Owner's Manual

DUCTLESS MULTIZONE HEAT PUMP

22-21 SEER INVERTER

18 000 to 42 000 BTU/hr

Models:

Please read this owner's manual carefully before operating the unit and keep it for future reference.

TABLE OF CONTENTS

  1. Operation notices

    1. Explanation of symbols
    2. Precautions
    3. Working temperature range
    4. Parts name
  2. Maintenance

    1. Cleaning and maintenance
  3. Preparation before installation

    1. Required installation clearance distances diagram
    2. Tools required for installation
    3. Selection of installation location
    4. Requirements for electrical connection
  4. Installation

    1. Installation of outdoor unit
  5. Vacuum pumping
  6. Checking after installation
  7. Other consideration
  8. Pipe expanding method

OPERATION NOTICES

EXPLANATION OF SYMBOLS

PRECAUTIONS

! WARNING

Operation and Maintenance

Wiring

Location

! WARNING

WORKING TEMPERATURE RANGE

Outdoor side DB/WB °C (°F)
Max. cooling 48/- (118/-)
Max. heating 27/- (80/-)

PARTS NAME

NOTICE Actual product may be different from below graphics, please refer to actual product for reference purposes.

Outdoor unit

Air outlet

Valve

MAINTENANCE

CLEANING AND MAINTENANCE

! WARNING

Cleaning the surface of outdoor unit

When the surface of outdoor unit is dirty, use a soft dry cloth or lightly moistened with water to wipe it.

Checking before usage

  1. Check that air inlets and air outlets are not blocked.
  2. Check if circuit breaker and connection are in good condition.
  3. Check that drainage pipe is not damaged or blocked.

Checking after usage

  1. Disconnect power supply.
  2. Check whether mounting bracket for outdoor unit is damaged or corroded. If so, please contact the dealer.

Notice for recovery

  1. Many packing materials are recyclable. Please dispose of them in appropriate recycling bin.
  2. If you want to get rid of the device, please contact a local recycling center for the correct disposal method.

PREPARATION BEFORE INSTALLATION

REQUIRED INSTALLATION CLEARANCE DISTANCES DIAGRAM

NOTICE Actual product may be different from below graphics, please refer to actual product for reference purposes.

Models MPD18, MPD24, MPD30

A: 19 11/16" (500 mm) or more Space to the obstruction

B: 11 13/16" (300 mm) or more Space to the wall

C: 78 3/4" (2000 mm) or more (Air outlet side)

Models MPD36, MPD42

A: 39 3/8" (1000 mm) or more Space to the obstruction

B: 19 11/16" (500 mm) or more Space to the wall

C: 78 3/4" (2000 mm) or more (Air outlet side)

D: 11 13/16" (300 mm) or more (Air inlet side)

E: 19 11/16" (500 mm) or more Space to the obstruction

TOOLS REQUIRED FOR INSTALLATION

NOTICE Contact a qualified person for installation.

SELECTION OF INSTALLATION LOCATION

Basic requirements

Installing the unit in the following places may cause malfunction. If it is unavoidable, please consult a qualified person:

Outdoor unit

REQUIREMENTS FOR ELECTRICAL CONNECTION

Safety precautions

Grounding requirements

INSTALLATION

! CAUTION Installation must be performed in accordance with the NEC/CEC by authorized personnel only.

INSTALLATION OF OUTDOOR UNIT

Step 1: Fix the support of outdoor unit (select it according to the actual installation situation)

Notes:

Step 2: Install drain joint

Diagram: A diagram shows the drain joint connection with the chassis and drain hose.

Step 3: Fix outdoor unit

Diagram: A diagram shows the outdoor unit being placed on the support and secured with bolts through the foot holes.

Step 4: Connect indoor and outdoor pipes

Hex nut diameter Tightening torque (N-m)
Φ6 15~20
Φ 9.52 30~40
Φ 12 45~55
Φ 16 60~65
Φ 19 70~75

NOTES:

Step 5: Wiring of the unit

Diagrams: Wiring diagrams for MPD18, MPD24, MPD30, MPD36, and MPD42 models showing connections to units A, B, C, D, E and the power supply.

Notes: These wiring diagrams are for reference only, please always refer to the one on the actual unit. Actual product may be different from above graphics, please refer to actual product for reference purposes.

Step 6: Pipe arrangement

Diagram: A diagram illustrates the pipe arrangement with a U-shaped curve for rain prevention.

Maximum length of connection pipe and maximum height difference

Diagram: A diagram shows the layout of indoor and outdoor units with labels for pipe lengths (L1-L5) and height differences (H1, H2).

Model # Max. total length of connection pipe L1+L2+L3+L4+L5 Max. length for single unit Lx Max. height difference outdoor to indoor unit H1 Max. height difference between indoor units H2
ft. (m) ft. (m) ft. (m) ft. (m)
MPD18KCH22S-O 66 (20) 33 (10) 33 (10) 33 (10)
MPD24KCH21S-O 197 (60) 66 (20) 33 (10) 33 (10)
MPD30KCH21S-O 230 (70) 82.5 (25) 49.5 (15) 25 (7.5)
MPD36KCH21S-O 246 (75) 82.5 (25) 49.5 (15) 25 (7.5)
MPD42KCH21S-O 246 (75) 82.5 (25) 49.5 (15) 25 (7.5)

The outdoor unit is shipped with a full charge of R-410A refrigerant for the following total piping lengths:

Model # Pre-charge length ft. (m)
MPD18KCH22S-O 33 (10)
MPD24KCH21S-O 98 (30)
MPD30KCH21S-O 130 (40)
MPD36KCH21S-O 130 (40)
MPD42KCH21S-O 130 (40)

For pipe runs over this limit, add 0.2 oz/ft (20 g/m) of additional refrigerant.

VACUUM PUMPING

Humid air left inside the refrigerant circuit can cause compressor malfunction. After having connected the indoor and outdoor units, bleed the air and humidity from the refrigerant circuit using a vacuum pump.

  1. Unscrew and remove the caps from the 2-way and 3-way valves.
  2. Unscrew and remove the cap from the service valve.
  3. Connect the vacuum pump hose to the service valve.
  4. Operate the vacuum pump for 10-15 minutes until an absolute vacuum of 3/8" (10 mm) Hg has been reached.
  5. With the vacuum pump still in operation, close the low-pressure knob on the vacuum pump coupling. Stop the vacuum pump.
  6. Open the 2-way valve by 1/4 turn and then close it after 10 seconds. Check all the joints for leaks using liquid soap or an electronic leak device.
  7. Turn the body of the 2-way and 3-way valves. Disconnect the vacuum pump hose.
  8. Replace and tighten all the caps on the valves.

Diagrams: Diagrams illustrate the vacuum pumping process and valve operations.

CHECKING AFTER INSTALLATION

Check the following items after finishing installation:

Items to check Possible malfunction
Has the unit been installed solidly? The unit may drop, shake or emit noise.
Have you done the refrigerant leakage test? It may cause insufficient cooling (heating) capacity.
Is heat insulation of pipeline sufficient? It may cause condensation and water dripping.
Is water drained well? It may cause condensation and water dripping.
Is the voltage of power supply according to the voltage marked on the nameplate? It may cause malfunction or damaging the parts.
Are electric wiring and pipes installed correctly? It may cause malfunction or damaging the parts.
Is the unit grounded securely? It may cause electric leakage.
Does the power wire follow the specifications? It may cause malfunction or damaging the parts.
Is there any obstruction in the air inlet and outlet? It may cause insufficient cooling (heating) capacity.
Are dust and installation debris removed? It may cause malfunction or damaging the parts.
Are gas valve and liquid valve of connection pipe completely opened? It may cause insufficient cooling (heating) capacity.
Have the length of refrigerating pipe and refrigerant charge amount been recorded? It is not easy to figure out the charge amount of refrigerant if it has not been recorded.

OTHER CONSIDERATIONS

PIPE EXPANDING METHOD

Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps:

1. Cut the pipe

Diagram: A diagram shows the correct way to cut a pipe with a pipe cutter, indicating 90° angle and avoiding leaning, uneven cuts, and burrs.

2. Remove the burrs

Diagram: A diagram shows using a shaper to remove burrs downwards from a pipe.

3. Put on suitable insulating pipe

4. Put on the union nut

5. Expand the port

Diagram: A diagram shows using an expander with a hard mold to expand the pipe port.

Note: "A" varies according to the diameter, please refer to the chart below:

Outer diameter (mm) A (mm)
Max Min
Φ 6 - 6.35 (1/4") 1.3 0.7
Φ 9.52 (3/8") 1.6 1.0
Φ 12 - 12.7 (1/2″) 1.8 1.0
Φ 15.8 - 16 (5/8″) 2.4 2.2

6. Inspection

Diagram: Diagrams show examples of proper expansion (smooth surface, equal length) and improper expansion (leaning, damaged, crack, uneven thickness).

Models: MPD18KCH22S-O, MPD24KCH21S-O, MPD30KCH21S-O, MPD36KCH21S-O, MPD42KCH21S-O, Ductless Multizone Heat Pump

File Info : application/pdf, 18 Pages, 1.97MB

PDF preview unavailable. Download the PDF instead.

X62407A MPD EN Acrobat Distiller 11.0 (Windows)

Related Documents

Preview Dettson EVO High Efficiency Central Heat Pump System
Dettson EVO is a high-efficiency central heat pump system offering advanced inverter technology, eco-friendly operation, and flexible installation options for residential and commercial use. Features include R410A refrigerant, ENERGY STAR certification, and detailed performance specifications.
Preview Dettson R02P034 Communicating Thermostat: Installation and Homeowner's Manual
This manual provides installation instructions and homeowner information for the Dettson R02P034 communicating thermostat. It covers product overview, safety warnings, wiring, installation steps, operation modes, display controls, settings, and equipment menus.
Preview Dettson R02P032 Communicating Thermostat: Installation and Homeowner's Manual
Comprehensive installation instructions and homeowner's manual for the Dettson R02P032 Communicating Thermostat. Learn about its flexible programming, energy-saving features, maintenance reminders, and advanced diagnostic capabilities for ClimateTalk™ systems.
Preview Dettson Smart Zoning System Installation and Homeowner's Manual
Installation and homeowner's manual for the Dettson Smart Zoning System, covering models B40775, B40776, and B40777. Includes safety information, installation steps, configuration, system behavior, troubleshooting, and repair parts.
Preview Dettson Chinook Gas Furnace Installation and Homeowner's Manual
Comprehensive installation instructions and homeowner's guide for Dettson Chinook 2-Stage ECM gas furnaces (Models C15-2-V through C120-2-V), covering safety, installation, operation, and maintenance.
Preview Dettson Supreme ECM Motor: Variable Speed Electric Furnace
Explore the Dettson Supreme ECM Motor, a variable speed electric furnace offering advanced features for efficient heating. Learn about its Advantage and Modulating series, specifications, and installation benefits.
Preview Hydra Industrial Electric Boiler Installation and Homeowner's Manual
Comprehensive installation and operation manual for Dettson Hydra Industrial electric boilers, covering models HYDRAI016 through HYDRAI096. Includes safety instructions, installation procedures, operation guidelines, maintenance, and technical specifications.