TÜV Rheinland Test Report: Self-ballasted LED Lamps
Report Number: CN257H0Q 001
Client: IKEA of Sweden AB
Test Item: Self-ballasted LED lamps
Model/Type: LED2411G3NA
FCC ID: FHO-LED2411G3NA
Issue Date: 2025-05-08
General Product Information
Product Function and Intended Use: The EUT (equipment under test) is an ordinary self-ballasted LED lamp for lighting and similar use.
Ratings and System Details:
- Rated input: AC 120 V, 60 Hz, 37 mA
- Rated power: 3.3 W
- RF IC: SiMG301
Independent Operation Modes: The basic operation modes are "ON" and "OFF". The test modes were:
- Mode 1: Warm lighting with the maximum lighting output.
- Mode 2: Warm lighting with the minimum lighting output.
- Mode 3: White lighting with the maximum lighting output.
- Mode 4: White lighting with the minimum lighting output.
Highest Frequency: The highest frequency used in the EUT is 2480 MHz.
Test Setup and Operation Modes
Test Procedure Overview:
- Conducted emission tests were performed on 2025-03-20.
- Radiated emission tests were performed on 2025-03-24 to 2025-03-28.
Test Setup Diagrams:
Conducted Emission Setup: The setup includes the EUT, LISN, Transformer, Power Supply, EMI receiver, and Computer.
Radiated Emission Setup (30 MHz – 1000 MHz): The setup involves the EUT placed on a turntable, a receiving antenna at a 3-meter distance, and absorbers. The antenna polarization was varied (horizontal and vertical).
Radiated Emission Setup (1 GHz – 18 GHz): Similar to the 30-1000 MHz setup, with the antenna at a 3-meter distance.
Test Software: The "Home" APP for iPhone was used.
Auxiliary Equipment:
- Mobile phone: iPhone 15 (Apple)
- Loudspeaker: HomePod mini (Apple)
- Remote control: E2489 (IKEA)
Test Results - Emission
Conducted Emission (0.15 MHz – 30 MHz)
Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ICES-003:2020, ANSI C63.4-2014 and CISPR 16-2-1.
Limits: Quasi-peak and Average limits are specified for the frequency range 0.15-30 MHz.
Bandwidth of EMI receiver: 9 kHz.
Measurement Time: 1 second.
Test Site: Shielded room.
Input Voltage: AC 120 V, 60 Hz.
Ambient Conditions: Temperature: 18.1 °C; Relative humidity: 52.1 %.
Expanded Measurement Uncertainty (k=2): 2.33 dB.
Minimum Margin: 7.97 dB at 0.498750 MHz.
The conducted emission tests were performed on the phase (L1) and neutral (N) lines. Results for Mode 1 (Warm, max output) are detailed in the following tables and spectral diagrams.
Mode 1: Warm lighting, max output
Frequency (MHz) | QuasiPeak (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line | Corr. (dB) |
---|---|---|---|---|---|---|---|
0.462750 | 48.02 | 56.64 | 8.62 | 1000.0 | 9.000 | L1 | 10.3 |
0.496500 | 47.98 | 56.06 | 8.08 | 1000.0 | 9.000 | L1 | 10.3 |
0.530250 | 47.65 | 56.00 | 8.35 | 1000.0 | 9.000 | L1 | 10.3 |
0.564000 | 47.58 | 56.00 | 8.42 | 1000.0 | 9.000 | L1 | 10.3 |
0.595500 | 47.36 | 56.00 | 8.64 | 1000.0 | 9.000 | L1 | 10.3 |
0.629250 | 47.07 | 56.00 | 8.93 | 1000.0 | 9.000 | L1 | 10.3 |
Frequency (MHz) | CAverage (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line | Corr. (dB) |
---|---|---|---|---|---|---|---|
0.426750 | 36.81 | 47.32 | 10.50 | 1000.0 | 9.000 | L1 | 10.3 |
0.460500 | 36.64 | 46.68 | 10.05 | 1000.0 | 9.000 | L1 | 10.3 |
0.492000 | 36.07 | 46.13 | 10.06 | 1000.0 | 9.000 | L1 | 10.3 |
0.521250 | 35.72 | 46.00 | 10.28 | 1000.0 | 9.000 | L1 | 10.3 |
0.552750 | 35.10 | 46.00 | 10.90 | 1000.0 | 9.000 | L1 | 10.3 |
1.095000 | 34.92 | 46.00 | 11.08 | 1000.0 | 9.000 | L1 | 10.7 |
Mode 2: Warm lighting, min output
Frequency (MHz) | QuasiPeak (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line | Corr. (dB) |
---|---|---|---|---|---|---|---|
0.431250 | 48.27 | 57.23 | 8.96 | 1000.0 | 9.000 | L1 | 10.3 |
0.462750 | 47.63 | 56.64 | 9.01 | 1000.0 | 9.000 | L1 | 10.3 |
0.498750 | 47.66 | 56.02 | 8.36 | 1000.0 | 9.000 | L1 | 10.3 |
0.519000 | 47.14 | 56.00 | 8.86 | 1000.0 | 9.000 | L1 | 10.3 |
0.566250 | 46.76 | 56.00 | 9.24 | 1000.0 | 9.000 | L1 | 10.3 |
0.597750 | 47.27 | 56.00 | 8.73 | 1000.0 | 9.000 | L1 | 10.3 |
Frequency (MHz) | CAverage (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line | Corr. (dB) |
---|---|---|---|---|---|---|---|
1.099500 | 33.84 | 46.00 | 12.16 | 1000.0 | 9.000 | L1 | 10.6 |
1.131000 | 33.88 | 46.00 | 12.12 | 1000.0 | 9.000 | L1 | 10.6 |
3.297750 | 26.82 | 46.00 | 19.18 | 1000.0 | 9.000 | L1 | 10.2 |
3.329250 | 31.23 | 46.00 | 14.77 | 1000.0 | 9.000 | L1 | 10.2 |
3.360750 | 31.10 | 46.00 | 14.90 | 1000.0 | 9.000 | L1 | 10.2 |
3.394500 | 28.72 | 46.00 | 17.28 | 1000.0 | 9.000 | L1 | 10.2 |
Detailed results for other modes and lines are available in the original report.
Radiated Emission (30 MHz – 1000 MHz)
Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ICES-003:2020, ANSI C63.4-2014 and CISPR 16-2-3.
Product Classification: Class B.
Limits: Quasi-peak limits (3m distance) are 40 dBμV/m (30-88 MHz), 43.5 dBμV/m (88-216 MHz), and 46 dBμV/m (216-1000 MHz).
Bandwidth of EMI receiver: 120 kHz.
Test Site: Semi-anechoic chamber.
Test Distance: 3 m.
Operational Modes: 4 modes tested (Warm/White lighting, Max/Min output).
Ambient Conditions: Temperature: 22.5 °C; Relative humidity: 48.3 %.
Expanded Measurement Uncertainty (k=2): 5.40 dB.
Minimum Margin: 9.5 dB at 35.820000 MHz.
The tests were conducted with the EUT on an 80 cm wooden support, rotated 360°, and the antenna height varied from 1 m to 4 m. Measurements were taken in both horizontal and vertical polarizations. The results for Mode 1 (Warm, max output) are presented below.
Mode 1: Warm lighting, max output (Horizontal Polarization)
Frequency (MHz) | QuasiPeak (dBμV/m) | Bandwidth (kHz) | Height (cm) | Pol | Azimuth (deg) | Corr. (dB/m) | Margin - QPK (dB) | Limit - QPK (dBμV/m) |
---|---|---|---|---|---|---|---|---|
56.432500 | 19.2 | 120.000 | 150.0 | H | -71.0 | 14.1 | 20.9 | 40.0 |
64.192500 | 18.1 | 120.000 | 200.0 | H | -39.0 | 13.3 | 21.9 | 40.0 |
149.552500 | 18.5 | 120.000 | 200.0 | H | -142.0 | 14.4 | 25.0 | 43.5 |
179.743750 | 18.5 | 120.000 | 150.0 | H | 14.0 | 12.7 | 25.0 | 43.5 |
261.102500 | 16.7 | 120.000 | 150.0 | H | -117.0 | 13.1 | 29.3 | 46.0 |
420.667500 | 20.7 | 120.000 | 150.0 | H | 43.0 | 17.5 | 25.3 | 46.0 |
Mode 1: Warm lighting, max output (Vertical Polarization)
Frequency (MHz) | QuasiPeak (dBμV/m) | Bandwidth (kHz) | Height (cm) | Pol | Azimuth (deg) | Corr. (dB/m) | Margin - QPK (dB) | Limit - QPK (dBμV/m) |
---|---|---|---|---|---|---|---|---|
35.698750 | 28.5 | 120.000 | 200.0 | V | 9.0 | 13.6 | 11.5 | 40.0 |
43.216250 | 28.1 | 120.000 | 200.0 | V | -155.0 | 14.2 | 11.9 | 40.0 |
44.428750 | 28.5 | 120.000 | 150.0 | V | -166.0 | 14.2 | 11.5 | 40.0 |
49.521250 | 26.8 | 120.000 | 100.0 | V | -82.0 | 14.3 | 13.2 | 40.0 |
55.341250 | 22.8 | 120.000 | 150.0 | V | 59.0 | 14.1 | 17.2 | 40.0 |
64.071250 | 22.0 | 120.000 | 100.0 | V | 50.0 | 13.3 | 18.0 | 40.0 |
Detailed results for other modes and polarizations are available in the original report.
Radiated Emission (1 GHz – 18 GHz)
Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ICES-003:2020 and ANSI C63.4-2014 and CISPR 16-2-3.
Product Classification: Class B.
Limits: Peak limits: 74 dBuV/m; Average limits: 54 dBuV/m (3m distance).
Frequency Range: 1 GHz – 18 GHz.
Test Site: Semi-anechoic chamber with RF absorber material.
Test Distance: 3 m.
Operational Modes: 4 modes tested.
Ambient Conditions: Temperature: 17.3 °C; Relative humidity: 50.3 %.
Expanded Measurement Uncertainty (k=2): 5.17 dB (1-6 GHz), 5.12 dB (6-18 GHz).
Minimum Margin: 14.8 dB at 14362.531250 MHz.
The tests were conducted with the EUT on an 80 cm supporting table, rotated 360°, and the antenna height varied from 1 m to 4 m. Measurements were taken in both horizontal and vertical polarizations. The results for Mode 1 (Warm, max output) are presented below.
Mode 1: Warm lighting, max output (Horizontal Polarization)
Frequency (MHz) | MaxPeak (dBμV/m) | Meas. Time (ms) | Bandwidth (kHz) | Height (cm) | Pol | Azimuth (deg) | Corr. (dB/m) | Margin - PK+ (dB) | Limit - PK+ (dBμV/m) |
---|---|---|---|---|---|---|---|---|---|
1736.843750 | 38.8 | 1000.0 | 1000.000 | 150.0 | H | -48.0 | -18.8 | 35.2 | 74.0 |
2439.156250 | 46.1 | 1000.0 | 1000.000 | 150.0 | H | -10.0 | -16.2 | 27.9 | 74.0 |
2595.343750 | 36.9 | 1000.0 | 1000.000 | 100.0 | H | -68.0 | -15.8 | 37.1 | 74.0 |
3843.781250 | 37.7 | 1000.0 | 1000.000 | 200.0 | H | 56.0 | -13.7 | 36.3 | 74.0 |
7049.875000 | 45.5 | 1000.0 | 1000.000 | 150.0 | H | 66.0 | -5.9 | 28.5 | 74.0 |
10363.281250 | 46.6 | 1000.0 | 1000.000 | 150.0 | H | 27.0 | -2.7 | 27.4 | 74.0 |
Mode 1: Warm lighting, max output (Vertical Polarization)
Frequency (MHz) | Average (dBμV/m) | Meas. Time (ms) | Bandwidth (kHz) | Height (cm) | Pol | Azimuth (deg) | Corr. (dB/m) | Margin - AVG (dB) | Limit AVG (dBμV/m) |
---|---|---|---|---|---|---|---|---|---|
1736.843750 | 32.8 | 1000.0 | 1000.000 | 150.0 | V | -48.0 | -18.8 | 21.2 | 54.0 |
2439.156250 | 33.1 | 1000.0 | 1000.000 | 150.0 | V | -10.0 | -16.2 | 21.0 | 54.0 |
2595.343750 | 27.3 | 1000.0 | 1000.000 | 100.0 | V | -68.0 | -15.8 | 26.7 | 54.0 |
3843.781250 | 25.2 | 1000.0 | 1000.000 | 200.0 | V | 56.0 | -13.7 | 28.8 | 54.0 |
7049.875000 | 32.7 | 1000.0 | 1000.000 | 150.0 | V | 66.0 | -5.9 | 21.3 | 54.0 |
10363.281250 | 35.4 | 1000.0 | 1000.000 | 150.0 | V | 27.0 | -2.7 | 18.6 | 54.0 |
Detailed results for all modes and polarizations are available in the original report.
Test and Measurement Instruments
The following instruments were used for testing:
Equip. no. | Equipment name | Model | Serial no. | Manufacturer | Cal. date | Due date |
---|---|---|---|---|---|---|
EMC-C-195 | EMI test receiver | ESR3 | 102794 | Rohde & Schwarz | 2024-08-03 | 2025-08-03 |
EMC-C-366 | Thermohygrometer | 608-H1 | 2485149174 | testo | 2024-07-26 | 2025-07-26 |
EMC-S-028 | EMI measurement software | EMC32-E+ (10.60.20) | 100150 | Rohde & Schwarz | N/A | N/A |
EMC-C-190 | Artificial mains network | ENV432 | 101514 | Rohde & Schwarz | 2024-10-11 | 2025-10-11 |
EMC-C-066 | EMI test receiver | ESCI | 100280 | Rohde & Schwarz | 2024-10-17 | 2025-10-17 |
EMC-C-001 | 3 m semi-anechoic chamber | SAC3 | FJ129002 | Frankonia | 2023-12-03 | 2026-12-03 |
EMC-S-032 | EMI measurement software | EMC32-MEB (10.60.20) | 100697 | Rohde & Schwarz | N/A | N/A |
EMC-C-373 | Trilog broadband antenna | VULB 9168 | 1771 | Schwarzbeck | 2024-11-23 | 2025-11-23 |
EMC-C-121 | Thermohygrometer | 608-H1 | 1241320265 | testo | 2024-06-25 | 2025-06-25 |
EMC-C-176 | Preamplifier | EMC184045SE | 980596 | EMCI Taiwan | 2024-07-24 | 2025-07-24 |
EMC-C-019 | Double ridged horn antenna | BBHA 9120 D | 9120D-433 | Schwarzbeck | 2025-02-28 | 2026-02-28 |
EMC-C-175 | Preamplifier | EMC051845SE | 980612 | EMCI Taiwan | 2024-07-24 | 2025-07-24 |
EMC-C-161 | Spectrum analyser | FSV40 | 101258 | Rohde & Schwarz | 2024-07-15 | 2025-07-15 |