ComfortStar High Wall Heat Pump System
Submittal Data Sheet
Model Number: CPP3-30CD(I) / CPP3-30CD(O)(23F)
Specifications
Category | Cooling | Heating |
---|---|---|
SEER2 | 22.3 | HSPF2-4 |
EER2 | 12.0 | COP |
Rated Capacity | 30000 Btu/hr | 30000 Btu/hr |
Min/Max Capacity | 6800~33900 Btu/hr | 12300~32100 Btu/hr |
Moisture Removal(L/h) | 3.6 | 20000 Btu/hr |
Standard Operating Range (°F/°C) | -13~122 (-25~50) | -13~75 (-25~24) |
Indoor Unit Specifications
- Indoor Air Flow (Turbo/H/M/L/SI): 871.1/647.5/447.3/329.6/175 CFM
- Indoor Noise Level (Turbo/H/M/L/SI): 56.5/52/45/36/22 dBA
- Dimensions (W×D×H): 49.57 x 11.14 x 14.25 inches (1259.0 x 283.0 x 362.0 mm)
- Package Dimensions (W×D×H): 52.76 x 17.72 x 15.16 inches (1340 x 450 x 385 mm)
- Net/Gross Weight: 43.43/56.88 lbs (19.7/25.8 kg)
Outdoor Unit Specifications
- Compressor Type: ROTARY
- Compressor Model: KTF250D22UMT
- Refrigerant: R454B
- Refrigerant Oil Charge: 670 mL
- Refrigerant Oil: VG74
- Outdoor Air Flow (Max): 2235.3 CFM
- Outdoor Noise Level: 61.5 dBA
- Dimensions (W×D×H): 37.24 x 16.14 x 31.89 inches (946.0 x 410.0 x 810.0 mm)
- Package Dimensions (W×D×H): 42.91 x 19.68 x 34.84 inches (1090 x 500 x 885 mm)
- Net/Gross Weight: 142.86/154.54 lbs (64.8/70.1 kg)
Electrical Specifications
- Power Supply: 208/230V, 60Hz, 1Ph
- System MCA: 28.0 A
- Connection Wiring: 14#x4
- System MOCP: 30 A
- Compressor RLA: 17.5 A
- Outdoor Fan Motor RLA: 1.3 A
- Outdoor Fan Motor W: 120 W
- Indoor Fan Motor RLA: 0.7 A
- Indoor Fan Motor W: 58 W
- System Power Input @ Cooling: 2500 W (700~3220 W)
- System Power Input @ Heating: 2900 W (755~2950 W)
- MCA: Min. circuit amps (A)
- RLA: Rated load amps (A)
- MOCP: Max. over current protection (A)
- W: Fan motor rated output (W)
Piping Specifications
- Throttle type (Indoor): N/A
- Throttle type (Outdoor): EXV+Capillary
- Liquid Size: 9.52mm (3/8in)
- Gas Size: 15.9mm (5/8in)
- Max. Piping Length: 164.00 ft (50 m)
- Max. Height Difference: 82.00 ft (25 m)
- Max. Pre-charged Length: 24.6 ft (7.5 m)
- Refrigerant Pre-charged Amount: 84.66 oz (2.4 kg)
- Additional Charge of Refrigerant: 0.32 oz/ft (30 g/m)
- Connection Method: Flared
Features
- Indoor unit TU1 copper coil
- Humidity control
- 1~100% fan speed setting
- WiFi capability: through WiFi dongle or wired controller with built-in WiFi
- OTA (by using WiFi dongle)
Multiple control options available:
- Two way communication wired controller: AWC-8P-CPP*
- Two way communication wired controller with built-in WiFi: AWC-8P-LC-WIFI
- Infrared wired controller: AWC-4
- Wireless remote controller
- Third-Party 24V Thermostat
Indoor Unit Dimensions
Capacity | Body Code | W (inch/mm) | D (mm/inch) | H (mm/inch) |
---|---|---|---|---|
6K-9K | A | 28-3/4in/729mm | 7-7/8in/200mm | 11-1/2in/292mm |
9K-12K | B | 31-5/8in/802mm | 7-7/8in/200mm | 11-5/8in/295mm |
18K | C | 38-1/4in/971mm | 9in/228mm | 12-5/8in/321mm |
18K-24K | D | 42-5/8in/1082mm | 9-1/4in/234mm | 13-1/4in/337mm |
30K-36K | F | 49-5/8in/1259mm | 11-1/8in/283mm | 14-1/4in/362mm |
Installation Instructions - Indoor Unit
Select Installation Location. The diagram shows a wall with a 6" (15cm) horizontal measurement and 4-3/4" (12cm) vertical measurements. The piping exit can be on the left-hand side, right-hand side, left rear, or right rear.
NOTE: Based on the position of the wall hole relative to the mounting plate, choose the side from which the piping will exit the unit. You have four options for the piping exit.
NOTE: When the gas side connective pipe is (5/8in)16mm or more, the wall hole should be (3-1/2in)90mm.
Indoor unit dimensions (WxH): 49.57in(1259mm)×14.25in(362mm)
Outdoor Unit Dimensions
Diagrams showing the front, side, and top views of the outdoor unit with dimensions labeled.
Installation Instructions - Outdoor Unit
Clearance requirements for the outdoor unit:
- 20in (500mm) or more when front and sides of the unit are clear.
- 4in (100mm) or more on the sides.
- 14in (350mm) or more on the rear.
- 20in (500mm) or more when any 2 sides (left, right, and rear) of the unit are clear.
✔️ Meets all spatial requirements shown in Installation Clearance Requirements above.