GREE FLEXX ULTRA R32
SUBMITTAL DATA
FXA48C32AH / FXU60HP230V1R32A0
48000 BTU/H A-Coil for Unitary Heat Pump Split System
Job Name: [Input Field]
Purchaser: [Input Field]
Submitted to: [Input Field]
Unit Designation: [Input Field]
Location: [Input Field]
Engineer: [Input Field]
For: [Input Field]
Schedule No.: [Input Field]
Date: [Input Field]
Image of the GREE FXA48C32AH indoor unit.
Image of the GREE FXU60HP230V1R32AO outdoor unit.
Image of the GREE WK-010WC1 optional thermostat, displaying '60 25 22'.
GENERAL FEATURES
- AHRI Certificate: 217177257
- High Efficiency DC Inverter Technology
- Compact and Quiet 55 dB(A) Side Discharge Outdoor Unit
- 24VAC Thermostat Compatible
- Optional 7-Day Programmable 24V Controller WK-010WC1
- Designed for New Construction or Replacement Market
- Low Ambient Cooling down to 5°F (-15°C)
- Low Ambient Heating down to -22°F (-30°C)
- Coil (Outdoor) Copper Tube/Aluminum Fin with Anti-Corrosion Coil Coating (Gold Colored Fin - 1500Hr Salt Spray Rating)
- Coil (Indoor) Copper Tube/Aluminum Fin with Anti-Corrosion Coil Coating (Blue Colored Fin - 500Hr Salt Spray Rating)
SPECIFICATIONS, FEATURES & FUNCTION SUMMARY
SYSTEM TYPE
Outdoor Model | HEAT PUMP |
Indoor Model | FXU60HP230V1R32AO |
FXA48C32AH |
SYSTEM PERFORMANCE
Btu/h | ||||
---|---|---|---|---|
Cooling | Min - Max | 34,000 - 50,000 | Compressor | Inverter |
Rated Capacity @95°F | 48,000 | Ultra Low Frequency Torque Control | Yes | |
Heating | Min - Max | 34,000 - 52,000 | Power Factor Correction | Yes |
Rated Capacity @47°F | 48,000 | Compressor Type | Rotary | |
Rated Capacity @17°F | 31,200 | Refrigerant Type | R32 | |
Rated Capacity @5°F | 36,000 | Electronic Expansion Valve (EEV) | Yes | |
SEER2 | 15.2 | Basepan With Electric Heater | Yes | |
EER2 | 10.0 | Compressor With Electric Heater | Yes | |
HSPF2 | 8.5 | Fin Coating (Outdoor - Golden & Indoor - Blue) | Acrylic Resin | |
COP @5°F | 1.80 | Intelligent Defrosting | Yes | |
Cooling Temperature Range | 5 - 129 °F | Intelligent Preheating | Yes | |
Heating Temperature Range | -22 - 75 °F | Low Voltage Startup | Yes | |
Refrigerant Type | R32 | Memory/Power Failure Recovery | Yes | |
Self Diagnosis | Yes | |||
Low Ambient Cooling | Yes | |||
24VAC Thermostat Compatible | Yes | |||
A2L Leak Detection Sensor (Indoor) | Factory Installed |
INDOOR UNIT
Dehumidification | 11.77 pt/hr |
Drain Piping | Φ1 x 0.05 in |
External Dimensions (W x H x D) | 24-1/2 x 28-1/2 x 21-1/4 in |
Package Dimension (W x H x D) | 28-1/8 x 31-5/16 x 27-1/8 in |
Net Weight | 110.0 lbs |
Gross Weight | 123.5 lbs |
OUTDOOR UNIT
Power Supply | 208-230V / 1Ph / 60 Hz |
Sound Pressure Level | 63 dB(A) |
Control Voltage | 24 VAC |
Rated Current Cooling | 18.6 A |
Rated Current Heating | 19.1 A |
MOCP | 45 A |
MCA | 39.9 A |
Compressor Type | GREE G20 / DOUBLE CYLINDER / 2-STAGE INVERTER |
External Dimensions (W x H x D) | 35-7/16 x 49-5/8 x 13-3/8 in |
Package Dimension (W x H x D) | 40-11/16 x 55-3/16 x 17-3/8 in |
Net Weight | 241.4 lbs |
Gross Weight | 263.5 lbs |
Refrigerant Charge - R32 | 162.3 oz |
Additional Charge | 0.215 oz/ft |
REFRIGERANT PIPING
Line Set Size (Liquid - Gas) - Flared Connections | 3/8 - 3/4 in |
Pre-Charge Length | 31 ft |
Pipe Length (Min - Max) | 10 - 98 ft |
Max. Pipe Elevation | 49 ft |
DIMENSIONS
INDOOR UNIT (FXA48C32AH)
Unit: inch
Dimension | Value |
---|---|
W (Width) | 24-1/2 |
D (Depth) | 21-1/4 |
H (Height) | 28-1/2 |
A (Front panel width) | 22-7/8 |
B (Side panel width) | 19-3/8 |
E (Service access panel width) | 8 |
F (Bottom panel width) | 4-1/8 |
Diagram Description: A schematic of the indoor unit showing dimensions labeled W, D, H, A, B, E, and F.
OUTDOOR UNIT (FXU60HP230V1R32AO)
Unit: inch
Dimension | Value |
---|---|
A (Width) | 35-7/16 |
B (Depth) | 16-1/4 |
C (Height) | 49-5/8 |
D (Front panel width) | 22-7/16 |
E (Side panel width) | 14-7/8 |
G (Base width) | 13-3/8 |
Diagram Description: A schematic of the outdoor unit shown from front, side, and bottom views, with dimensions labeled A, B, C, D, E, and G.
CLEARANCES
INDOOR UNIT
Minimum clearance:
Diagram Description: A schematic of the indoor unit installation showing minimum clearance zones around the unit, with labels indicating '≥3"' on sides and top, and '≥25"' in front for service access.
Note: When installing the coil, minimize refrigerant tubing length. Do not install the air handler above or below the condenser in a way that violates condenser instructions. Service clearance takes precedence. Allow a minimum of 25 inches in front of the unit for service clearance. The drain pan must be at least 2 inches away from a standard gas-fired furnace heat exchanger and at least 4-6 inches away from any drum-type or oil-fired furnace heat exchanger. Closer spacing may damage the drain pan and cause a leak.
OUTDOOR UNIT
Minimum clearance:
Note: Install the Outdoor Unit 2 Inches Above the Expected Snow Line.
1. When one outdoor unit is to be installed:
Diagram Description: A schematic showing an outdoor unit with clearance dimensions labeled a, b, c, d, e, H, Hb, Hd, and H1. The diagram illustrates various installation configurations and the corresponding minimum clearance requirements based on unit placement and height relationships.
Configuration | a | b | c | d | e |
---|---|---|---|---|---|
A-E | - | ≥ 4 | - | - | - |
A, B, C | > 12 | ≥ 4 | ≥ 4 | ≥ 40 | - |
B, E | - | ≥ 4 | - | ≥ 40 | - |
A, B, C, E | > 12 | ≥ 6 | ≥ 6 | ≥ 40 | - |
D | - | - | - | ≥ 40 | - |
D, E | - | - | - | ≥ 40 | - |
B, D | - | ≥ 4 | - | ≥ 40 | - |
B, D, E | - | ≥ 4 | - | ≥ 40 | - |
H ≤ 1/2H | ≥ 10 | - | ≥ 80 | ≥ 40 | - |
1/2H < H ≤ H | ≥ 10 | - | ≥ 80 | ≥ 40 | - |
H > H | Prohibited | - | - | - | - |
H₁ | ≥ 4 | - | ≥ 80 | ≥ 40 | - |
H₁>H | Prohibited | - | - | - | - |
H ≤ 1/2H | ≥ 4 | - | ≥ 80 | ≥ 40 | - |
H₁>H, 1/2H < H₁≤H | ≥ 8 | - | ≥ 80 | ≥ 40 | - |
H > H | Prohibited | - | - | - | - |
2. When two or more outdoor units are to be installed side by side:
Diagram Description: A schematic showing multiple outdoor units installed side-by-side, illustrating clearance dimensions a, b, c, d, e, H, Hb, Hd, and H1. The diagram depicts various arrangements and height relationships between units.
Configuration | a | b | c | d | e |
---|---|---|---|---|---|
A-E | - | ≥ 12 | ≥ 40 | - | - |
A, B, C | > 12 | ≥ 12 | ≥ 40 | ≥ 40 | - |
A, B, C, E | > 12 | ≥ 12 | ≥ 40 | ≥ 40 | - |
D | - | - | ≥ 80 | - | - |
D, E | - | - | ≥ 80 | ≥ 40 | - |
B, D | - | ≥ 12 | ≥ 80 | - | - |
B, D, E | - | ≥ 10 | ≥ 80 | - | - |
H ≤ 1/2H | ≥ 12 | ≥ 100 | ≥ 12 | ≥ 80 | ≥ 40 |
1/2H < H ≤ H | ≥ 12 | ≥ 100 | ≥ 12 | ≥ 80 | ≥ 40 |
H > H | Prohibited | - | - | - | - |
H₁ | ≥ 12 | ≥ 100 | ≥ 12 | ≥ 80 | ≥ 40 |
H₁>H | Prohibited | - | - | - | - |
H ≤ 1/2H | ≥ 10 | ≥ 100 | ≥ 40 | - | - |
H > H, 1/2H < H ≤ H | ≥ 12 | ≥ 100 | ≥ 40 | - | - |
H > H | Prohibited | - | - | - | - |
3. When outdoor units are installed in rows:
Diagram Description: A schematic illustrating multiple outdoor units installed in rows, showing clearance dimensions b, d, and e. Minimum clearances are indicated for different height relationships (H, Hb, Hd) and row configurations.
Height Relationship | b | d | e |
---|---|---|---|
H ≤ 1/2H | ≤ 10 | ≥ 16 | ≥ 80 |
1/2H < H₁ ≤ H | ≤ 12 | ≥ 16 | ≥ 80 |
H > H | Prohibited | ≥ 16 | ≥ 160 |
4. When outdoor units are installed one above another:
Diagram Description: A schematic showing outdoor units installed vertically, one above another. Clearance dimensions a, b, and H are indicated, with minimum requirements for side (a, b) and vertical (H) spacing.
Configuration | a | b | H |
---|---|---|---|
Vertical Spacing | ≥ 20 | ≥ 3 | ≥ 80 |
Side Spacing | ≥ 16 | ≥ 3 | ≥ 80 |
Base Spacing | - | - | ≥ 80 |
[ETL Listed]