GREE FLEXX ULTRA R32 Heat Pump Submittal Data & Specifications
Brand: GREE
Product Type: Unitary Heat Pump Split System
This document provides comprehensive submittal data, technical specifications, dimensions, and installation clearance guidelines for the GREE FLEXX ULTRA R32 36000 BTU/H A-Coil Unitary Heat Pump Split System, including the indoor unit (FXA36C32AH) and outdoor unit (FXU36HP230V1R32AO).
Submittal Data
Job Name: [Placeholder]
Location: [Placeholder]
Date: [Placeholder]
Purchaser: [Placeholder]
Engineer: [Placeholder]
Submitted to: [Placeholder]
For: [Placeholder]
Unit Designation: [Placeholder]
Schedule No.: [Placeholder]
General Features
- AHRI Certificate: 211306455
- High Efficiency DC Inverter Technology
- Compact and Quiet 55 dB(A) Side Discharge Outdoor Unit
- 24VAC Thermostat Compatible
- Optional 7-Day Programmable 24V Controller WK-010WC1
- Designed for New Construction or Replacement Market
- Low Ambient Cooling down to 5°F (-15°C)
- Low Ambient Heating down to -22°F (-30°C)
- Coil (Outdoor): Copper Tube/Aluminum Fin with Anti-Corrosion Coil Coating (Gold Colored Fin - 1500Hr Salt Spray Rating)
- Coil (Indoor): Copper Tube/Aluminum Fin with Anti-Corrosion Coil Coating (Blue Colored Fin - 500Hr Salt Spray Rating)
Specifications, Features & Function Summary
Outdoor Model | HEAT PUMP FXU36HP230V1R32AO |
Indoor Model | FXA36C32AH |
System Performance
Parameter | Unit | Cooling | Heating |
---|---|---|---|
Min - Max | Btu/h | 18,000 - 35,000 | 18,000 - 38,000 |
Rated Capacity @95°F | Btu/h | 32,000 | |
Rated Capacity @47°F | Btu/h | 35,000 | |
Rated Capacity @17°F | Btu/h | 22,000 | |
Rated Capacity @5°F | Btu/h | 25,600 | |
SEER2 | 16.0 | ||
EER2 | 11.0 | ||
HSPF2 | 8.5 | ||
COP @5°F | 1.80 | ||
Cooling Temperature Range | °F | 5 - 129 | |
Heating Temperature Range | °F | -22 - 75 | |
Refrigerant Type | R32 |
Indoor Unit (FXA36C32AH)
Dehumidification | pt/hr | 7.75 |
Drain Piping | in | Φ1×0.05 |
External Dimensions (W x H x D) | in | 17-1/2 x 23 x 21-1/4 |
Package Dimension (W x H x D) | in | 21 x 25-3/4 x 27-1/8 |
Net Weight | lbs | 75 |
Gross Weight | lbs | 83.8 |
Outdoor Unit (FXU36HP230V1R32AO)
Power Supply | VAC | 208-230V/1Ph/60 Hz |
Sound Pressure Level | dB(A) | 61 |
Control Voltage | VAC | 24 |
Rated Current Cooling | A | 12.6 |
Rated Current Heating | A | 13.91 |
MOCP | A | 30 |
MCA | A | 27.7 |
Compressor Type | GREE G20 / DOUBLE CYLINDER / 2-STAGE INVERTER | |
External Dimensions (W x H x D) | in | 39 x 37-13/16 x 14-9/16 |
Package Dimension (W x H x D) | in | 45-3/8 x 43-11/16 x 18-13/16 |
Net Weight | lbs | 187.4 |
Gross Weight | lbs | 211.6 |
Refrigerant Charge - R32 | oz | 102.3 |
Additional Charge | oz/ft | 0.323 |
Refrigerant Piping
Line Set Size (Liquid - Gas) - Flared Connections | in | 3/8 - 3/4 |
Pre-Charge Length | ft | 31 |
Pipe Length (Min - Max) | ft | 10 - 164 |
Max. Pipe Elevation | ft | 98 |
Features & Functions Summary
Feature | Value |
---|---|
Compressor | Inverter |
Ultra Low Frequency Torque Control | Yes |
Power Factor Correction | Yes |
Compressor Type | Rotary |
Refrigerant Type | R32 |
Electronic Expansion Valve (EEV) | Yes |
Basepan With Electric Heater | Yes |
Compressor With Electric Heater | Yes |
Fin Coating (Outdoor - Golden & Indoor - Blue) | Acrylic Resin |
Intelligent Defrosting | Yes |
Intelligent Preheating | Yes |
Low Voltage Startup | Yes |
Memory/Power Failure Recovery | Yes |
Self Diagnosis | Yes |
Low Ambient Cooling | Yes |
24VAC Thermostat Compatible | Yes |
A2L Leak Detection Sensor (Indoor) | Factory Installed |
Dimensions
Indoor Unit (FXA36C32AH)
Unit: inch
Dimension | Value |
---|---|
W (Width) | 17-1/2 |
D (Depth) | 21-1/4 |
H (Height) | 23 |
A | 15-7/8 |
B | 19-3/8 |
E | 7-1/6 |
F | 9 |
Outdoor Unit (FXU36HP230V1R32AO)
Unit: inch
Dimension | Value |
---|---|
A | 39 |
B | 16-13/16 |
C | 37-13/16 |
D | 29-3/4 |
E | 15-9/16 |
F | 14-9/16 |
Clearances
Indoor Unit Minimum Clearance
A minimum of 25 inches (approx. 63.5 cm) is required in front of the unit for service clearance.
The drain pan must be at least 2 inches (approx. 5 cm) away from a standard gas-fired furnace heat exchanger and at least 4-6 inches (approx. 10-15 cm) away from any drum-type or oil-fired furnace heat exchanger.
Outdoor Unit Minimum Clearance
Note: Install the Outdoor Unit 2 inches (approx. 5 cm) above the expected snow line.
1. When one outdoor unit is to be installed:
Clearance requirements (in inches) for a single outdoor unit installation, specifying minimum distances (a, b, c, d, e) based on relationships between unit height (H) and other dimensions (Hb, Hd):
- A, B, C, E: Minimum clearances are typically ≥12 inches for 'a', 'b', and 'c', and ≥40 inches for 'd' and 'e'. Specific conditions apply based on height ratios (e.g., H ≤ 1/2H, 1/2H < H ≤ H, H > H).
- D: Minimum clearance of ≥80 inches for 'd' and 'e'.
- B, D: Minimum clearance of ≥10 inches for 'a', ≥80 inches for 'd', and ≥40 inches for 'e', with conditions on height ratios.
- B, D, E: Minimum clearance of ≥10 inches for 'a', ≥80 inches for 'd', and ≥40 inches for 'e', with conditions on height ratios.
2. When two or more outdoor units are to be installed side by side:
Clearance requirements (in inches) for multiple outdoor units installed side-by-side, specifying minimum distances (a, b, c, d, e) based on unit relationships and height ratios:
- A-E, A,B,C, A,B,C,E: Minimum clearances vary, generally ≥12 inches for 'a', 'b', 'c', and ≥40 inches for 'd', 'e', with specific height ratio conditions.
- D, D,E: Minimum clearance of ≥80 inches for 'd' and 'e'.
- B,D, B,D,E: Minimum clearances include ≥10 inches for 'a', ≥80 inches for 'd', and ≥40 inches for 'e', with height ratio conditions.
3. When outdoor units are installed in rows:
Clearance requirements (in inches) for outdoor units installed in rows, specifying minimum distances (b, d) based on unit height (H) and other dimensions (Hb, Hd):
- H ≤ 1/2H: Minimum 'b' is 10 inches, 'd' is ≥80 inches.
- 1/2H < H ≤ H: Minimum 'b' is 12 inches, 'd' is ≥160 inches.
- H > H: Prohibited.
4. When outdoor units are installed one above another:
Clearance requirements (in inches) for outdoor units installed vertically, specifying minimum distances (a, b, H) based on unit height (H) and other dimensions (Hb):
- Minimum 'a' is 20 inches, 'b' is ≥3 inches, and the lower unit's height (H) requires a minimum clearance of ≥80 inches above it.