Portable Air Conditioner Owner's Manual

Item No: A4211-8K

Applicable Model: OL-BA011D1-05CD/D2

(With R32 refrigerant)

READ AND SAVE THESE INSTRUCTIONS

1. BEFORE YOU BEGIN

1.1 PRODUCT DESCRIPTION

Powerful portable air conditioners are great cooling solutions for single rooms, creating a comfortable atmosphere. They also have ventilation and dehumidifying functions for circulating air and removal of moisture. These self-contained systems do not require permanent installation, allowing them to be moved to the space where they are most needed. They are commonly used in kitchens, temporary residences, computer rooms, garages, and many other places where installation of an Air-conditioner Outdoor Unit is limited.

The environmentally friendly R32 is used as the refrigerant. R32 has no damaging influence on the ozone layer (ODP), a negligible greenhouse effect (GWP), and is available worldwide. Because of its efficient energy properties, R32 is highly suitable as a coolant for this application. Special precautions must be taken into consideration due to the coolant's high flammability.

1.2 SYMBOLS FROM THE UNIT AND USER MANUAL

⚠ WARNING This unit uses a flammable refrigerant. If refrigerant leaks and comes in contact with a fire or heating part, it will create harmful gas and there is a risk of fire.

? Read the USER MANUAL carefully before operation.

Further information is available in the USER MANUAL, SERVICE MANUAL, and the like.

? Service personnel is required to carefully read the USER MANUAL and SERVICE MANUAL before operation.

2. FOR YOUR SAFETY

Your safety is the most important thing we are concerned about!

⚠ WARNING Please read this manual carefully and fully understand before operating your appliance.

2.1 OPERATIONAL PRECAUTIONS

WARNING- to reduce the risk of fire, electric shock or injury to persons or property:

⚠ WARNING Any person who is involved with working on or breaking into a refrigerant circuit should hold a currently valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry-recognized assessment specification.

⚠ WARNING Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.

If you don't understand something or need help, please contact the dealer services.

2.2 SAFETY PRECAUTIONS ON SERVICING

Please follow these warnings when undertaking servicing of an appliance with R32.

2.2.1 Checks to the area

Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

2.2.2 Work procedure

Work shall be undertaken under a controlled procedure so as to minimize the risk of flammable gas or vapor being present while the work is being performed.

2.2.3 General work area

All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the work space shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

2.2.4 Checking for presence of refrigerant

The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e., no sparking, adequately sealed, or intrinsically safe.

2.2.5 Presence of fire extinguisher

If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

2.2.6 No ignition sources

No person carrying out work in relation to a refrigeration system that involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removal, and disposal, during which flammable refrigerant can possibly be released into the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking" signs shall be displayed.

2.2.7 Ventilated area

Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

2.2.8 Checks to the refrigeration equipment

Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times, the manufacturer's maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer's technical department for assistance.

The following checks shall be applied to installations using flammable refrigerants:

2.2.9 Checks to electrical devices

Repair and maintenance of electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.

Initial safety checks shall include:

⚠ WARNING! Install the unit in rooms that exceed 4 m².

Do not install the unit in a place where inflammable gas may leak.

❗ NOTE! The manufacturer may provide other suitable examples or may provide additional information about the refrigerant odor.

3. PRODUCT OVERVIEW

3.1 PRODUCT DIAGRAM

A diagram shows the portable air conditioner with numbered parts:

Note: The appearance is only for reference. Please check the real product for detailed information.

3.2 FEATURES

4. INSTALLATION

4.1 UNPACKING

Accessories:

4.2 Choose your location

⚠ WARNING! Install the unit in rooms that exceed 4 m².

Do not install the unit in a place where inflammable gas may leak.

❗ NOTE! The manufacturer may provide other suitable examples or may provide additional information about the refrigerant odor.

4.3 ATTACH THE EXHAUST HOSE

The air conditioner requires venting outside so that the exhaust air can escape the room, as it contains waste heat and moisture. Do not replace or extend the exhaust hose, which will result in decreased efficiency or even shut down the unit due to low back pressure.

Step 1: Connect the hose connector to one end of the exhaust hose.

Step 2: Connect the windows kit adapter to the other end of the exhaust hose.

Step 3: Extend the adjustable window kit to the length of your window. Connect the exhaust hose to the window kit.

Step 4: Close your window to secure the kit in place. It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency.

Step 5: Attach the hose connector to the exhaust air outlet of the unit.

Step 6: Adjust the length of the flexible exhaust hose to ensure the distance between the unit and the window is more than 70cm, and the height from the exhaust hose to the floor is more than 90cm. Avoid bends in the hose. Then place the AC near an electrical outlet.

Step 7: Adjust the louver at the air outlet, and then switch on the unit.

5. OPERATION

5.1 CONTROL PANEL AND DISPLAY

A diagram illustrates the control panel with the following numbered functions:

5.2 REMOTE CONTROL

A diagram shows the remote control with buttons for High, Up, COOL, Low, Down, Dry, Fan, Sleep, Timer, °C/°F, and Power.

5.3 SETTINGS

5.3.1 Start-up and Shutdown

5.3.2 Operation mode

The unit has four operation modes: Cool, Dry, Fan, Sleep. The unit's working temperature under cooling mode is 61°F-95°F.

A. Cooling your room:

B. Ventilating your room:

C. Drying your room:

D. Sleep mode (this function can only be used with a remote control):

5.3.3 TIMER SETTING (1hour-24hours)

The timer has two ways of operation:

5.3.4 Automatic Defrost

At low room temperatures, frost may build up at the evaporator during operation. The unit will automatically start defrosting, and the POWER LED will blink. The defrost control sequence is as follows:

5.3.5 Overload Protection

In the event of a power loss, to protect the compressor, there is a 3-minute delay until the compressor restarts.

5.4 DRAINAGE

Manual drainage:

  1. When the machine stops because the water is full, unplug the power plug. Please move the machine carefully to avoid spilling the water in the water pan at the bottom of the body.
  2. Place a water container below the side water outlet behind the body.
  3. Unplug the water plug; the water will automatically flow into the water container. Notes: Keep the water plug properly. During drainage, the body can be tilted slightly backward. If the water container cannot hold all the water, plug the water outlet as soon as possible before the container is full to prevent water from flowing to the floor or carpet.
  4. When the water is discharged, plug the water plug. Notes: Restart the machine after the water plug and drainage cover are installed; otherwise, condensate water will flow to the floor or carpet.

Continuous drainage:

The self-evaporating system uses the collected water to cool the condenser coils for better efficient performance. It is not necessary to empty the drainage tank in cooling operation, except in drying operation and high humidity conditions. The condensate water evaporates at the condenser and is evacuated through the exhaust hose.

For continuous operation or unattended operation in drying operation, connect the attached drain hose to the unit. Condensate water can flow automatically into a bucket or drain by gravity.

To avoid water spillage:

6. CLEANING AND CARE

6.1. CLEANING THE AIR FILTER (every two weeks)

Dust collects on the filter and restricts airflow. Restricted airflow reduces the efficiency of the system, and if it becomes blocked, it can cause damage to the unit.

The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated.

  1. Press POWER button to switch off the unit and unplug the power cord.
  2. Remove the filter mesh from the unit.
  3. Use a vacuum cleaner to suck dust from the filter.
  4. Turn the filter over and rinse the air filter under running water. Let the water run through the filter in the opposite direction of airflow. Set aside and allow the filter to air dry completely before reinstalling.

Switch off the unit and remove the air filters. Rinse the air filter under running water.

Warning!!! Do not touch the evaporator surface with bare hands, as it could cause injury to your fingers.

6.2. CLEANING UP OF REFRIGERANT

General Measures:

  1. Gas/vapor is heavier than air, which may accumulate in confined spaces, particularly at or below ground level.
  2. Eliminate every possible source of ignition.
  3. Use appropriate personal protection equipment (PPE).
  4. Evacuate unnecessary personnel, isolate, and ventilate the area.
  5. Do not let it into the eyes, on the skin, or clothing. Do not inhale vapors or gas.
  6. Prevent it from entering sewers and public water areas.
  7. Block the source of the release, if safe to do so. Consider the use of water spray to disperse vapors.
  8. Isolate the area until the gas has dispersed. Ventilate and gas test the area before entering. Contact competent authorities after a spill.

7. TROUBLESHOOTING

Symptom Inspection Solution
The unit is not operating. ✓ Check the power connection securely. Insert the power cord securely into the wall outlet.
✓ Check if the water level indicator lights up? Empty the drain pan by removing the rubber plug. The range of operating temperature is 41-95°F.
✓ Check the room temperature. Clean the air filter as necessary.
✓ Check the air filter for dirt. To clear the obstacle.
The unit works with reduced capacity. ✓ Check if the air duct is blocked. Keep the door and windows closed.
✓ Check if the room door or window is open. Set the mode and temperature at the proper set-point according to the manual.
✓ Check if the desired operating mode is selected and the temperature is properly set. Make sure the exhaust hose is securely attached.
Water Leakage ✓ The exhaust hose is detached. Empty the water tank before transport.
✓ Overflow while moving the unit. Straighten the hose to avoid a trap existing.
✓ Check if the drain hose is kinked or bends. Place the unit on a horizontal and firm ground.
Excessive Noise ✓ Check if the unit is securely positioned. Secure and tighten the parts.
✓ Check if any loose, vibrating parts. Noise comes from flowing refrigerant. This is normal.
Error Codes The noise sounds like water flowing. Check the wire harness of the display PCB for damage.
E0: Communication faults between the main PCB and display PCB. Check the connection or replace it. To clean or replace the temperature sensor.
E1: Ambient temperature sensor failure. Check the connection or replace it. To clean or replace the temperature sensor.
E2: Coil temperature sensor failures. Empty the drain pan by removing the rubber plug.
Ft: Condensate water high level alarm.

8. DECOMMISSIONING

8.1. STORAGE

Long-Term Storage: If you will not be using the unit for an extended period (more than a few weeks), it is best to clean the unit and dry it out completely. Please store the unit per the following steps:

  1. Unplug the unit and remove the exhaust hose and window kit stored with the unit.
  2. Drain the remaining water from the unit.
  3. Clean the filter and let the filter dry completely in a shaded area.
  4. Re-install the filter at its position.
  5. The unit must be kept in an upright position when in storage.
  6. Preserve the machine in a ventilating, dry, non-corrosive gas, and safe indoor place.

ATTENTION: The evaporator inside the machine must be dried out before the unit is packed to avoid component damage and molds. Unplug the unit and place it in a dry open area for days to dry it out. Another way to dry the unit is to turn on the machine, adjust it to low-wind ventilation mode, and maintain this state until the drainage pipe becomes dry, so as to keep the inside of the body dry and prevent mildewing.

8.2. DISPOSAL

⚠ WARNING!!! Releasing refrigerant into the atmosphere is strictly forbidden!

Do not dispose of electrical appliances as unsorted municipal waste. Use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.

Models: A4211-8K, OL-BA011D1-05CD-D2, A4211-8K Portable Air Conditioner, Portable Air Conditioner, Air Conditioner, Conditioner

File Info : application/pdf, 31 Pages, 763.03KB

PDF preview unavailable. Download the PDF instead.

A4211-8K ?v=1688547316 WPS 文字

Related Documents

Preview Portable Air Conditioner Owner's Manual - Model OL-A011D2-05CD
This owner's manual provides essential information for the Portable Air Conditioner, model OL-A011D2-05CD. Learn about product features, installation, operation, maintenance, and troubleshooting for efficient cooling, ventilation, and dehumidification.
Preview OL-BKY26-A010M Portable Air Conditioner Owner's Manual
Comprehensive owner's manual for the OL-BKY26-A010M portable air conditioner, covering installation, operation, safety precautions, cleaning, troubleshooting, and decommissioning. Features R290 refrigerant.
Preview Portable Air Conditioner Owner's Manual
Owner's manual for a portable air conditioner, detailing product description, safety precautions, installation, operation, cleaning, troubleshooting, and decommissioning.
Preview A010L Series Portable Air Conditioner Owner's Manual
Comprehensive owner's manual for the A010L Series Portable Air Conditioner, covering installation, operation, maintenance, troubleshooting, and safety precautions for efficient cooling and dehumidification.
Preview Owner's Manual and Operating Guide for LP1419IVSM Appliance
Comprehensive owner's manual for the LP1419IVSM appliance, providing essential operating instructions, information on remote control variations, accessory compatibility, and product support resources.
Preview Portable Air Conditioner User Manual: Models A5406-8K-CH, A5406-10K-CH, A5406-8K-JP, A5406-10K-JP
Comprehensive user manual for the portable air conditioner, covering safety instructions, installation, operation, maintenance, and troubleshooting for models A5406-8K-CH, A5406-10K-CH, A5406-8K-JP, and A5406-10K-JP.
Preview Portable Air Conditioner PAC006-12K Quick Start Guide
A quick start guide for the Portable Air Conditioner PAC006-12K, covering window panel preparation, installation, control panel functions, and maintenance.
Preview Portable Air Conditioner User Manual
User manual for a portable air conditioner, providing operating instructions, safety precautions, and maintenance guidelines.