PRODUCT INFORMATION
CP86 Series CHICAGO PNEUMATIC BATTERY TORQUE WRENCH
A Chicago Pneumatic battery torque wrench, red and black, shown with a smartphone displaying the CPLinQ application.
- +/- 4%
- ? Connected*
- ? Data collection*
- ⚙️ Sequence programming*
- ? Tool lock. Error proof*
- ? Application library*
* C or CQ version only
** Based on hard joint 15° at nominal torque
Model | Torque Range |
---|---|
CP8613 | Up to 1300 Nm / 960 ft.lbs |
CP8626 | Up to 2600 Nm / 1900 ft.lbs |
CP8641 | Up to 4100 Nm / 3100 ft.lbs |
CP8681 | Up to 8100 Nm / 5975 ft.lbs |
Product Description
Diagram of the torque wrench with numbered parts: 1. Second trigger, 2. Principle trigger, 3. Display screen, 4. Settings buttons, 5. Reporting LEDs, 6. Reverse button, 7. Reaction bar s-type (delivered with the tool).
Connected Version
To unblock functionalities of CP86 connected versions C and CQ, download CPLinQ to your device and connect your tool to the CPLinQ app.
Installation & Operating Instructions
Battery Installation
For Battery CP36XP25 (8940176068): Battery wake up procedure involves removing the white protective sticker and plugging the battery into the CP charger CP18-36CH (8940176069).
Reaction Bar & Socket
Instructions for attaching the reaction bar and socket.
Starting the Tool
Starting the Tool
Fit the tool with a suitable socket. Set the appropriate program on the tool. Hold the tool by the handle, place the reaction bar on a suitable reaction point, and apply to the fastener to be tightened.
Warnings
WARNING Risk of Injury: As reaction force increases with tightening torque, there is a risk of severe bodily injury from unexpected tool behavior. Ensure the tool is in perfect working order.
WARNING Risk of Burns: The motor may heat up during heavy duty cycles. Wear gloves.
WARNING Crushing Hazard: Perform a check of the tool's rotational direction before starting. An unexpected direction can cause bodily injury or property damage. Ensure the rotational direction is correct before starting. Keep hands away from the reaction bar while the tool is in use. Press triggers to start the tool.
Operating the Tool
Operating the Tool
Overview of tool controls and display: Second start button, Action for button, Tool display showing 560 N.m, Battery level indicator, Bluetooth connection status (for C, CQ versions), Application information display, and buttons for menu navigation and action.
Torque Set Up
Demonstrates FORWARD and REVERSE operations, including setting MAX TORQUE.
Menus
Stand Alone Tools Menu
Step-by-step guide for navigating the tool's menu when operating in stand-alone mode, including accessing Maintenance, Tool Infos, and Select Unit options.
Maintenance Menu
Details on accessing and viewing maintenance information, such as operating time (e.g., 17 min/1 h) and drop counts (e.g., 1/5).
Tools Information Menu
Guide to accessing tool information, including Model (e.g., CP8613), Serial Number (e.g., A-00513-202012), and Soft versions (e.g., 0.18.0-7032R).
Units Selection Menu
Instructions for selecting measurement units, such as N.m or ft.lb, within the tool's interface.
Troubleshooting
Troubleshooting
Issue | Description | Solution |
---|---|---|
? TRIGGER ORDER | Triggers used in bad order. | Press second trigger first, then main trigger until end of tightening. |
❌ Trigger Released | One trigger released during tightening. | Maintain both triggers until end of tightening. |
? TOOL OVERLOAD | Torque higher than maximum authorized or angle not achievable due to tool capacity exceeded. | |
? REHIT DETECTED | Tool detected a rehit (tightening an already tightened bolt). | |
⏱️ OPERATING TIME MAINTENANCE | Nutrunner needs maintenance due to time of operation. | |
⬇️ DROP MAINTENANCE | Nutrunner needs maintenance due to too many drops. | |
⬆️ FORWARD MAINTENANCE | Nutrunner needs maintenance due to number of tightening cycles. | |
⬇️ REVERSE MAINTENANCE | Nutrunner needs maintenance due to number of untightening cycles. | |
? LOW BATTERY | Level of battery is under 25%. | Replace battery by fully loaded battery as soon as possible. |
? EMPTY BATTERY | Level of battery is under 5%. | Replace battery by fully loaded battery; tool will turn off. |
⚠️ BATTERY ERROR | Tool is unable to communicate with the battery. | 1. Check if using the correct Battery (8940176068). 2. If problem persists, contact CP representative. |
?️ TEMPERATURE ERROR | Tool is out of functional temperature range. | 1. Wait for the tool to cool down. 2. Reduce duty cycle. 3. If problem persists, contact CP representative. |
Tool doesn't start | Check Battery is awake, check Battery charge level. If problem persists, contact CP representative. | |
Your tool cannot connect to CPLinQ | Check Bluetooth is active on your terminal. If problem persists, contact CP representative. | |
⚡ FLASH ERROR / ? FAN ISSUE / ? MEMORY ERROR / ⚙️ DRIVE ERROR | Tool system issue. | Contact service center. |
Service & Maintenance
Service & Maintenance
Overhaul and preventive maintenance are recommended at regular intervals and should be performed by qualified personnel only. For information on Products, Accessories, Spare Parts, and exploded views, visit the CP website at www.cp.com. Using spare parts not originally supplied by the manufacturer may lead to reduced performance, increased maintenance, higher vibration levels, and cancellation of manufacturer liability. For tool calibration or other servicing operations, refer to your local service center.