 22 Air calibration setting, page 21 Sensor type selection, page 21 Floor calibration setting, page 21 Max/Min guard temp. setting, page 21 Child lock, page 23 Rated power value, page 23 Screen brightness settings, page 24 DUG_ZB Thermostat 16 A_ELKO-00 19 Below are the setting interface based on preset: P1 and P2 P3 Settings Sensors Settings Temperature Detection Air Temperature Temperature Calibration ? Valve Protection Settings Valve Protection Child Protection Settings Child Lock Screen Brightness Settings Active Brightness Level +0.1 C 100% Idle Brightness Level 100% Screen Active Duration 1 Min(s) 0 Sec(s) Settings Sensors Settings Temperature Detection Temperature Calibration ? Air Temperature -9.0 C Temperature Detection Floor Temperature Floor Sensor Type ? -- K Temperature Calibration ? 0.0 C Max Guard Temperature 30 C Min Guard Temperature 10 C Valve Protection Settings Valve Protection Child Protection Settings Child Lock Screen Brightness Settings Active Brightness Level Idle Brightness Level Screen Active Duration 100% 100% 1 Min(s) 0 Sec(s) Smart ZB Thermostat 16 A P4 Settings Sensors Settings Temperature Detection Air Temperature Temperature Calibration ? Rated Power Settings Rated Power Value Child Protection Settings Child Lock Screen Brightness Settings Active Brightness Level +0.1 C 0 W 100% Idle Brightness Level 100% Screen Active Duration 1 Min(s) 0 Sec(s) P5 and P6 P7 Settings Sensors Settings Temperature Detection Temperature Calibration ? Air Temperature -9.0 C Temperature Detection Floor Temperature Floor Sensor Type ? -- K Temperature Calibration ? 0.0 C Max Guard Temperature 30 C Min Guard Temperature 10 C Rated Power Settings Rated Power Value ? 0 W Child Protection Settings Child Lock Screen Brightness Settings Active Brightness Level Idle Brightness Level Screen Active Duration 100% 100% 1 Min(s) 0 Sec(s) P8 Settings Sensors Settings Temperature Detection Floor Temperature Floor Sensor Type ? 10K Temperature Calibration ? 0.0 C Max Guard Temperature 40 C Min Guard Temperature Valve Protection Settings Valve Protection Child Protection Settings Child Lock Screen Brightness Settings Active Brightness Level 10 C 100% Idle Brightness Level 100% Screen Active Duration 1 Min(s) 0 Sec(s) P9 Settings Sensors Settings Temperature Detection Floor Temperature Floor Sensor Type ? 10K Temperature Calibration ? 0.0 C Max Guard Temperature 40 C Min Guard Temperature Rated Power Settings Rated Power Value ? Child Protection Settings Child Lock Screen Brightness Settings Active Brightness Level 10 C 0 W 100% Idle Brightness Level 100% Screen Active Duration 1 Min(s) 0 Sec(s) Settings Rated Power Settings Rated Power Value 0 W Child Protection Settings Child Lock Screen Brightness Settings Active Brightness Level 0% Idle Brightness Level 0% Screen Active Duration 0 Min(s) 5 Sec(s) 20 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A Sensors settings Settings Sensors Settings Temperature Detection Temperature Calibration ? Air Temperature -9.0 C A B Temperature Detection Floor Sensor Type ? Floor Temperature -- K C Temperature Calibration ? Max Guard Temperature E Min Guard Temperature 0.0 C 30 C 10 C D Valve Protection Settings Valve Protection Child Protection Settings Child Lock Screen Brightness Settings Active Brightness Level Idle Brightness Level Screen Active Duration 100% 100% 1 Min(s) 0 Sec(s) Temperature detection You can check the sensor type (A) under temperature detection, based on your preset. Air Temperature: for preset P1 to P6. Floor Temperature: for preset P7 to P8. NOTE: Sensor settings are not available for regulator mode (P9). Temperature calibration To set the temperature calibration: 1. Tap Temperature Calibration (B) for a slide-up menu. 2. Drag the sliding bar or use /+ button to set the temperature calibration. NOTE: The temperature calibration ranges from -9°C to +9°C and can be adjusted in 0.1°C increments. 3. Tap Save. Floor sensor type To select the floor sensor type: 1. Tap Floor Sensor Type (C) for slide up menu. 2. Select the sensor type (kOhm) form the following list. · 10K · 12K · 15K · 33K · 47K NOTE: Select correct floor sensor type which is installed and then you can set calibration and guard temperature. DUG_ZB Thermostat 16 A_ELKO-00 21 Guard temperature Smart ZB Thermostat 16 A To set the maximum and minimum guard temperature: · On setting page, tap Max Guard Temperature (D) to set upper temperature limit of the floor sensor and then tap Save. NOTE: The temperature ranges form 5°C to 19°C and maximum guard temperature should be higher than minimum guard temperature · Tap Min Guard Temperature (E) to set lower temperature limit of the floor sensor and then tap Save. NOTE: The temperature ranges form 21°C to 40°C and minimum guard temperature should be lower than maximum guard temperature Valve protection settings Hydronic underfloor heating and boiler connections require valves and protection, while electric underfloor heating does not use valves. This feature can only be used in hydronic applications. Valve protection The valve protection can be enabled or disabled by tapping the toggle switch (A) on the valve protection setting. NOTE: Activate output every two weeks to prevent valve calcification. It only supports Enable/Disable feature. Settings Sensors Settings Temperature Detection Air Temperature Temperature Calibration ? Valve Protection Settings Valve Protection Child Protection Settings Child Lock Screen Brightness Settings Active Brightness Level +0.1 C A 100% Idle Brightness Level 100% Screen Active Duration 1 Min(s) 0 Sec(s) 22 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A Rated power settings The thermostat does not include any hardware to monitor the power output of the heating load. To provide power monitoring functionality, the rated power value (W) of the connected heating load needs to be entered in the app. You can view the power consumption (W) on the app. Rated power value To monitor instant power value information in the app: Tap Rated Power Value On the pop-up menu enter the rated power value (A) and then tap Save (B). Settings Sensors Settings Temperature Detection Air Temperature Temperature Calibration ? -9.0 C Rated Power Settings Rated Power Value ? 0 W Child Protection SRetatitnegds Power Value Child Lock Screen BrigChtannescseSl ettings Active Brightness Level Save 100% A B Idle Brightness Level 100% Screen Active Duration 1 Min(s) 0 Sec(s) Child lock settings The child lock helps to prevent children from operating the thermostat. When the Child Lock is enabled, thermostat can be operated only using the app. To enable/disable the child lock: 1. On the Home page, tap All devices > Thermostat. 2. Tap Settings. 3. Tap the toggle switch (A) to enable/disable the Child Lock settings. Settings Sensors Settings Temperature Detection Air Temperature Temperature Calibration ? Valve Protection Settings Valve Protection Child Protection Settings Child Lock Screen Brightness Settings Active Brightness Level -9.0 C A 100% Idle Brightness Level 100% Screen Active Duration 1 Min(s) 0 Sec(s) NOTE: By enabling the child lock, thermostat can only be controlled using the app and not change the temperature setpoint value using physical device. DUG_ZB Thermostat 16 A_ELKO-00 23 Smart ZB Thermostat 16 A Screen brightness settings You can increase/decrease the LED brightness on the thermostat using the app. Settings Sensors Settings Temperature Detection Air Temperature Temperature Calibration ? Rated Power Settings Rated Power Value ? Child Protection Settings Child Lock Screen Brightness Settings Active Brightness Level -9.0 C 0 W 100% Idle Brightness Level 100% Screen Active Duration 1 Min(s) 0 Sec(s) A B C Active brightness level You can configure the brightness of the LEDs when the thermostat is active (during interaction): 1. Tap Active Brightness Level (A). 2. On the slide up menu, adjust the desired brightness level then tap Save. NOTE: · Default active screen brightness is 100% · The screen brightness range is 1%~100%, and the setting accuracy is 1%. Idle brightness level You can configure the brightness of the LEDs when thermostat is inactive (after time-out of screen active brightness). 1. Tap Idle Brightness Level (B). 2. On the slide up menu, adjust the desired brightness level then tap Save. NOTE: · Default idle screen brightness is 0% · The screen brightness range is 0%~100% and it should not be more than active brightness level. Screen active duration The thermostat can be configured to set a timeout for the LED when it is active. 1. Tap Screen Active Duration (C). 2. On the slide up menu, select required active duration: · 5 Secs · 10 Secs · 30 Secs · 45 Secs · Customized Duration: use +/- or drag the sliding bar to change the Active Duration, which ranges from 1 minute to 60 minutes. NOTE: Default screen active duration is 60 s. NOTE: In the event that the thermostat is removed from the ELKO system, the brightness setting will be retain. 24 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A Using the device The control panel of the thermostat(s) allows you to view and adjust the temperature and access various settings. When a thermostat is commissioned and assigned to a room, an individual group called Thermostat is automatically created in the home page. By default, individual thermostat will not appear on the home page. To change this setting, refer to individual thermostat visibility on home page, page 27. NOTE: Control panel always displays the thermostat's current state Thermostat control panel On the thermostat control panel page, you can see the following: · Power button (A) · The current temperature value (B) · The setpoint temperature value (C) · The sliding bar to adjust the temperature setpoint (D) · Boost mode, page 29 (E) · History, page 30 (F) · Schedule, page 31 (G) · Settings, page 19 (H) Thermostat A B The Air Temperature setpoint ranger is 4 C~30 C. C 25 E F G H History Schedule Settings D DUG_ZB Thermostat 16 A_ELKO-00 25 Smart ZB Thermostat 16 A Individual thermostat control panel On the individual thermostat control panel page, you can see the following: NOTE: This control panel will not have the slider bar as you cannot control the temperature of the thermostats individually. To adjust the setpoint, check the thermostat control panel. · The current temperature value (A) · The setpoint temperature value (B) · History, page 30 (C) Smart ZB Thermostat 16A Please ensure that the CFMT is assigned to a room before using it. A B 25 C History NOTE: On screen message in control panel · P1P6: The air temperature range setpoint range is 4°C ~ 30°C · P7P8: The floor temperature range setpoint range is 10°C ~ 40° · P9: The regulator mode setpoint range is 0 ~ 10 26 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A Individual thermostat visibility on home page The individual thermostats will not appear on the home page by default. Using the app, you can change the default settings to adjust the visibility according to your preferences. To change the settings: 1. On the Home page, tap All devices > Thermostat. 2. Tap to display more details. 3. Tap thetoggle switch (A) to enable or disable the Show Individual CFMT in Home Page option. NOTE: · By enabling, individual thermostat is shown in the home page and disabling it hides the individual thermostat in home page. · Tapping for more menu in the individual thermostat control panel, allows you to update firmware and remove the device from the system. More Thermostat Moment and Automation Others FAQ and Feedback Show individual CFMT in Home Page A Setting the room temperature manually The room temperature can be increased/decreased manually by pressing the touch button of the thermostat. · Press the "+" button to increase the temperature setpoint. · Press the "" button to decrease the temperature setpoint. DUG_ZB Thermostat 16 A_ELKO-00 27 Smart ZB Thermostat 16 A Setting the room temperature using app By using the ELKO Smart app, you can set the desired room temperature. To set the room temperature: NOTE: You can only adjust the room temperature through the control panel of the thermostat. 1. On the Home page, tap All devices > Thermostat. 2. On the control panel page, you can do either of the following to adjust the temperature (A): Tap "+" or "" sign to increase/decrease the temperature setpoint. Drag the sliding bar up/down to increase/decrease the temperature setpoint. Thermostat The Air Temperature setpoint ranger is 4 C~30 C. A 25 History Schedule Settings NOTE: · Each "+/" tapping will increase or decrease the temperature setpoint by 0.5 °C. · The indicates that the room/current temperature is below the desired temperature (set point), so the heating is on. · The indicates that the room/current temperature is above the desired temperature (set point), so the heating is off. TIP: Tapping you can enable or disable the boost time. 28 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A Using the boost mode Using the boost mode, the setpoint is increased by 2 ºC from the current room temperature setpoint. To use the boost mode: 1. On the Home page, tap All devices > Thermostat. 2. On the device control panel page, tap . 3. In the slide-up menu, select the Boost Duration (A) and than tap Save. NOTE: · The boost duration is set to 1 hour by default. · Changing setpoint using during boost mode will cancel boost mode on the app · The boost mode will stop automatically when the boost duration is completed. · If the current temperature is 28.5 ºC - 29.5 ºC (for P1P6) or 38.5 ºC 39.5 ºC (for P7P8), then the boost mode will set the temperature to the maximum temperature 4. To turn off the boost mode manually, go back to the control panel page and tap . 5. In the slide-up menu, tap Off (B) and then tap Save. Thermostat The Air Temperature setpoint ranger is 4 C~30 C. 30 Boost Duration 30 Mins 1 Hr 2 Hrs History Schedule SeCttainngcsel 3 Hrs Save A B NOTE: By the end of the time counting down, the boost will be stopped automatically. If the boost feature has been turned on, and in this period there are one or more Schedule or Moment/Automation actions, the system will stop the current Boost action immediately, and perform the new actions (the new action always has a higher priority than the current action). DUG_ZB Thermostat 16 A_ELKO-00 29 Smart ZB Thermostat 16 A Schedule actions within boost period When boost mode is enabled during this period, the system will temporarily stop the scheduled actions and only perform the boost operation until the boost duration is over. The new action always has a higher priority than the current action. As a result, boost mode will be activated even when the scheduled action is in progress and the system will stop the schedule. To view the temperature changes during the boost operation, go to Checking the device history, page 30. Checking the device history Using the app, you can monitor the temperature changes by accessing the device history. To see the device history of the group thermostats: 1. On the Home page, tap All devices > Thermostat. 2. On the device control panel page, tap History. 3. In the History page, you can see the Temperature and Energy changes in Day (A), Week (B), Month (C), or Year (D) view. B A History Temperature Energy Day Week Month Year 9 Sep 2022 c 20 History CB DA Temperature Day Week Energy Month Year E 9 Dec 2020 2.5 KWh kWh 1 C D E 15 0.5 10 11:00 0.2KWh 5 0 00:00 06:00 12:00 Time 18:00 23:00 0 00:00 06:00 12:00 Time 18:00 23:00 NOTE: Temperature and energy tabs are available for preset P4,P5,P6, and P8. For preset P1,P2,P3, and P7 only temperature tab is visible and for P9 only energy tab is visible. NOTE: You can adjust the date, week, month, or year using " " (E). Alternatively, navigate to Home > All devices >Smart ZB Thermostat 16 A > History to check the device history of the individual Thermostats. 30 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A Creating a schedule The heating system is fully controlled and triggered by your schedule. Once the schedule is set, your system will follow the active schedule. You can create or modify the schedules at any time. To create a schedule: 1. On the Home page, tap All devices > Thermostat. 2. Tap Schedule > Add Schedule to add a schedule. 3. Set the time (A). 4. Tap Repeat (B), select the days you want to set the schedule. 5. Tap Note (C), enter the note and tap Confirm. 6. Tap the toggle switch (D) to turn on the Notification for the schedule. The app will send a notification that the scheduled task is executed at the time of schedule. 7. In the Thermostat section, you can adjust the temperature (E) for the scheduled time. 8. Tap Save. Cancel Add Schedule Save 8 40 B Repeat C Note E Thermostat 10 42 AM 11 43 PM 12 44 A Once D 4 17 30 Note - The Schedule works according to the timezone where device is located. DUG_ZB Thermostat 16 A_ELKO-00 31 Smart ZB Thermostat 16 A Creating a moment A Moment allows you to group multiple actions that are usually done together. Using the ELKO app, you can create moments based on your needs. To create a moment: 1. On the Home page, tap . 2. Go to Moment > + to create a moment. 3. Tap to enter the name of moment (A) and tap Save. TIP: You can choose the cover image that represents your moment by tapping . Cancel Moment settings Save Edit name A Any condition is met Edit name Add Task (0/10) Save 4. In the Action section, tap Add task (B) to open the slide-up menu. 5. In the Add task menu, you can do either or all of the following actions (C): Run the device - Select the devices that you want in a moment Select Automation - Select the automation that you want to enable or disable Delay - Set the delay time NOTE: You can add one or more actions using . 32 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A 6. Tap Run the device > Thermostat to select one or more functions to add in the moment: Temperature Setpoint: Increase the thermostat's temperature according to your requirement (D). Heating Boost: Increase the temperature by setting the boost duration (E). Select function Temperature Setpoint Heating Boost Next D E 7. Once all the actions are set, tap Save. Cancel Moment settings Save My Moment Action (1/80) Group: Themos.. Heating boost:1 hour Show on Home Page Editing a moment To edit a moment: 1. On the Moment tab, locate the moment you want to edit and tap . 2. On the Edit page, you can tap each item (such as dimmer, shutter, delay, temperature, etc.) to change the settings. TIP: · You can add one or more actions using . · To delete an existing action, slide the each item towards left and tap Delete. DUG_ZB Thermostat 16 A_ELKO-00 33 Smart ZB Thermostat 16 A Deleting a moment To delete a moment: 1. On the Moment tab, locate the moment that you want to delete and then tap . 2. Tap Delete and than tap Ok. NOTE: After deleting a moment, the device action can no longer be triggered. Creating an automation An automation allows you to group multiple actions that are usually done together, triggered automatically or at scheduled times. By using the ELKO Smart app, you can create automations based on your needs. To create an automation: 1. On the Home page, tap . 2. Go to Automation > + to create an automation. 3. Tap to enter the name of automation (A) and tap Save. TIP: You can choose the cover image that represents your automation by tapping . Cancel Automation settings Save My Automation A Any condition is met Edit name Add Condition (0/10) Action (ASdadvede 0/80) Add Task All-Day 4. Tap Any condition is met to select any one of the condition type (B): All conditions are met - The automation is triggered when all the conditions are met Any condition is met - The automation is triggered when at least one condition is met 34 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A 5. Tap Add Condition to open the slide-up menu. 6. In the Add Condition menu, you can do either or all of the following options (C): When weather changes - Select the various weather settings. Schedule - Set the time and day. When device status changes - Select the device and it's function. Note: You can add one or more conditions using . Cancel Automation settings Save My Automation Any condition is met (0/10) Add Condition Add Condition C 7. Tap When device status changes > Thermostats > Temperature and set the temperature (D) and the condition (E). Temperature Next E 12.00 D 0.00 C 50.00 C 8. Tap Add task to open the slide-up menu. DUG_ZB Thermostat 16 A_ELKO-00 35 Smart ZB Thermostat 16 A 9. In the Add task menu, you can do either or all of the following options (F): Run the device - Select the devices that you want to be triggered. Moment or Automation - Select the moment which you want to trigger or select the automation that you want to enable or disable. Send notification - Turn On notification for the automation. Delay - Set the delay time. NOTE: You can add one or more actions using . Cancel Automation settings Save My Automation Any condition is met (0/10) Add Condition Action (Added 0/80) Add task Add Task All-Day F 10. Tap on Effective period to set the time range for the automation. You can select any one of the following (G) and tap Next: All-day - 24 hours. Daytime - From sunrise to sunset. Night - From sunset to sunrise. Custom - User defined time period. Next 24 hours From sunrise to sunset G From sunset to sunrise Custom City 11. Once all the actions and conditions are set, tap Save. Once the automation is saved, it is visible on the Automation tab. You can tap the toggle switch on the automation to enable it. Example of an automation This demonstration shows you how to create an automation to turn on the Thermostat setpoint to 20 °C when the outdoor temperature is less than 15 °C . 1. Go to Automation > + to create an automation. 2. Tap to enter the name of automation and tap Save. TIP: You can choose the cover image that represents your automation by tapping . 36 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A 3. Tap Add Condition > When weather changes > Outdoor Temperature. 4. Select the outdoor temperature value (A), the condition (B) and tap Next. TIP: You can set the outdoor temperature value as 15 °C and the condition as < (less than). Outdoor Temperature Next City B 0 4 + 1 5C -2 6 A 5. Tap Add task > Run the device and select Radiator Thermostats. 6. Tap Thermostat Set Point and set the temperature as 20 °C (C). Select function Next Temperature Setpoint Heating Boost C Temperature Setpoint 20.0 Cancel Save 7. In the Automation Settings page, tap Save. Cancel Automation settings Save My Automation Any condition is met (1/10) Outdoor Temperature:<10 C Action (1/80) Group: Themos.. Temperature Setpoint:. All-Day Once the automation is saved, it is visible on the Automation tab. You can tap the toggle switch on the automation to enable it. DUG_ZB Thermostat 16 A_ELKO-00 37 Smart ZB Thermostat 16 A Editing an automation To edit an automation: 1. On the Automation tab, locate the automation you want to edit and tap . 2. On the Edit page, you can tap each item (such as dimmer, shutter, delay, temperature, etc.) to change the settings. TIP: · You can add one or more actions using . · To delete an existing condition or action, slide each item towards left and tap Delete. Deleting an automation To delete an automation: 1. On the Automation tab, locate the automation that you want to delete and then tap . 2. Tap Delete and tap Ok. NOTE: After deleting an automation, the device action can no longer be triggered. Removing the device from ELKO system You can remove a device from the device list using the ELKO Smart app. NOTE: You can only remove the device by accessing the individual thermostat control page. If it is not visible on the home page, you can enable it in the group thermostat. Refer individual thermostat visibility, page 27. To remove a device: 1. On the Home page, tap All devices and select the individual Smart ZB Thermostat 16 A which needs to be removed. 2. Tap to display more details. 3. Tap Remove Device (A) and tap Confirm. More Smart ZB Thermostat 16A Device information Others Remove Device A TIP: On the home page, you can tap and hold the individual Smart ZB Thermostat 16 A to remove the device. NOTE: Setting parameters will be retained when the thermostat is removed from the ELKO system. 38 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A Resetting the device You can manually reset the thermostat to factory settings or soft reset. Soft reset Press and hold the O touch button > 20 s. The thermostat flashes "Sr", indicating soft reset, and it is selected when the button is released. The `Sr' will flash to confirm the soft rest. > 20 s NOTE: To cancel the soft reset, press and hold the O button for > 30 s. This reverts the thermostat's UI back to its previous state before the touch button is pressed, with no change in a functional state. > 30 s A soft reset will: · Delete all Zigbee connection details. · Delete all cloud and account details maintained by the device to allow reregistration. · Revert to the default setpoint in manual control. · Maintain all Factory settings e.g. MAC address. · Maintain the installer configuration of the device to ensure proper functioning until and after rejoining/re-registration. DUG_ZB Thermostat 16 A_ELKO-00 39 Smart ZB Thermostat 16 A Factory reset In reset selection, press and hold the O touch button until thermostat flashes "Fr", indicating factory reset, and it is selected when the button is released. The `Fr' will flash on the matrix display to confirm the factory reset and the thermostat resets to factory defaults and after 5 s it returns to preset, page 7. > 25 s NOTE: To cancel the factory reset, press and hold the O button for > 30 s. This reverts the thermostat's UI back to its previous state before the touch button is pressed, with no change in a functional state. > 30 s A factory reset will: · Delete all Zigbee connection details. · Delete all configuration data. · Delete all schedules information. · Revert to the default setpoint in manual control. · Maintain all Factory settings e.g. MAC address. 40 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A LED Indications Pairing the device Status Pairing in progress User Interaction Successful joining network Fails to join the network Presetting the device Status Enter preset selection User Interaction Modify preset selection Setting a sensor type Status Floor sensor type selection User Interaction Description The thermostat matrix display flashes "Jn" to indicate joining is initiated when the thermostat O touch button is pressed and held for > 3 s. The thermostat matrix display flashes a green LED when the thermostat successfully joins a network. The thermostat matrix display flashes a red LED when the thermostat fails to join the network. Description By default, thermostat matrix display flashes "P5" if there is no external sensor connected, or "P8" if there is any external sensor connected when the thermostat is first powered on or after a factory reset. The default preset value can be modified by simultaneously pressing "O" and "+" for 2 s to enter advanced settings menu In advance setting menu the thermostat matrix display flashes "P1" or "P2...P9" when +/ button is pressed. Note: When + button is pressed, preset increases by one; similarly, the preset decreases by one when the button is pressed. For more information, refer to the section presetting the device, page 7. Description The thermostat matrix display the floor sensor type and LED flashes blue. DUG_ZB Thermostat 16 A_ELKO-00 41 Setting a sensor type (Continued) Floor sensor calibration. Smart ZB Thermostat 16 A The thermostat matrix display calibration value and LED flashes purple. Floor temperature maximum limit Resetting the device Status Soft reset User Interaction Factory reset The thermostat matrix display maximum temperature limit and red. LED flashes Description A solid "Sr" LED is displayed on the thermostat matrix display until the user releases the O button, then "Sr" flashes. For more information, refer to the section Resetting the device, page 39. A solid "Fr" LED is displayed on the thermostat matrix display until the user releases the O button, then "Fr" flashes. For more information, refer to the section Resetting the device, page 39. 42 DUG_ZB Thermostat 16 A_ELKO-00 Smart ZB Thermostat 16 A Showing demand - temperature control modes Status Heating demand User Interaction Temperature display Status Temperature below minimum display value OR Temperature reading error. User Interaction Temperature above maximum display value Description The matrix display a solid red LED to indicate the thermostat is heating when the setpoint is higher than the current room temperature. Description Note: The thermostat matrix displays temperature limits -9 °C to 99 °C. The thermostat matrix display flashes "--" When the temperature is below -9 degrees. OR The thermostat matrix display flashes "--" when the thermostat cannot determine the temperature due to an error. Note: The thermostat matrix displays temperature limits -9 °C to 99 °C. The thermostat matrix display flashes "+ +" when the temperature is above 99 degrees. Troubleshooting Symptom The thermostat has gone offline. Unable to join to the ELKO Smart Hub (blinking red LED) Unable to set the room temperature by the app. Possible cause · The thermostat is not On. · The thermostat is no longer in signal range of the Hub. Poor signal between the ELKO Smart Hub and thermostat. The devices have no power (Thermostat/ ELKO Smart Hub/ Wi-Fi® network). ELKO Smart Hub signal is weak or not connected to the Wi-Fi® network. Solution · Turn the thermostat On and Off. · Move the ELKO Smart Hub closer to the thermostat. · Rejoin the thermostat in the app. · Turn on the devices power (Thermostat/ ELKO Smart Hub/ Wi-Fi® network). Check for a Wi-Fi® signal. DUG_ZB Thermostat 16 A_ELKO-00 43 Technical Data Nominal voltage: Maximum current rating Resistive load: Standby: Inductive load: Connecting terminals: Neutral conductor: Ambient temperature: Relative humidity: Temperature accuracy: Temperature measurement resolution: Display: Operating frequency: Max. radio-frequency power transmitted: Communication protocol: Floor sensor types: Protection Class: Working voltage: Over-voltage category: Rated impulse voltage: Pollution degree: CTI rating of insulation components: Material group: Disconnection type: Smart ZB Thermostat 16 A AC 230 V ~, 50 Hz max. 16 A, 3520 W max. 4 A max 0.5 W Screw terminals for max. 2.5 mm², 0.5 Nm Required 0 to 40 °C max. 90% non-condensing max. ±0.5 °C (accross the range of 4 to 30 °C) max. 0.1 °C 7x5 dot matrix, 3 additional LEDs 2.401 GHz to 2.483 GHz < 10 mW Zigbee 3.0 certified 10, 12, 15, 33, 47 (Thermistor resistance values in kOhm. Nominal value at 25 °C) II 230 V III 4 kV 2 175 V IIIa (based on CTI value) 1.B 44 DUG_ZB Thermostat 16 A_ELKO-00 Trademarks This guide makes reference to system and brand names that are trademarks of their relevant owners. · Zigbee® is a registered trademark of the Connectivity Standards Alliance. · Apple® and App Store® are brand names or registered trademarks of Apple Inc. · Google PlayTM Store and AndroidTM are brand names or registered trademarks of Google Inc. · Wi-Fi® is a registered trademark of Wi-Fi Alliance®. Other brands and registered trademarks are the property of their respective owners. ELKO AS Sandstuveien 68, 0680 Oslo Pb 6598 Etterstad, 0607 Oslo Norway +47 67 79 39 00 support@elko.no www.elko.no As standards, specifications, and design change from time to time, please ask for confirmation of the information given in this publication. © 2023 2023 ELKO AS. All rights reserved. DUG_ZB Thermostat 16 A_ELKO-00