Wireless-Tek Superic Industrial Switches - Quick Installation Guide

1. Packing Content

2. Appearance Overview

SP3006FM-L2 V1/V2

Front Panel

Features 4 x 10/100/1000 Base-T PoE Ports and 2 x 1000/2500 Base-X SFP Ports.

Side Panel

Includes DC Power Supply Inputs (Main: 44-57V DC, Backup: 44-57V DC), Console Port, Reset Button, and Grounding Point.

LED Indicators & Button

IndicatorStateDescription
POffDevice is power off or failed
PGreen OnDevice power on is normal
SOnDevice on normal operation
SBlinkingDevice initialization
SOffDevice system abnormality
LinkOffPorts link down
LinkOnPorts link up
LinkBlinkingData on TX/RX
PoEOffPoE not working
PoEOnPoE working
PoE (Ports 5, 6)OffPorts link down
PoE (Ports 5, 6)Green OnPorts link up
PoE (Ports 5, 6)Green BlinkingData on TX/RX
Reset ButtonPress over 5s to restore factory default settings.

SP3010FM-L2 V1/V2

Front Panel

Features 8 x 10/100/1000 Base-T PoE Ports and 2 x 1000/2500 Base-X SFP Ports.

Side Panel

Includes DC Power Supply Inputs (Main: 44-57V DC, Backup: 44-57V DC), Console Port, Reset Button, and Grounding Point.

LED Indicators & Button

IndicatorStateDescription
POffDevice is power off or failed
PGreen OnDevice power on is normal
SOnDevice on normal operation
SBlinkingDevice initialization
SOffDevice system abnormality
LinkOffPorts link down
LinkOnPorts link up
LinkBlinkingData on TX/RX
PoEOffPoE not working
PoEOnPoE working
PoE (Ports 9, 10)OffPorts link down
PoE (Ports 9, 10)Green OnPorts link up
PoE (Ports 9, 10)Green BlinkingData on TX/RX
Reset ButtonPress over 5s to restore factory default settings.

SP3012FM-L2 V1/V2

Front Panel

Features 8 x 10/100/1000 Base-T PoE Ports and 4 x 1000/2500 Base-X SFP Ports.

Side Panel

Includes DC Power Supply Inputs (Main: 44-57V DC, Backup: 44-57V DC), Console Port, Reset Button, and Grounding Point.

LED Indicators & Button

IndicatorStateDescription
POffDevice is power off or failed
PGreen OnDevice power on is normal
SOnDevice on normal operation
SBlinkingDevice initialization
SOffDevice system abnormality
LinkOffPorts link down
LinkOnPorts link up
LinkBlinkingData on TX/RX
PoEOffPoE not working
PoEOnPoE working
PoE (Ports 9-12)OffPorts link down
PoE (Ports 9-12)Green OnPorts link up
PoE (Ports 9-12)Green BlinkingData on TX/RX
Reset ButtonPress over 5s to restore factory default settings.

SP3018FM-L2

Front Panel

Features 16 x 10/100/1000 Base-T PoE+ Ports and 2 x 1000/2500 Base-X SFP Ports.

Side Panel

Includes DC Power Supply Inputs (Main: 44-57V DC, Backup: 44-57V DC), Console Port, Reset Button, Grounding Point, and Relay.

LED Indicators & Button

IndicatorStateDescription
POffDevice is power off or failed
PGreen OnDevice power on is normal
SOnDevice on normal operation
SBlinkingDevice initialization
SOffDevice system abnormality
LinkOffPorts link down
LinkOnPorts link up
LinkBlinkingData on TX/RX
PoEOffPoE not working
PoEOnPoE working
PoE (Ports 17, 18)OffPorts link down
PoE (Ports 17, 18)Green OnPorts link up
PoE (Ports 17, 18)Green BlinkingData on TX/RX
Reset ButtonPress over 5s to restore factory default settings.

SP5012FM-L2

Front Panel

Features 8 x 10/100/1000 Base-T PoE+ Ports and 4 x 1000/2500/10000 Base-X SFP Ports.

Side Panel

Includes DC Power Supply Inputs (Main: 44-57V DC, Backup: 44-57V DC), Console Port, Reset Button, Grounding Point, and Relay.

LED Indicators & Button

IndicatorStateDescription
POffDevice is power off or failed
PGreen OnDevice power on is normal
SOnDevice on normal operation
SBlinkingDevice initialization
SOffDevice system abnormality
LinkOffPorts link down
LinkOnPorts link up
LinkBlinkingData on TX/RX
PoEOffPoE not working
PoEOnPoE working
PoE (Ports 9-12)OffPorts link down
PoE (Ports 9-12)Green OnPorts link up
PoE (Ports 9-12)Green BlinkingData on TX/RX
Reset ButtonPress over 5s to restore factory default settings.

S5028FM-16T8C4X-L3

Front Panel

Features 8 x Gigabit Combo Ports, 16 x Gigabit Ethernet Ports, 4 x 10G SFP+ Slots, Console Port, and USB Ports.

Back Panel

Includes AC Power Input (100-240V, 50/60Hz, 1A) with fuse requirement.

LED Indicators & Button

IndicatorStateDescription
POnSwitch is powered on
POffSwitch is powered off or power supply abnormal
SOnDevice on normal operation
SBlinkingDevice initialization
SOffDevice system abnormality
USBOnUSB flash drive detected
USBOffUSB flash drive not inserted or not detected
Copper portsGreen OnPort connected
Copper portsBlinkingData on TX/RX
Copper portsOffPort disconnected
Copper speedYellow OnPort connected at 1000Mbps
Copper speedOffPort connected at 10/100Mbps
FiberOnPort connected
FiberBlinkingData transmission
FiberOffPort disconnected
Reset ButtonPress over 5s to restore factory default settings.

S5028FM-16S8C4X-L3

Front Panel

Features 16 x Gigabit SFP Ports, 8 x Gigabit Combo Ports, 4 x 10G SFP+ Slots, Console Port, and USB Ports.

Back Panel

Includes AC Power Input (100-240V, 50/60Hz, 1A) with fuse requirement.

LED Indicators & Button

IndicatorStateDescription
POnSwitch is powered on
POffSwitch is powered off or power supply abnormal
SOnDevice on normal operation
SBlinkingDevice initialization
SOffDevice system abnormality
USBOnUSB flash drive detected
USBOffUSB flash drive not inserted or not detected
Copper portsGreen OnPort connected
Copper portsBlinkingData on TX/RX
Copper portsOffPort disconnected
Copper speedYellow OnPort connected at 1000Mbps
Copper speedOffPort connected at 10/100Mbps
FiberOnPort connected
FiberBlinkingData transmission
FiberOffPort disconnected
Reset ButtonPress over 5s to restore factory default settings.

3. Installation

DIN-rail Installation

Suitable for Superic L2 series switches.

Desktop Installation

Place the switch on a flat surface.

Rack-Mount Installation

Mount the switch in a standard equipment rack using appropriate accessories.

4. Management

Local Login via Web Browser

  1. Launch a web browser.
  2. Type the default IP address 192.168.0.1 in the address bar.
  3. The login screen will appear. The default username and password are both admin.

Access via Console Cable

Connection Diagram: PC <-> Serial Line <-> Superic Industrial Switch

Steps:

  1. Download and install PuTTY software.
  2. Connect the computer and the switch using the console cable.
  3. Configure the COM port number and baud rate (115200) in PuTTY.

Login via Telnet

Connection Diagram: PC <-> Ethernet Cable <-> Superic Industrial Switch

Steps:

  1. Configure the IP address of your computer to be in the same segment as the switch's management IP address.
  2. Open the command prompt (cmd) window on your computer.
  3. Enter telnet <switch_management_IP_address> (e.g., telnet 192.168.0.1).

Warranty Information

Warranty Terms:

Requirements for Service: Proof of purchase and a complete product serial number are required.

Exclusions: The limited warranty does not cover defects caused by factors other than workmanship or product quality, such as natural disasters, water damage, extreme thermal or environmental conditions, sticker damage, or warranty card loss.

Contact and Support

Wireless-Tek Technology Limited

Address: Building 3, Units 1801-1807, 1812, Huaqiang Era Plaza, Tangwei Community, Fuhai Street, Bao'an District, Shenzhen City, Guangdong Province, China.

Website: www.wireless-tek.com

Tel: 86-0755-32811290

Email: sales@wireless-tek.com

Technical Support: tech@wireless-tek.com

Models: SP3006FM-L2 V1-V2, SP3010FM-L2 V1-V2, SP3012FM-L2 V1-V2, SP3018FM-L2, SP5012FM-L2, S5028FM-16T8C4X-L3, S5028FM-16S8C4X-L3, SP3006FM-L2 V1-V2 Industrial Switch, SP3006FM-L2 V1-V2, Industrial Switch, Switch

File Info : application/pdf, 1 Pages, 1.56MB

PDF preview unavailable. Download the PDF instead.

SP3012FM-L2 V1-QIG-20240926

References

Corel PDF Engine Version 22.1.0.517 CorelDRAW 2020

Related Documents

Preview Outdoor Waterproof PoE Switch WI-PS209-O - Wireless-Tek
Comprehensive guide to the Wireless-Tek WI-PS209-O Outdoor Waterproof PoE Switch, covering installation, networking, technical specifications, and warranty. Ideal for robust outdoor network deployments.
Preview WI-AP210-Lite Quick Installation Guide - Wireless-Tek
Comprehensive quick installation guide for the Wireless-Tek WI-AP210-Lite Cloud-Managed Wireless Ceiling Access Point, covering packing content, appearance, connections, installation, configuration, and FAQs.
Preview Wireless-Tek WI-AP218AX Cloud-Managed Wireless Access Point Quick Installation Guide
A comprehensive guide to installing and configuring the Wireless-Tek WI-AP218AX cloud-managed wireless ceiling access point, covering packing contents, appearance, typical connections, device installation, power supply, configuration methods, cloud management settings, and FAQs.