PRODUCT MANUAL Aroma diffuser
Bluetooth Instruction
Where to get the app:
Please search for "Home Luxury Scents" in Google Play or App Store.
Note:
- Please make sure that the Bluetooth function is turned on.
- Please make sure that the location function of the mobile phone is turned on.
App Pairing Process:
The app interface guides users through connecting to the device. This typically involves searching for the device, entering a password (factory default: 8888), and then logging in. Users can choose to remember their password.
Visual description of app screens showing device search, password input, and login.
Device Control
The device can be controlled via the "Home Luxury Scents" app, offering features like setting working times, adjusting aroma oil consumption calibration, and managing device settings.
Working Period Setting:
Users can set start and stop working times for the aroma diffuser. The interface allows selection of days (Mon-Sun) and specific times. For example, setting a working period from 00:00 to 23:59 with Grade 4, or 23:58 to 00:01 with Grade 1.
Visual representation of setting start/stop times, selecting days, and choosing concentration grades.
Consumption Calibration:
Consumption is calculated based on continuous machine work with a specific aroma oil viscosity. Users can calibrate this via the app to account for different aroma oils. The app displays Aroma oil amount, Remaining oil, and percentage. Calibration involves measuring remaining oil and inputting the value into the app.
Amend Password:
Users can change the device password. This requires entering the current password, the new password, and confirming the new password. If the password is forgotten, pressing the reset button restores factory settings (default password: 8888).
Visuals showing the process of changing the password.
Specification
Feature | Details |
---|---|
Model | HLS450+ |
Size | 227*65*86mm |
Bottle Capacity | 100ml |
Input Voltage | AC100V-240V 50/60Hz |
Power Consumption | 3W |
Coverage Area | 30㎡ / 100m³ / 19000ft³ |
Net Weight (N.W.) | 0.39kg |
Material | Plastic |
PCB Version | AAAA |
Equipment Version | AAAA |
APP Version | AAAA |
Parts Identification:
The device comprises a bottle, bottle cap, card pin, manual, plug, reset button, pilot lamp, and nozzle.
Diagram showing the physical components of the aroma diffuser: bottle, bottle cap, card pin, manual, plug, reset button, pilot lamp, nozzle.
How to Refill Essential Oils
Follow these steps to refill the essential oil:
- Unscrew the bottom cover.
- Unscrew the bottle cap to fill with the desired oil fragrance.
- Guide the tube into the bottle and screw the bottle into the base of the diffuser unit. (Note: There is a filter in the tube; do not remove it.)
- Screw the bottom cover onto the base of the diffuser unit.
- Plug in the unit to the outlet. Ensure the unit is always upright to avoid leakage. Turn the plug clockwise if necessary.
Visual guide illustrating the steps for refilling essential oils, from unscrewing the cover to plugging in the unit.
Operating Instructions
The device is controlled by the APP, making it more convenient and intelligent.
Reset Function:
- Short Press: Restores the original password "8888".
- Long Press: Restores factory settings.
Indicator Light:
When the indicator light is on, it signifies that the machine is operating during its set working period.
Important Notes:
- Do not mix fragrances with any other liquid.
- Do not remove any piece or part of the diffuser.
- This diffuser is intended for use only with the company's Scent Collection oils.
Concentration and Consumption
The table below details different concentration grades, their working and stop times, and estimated consumption rates.
Grade | Work Time(s) | Stop Time(s) | Consumption(ml/h) |
---|---|---|---|
G1 | 15s | 210s | 0.09 |
G2 | 15s | 100s | 0.19 |
G3 | 15s | 65s | 0.30 |
G4 | 15s | 45s | 0.40 |
Customized | 3-15s | 45-900s | Varies |
Notes:
- The working time for each grade listed above is 15 seconds.
- Consumption rates may vary depending on the grade and the type of oil used.
Troubleshooting
Consult this guide to diagnose and resolve common issues.
Breakdown | Solution |
---|---|
Does not diffuse | - Check if the correct mode is selected. - Ensure the machine is not in a "Non-Working period". - Check if the air pump is damaged; replace if necessary. - Verify the tube is securely connected. - The atomizing core might be blocked; clean with alcohol or replace atomizing heads. |
Low diffuse | - Check for damaged, loose, or missing gaskets. - Ensure the tube is properly connected. - Verify the oil bottle is securely fitted. - Check if the gasket in the atomized head is damaged, loose, or missing. |
Oil spill / Oil sprinkle | - The atomized head may be damaged; replace it. - Ensure the air pump is securely attached; retighten if loose. - The machine might be tilted or laid flat; keep it vertical. |
Abnormal noise | - The air pump may be damaged; replace it. |
Equipment Cleaning
Clean the machine when:
- You are changing to a different essential oil.
- The atomization volume has become weak.
Cleaning Steps:
- Pull out the atomized head.
- In a larger container, fill with industrial alcohol. Soak the atomized head and the bottle for 5-10 minutes.
- Allow the atomized head and the bottle to dry completely.
Warning
Please read the user manual before operation and maintenance.
- Keep the machine vertical; laying flat may cause oil overflow.
- Ensure the machine is empty of essential oil before transportation.
- Tighten the oil bottle securely before use.
- Clean the machine with alcohol every 1-2 months.
- Do NOT modify, disassemble, or repair the machine. Contact technical personnel for any failures.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved by the manufacturer could void your authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RF Exposure Information:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.