HLS3500+ Product Manual
Home Luxury Scents
Product Overview
The HLS1000+ is a scent diffuser designed for home and commercial use. It is important to follow the guidelines in this manual for safe and effective operation.
Key Features:
- Model: HLS1000+
- Dimensions: 196.8*167.2*106.0mm
- Bottle Capacity: 180ml
- Power Adapter Input: 100-240V~50/60Hz 1.0A
- Power Adapter Output: 12V ⎓ 1.0A
- Input: 12V ⎓ 1.0A
- Power: 4.5W
- Coverage: 360m²/1080m³/38139.12ft³
- Net Weight: 0.928kg
- Material: Plastic
Important Usage Notes:
- Do not mix fragrance with any other liquid.
- Do not remove any part of the diffuser.
- This diffuser is only for use with Home Luxury Scents' Scent Collection.
Overview Diagram
The diffuser consists of the following parts:
- Lifting handle
- Hanging hole
- Pilot lamp
- Reset button
- Nozzle
- Diffuser head
- Bottle
- Bottle mounting screw
- Cap
- Bracket
- Rubber backing
- Manual
- DC connector
Bluetooth Instruction
To control the diffuser via Bluetooth, download the "Home Luxury Scents" app from Google Play or the App Store.
App Usage:
- Ensure Bluetooth is turned on your mobile device.
- Ensure the location function is turned on your mobile device.
- Search for the device within the app.
- Enter the default password '8888' to log in. The password can be changed later.
Device Control Features:
- Amend device name
- Working period setting: Set start and stop times for operation.
- Concentration grade: Adjust the scent intensity.
- Time switch: Customize working periods.
Password Reset: If you forget your password, press the reset button to restore factory settings. The default password is '8888'.
Concentration and Consumption
The table below shows different concentration grades (G1-G20) and their corresponding work times, stop times, and consumption rates.
Grade | Work time(s) | Stop time(s) | Consumption(g/h) |
---|---|---|---|
G1 | 15 | 300 | 0.09 |
G2 | 15 | 150 | - |
G3 | 20 | 120 | - |
G4 | 20 | 85 | - |
G5 | 25 | 80 | 0.45 |
G6 | 30 | 75 | - |
G7 | 30 | 60 | - |
G8 | 30 | 50 | - |
G9 | 30 | 40 | - |
G10 | 30 | 33 | 0.9 |
G11 | 33 | 30 | - |
G12 | 40 | 30 | - |
G13 | 50 | 30 | - |
G14 | 60 | 30 | - |
G15 | 75 | 30 | 1.35 |
G16 | 80 | 25 | - |
G17 | 85 | 20 | - |
G18 | 120 | 20 | - |
G19 | 150 | 15 | - |
G20 | 300 | 15 | 1.8 |
Note: Consumption rates are based on testing with a specific essential oil and may vary with different oils.
How to Install and Use
- Press down to release the atomized head.
- Rotate clockwise to unscrew the essential oil bottle and add essential oil.
- Align the bottle with the correct position and press down to secure it in place.
Wall Mounting:
- Drill 3 screws into the wall.
- Hang the machine onto the screws.
Amend Password
Users can change their password through the app. If the password is forgotten, use the reset button to revert to factory settings (default password: 8888).
Direction for Use
This diffuser is ideal for various locations such as hotels, conference rooms, malls, major retailers, bars, SPAS, and business places where a pleasant fragrance experience is desired.
Warning and Caution
Warning:
- Read the user manual before operation and maintenance.
- Keep the machine vertical; laying it flat may cause oil overflow.
- Ensure the machine is empty of essential oil before transportation.
- Tighten the oil bottle securely before use.
- Clean the machine with alcohol every 1-2 months.
- Do not modify, disassemble, or repair the machine yourself. Contact technical personnel for any issues.
- This appliance is not intended for use by persons with reduced physical, sensory, or mental capabilities, or lack of experience, unless supervised.
- Children should be supervised to ensure they do not play with the appliance.
- Use only the recommended vaporizing medium to avoid toxic or fire risks.
Caution:
- Do not modify, disassemble, or repair the machine arbitrarily. Contact a technician for any failures.
- Do not damage the power cord; avoid bending, yanking, or placing heavy loads on it.
- Do not use a damaged plug or an unmatched socket.
- Do not wet the machine or the plug.
- Do not use overloaded power sockets or wires.
- Do not touch the wire or product shell during thunderstorms.
- Do not disassemble the machine while it is operating.
Troubleshooting
Breakdown | Solution |
---|---|
Does not diffuse |
|
Low diffuse |
|
Oil spill |
|
Abnormal noise |
|
Equipment Cleaning
Clean the machine when changing essential oils or if the atomization volume weakens.
Cleaning Steps:
- Pull out the atomized head.
- Fill a larger container with industrial alcohol. Soak the atomized head and bottle for 5-10 minutes.
- Allow the atomizer head and bottle to dry completely.
Regulatory Information
ISED Statement
This device complies with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation. The digital apparatus complies with Canadian CAN ICES-3 (B)/NMB-3(B). This device meets exemption from routine evaluation limits in RSS 102 and compliance with RSS 102 RF exposure. Users can obtain Canadian information on RF exposure and compliance. This equipment complies with Canada radiation exposure limits for an uncontrolled environment. It should be installed and operated with a minimum distance of 20cm between the radiator and your body.
FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. If this equipment causes harmful interference to radio or television reception, try to correct it by reorienting the receiving antenna, increasing the separation between the equipment and receiver, connecting the equipment to an outlet on a different circuit, or consulting a dealer or technician. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with FCC radiation exposure limits for an uncontrolled environment. It should be installed and operated with a minimum distance of 20cm between the radiator and your body.