SHP-DH537 Smart Door Lock User Manual
Model Number: SHP-DH537
Additional Functions and Setting Method
Dual Authentication Function
When configured, the user must consecutively authenticate both password and keytag to open the door, reinforcing the security system. This mode can only be enabled when more than one keytag is registered. Dual authentication is set to Off by default.
Auto Lock Time Setting Function
Auto lock time can be configured and adjusted from 1 to 9 seconds. The default setting is 1 second.
Volume Settings
Configure the volume for system sounds and keypad entry. Open the battery cover on the interior unit to adjust the volume using the control switch. The default setting is [1]. Options include [0] Mute (Alarm excluded) and [2] Max. volume.
To configure or disable additional functions, open the battery cover on the interior unit and press the [Register] button. Then, press the security button [B] on the exterior keypad to enter configuration mode. Refer to the table (not provided in text) to select a function and press the Register button on the interior unit to suspend configuration.
- Option: Door to exit locked room if the door has been closed within the default time (within 1 minute) in configuration mode.
Privacy Mode Function
This function restricts the door from being opened from the outside, suitable for evenings when family members have returned or for personal privacy. The door lock cannot be opened from the outside via any authentication method when this function is enabled. Use with caution if children are indoors.
- Configure: Press the [CLOSIS] button on the interior unit for 3 seconds while the door lock is locked.
- Disable: The function is immediately disabled when the door is opened from the inside.
Anti-Tampering Function
The door lock operator is suspended for 3 minutes after 5 consecutive authentication failures (password or keytag). The door triggers an alarm and its operation is suspended.
Intrusion Detection Function
The door lock triggers an alarm if the door is forcefully opened from the inside or outside while locked. The door opening sensor detects intrusion, triggering the alarm for 5 minutes.
High Temperature Alarm Function
The alarm system activates when the temperature sensor detects an abnormal increase in indoor temperature (approx. 60°C ± 10°C). The LED on the [CLOSIS] button flashes for 15 seconds. The door lock is automatically disabled after the alarm turns off and restores to normal when the indoor temperature drops.
How to Use Security Functions
Randomizer Function
Enter two random digits displayed, followed by your password for authentication, to prevent password leaks. The Randomizer function is set to On by default.
Away Mode Function
The Away mode button [A] is activated when the door is locked after the user leaves. Pressing the away mode button [B] within 3 seconds enables the function. After activation, an alarm is triggered if the door is opened from the inside (external alarm, 2D flashes). Recommended for use only when no one is home.
Privacy Mode Function
This function restricts the door from being opened from the outside. It can be configured when all family members have returned home or to protect personal privacy. The door lock cannot be opened from the outside by any authentication method. Exercise caution if a child is present indoors.
- Configure: Press the [CLOSIS] button on the interior unit for 3 seconds with the door lock engaged.
- Disable: The function is immediately disabled when the door is opened from the inside.
Anti-Tampering Function
If authentication fails 5 consecutive times (password or keytag), the door lock operator is suspended for 3 minutes. The door triggers an alarm and operation is suspended.
Intrusion Detection Function
An alarm is triggered if the door is forcefully opened from either side while locked. The door opening sensor detects the intrusion, activating the alarm for 5 minutes.
High Temperature Alarm Function
The alarm activates when the temperature sensor detects a significant rise in indoor temperature (approx. 60°C ± 10°C). The LED on the [CLOSIS] button flashes for 15 seconds. The door lock is automatically disabled after the alarm ceases and will resume normal operation when the indoor temperature decreases.
How to Replace the Battery and Open the Door During an Emergency
Battery Replacement
Replace batteries immediately when the battery replacement alarm melody or LED is activated. Failure to do so may cause the door lock to shut down due to power loss. Remove the interior unit cover by pushing it upwards.
Emergency Door Open
If the door lock is used without replacing batteries after the replacement alarm, it may not operate normally due to insufficient power. Emergency power or mechanical override can be used to open the door.
Emergency Power
Connect a 9V battery to the external power contact point on the exterior unit and perform authentication (password/keytag) to open the door.
Mechanical Override
Use the mechanical override to open the door if the lock fails due to low battery power or circuit errors. Insert the override into the designated hole at the bottom of the exterior unit and turn the key.
Safety Caution
Please read and comply with the following safety precautions to ensure user safety and prevent property damage.
- Do not install or repair the product without authorization.
- The gap between the door and the door frame should not exceed 5mm during installation.
- Avoid installing the door lock in environments exposed to direct sunlight for extended periods.
- Do not apply excessive force or use sharp tools on the door lock buttons.
- Do not operate the product with wet hands. Avoid contact with liquids like water or bleach.
- Wipe the lock with a soft, dry cloth. Do not use water, benzene, or alcohol for cleaning.
- Verify the door is completely locked before leaving home.
- Manage your password carefully and change it regularly to prevent leaks.
- Insert batteries accurately according to the terminal markings (+/-). Incorrect insertion can lead to battery leakage or rupture.
- Battery consumption may vary based on the wireless communication environment; performance may decrease in unfavorable conditions.
- Wireless radio waves or other devices may cause interference, potentially suspending safety-related services.
- Product performance may be affected in high humidity environments.
- Maintain a distance of at least 20cm from the product during use.
Opening the Door from Outside
Keytag
The door opens when a registered keytag makes contact with the keytag sensor.
Master Password & User Password
- Touch the keypad. Two random digits will be displayed (Randomizer function).
- When all keypad buttons are displayed, enter your password (4–12 digits) and press [+] to open the door.
Opening/Closing the Door from Inside
Open Door
Open the door while the fixing button is pressed, or pull down the handle. Alternatively, press the safe handle button and pull down the handle.
Close Door
- Auto lock (A): The door locks automatically when closed (default).
- Manual lock (M): The door does not lock even after being closed, allowing unrestricted access (e.g., for parties or moving).
To configure Auto/Manual Lock: Open the battery cover on the interior unit and configure using the [Auto/Manual Lock] conversion switch.
After enabling manual lock mode, the door will only lock if the [CLOSE] button is pressed from the inside or if the keypad is pressed from the outside.
Registering Authentication Methods
Authentication methods can only be registered when the door is open. Open the battery cover on the interior unit, press the [+] (Register) button, enter the master password, and press [+] again to enter registration mode.
- It is recommended to register authentication methods only when someone is present inside.
- Registration mode differs from previous versions; re-register after pressing the [Register] button if necessary.
Press the [Register] button on the interior unit to suspend registration before completion.
Each setting can be confirmed via the door lock keypad.
Register (Add) Keytag / Delete Individual Keytag / Delete All Keytags
Up to 100 keytags (including passwords) can be registered. Registered keytags can be deleted individually or collectively.
References:
- Press the door open sensor with the door open to artificially close it. Then, open the door with the keytag to check if registration is complete (verify the deadbolt engages).
- Close the door after adding or deleting is complete.
Caution:
- This product only supports keytags provided by Zigbang.
- Warranty is void if the door lock malfunctions due to the use of authentication methods other than the company-prescribed keytags.
Register (Add) User Password / Delete Individual User Password / Delete All User Passwords
Up to 100 passwords (including keytags) can be registered. Registered passwords can be deleted individually or collectively (4–12 digits).
Configuration Examples
The following diagrams illustrate configuration processes:
- To activate Randomizer: [Touch Sensor] > [Home Icon] > [2] [*] > [1] [*]
- To deactivate Randomizer: [Touch Sensor] > [Home Icon] > [2] [*] > [3] [*]
- To activate Dual authentication: [Touch Sensor] > [Home Icon] > [3] [*] > [1] [*]
- To deactivate Dual authentication: [Touch Sensor] > [Home Icon] > [3] [*] > [3] [*]
- Door closing time: [Touch Sensor] > [Home Icon] > [4] [*] > [1] [*]
Registration Status:
- Registration and configuration complete (O)
- Registration and configuration failed (X)
- Add / Register (+)